Leader Ecomatic 110 pump priming

  Рет қаралды 159,760

Jamie Wallace

Jamie Wallace

7 жыл бұрын

A simple demonstration of priming a leader ecomatic 110 pump at spring start-up when using this pump with a cistern.

Пікірлер: 26
@jessicastolte382
@jessicastolte382 3 жыл бұрын
Great video. Thank you!
@landdesigner
@landdesigner 2 жыл бұрын
You are welcome!
@tarunroy2148
@tarunroy2148 2 жыл бұрын
o
@tarunroy2148
@tarunroy2148 2 жыл бұрын
@@landdesignerl90
@farmingideasph
@farmingideasph 2 жыл бұрын
best for irrigation in the farm
@josephpesana4140
@josephpesana4140 2 жыл бұрын
How to order a good Drummond water compressor's and how much the TCPrice pls
@carlosfernandez1
@carlosfernandez1 2 жыл бұрын
Muy bueno. It works pretty good. Are you going to put e housing on it?
@landdesigner
@landdesigner 2 жыл бұрын
Yes we built a pump shelter around it. We drain and take it inside during the winter.
@kevinforse5290
@kevinforse5290 Жыл бұрын
good video
@dr.prateeklagoo6129
@dr.prateeklagoo6129 6 жыл бұрын
Please guide how to solve the problem where this pump (Ecomatic 110) repeatedly starts and stops during water flow?
@jaandesigns7013
@jaandesigns7013 6 жыл бұрын
HI Prateek. Can you expand on your question? As I'm sure you know the small pressure tank and pressure switch turn the pump on and off as needed. This system turns on the pump on once it goes below 30psi and off once it hits 45psi (I'm pretty sure on those but the pressure range maybe slightly different. Also what size is your inlet or supply line, mine is 1.5" right up to the pump inlet were I reduce it to 1".
@dr.prateeklagoo6129
@dr.prateeklagoo6129 6 жыл бұрын
Jaan Designs Thanks for the reply. The Intel supply line is the same as yours. 1.5" dropped down to 1". The problem is when we start the pump it builds up pressure till 45 psi even if no taps are open and then stops working. Soon after the pressure automatically drops to 30 psi with all the taps closed and the pump starts again to maintain 45 psi. And this cycle continues irrespective of if the taps are open or closed. Outlet supply line is 1" converts to 1.5".
@landdesigner
@landdesigner 6 жыл бұрын
Sounds like you have a leak...do you have a check valve installed on the supply line..the one on my pump is a stainless steel 1". The check valve allow water to flow through it in one direction only. This is super important otherwise the pump will try and pressurize your supply. Hope that helps. 1.Check for leaks 2.Check for a check valve. Take care.
@dr.prateeklagoo6129
@dr.prateeklagoo6129 6 жыл бұрын
Jamie Wallace thanks for the solution. The problem was because of the absence of check valve. Once it was installed the pump is working as it should be.
@jackb1803
@jackb1803 5 жыл бұрын
You also should check the pressure in the air tank before starting up. It should be set 2 psi under the cut-in setting. So if 30-50, set it to 28 psi.
@SO-kv5cc
@SO-kv5cc 3 жыл бұрын
Thanks
@landdesigner
@landdesigner 2 жыл бұрын
No problem
@videos40058
@videos40058 2 жыл бұрын
hi i read the manual one hour ago. iit says you need to pressure the cilinder with 1.5 bar or 22 psi before you load the system with water. There for i also installed one today but never primed it and never put any pressure to it. What can it go wrong?
@landdesigner
@landdesigner 2 жыл бұрын
Checking the tank's pressure is a good idea. Priming a pump is one of those best practices. The water will help cool all the moving parts and reduce stress on the pump at startup. Hope your pump serves you well.
@AJ-sb8qk
@AJ-sb8qk 3 жыл бұрын
But I have a well next to my house I bought a one horse power Drummond shallow well pump I hooked everything's up but I'm not getting air pressure do you have any idea why
@duck5336
@duck5336 3 жыл бұрын
Did you put a foot valve, and filled the prime plug completely up?
@antalpap5065
@antalpap5065 2 жыл бұрын
A gépkönyv és a józan paraszt ész a következőt diktálja A szivócső meretét egy mérettel fölfelé bővitjük a nyomó vezetéket egyel lefelé 5/4- 3/4" Ugynis ha aviz nem tud a szivatyuba bejútni ki se jön belölle Igy viszont kap egy előfeszitést a szivattyu és közel idelis lesz a munka pontja ill a teljesitménye.
@ngoipham7011
@ngoipham7011 2 жыл бұрын
L
@alistars2860
@alistars2860 2 жыл бұрын
من
@harunvirochannagar6135
@harunvirochannagar6135 2 жыл бұрын
80 fit Bor me you sistam
Replace Cottage Jet Pump - Prime Pump - Spring Cottage Opening
17:59
MUDBRATS // SNOWBRATS
Рет қаралды 38 М.
Shallow Well Pump - Losing Prime - Diagnose Suction Leak
1:01
Clear Water Pump & Well LLC.
Рет қаралды 38 М.
Мы никогда не были так напуганы!
00:15
Аришнев
Рет қаралды 6 МЛН
That's how money comes into our family
00:14
Mamasoboliha
Рет қаралды 9 МЛН
DO YOU HAVE FRIENDS LIKE THIS?
00:17
dednahype
Рет қаралды 87 МЛН
Насосная станция LEO LKJ 601IA
2:40
Отвертка.kz
Рет қаралды 4,2 МЛН
Funcionamiento bomba autoclave Einhell GC-WW 6538 Set
2:05
AgriEuro España
Рет қаралды 17 М.
How to Prime a Jet Pump
8:23
R.C. Worst & Co., Inc.
Рет қаралды 669 М.
I turned water container into a working pressure tank!
7:14
Keyto Channel
Рет қаралды 658 М.
Pumpautomat
8:47
Rörmokarläraren på Polhemsskolan
Рет қаралды 32 М.
Priming a water well pump
0:16
Clear Water Pump & Well LLC.
Рет қаралды 42 М.
Hidrofor Evotools Jet 110, 900 W, 20 l, 6 bar, debit 50 l/min
8:01
How to Prime a Well Pump
4:48
Homes for Beginners
Рет қаралды 221 М.
INSTALACION DE HIDRONEUMATICO EN TINACO
2:12
ozltorres
Рет қаралды 320 М.
Мы никогда не были так напуганы!
00:15
Аришнев
Рет қаралды 6 МЛН