The main reason you would need to change the flow turbine would be a no hot water fault. As the water flows through the turbine the boiler isn't recognising it and therefore not giving you hot water but heating.
These resources will teach you how to diagnose and fix any boiler: signup.advancedboilertraining...

Пікірлер: 13
@yensabi
@yensabi 3 жыл бұрын
Nice tip for that removal tool... Cheers....👍
@advancedboilertraining
@advancedboilertraining 3 жыл бұрын
That’s all good 💪
@abualam4418
@abualam4418 2 жыл бұрын
Cool video 👍👍👍👍
@deanwallis9972
@deanwallis9972 Жыл бұрын
Great videos mate! I’ve learnt a lot. I’m having a problem with the same boiler. It’s fault was e156 under voltage. Check all voltage everything was fine. However it would not reset. So, I had a spare pcb so changed it and it all fired up fine/ 1 day later I get E168 that fault code ses needs a reset, the boiler now does reset but won’t fire up on heating. And hot water brings up the fault code again. What would be looking for next? Would the flow turbine and actuator give these fault codes? Thanks
@ForrestLtd-yv2je
@ForrestLtd-yv2je Жыл бұрын
Hi. Great video. Thanks! I have this boiler but I don’t think I have the water turbine. There is a sensor clipped on to the water flow pipe. But I have an issue that there isn’t hot water when the go is on. Only when the bath is on. And this just started. Any idea what it would be?
@JamesSmith19900
@JamesSmith19900 3 ай бұрын
Hi Did you ever make a video on taking 'the right hand block' out? (water pump?) My flow sensor is not coming out for love nor money, and as you have shown - access to it is not great. I've bought the tool but all it's doing now is slipping on the brass top of flow sensor. Thanks
@tristancraven3685
@tristancraven3685 6 ай бұрын
What is it when you turn a tap on upstairs .then turn the tap off Then the boiler still thinks the taps open yet when you turn the downsiars kitchen tap on and off the dhw light on the boiler goes off .
@MrHukd
@MrHukd 2 жыл бұрын
so what the reason for this specific tool? will a standard 18mm not work?
@KneelBeforeZod.
@KneelBeforeZod. Жыл бұрын
Or you could use an 18mm socket.
@gerrosrightboot
@gerrosrightboot 3 жыл бұрын
18mm socket does it too.
@MrHukd
@MrHukd 2 жыл бұрын
yeah thats what im thinking so is there another reason folks are buying a tool which only just seems like a standard socket?
@geomac7241
@geomac7241 Жыл бұрын
Needs to be a multi tooth 18mm so it won’t slip
@sidco123
@sidco123 2 жыл бұрын
Those things don't come out after 8 years.
Main Eco Elite | Changing The Diverter Valve & Cartridge
8:17
Advanced Boiler Training
Рет қаралды 16 М.
Gas Training - Boiler Fault Finding - No Hot Water - Roy Fugler
23:43
ЧУТЬ НЕ УТОНУЛ #shorts
00:27
Паша Осадчий
Рет қаралды 10 МЛН
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 211 МЛН
World’s Largest Jello Pool
01:00
Mark Rober
Рет қаралды 101 МЛН
Vaillant EcoTec Pro - Changing The Pump Body
17:55
Advanced Boiler Training
Рет қаралды 20 М.
Part 1 - How to remove the floatswitch / bobbin type inlet cartridge on the Baxi Duo-tec HEA boiler
6:28
Baxi - sustainable heating and hot water solutions
Рет қаралды 10 М.
The elbi diverter motor stripped down
6:53
Adam Carter
Рет қаралды 8 М.
Ideal Logic / Vogue No Hot Water - How To Test - Plumber
12:23
Allen Hart
Рет қаралды 60 М.
Main Combi 30 eco Elite No Hot Water Boiler Repair Accelerated Training
14:56
A+R Central Heating and Boiler Repair Experts Ltd
Рет қаралды 4,3 М.
A Review Main Eco Elite 25/30 Condensating Combi boiler ERP review 
5:40
ЧУТЬ НЕ УТОНУЛ #shorts
00:27
Паша Осадчий
Рет қаралды 10 МЛН