This video is about Step 3 Rough alignment and soft foot
Пікірлер: 16
@ValeriiAS5 ай бұрын
Man, thanks for this useful lesson, I appreciate it!
@Mikesfilmss4 ай бұрын
My pleasure!
@hamzadriss13585 жыл бұрын
thanks for sharing, really it helps
@michaelpowers77445 жыл бұрын
Doing shut downs and running around on different jobs we run across bolt bound motors all the time. Typically you can get it close enough that the mill finds acceptable and nothing big has to be done. Typically this happens when replacing the old motor with a new one and something has changed between the feet design.
@CedaxV5 жыл бұрын
I agree. In the field we run into bolt bound often, usually we ream the holes and move on.
@adamn1371 Жыл бұрын
@@CedaxV yep
@brandonjones557 Жыл бұрын
Improper commissioning has happened for me.
@jintochacko64083 жыл бұрын
Thanks brother for help
@Srk70285 жыл бұрын
Which alignment to do first.angular or parallel ?
@mouddebfarouk24212 жыл бұрын
شكرا لك
@pauldavalos7734 жыл бұрын
How do I adjust pipe stress if the pump is fixed but the pipe doesn’t line up to the pump?
@jacobanderson25364 жыл бұрын
Fix pipe stress first. AFTER the plumbing is correct, the pump officially becomes unmoveable.
@mohamedabdelmaksod6603 жыл бұрын
adjust the piping supports to remove pipe stress from the pump
@domicorb300013 жыл бұрын
What if the motor is higher than the pump?
@dulalkhan5111 Жыл бұрын
Wher your from boss
@loidsregner39972 жыл бұрын
did not show how to correct the difficult angular sofoot. parallel is easy to correct