MEP 802A - Using auxiliary fuel connection

  Рет қаралды 5,043

CallMeColt

CallMeColt

5 жыл бұрын

This is a simple process but when I was first looking into surplus generators, I couldn't find much on exactly how it worked. Figured I would make a video showing it. This process is very similar on almost all military generators.
Since making this video, I started selling a kit to adapt & make your own line for doing this! Check it out here;
ebay.us/80YyKz

Пікірлер: 19
@emailuser3869
@emailuser3869 2 жыл бұрын
Thanks brother. Proud new owner of a MEP-1040 and needed this support.
@CallMeColtLLC
@CallMeColtLLC 2 жыл бұрын
Those look like interesting units.
@brianmorrison9066
@brianmorrison9066 4 жыл бұрын
Fyi it actually runs cooler with all hatches closed. Thanks for the video. I didnt know how the fueling worked.
@philstreeter9703
@philstreeter9703 3 ай бұрын
Great video. Thanks
@CallMeColtLLC
@CallMeColtLLC 2 ай бұрын
Glad it was helpful
@billjenkins687
@billjenkins687 2 жыл бұрын
Thanks. I learned how to import remote fuel. Good job.
@CallMeColtLLC
@CallMeColtLLC Жыл бұрын
Thank you, glad you found it helpful.
@chrisgentry7195
@chrisgentry7195 4 жыл бұрын
I see these on Ebay all the time for some really good prices. Damn tough generator and great for backup power.
@CallMeColtLLC
@CallMeColtLLC 4 жыл бұрын
As long as you get everything going 100% they are!
@minionman6177
@minionman6177 4 жыл бұрын
they sell on govplanet.com. 803A(10KW) Brand new about $5-6k (less than 50 hrs). I picked up one with about 100 hrs for $3k with the trailer. Still had sticker on it indicating prices was over $25K. Outstanding value for a tough machine. I have no idea why the gov't is selling so many of these.
@ucfsub
@ucfsub 2 жыл бұрын
@@minionman6177 They've moved away from the MEP platform and onto the AMMPS platform for generators.
@rongray4118
@rongray4118 6 ай бұрын
@@minionman6177 would love to pick up a unit like the one you got.
@rongray4118
@rongray4118 6 ай бұрын
Looking for a unit like this for off grid power to add to a 48 volt Schneider 6848 inverter system
@CallMeColtLLC
@CallMeColtLLC 6 ай бұрын
I have one for sale, not sure of your location. These are a great option for an off grid application that has a battery bank. With a simple add-on, they can be remotely controlled & set to be turned on automatically if called for by a charger. ebay.us/jFvvLc
@maciejciesielski3370
@maciejciesielski3370 28 күн бұрын
Is the auxiliary fuel system (external tank) connected to the main tank? Does it only refill the main tank or is it a completely separate system with a separate (auxiliary) pump?
@CallMeColtLLC
@CallMeColtLLC 25 күн бұрын
At 4:54 , that is what I was talking about, it refilling the tank. Also at 3:55 I talk about the two different pumps.
@maciejciesielski3370
@maciejciesielski3370 25 күн бұрын
@@CallMeColtLLC I see. Thank you. Looking at the diagram (FUEL SYSTEM DIAGRAM), it turns out that MEP cannot operate only on an external tank. I can only refill the main tank from the external one, manually turning on the additional pump every 7-10 hours. Do I understand correctly?
@kamrankhan-dn8sl
@kamrankhan-dn8sl Жыл бұрын
Sir how clear coolant hi temperature cod
@CallMeColtLLC
@CallMeColtLLC Жыл бұрын
Not sure what you are asking? If it has a high temperature, that means it is overheating.
MEP 803A Rebuild - Part 2
17:50
CallMeColt
Рет қаралды 6 М.
Getting my Auction MEP-802A Generator Started - First Start
27:42
Diesel Pack Garage
Рет қаралды 10 М.
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 195 МЛН
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
Задержи дыхание дольше всех!
00:42
Аришнев
Рет қаралды 3,8 МЛН
لقد سرقت حلوى القطن بشكل خفي لأصنع مصاصة🤫😎
00:33
Cool Tool SHORTS Arabic
Рет қаралды 28 МЛН
MEP-805A military diesel generator. Will it run after sitting for years?
6:16
Cross Creek Classics
Рет қаралды 2,5 М.
MEP 802A MEP 803A Remote Start Kit
28:59
Kurt Klopp
Рет қаралды 9 М.
MEP 802A & 803A Well Nut Upgrade
13:15
CallMeColt
Рет қаралды 1,5 М.
MEP 802A - Fuel level sender replacement w/improved parts
13:59
CallMeColt
Рет қаралды 2,8 М.
5 KW MEP 802A full and part load test Oct 1 2016
7:58
Mil Gen
Рет қаралды 16 М.
Mil-Spec, the best you can do?
17:56
DavidPoz
Рет қаралды 409 М.
DEMO MEP802a 5kw Military generator walk around features
4:53
NoNonsenseKnowHow
Рет қаралды 43 М.
MEP 803A Rebuild - Part 1
16:24
CallMeColt
Рет қаралды 3,9 М.
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 195 МЛН