No video

Lap length & Development length | Lap length | Development length | As per IS-456:2000

  Рет қаралды 4,173

Civil Engineering Mastery

Civil Engineering Mastery

3 жыл бұрын

Hello Everyone!!!
This video explains about what is lap length, development length with examples and guidelines to calculate lap length and development length as per IS-456:2000.
Keep watching!!!Enjoy Learning!!!

Пікірлер: 21
@sasikumartherayil9620
@sasikumartherayil9620 3 жыл бұрын
Madam Try to explain sloping slabs and their detailing forces on wall etc
@_NigmalRajas
@_NigmalRajas 3 жыл бұрын
Mam Bottom rod is not necessity for development length, in site we are provided only top bar.... It's crt Or wrong
@Pradeep-vl5yf
@Pradeep-vl5yf 3 жыл бұрын
If slab ratio ly by lx is less than two but not supported on four sides, then it will be designed as two way or one way slab
@CivilEngineeringMastery
@CivilEngineeringMastery 3 жыл бұрын
Two way slab. please refer the below link kzfaq.info/get/bejne/eZ-Xraik25rcgmw.html kzfaq.info/get/bejne/i8-kecuU0r22kZs.html
@Pradeep-vl5yf
@Pradeep-vl5yf 3 жыл бұрын
@@CivilEngineeringMastery I've seen that mam, but the above question answer
@CivilEngineeringMastery
@CivilEngineeringMastery 3 жыл бұрын
ok .If the slab is not supported on four sides it comes under the category of four edges discontinuous. If ly/lx less than 2 then it is two way slab.
@Pradeep-vl5yf
@Pradeep-vl5yf 3 жыл бұрын
@@CivilEngineeringMastery thank you
@sasikumartherayil9620
@sasikumartherayil9620 3 жыл бұрын
For two fkur supports are compulsory
@jawaharbharani1866
@jawaharbharani1866 3 жыл бұрын
How to design for concealed beam in stadd pro.
@CivilEngineeringMastery
@CivilEngineeringMastery 3 жыл бұрын
Concealed beam concept is not advisable to use and also which is not mentioned in any of the codes.
@akashbabaria1444
@akashbabaria1444 3 жыл бұрын
Wht is anchorage length mam
@akashbabaria1444
@akashbabaria1444 3 жыл бұрын
Why lap length is considered by small dia
@CYBERxSigma
@CYBERxSigma 6 ай бұрын
sigma s is 0.87xfy please correct this
@famcivilengineer34
@famcivilengineer34 3 жыл бұрын
You are wrong about lap length Location.. Lap length should not be provided in the middle or end of the member.. Lap length should be provided at L/4 distance from end.. Ome thing more you need to elaborate this topic... Lap length for different members of rcc structure are different like for for column, beam and slab value of lap length differ.. One more question what is minimum value of dev length should be provided..
@CivilEngineeringMastery
@CivilEngineeringMastery 3 жыл бұрын
Thanks for the notification. Minimum development length should be 300mm.
@sasikumartherayil9620
@sasikumartherayil9620 3 жыл бұрын
Madam think of Ld, Ld/3 Lap for tension lap for compression. In practice lapping is done wherever they like irrespective of theory.
@kamalabd2705
@kamalabd2705 3 жыл бұрын
send the cad file plz
Reinforcement Lapping Zone in Column || Civil Designs  || IS 456:2000
16:52
CIVIL Engineering Tutorials
Рет қаралды 49 М.
What is Lap Length?
5:27
Engineering Motive
Рет қаралды 101 М.
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 12 МЛН
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 53 МЛН
Pool Bed Prank By My Grandpa 😂 #funny
00:47
SKITS
Рет қаралды 18 МЛН
How to Calculate Development Length of Bar as Per IS 456 2000 | By Learning Technology
12:42
What is GD&T in 10 Minutes
10:09
Straight To The Point Engineering
Рет қаралды 304 М.
6 Verbal Tricks To Calmly Dismantle An Aggressive Person
11:45
Charisma on Command
Рет қаралды 23 МЛН
The Greenwich Meridian is in the wrong place
25:07
Stand-up Maths
Рет қаралды 739 М.
What is Lap Length | Overlapping | Lap Splices in Beam | Column | Footing and Pile Cap
14:59
Why Buildings Need Foundations
14:51
Practical Engineering
Рет қаралды 3,5 МЛН
Difference Between Development Length and Lap Length | Learning Civil Technology
13:26