No video

Lennox Supply Chain parts not available

  Рет қаралды 39,815

Anti DIY HVAC

Anti DIY HVAC

Күн бұрын

Пікірлер: 140
@jamescollins6085
@jamescollins6085 Жыл бұрын
It's crazy that supply chain issues are still affecting companies in late 2022. They need to find suppliers in multiple countries so that if one fails to meet demand, they can ramp up production elsewhere.
@acmaster244
@acmaster244 Жыл бұрын
There’s several things you can do to get them temporary heat but the first thing I would check after no blower would be to go to the thermostat and put it in the Fan On position to see if that circuit is working. You could also get a universal control board that replaced lots of OEM boards and not deal with Lenox if you can’t get the OEM from them.
@Whats12345
@Whats12345 Жыл бұрын
Ted this is a perfect example of technological crossroads.... The PCB on that Furnace is built to control a Version 2.3 ECM Blower Motor. Lennox decided to NOT implement a Version 3.0 ECM PCB on their Furnaces at that time, so the way to circumvent the issue was to use the Version 2.3 ECM PCB and install a "decoder" of sorts to literally translate the AC prior version ECM language into a DC communicating ECM Blower Motor. Basically....technology causing technological issues!!!
@sknight0391
@sknight0391 Жыл бұрын
That old motor will make a good boat anchor now. 😎👍
@bobbywanger8123
@bobbywanger8123 Жыл бұрын
😂😂😂😂😂😂
@chatrkat
@chatrkat Жыл бұрын
Your response “ah huh” was mine too when I saw that ECM. $$$$ service call. I’ll keep my good old PSC motors, thank you.
@chuckquinn8026
@chuckquinn8026 Жыл бұрын
Excellent work as always plus always a class act especially when talking about a competitor company…👍👍 Glad you are getting the replacement job and hope to see videos of the job
@Theoldchum
@Theoldchum Жыл бұрын
How about a single stack old fashioned heater style blower relay and leave the psc motor as a permanent fix. The slight loss in efficiency won't be as costly as having you come back and swap back to the OEM parts.
@craigbraswell4269
@craigbraswell4269 Жыл бұрын
That little transformer looking device is used for "circulation" speed. They use that to send a very light signal to the blower module to step the speed down to circulation only.
@barronweir123
@barronweir123 Жыл бұрын
Lennox used to be made in America from what I understand. I cone across very old Lennox furnace and ac. Built like a tank with the metal and electrical. Probably still needs replacing or really watch the CO output. But I am always impressed seeing that very old Lennox stuff and made in America. Reaching 30 to 40 yes old
@donaldpainter956
@donaldpainter956 Жыл бұрын
Years ago where I was working started using those air drive zone dampers for the most part they did ok I guess we did have a pretty hard winter one year and alot of the homes that the box was under the house or in a cellar the pump or line froze and so did alot of the 90 percent furnace drain box so they went back and rethought all of those installs I guess it was a live and learn I was only like 8 years into my career so I only knew enough to be a danger to myself but things like that is what teaches us thanks for the video
@schrodingerscat7218
@schrodingerscat7218 Жыл бұрын
First time viewer from Canada. Am an engineer but know nothing about your world. I found this a fascinating fix, landing yellow and ultimately black on ground and circ was very cool. The blower is continuous but at least they have heat right away. I am still trying to figure out the cap you mounted on the plenum. Liked and subscribed.
@TedCookHVAC
@TedCookHVAC Жыл бұрын
Thank you very much for watching !!
@atzron3912
@atzron3912 11 ай бұрын
Brother, you help me more times than you know. Thanks for the chipmunk voice, that was a much needed added bonus!
@peterhodgkins6985
@peterhodgkins6985 Жыл бұрын
Well, if Loren enjoys the mechanical stuff, she should (as I do) live for those moments when the fan motor drops out of the blower wheel with no special tools! ;)
@FindLiberty
@FindLiberty Жыл бұрын
Yea, And using that "old man trick" to break the rusted motor shaft free of the blower cage was a classic Anti DIY HVAC YT video! Do we all recall those details (cutting off the mushroomed end and "drilling" the motor shaft just to heat it up.) ?
@Eddy63
@Eddy63 Жыл бұрын
Good vid Ted and a BIG shout out to Lauren ... Thx for posting as usual ...
@OfficialNakatsuMegami
@OfficialNakatsuMegami Жыл бұрын
Love the video, I hope you take the time to get us a bit of footage of the new install. Your install videos are the best.
@davidwright1653
@davidwright1653 Жыл бұрын
I work for a global manufacturer of HVAC components and I'll bet parts from my company are in that very furnace Ted is working on. Our manufacturing plants are in Mexico with distribution warehouses in Canada, Europe and Asia. My specific function is auditing parts prices for profitability. The supply chain shortages are still very real unfortunately as we close out 2022, but that's what we get relying on China for the majority of raw materials and components. Ted was shocked at the cost to replace that board, the chip shortage is responsible for that. My company is adding surcharges to the per piece price of many components and those with chips sets are the worst. One chip we use has a $25.00 surcharge. Look at that board and count how many chips are on it and you can see how it shoots up to $900.00 cost. No we aren't gouging anyone; trying to sell our products priced competitively, deliver a quality product in a timely fashion is an everyday discussion with our customers who constantly threaten to take business elsewhere. The irony of those threats is where they going to go? Our competitors are in the same situation as us.
@bigdaddy5948
@bigdaddy5948 Жыл бұрын
Wire a sequencer in parallel with the heat circuit. Slight delay on and off enough to avoid high limit problems.
@criznitty
@criznitty Жыл бұрын
In the early 2000’s I would go on calls and come across Lennox and try to order their parts and it was a super difficult and costly process. I never enjoyed working on them and didn’t understand the appeal. All I know is that if someone has one of the mainstream brands, you can get them back up and running with inexpensive parts from Amazon.
@chrisjnoe2020
@chrisjnoe2020 Жыл бұрын
Installed many "arzel" zoning systems up here in ohio and honestly they are pretty reliable unless homeowners would get in box and monkey around and mess something up. Enjoy all you videos!
@BrickTop900
@BrickTop900 Жыл бұрын
They look like the old pneumatic Honeywell actuators we see on old chilled and heated water systems from the 70’s and 80’s here. Slowly ripping them out and replacing 40 years later
@donaldpainter956
@donaldpainter956 Жыл бұрын
@@BrickTop900 that's what they made me think of when I first seen them I did commercial install before getting into residential
@donaldpainter956
@donaldpainter956 Жыл бұрын
Did you ever see any of them freeze up I know your winters are alot harder than ours in north Carolina it was a winter here it stayed in the teens for like two weeks alot of ice
@TheGgin
@TheGgin Жыл бұрын
Glad you go them going...nice move. I wonder if that ECM was replaced not too long ago as it has one of those "universal" 16 pin motors.
@jeffhorton742
@jeffhorton742 Жыл бұрын
This was awesome seeing the heat restored. Would the rust stain above the power choke be a factor? My guess is no...most likely the static pressure took out the electronic head of the motor.
@zunar_j5_933
@zunar_j5_933 Жыл бұрын
Jack of All Sprays is legit! After I saw you use it on a motor swap once, I ordered a 6 pack! It's good stuff.
@sativa2050
@sativa2050 Жыл бұрын
One trick I like using when trouble shooting blowers is, to take a cut off male end of a power cord and wire the motor leads L1 and N directly to 120V. Its a nice little trick to double check your diagnosis. saved me a cpl times from ordering an un-needed motor.
@myHVAClife
@myHVAClife Жыл бұрын
I have done that a few times. But no need for full time fan, unless you are doing a temporary fix till parts come in or unit is replaced!! For a permanent fix, Just run common to the blower and break the speed through a one pole sequencer to give you the on and off delay! Energize the sequencer with a pair of cooling and heating 90-340 isolation relays. A call for Y will close a relay sending 24v to the sequencer in cooling and a call for W will close a relay sending 24v to the sequencer in heating. Works as a permanent repair when replacing an ECM motor with a PSC! works in an air handler as well in a 240v set up! Leaving a blower running constantly will pull cold air back in the house when it is cold and humidity back in the house in the summer.
@r3tr0nic
@r3tr0nic Жыл бұрын
VSM/ECM good for efficiency and varied application flexibility, but not a fan of the reliability. Had mine quit one day in winter, with a electrical smoke smell , the burning circuit board kind of smell. Dismantled and found the in rush current limiters bad. Seem common failure on those... I replaced them and cleaned everything up. Ran great for another 5 months then just quit. No smell or noises this time. Did not see anything wrong (that I could get to). Had ¬340V DC from the power rectifier board into the motor half... But that's where I got stopped because the motor half is potted and no easy way to get to it. Yep, $1k+ for the motor and matching ''controller''... Dad had identical system and I borrowed his motor/controller and it fired up. Nope, not paying $1k+ for a replacement that likely will fail... Installed a tried and true PSC motor, adjusted my airflow and pressures and 8 years later shes still purring along, zero issues. $75 vs $1k+, no brainer for me. Not worried about the efficiency stuff, the costs are negligible to me.
@robertcherry4971
@robertcherry4971 6 ай бұрын
That part you said was a filter for VS motor is actually called motor choke.
@CommonSenseFishing209
@CommonSenseFishing209 Жыл бұрын
York parts too. And many others. Especially on the slightly older high end stuff. Variable speed blowers etc
@theyoungrvers8021
@theyoungrvers8021 Жыл бұрын
26 year vet here I really enjoy watching your videos. Glad to see other guys out there that onow what they're doing. Lennox is the only brand I've ever seen to install a shipping support on their large motors. You take it off when installing.
@curtwuollet2912
@curtwuollet2912 Жыл бұрын
A lot of companies have found out a lot about depending on China.
@stex1985
@stex1985 Жыл бұрын
I am so glad you posted this, I was sure I had been ripped off when my Rheem blower motor with the module had to be replaced, $1200. They wanted to replace it with a Goodman. I still have the Rheem. When it gets replaced it will be with a Trane heat pump.
@JohnCap523
@JohnCap523 Жыл бұрын
A lot of condensate drippage corrosion on the shelf snd down onto the squirrel cage, and a lot of corrosion visible through the combustion peephole.
@williamserver4332
@williamserver4332 Жыл бұрын
That damp basement was causing a lot of rust in that unit. Great video
@craigbraswell4269
@craigbraswell4269 Жыл бұрын
We still have many pulse furnaces in the w ga area.
@garyangelstad5212
@garyangelstad5212 Жыл бұрын
Did lots of pulse installs. They sure saved gas over the standard efficient of the day. No dc drive or 2/ multi stage burner. Still know of a few still working well
@PracticalCat
@PracticalCat Жыл бұрын
Damn. I wish my pcb fab house had the choice of yellow silk screen. That board looks sick!
@danwittels5542
@danwittels5542 Жыл бұрын
Ted workin' down cella! The big problem you had was you're supposed to wear a gatsby and overalls when you work on Lennox equipment 😄😆😉. Good temp fix.
@craigbraswell4269
@craigbraswell4269 Жыл бұрын
The "extra leg" is lennox's "shipping bracket". I guess they think that will keep the blower from receiving damage during transit. It is meant to be removed during installation though.
@dhallen100
@dhallen100 Жыл бұрын
Haha, love the Happy Gilmore reference! “Give ‘er a little tappy, tap-tap, tap-aroo”
@nonamesplease8228
@nonamesplease8228 Жыл бұрын
That is a newer ECM motor. The high static from the zoned system probobably killed the original and replacement motor
@brnmcc01
@brnmcc01 Жыл бұрын
Tempstar is no better. Tried to find an OEM X13 motor for a 5 ton single phase package unit. Customer has 5 of these units. Tempstar said 22 weeks on national backorder. Ended up going to a Bryant supply house, and used a couple of their Totaline universal X13 replacement motors, much cheaper and worked good right out of the box.
@justinh7957
@justinh7957 Жыл бұрын
Us motors make a great x13 universal motor as well. Plug and play with a jumper for 120v or 230v
@hayderalmajadi9122
@hayderalmajadi9122 Жыл бұрын
I love seeing the yellow 110 electric wires just dangling along side the furnace. People in the Chicago area give me hard time for using couple of Greenfield by the furnace. Different codes I guess.
@mos8541
@mos8541 Жыл бұрын
then again they also mandate the use of EMT, conduit, in all homes for every circuit, among other codes from when Unions ruled the day, while the rest of the country been using Romex for 30? plus years, that and childhood stories about Mrs. Oleary's cow burning down the city
@tgriebe
@tgriebe Жыл бұрын
I'm kind of surprised that service manuals are not available on line for any make or model, perhaps for a fee. That would sure beat head scratching.
@bills6946
@bills6946 Жыл бұрын
Goodman has service manuals available on line. I must be a minority because I like Goodman and parts are available and reasonable. Most models are easy to install and service. Installed correctly and neatly, they last and perform very well with efficiencies up there with other name brands. Great warranty also.
@JFranzen3
@JFranzen3 Жыл бұрын
I remember last year Lennox coils were TBD arrival. I know they had a bad batch of furnace box coils from like 2010-2017 where they leaked prematurely. 2015 seemed to be the sweet spot. I can't remember if it was because they weren't coated, different material or just bad design.
@James_Bowie
@James_Bowie Жыл бұрын
Unlike another KZfaq HVAC guy I could name, Ted's videos are always kid friendly because he doesn't feel the need to swear and cuss for the sake of it. I guess it's all in the breeding.
@bills6946
@bills6946 Жыл бұрын
The days of “Atta boy Dave” for Lennox are over. Lennox have become a moneymaker for service companies. Hard to get parts though.
@paulhickey4485
@paulhickey4485 Жыл бұрын
Why would you not install a relay to cycle?
@ryandickerson6805
@ryandickerson6805 Жыл бұрын
If you're going to put a PSC motor in it why not use a sequencer so it cycles on and off with the heat
@chrissipple1018
@chrissipple1018 Жыл бұрын
The part you removed was a power factor choke. The used the on the older ecm motor for efficiency. You don't see them anymore.
@jimharris1590
@jimharris1590 Жыл бұрын
Thank you Ted---go Loren!!!
@LongTrout
@LongTrout Жыл бұрын
DC Drive....Bummer. That is a pretty penny
@zachosborne6577
@zachosborne6577 Жыл бұрын
Jumping Lennox ecm are exactly the same as you described
@watermanone7567
@watermanone7567 Жыл бұрын
Excellent video. If you installed a relay, how hard would it be to add a delay on break relay??Thanks for the video.
@Garth2011
@Garth2011 Жыл бұрын
If that ECM motor has been replaced once before, I'd bet this existing motor itself is still good and the module is bad. That's usually what happens to those ECM motors, the logic part fails leaving the mechanical part unable to run yet there's nothing wrong with the motor workings. Seems like such a waste to kill all of the energy savings that people are getting to price an ECM part to be $900 when any three speed PSC motor is around $250. This is why in many cases, the higher end HVAC systems DON'T really save you money (on utility bills) in the long run due to parts that are very expensive and also a long wait to get. When they work, they do function much nicer, quieter and for a little less on the utility expenses however, just one simple breakdown is so darn expensive and inconvenient trying to source the parts. As in this video, Ted got them up and running best he could under the circumstances. Truly, its very difficult to believe that a motor was that much money and that long a wait in this day and age. Maybe the HVAC industry needs some rules that vital and safety parts must be available from the manufacturers for a good 25 years and in stock to serve their customers. The idea to support them only as long as the warranty term is purely wrong.
@HVACGUY
@HVACGUY Жыл бұрын
I can’t say I’ve seen a motor with a 16 to 4 wire converter on it like that before. Like you said, that motor wasn’t likely the original setup
@johnfranco2465
@johnfranco2465 Жыл бұрын
consider using an ecm tester if its the board then you can leave tester on it till board comes tester will engage motor if its still good
@THEMFORMATION
@THEMFORMATION Жыл бұрын
Lennox Pulse was the Golden days of innovative engineering at Lennox. Just like the spine fin can style Carriers that are still running today. And then both companies fell off and started making thinned out failure prone junk.
@1kymoonrunner
@1kymoonrunner Жыл бұрын
My Smart Comfort heating unit went out over 2 weeks ago…….can’t even get Home First warranty or Clayton Homes to call me back…..luckily I have a portable Buddy propane heater and we have only had 3 cold nights in southern South Carolina……my units aren’t even two years old.
@Danielthornton61
@Danielthornton61 Жыл бұрын
*If the installers did what they were supposed to, there will be an internal proper sized deflector diverting supply air towards the 8-inch line, installed at the main trunk connection. There's no way any substantial quantity of air would take a straight tee 90° turn on its own without a deflector.*
@mrbillpro
@mrbillpro Жыл бұрын
Just add a relay, for cool and heat, run a 24 volt common to both relay's, heat terminal off the board to the heat relay and cool off the board to the cool relay and activate the relay's right from the low voltage terminals on the board, that powered the VS motor. Of course you would have run a 120v wire, and just jump 120v from relay to relay, and use the red on the heat relay, and the black on the cool relay, and you're done. 🙂I've done this before, even with the 16 pin VS motors.
@elBusDriverKC
@elBusDriverKC Жыл бұрын
Genteq makes a GO / NO GO tool that can test those. I do commercial Lennox units and actually have made up a giant kit of tools to test boards, motors, modules etc..... They are not meant to be very field friendly. Lennox parts are coming down the pipeline a little better, but between the Marshaltown Tornado and the recent pandemic, Lennox parts have been super hit and miss.
@justinh7957
@justinh7957 Жыл бұрын
Supco makes one just like it for half the price. Works everytime
@acrservicesmathewr7565
@acrservicesmathewr7565 Жыл бұрын
That’s one thing I don’t understand. Why can’t they make an option wether you have a psc motor or ecm, they can both work by just supplying 2 connections for psc or molex for ecm. It’s all about the money with these manufacturers and they don’t give a rats a** about how the customer feels. And it makes us look bad if we can’t get them going. For how common ecm is becoming, you would think the supply would be much better now but they never have them in stock and to expensive to keep on the truck.
@russellhancock9765
@russellhancock9765 Жыл бұрын
I wish My Parent's House had a Basement in it. The Ground was to wet when they built their house for a Basement.
@melodicman3032
@melodicman3032 Жыл бұрын
The reason I go into a job site with just the basic tools is it gets really old carrying a tool bag full of tools and its so much more enjoyable and my legs and back thank me later
@rackets7991
@rackets7991 Жыл бұрын
Is only the lower blower section interlocked? Seems like there wasnt on the top heater section.
@OnusBones
@OnusBones Жыл бұрын
Nice to see another video from you. Hello Lauren! Where is Lennox made? Is this possibly a good argument in favor of North American - made Goodman? I have to think that supply chain issues for anything coming from Asia have only just begun. You need two small flashlights, one a headlamp. I'd suggest the Nicron N7 as one of them. It has a magnetic tail-cap, and the head pivots, so it can be aimed. It will run on any AA-size cell, from a 3.7V 14500 Li-ion battery down to a 1.2V NiMH. The headlamp could be something like a Sofirn HS-10, which uses a small 3.7V 16340 cell; your hair probably weighs more than it does.
@pstiegman
@pstiegman Жыл бұрын
Lennox claims they are 100% made in the USA. Apparently, Mexico is a state now.
@sku32956
@sku32956 Жыл бұрын
Goodman are bagged by a fair amount of high end dealers i.e installing expensive units .I have Goodman in 5 rentals one install was hack job it was worked on because of the bad install ,other times not too bad few calls .For me I would use them again for rentals My Lennox here was installed in 2001 dual stage furnace it has had new board ,new induce draft motor ,piping that was wrong .If I was going high end for me Lennox .
@apollorobb
@apollorobb Жыл бұрын
Just so you know YES the low speed and high speed will be hot when theres power on medium and vice versa
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 Жыл бұрын
Something wrong with Lennox these days. Bought one of the last boards for a certain series of furnace in the country a couple days ago. Carrier lacking on parts also. Not good. I don't understand how nobody can get parts, whats stopping manufacturers from making parts?
@cardsfan-ym1bj
@cardsfan-ym1bj Жыл бұрын
Not a big fan of Lennox myself,had to buy an expensive flame sensor from them the other day,unit wouldnt take a universal one,not to mention it was a pain to get to
@CommonSenseFishing209
@CommonSenseFishing209 Жыл бұрын
Same as American standard/ train. Ignitors can be the same way. Some are 90v some are 110v. Big difference
@TheFatesLieutenant
@TheFatesLieutenant Жыл бұрын
Lennox, you ".... must hate your dealers...." Ha ha ha!
@RjsEpicAdventures
@RjsEpicAdventures Жыл бұрын
Hurting country wide I believe for Lennox I’m out here in az and heard same stuff
@Drvanosdrand
@Drvanosdrand Жыл бұрын
Hey Ted, Enjoyed the Video as usual but more importantly, How About those Gamecocks !!!
@Tarpon65
@Tarpon65 Жыл бұрын
As a Florida Gator fan, living in Sarasota, Fl, I've been rooting for you guys. Nice job against the Vols and Clemson!
@TedCookHVAC
@TedCookHVAC Жыл бұрын
They stink. Bad.
@michaelburton4025
@michaelburton4025 Жыл бұрын
Go gamecocks.... The streak ends it was so sweet. And brother you do great work
@sku32956
@sku32956 Жыл бұрын
So, you are waiting for the variable speed motor to come in then swap it out for the generic one? I almost bought a variable speed motor with my Lennox back in 2001 glad I backed off. As I have aged keeping it simple as in the less electric gadgets the better, I call programmable thermostat service calls for myself and rentals.
@tomconroy7289
@tomconroy7289 Жыл бұрын
The ECM probably has a blown capacitor in it. $5 plus soldering...
@zackmax7184
@zackmax7184 10 ай бұрын
It says this was 10 months ago. Why is it playing again?
@LuxAudio389
@LuxAudio389 Жыл бұрын
There's a lot of rust on tgat unit.
@CommonSenseFishing209
@CommonSenseFishing209 Жыл бұрын
Oh my God. That one look inside the burners. That unit is not that old. Corrosion is everywhere inside the burners. Gas pressure or flue might have issues. Can also see water in furnace compartment. Variable speed blower motor failed due to water. Water came from plugged drain. Fix the real problem or root cause. I saw all that in first 30bseconds.
@pstiegman
@pstiegman Жыл бұрын
The unit is from 2006 (decoded serial number). That's 16 years in a damp cellar. And yes, it's dripping condensate, has been for a while.
@macapodaca
@macapodaca Жыл бұрын
Could it be possible that the cut ground could have been an issue causing the ecm motor to not want to work properly? Just for my personal tech info
@macapodaca
@macapodaca Жыл бұрын
Also commend you for never stopping at the first set back and try wayy more then the new generation will do.. dying breed of men and women that will fully understand the HVAC trade.. soooo much knowledge and never ending learning lessons good and bad!!💯✊🏼🤙🏼 Rock on brother! I would figure you just wire the PSC motor speeds correctly straight to the board for COOL HEAT & FAN?
@scottallen5182
@scottallen5182 Жыл бұрын
Ted, what hp motor did you go back with ? Great video by the way!
@tc7922
@tc7922 Жыл бұрын
The XV 20 with zoning for the win…
@picklerix6162
@picklerix6162 Жыл бұрын
Supply chain issues - must be the reason that my Goodman ECM motor has increased in price by $200. I guess that I will convert over to a PSC motor when the ECM motor fails.
@ForgetU
@ForgetU Жыл бұрын
Made it look easy.
@winstonmartin6179
@winstonmartin6179 3 ай бұрын
Retired et love your show, wont buy a lennox
@jeffreywhitlatch1409
@jeffreywhitlatch1409 Жыл бұрын
Single pole sequencers make for nice time delay relays. Lennox putting a 16 pin module on a motor that isn't. Why use the 16 pin at all.
@ryandickerson6805
@ryandickerson6805 Жыл бұрын
Lot of guess work in your diagnosis
@waderigsbee6923
@waderigsbee6923 Жыл бұрын
you need to find a good eletric repair shop that can repair those motors.
@damnedspartan3588
@damnedspartan3588 Жыл бұрын
What do you think of the Mr Cool split units?
@rangepro
@rangepro Жыл бұрын
I have an Lenox pulse furnace in my home that is 30 years old, still working like a charm. I am curious, YOU DON"T LIKE THEM?
@natepeterson7145
@natepeterson7145 Жыл бұрын
They're a pain in the ass to fix plus a lot of them have cracks on the distributor tube in the heat exchanger.
@justinh7957
@justinh7957 Жыл бұрын
Just because it's working doesn't mean it's safe. When was the last time the heat exchanger was pressure tested?
@CommonSenseFishing209
@CommonSenseFishing209 Жыл бұрын
Put a fan sequencer in there and you don't have to hack job it with the fan constantly on. Just replaced a variable speed blower with a peanut relay for cooling and fan sequencer for heating. And yes those prices are legit even for dealers. York variable speed was 1300 for the variable speed motor. Lennox is about the same.
@justthetip96
@justthetip96 Жыл бұрын
Do you play NMS?
@drg424
@drg424 Жыл бұрын
Old chum I do this all the time, you save the consumer money and the psc will last 5times as long as a x13 piece of trash, the energy payback will not be realized until the unit needs to be replaced. X13 is just smoke and mirrors to get manufacturers more profit in my opinion.
@curtwuollet2912
@curtwuollet2912 Жыл бұрын
At $1000 for a motor, it would be time for a new Goodman.
@caru3257
@caru3257 Жыл бұрын
I got a few motors.
@111000100101001
@111000100101001 10 ай бұрын
Toenail clippers…aka wire strippers!
@AndrewFremantle
@AndrewFremantle Жыл бұрын
Lots of chipmunk HVAC guy in this video!
@kthwkr
@kthwkr Жыл бұрын
Variable speed motors = nonsense. Two speeds. Slow one for heat and fast one for cool. A two speed motor will work for 50 years. Good choice leaving them with full time fan. That keeps the heat in the house homogenized and fewer cold areas.
@tonybochiano
@tonybochiano Жыл бұрын
Supply shortage is due to incompetence in the government
@steveg5576
@steveg5576 Жыл бұрын
You da bomb !
@teeg3275
@teeg3275 Жыл бұрын
Man everyone I talk to hates Lennox but I’ve had more issues with American standard than any Lennox’s
@techfive7202
@techfive7202 Жыл бұрын
Dang them trane prices lol
Old Gas Furnace Burner Service
39:04
Anti DIY HVAC
Рет қаралды 39 М.
AC Not Working Unusual issue
26:23
Anti DIY HVAC
Рет қаралды 32 М.
Zombie Boy Saved My Life 💚
00:29
Alan Chikin Chow
Рет қаралды 24 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 16 МЛН
WHO CAN RUN FASTER?
00:23
Zhong
Рет қаралды 45 МЛН
Gas Furnace Problem... how did I miss this ???
24:57
Anti DIY HVAC
Рет қаралды 74 М.
THE OTHER COMPANY COULDN'T FIGURE THIS ONE OUT EITHER
29:23
HVACR VIDEOS
Рет қаралды 1,3 МЛН
American Standard replaced Carrier .. MUST WATCH !!
12:47
BrianDTech
Рет қаралды 2,2 М.
ICP Heil heat pump air handler making noise blower motor replaced
38:15
-6°F Out... Now They Both Don't Have Heat
25:24
HVACR Survival
Рет қаралды 62 М.
gas furnace will not heat house
35:21
steven lavimoniere
Рет қаралды 104 М.
This One CONFUSED Me…
15:25
Quality HVACR
Рет қаралды 50 М.
Heil Gas Furnace Clogged and Rusted hacked install
28:45
Anti DIY HVAC
Рет қаралды 11 М.
Goodman Gas Furnace Igniter replaced no heat service call
31:08
Anti DIY HVAC
Рет қаралды 56 М.