In this episode, we’re going to talk about the how to calibrate calipers.
In past Mitutoyo Metrology Training Lab episodes, we have defined the concept of calibration, discussed the purpose of calibration, and introduced important aspects of what makes a good calibration method. In this episode, we will apply all those ideas to the calibration method for a caliper.
Calibration is a search for errors and we want to develop a calibration method that efficiently hunts down and finds any potential errors in the measuring instrument. So how do we best do that for a caliper? Well, there is a nice American National Standard for digital, dial, and vernier calipers, called ASME B89.1.14, and the calibration method we’ll be discussing is based on that standard.
#Mitutoyo #CaliperCalibration #Metrology

Пікірлер: 136
@amardipsinhrahevar707
@amardipsinhrahevar707 6 жыл бұрын
I working in automotive industry in standard room. We need calibration training. So what to do?
@inderpalchawla
@inderpalchawla 4 жыл бұрын
I do not work for or receive any compensation for my endorsement of this company. I have dealt with them for 30+ years and find them reputable and fair. MILHARD SALES PVT. LTD.
@OninDynamics
@OninDynamics 2 жыл бұрын
i like how they just pinned this without replying xD
@ET-cj8jo
@ET-cj8jo Жыл бұрын
In Japan, Mitutoyo is pronounced Mitsutoyo, and is written that way in katakana on the Mitsutoyo website (ie ミツトヨ). The tu instead of tsu is a hang up from the romanization of Japanese in pre-war days. There is no such sound as tu in Japanese and never has been. The company was originally established as 三豊製作所 (Mitsutoyo seisakujo). Seisakujo (or seiksakusho) means something like factory, literally "things-make-place", so basically manufacturing. The characters 三豊 are also pronounced Mitoyo, and used as a place name. The Japanese website of Mitsutoyo has a history section, and states that the company started as a research institute in Kamata, Tokyo. There is no clue as to why the company was named Mitsutoyo. However, when the second character (toyo) is attached to a number, then it means something like "exceeding standard". So as 三 means three, then it is possible that the founder of the company in the 1930s wanted to express a high standard of quality for the products, and named the company thus. Toyo can also be interpreted as meaning abundant, rich. Best wishes from Japan.
@K0zil1a
@K0zil1a 2 жыл бұрын
Jim was my instructor for the Mitutoyo Metrology Course that I attended at Mitutoyo's NA Headquarters. Having worked as a QA manager in Automotive/Aerospace for close to a decade now, I will say that Jim was one of the most informed people I have ever come across in this field. He not only has the technical knowledge but also understands the field from the practical perspective of those working on the floor of these shops. If you ever get the opportunity to attend any of Mitutoyo's courses I highly recommend it.
@MitutoyoAmerica
@MitutoyoAmerica 2 жыл бұрын
Thank you for the kind remarks Robert.
@johndonlan5956
@johndonlan5956 2 жыл бұрын
Really excellent video Jim!
@MitutoyoAmerica
@MitutoyoAmerica 2 жыл бұрын
Glad you enjoyed it!
@delightfulThoughs
@delightfulThoughs Жыл бұрын
The explanations given are for "verification of measurements between tolerance" and a "calibration" method in case the device is not between "tolerance " is missing or not possible to perform. What if the device doest not pass? What to do to bring it back to specification?
@praticalmechanical1986
@praticalmechanical1986 Жыл бұрын
so by doing so much work to "calibrate", then tell me how exactly will be apply corrective action?
@md.aa730
@md.aa730 2 ай бұрын
As you said about ASME b89.1.14, there is a table there containing the MPE values for checking and comparing our measurement errors like 'E'. So if E is less than the MPE value, but not zero, must we add the value of the measured E to the next measurements we take when measuring???
@unimarklabs2511
@unimarklabs2511 4 жыл бұрын
How to check parallelism of measuring faces and how to reported value??
@gilwoode
@gilwoode 5 жыл бұрын
Jim, I also have searched the Mitutoyo website for a 0.2000" setting ring gage for the Inside knife check. I cannot find it on your website. Can you tell me where I can find this ring gage?
@MitutoyoAmerica
@MitutoyoAmerica 5 жыл бұрын
I had to special order a ceramic one, but the steel one is standard product, p/n 177-366. For some reason, it is not in our catalog, but it is currently available product. Thanks, Jim
@FRJ1982
@FRJ1982 3 ай бұрын
So this may sound like a dumb question, but so if the calipers do not come within specification would they just be considered trash? Or is there a possible way to correct them
@KISSMYACE3203
@KISSMYACE3203 3 жыл бұрын
Light is one of the most accurate forms of measurement from what I've seen...
@zaciejo
@zaciejo 3 ай бұрын
Where can you see how to use the adjusting screws to align the jaws parallelism ?
@tonyksnow3222
@tonyksnow3222 Жыл бұрын
Thanks Jim.
@bartharkemametalworks2299
@bartharkemametalworks2299 4 жыл бұрын
The caliper readout is 0.005. The tolerance is 0.001. A measurement of 0.0012 will give a readout of 0.001. Is this still within tolerance? My documentation from mitutoyo says 0.02 mm 'round-off error not included'. And I don't understand why there is a difference between the metric and the imperial system. Accuracy of 0.0015 (or even 0.001 inch) and 0.02 mm is not the same. Is there a different ISO tolerance between them?
@droneforfun5384
@droneforfun5384 11 ай бұрын
Im wondering this too.
@alainparenteau423
@alainparenteau423 5 жыл бұрын
I have searched the Mitutoyo website for a 0.2000" setting ring gage for the Inside knife check. I cannot find it on your website. Can you tell me where I can find this ring gage?
@gilwoode
@gilwoode 5 жыл бұрын
I ordered a 0.2000 inch ring gage from a company in NY called Thread Check Ink.
@user-ys4ik8px1w
@user-ys4ik8px1w 2 жыл бұрын
thanks Jim. Do we need to consider the uncertainty of the gauge blocks in the calibration?
@andreicharpentierquesada4530
@andreicharpentierquesada4530 9 ай бұрын
It depends. Gauge blocks class x has an error so low that probably you wouldn't be able to read without the proper equipment. So the answer is: if you are using the proper equipment and your equipment it's calibrated. You shouldn't. If your equipment isn't calibrated you shouldn't use it to calibrate your calipers
@EvelOttos
@EvelOttos 2 ай бұрын
Given your outside calibration data test points, what minimum measurement would you be comfortable declaring this caliper be used for and how would you back up that declaration? I will tell you from experience that when presented to modern medical device auditors, they will have issues with this caliper being used for measurements smaller than the lowest calibration point (1.0").
@michaelshelnutt3534
@michaelshelnutt3534 Жыл бұрын
How can I purchase the gages and data sheet shown?
@jwbonnett
@jwbonnett 3 жыл бұрын
I have a weird issue, I open the calliper fairly wide and then close it again, sometimes it goes back to zero and sometimes it isn't. Though I have noticed that if I take the number that it is off by on the zero point it is the correct mesurement. Any ideas what could be causing this?
@dplugCAPZ
@dplugCAPZ Жыл бұрын
faulty electronic components, seek replacement
@SuperRozack
@SuperRozack 2 жыл бұрын
How many correction Tolerance recomendation from Mitutoyo,?
@julianweiser9985
@julianweiser9985 Жыл бұрын
You can always press harder to get different readings. Press the outside of the jaws themselves together, not the body with the electronics.
@pauldiaz4273
@pauldiaz4273 3 жыл бұрын
Hi Jim where can i find a list of tolerances for calibrating different instruments?
@Carleigh1491
@Carleigh1491 Жыл бұрын
did you ever figure this out? I'm looking for the same thing as well.
@Yog883
@Yog883 Жыл бұрын
I'm also looking for the same... where can get exact list of Tolerance.??
@RussGD
@RussGD 6 ай бұрын
Also looking for this, would be very grateful if someone could point me in the right direction 👍🏻
@mikeracine3132
@mikeracine3132 5 жыл бұрын
Have a question about the tolerance you have on the result card. According to the B89 standered for "other measuring face" you are asked to use the Smpe or the scale shift. This is turn would make the tolerance +/-0.0020 for anything between 2 and 8 inches. You have the tolerance in the video at +/- 0.001. Am I missing something? Thanks Great vids and I plan on coming to Aurora for seminars soon...
@dr.jimsalsbury695
@dr.jimsalsbury695 5 жыл бұрын
You are correct on the tolerances. However, I'm measuring lengths less than 2 inches, so the +/- 0.001 inch tolerance applies.
@mikeracine3132
@mikeracine3132 5 жыл бұрын
Yes I see that now. I had a brain cramp. Thanks for a great series of vids!
@valliktad8917
@valliktad8917 6 жыл бұрын
how can you compute for the uncertainty if you are not going to take average of a number of readings?
@dr.jimsalsbury695
@dr.jimsalsbury695 6 жыл бұрын
I recommend you check out the ASME B89.1.14-2018 standard, as it includes an appendix on measurement uncertainty (for calibrating calipers).
@vignesh007svc6
@vignesh007svc6 2 жыл бұрын
How to reset the vernier
@NicksStuff
@NicksStuff Жыл бұрын
11:34 Yep, keep pressing until the calipers show the value you expect
@snakes4461
@snakes4461 2 жыл бұрын
"It's not correct to rock it around to get the value you like..." -Proceeds to rock and squeeze calipers until they read minus 5/10ths for every measurement-
@MitutoyoAmerica
@MitutoyoAmerica 2 жыл бұрын
A technician will almost always rock a caliper back and forth to allow the measuring faces to properly settle. I believe the video was trying to emphasize that a technician should not seek out a measurement result they prefer or like, but rather the correct measurement result.
@creativ01
@creativ01 Жыл бұрын
Hello i would like to ask, its worth to do a calibration for a newly purchased Mitutoyo device/caliper? I mean for personal use, not in company/commercial use. Its worth to pay extra for calibration? Thanks
@MitutoyoAmerica
@MitutoyoAmerica Жыл бұрын
Thank you for your question. Whether your tools are calibrated and how often are decisions you must make based on the history of the tool and the risk involved. Are your tools used in harsh environments? Are they used throughout the day or only sparingly? What risk do you assume if the tool is out of tolerance? For those utilizing precision tools in commercial uses, calibration is a must because the product ‘has’ to be correct. The company reputation, and possibly lives of the customers, can be at stake. Regular calibration is a must.
@christianchristian7690
@christianchristian7690 4 жыл бұрын
Can you answer to me please. What calibration procedure did you use? Why not flatness? Thanks.
@nirv
@nirv 4 жыл бұрын
No! I don't wanna!
@soniaemsise7175
@soniaemsise7175 3 жыл бұрын
for doing this calibration, do we have to have a lab granite table?
@Tonyplat98
@Tonyplat98 3 жыл бұрын
yes and a space station.
@MitutoyoAmerica
@MitutoyoAmerica 3 жыл бұрын
You do not have to use a granite surface but you do need to use a calibrated surface of some kind in order to assess the step and depth of the caliper. You should not use a general purpose countertop as it has not been calibrated and is introducing uncertainty into the equation. You might consider something like an optical flat.
@robertbach9376
@robertbach9376 Жыл бұрын
You can find a small calibrated granite surface for about 100 bucks or so.
@motleypixel
@motleypixel 4 жыл бұрын
what if it's not in tolerance, show how to make it back into tolerance, thank you
@benjaminmcintosh857
@benjaminmcintosh857 3 жыл бұрын
You'd need to either resurface or replace the measuring surfaces
@jordantyo7839
@jordantyo7839 3 жыл бұрын
There's no way to "repair" it by yourself. You'd have to get it sent to a machine shop where they can work on the surface.
@happyjack8952
@happyjack8952 3 жыл бұрын
@@jordantyo7839 nope. Actually there is. Done it myself on many calipers. Pretty easy actually.
@enhanceto4311
@enhanceto4311 2 жыл бұрын
@happy jack please explain how to do
@ArmySigs
@ArmySigs 4 жыл бұрын
My Mitutoyo calipers are way out of spec, how do I get them fixed?
@stevecolley6750
@stevecolley6750 4 жыл бұрын
+ArmySigs I do not work for or receive any compensation for my endorsement of this company. I have dealt with them for 20+ years and find them reputable and fair. North Texas Precision Instruments 7464 Dogwood Park Dr. Fort Worth TX 76118 Phone (817) 589-0011 Toll Free (866) 589-0011 Fax (817) 590-0062 Email support@ntpi.biz
@MitutoyoAmerica
@MitutoyoAmerica 4 жыл бұрын
ArmySigs, you can contact Mitutoyo Repairs at 888-MITUTOYO or you can get additional by visiting our website at www.mitutoyo.com/support/repair-service/
@markjones2349
@markjones2349 4 жыл бұрын
What do you consider "way out of spec to be"? What be kind of work do you do with them, just curious.
@jasonruch3529
@jasonruch3529 3 жыл бұрын
First off check you gibb play,,your set screws probably backed out, set so it slids smooth but no up and down between the slides, reset your origin and check with a known round or block and compare, you als need to learn your calipers (feel). I found mine are spot on with a light touch.
@epgui
@epgui 10 ай бұрын
I don't understand why it is wrong to take the average of a bunch of measurements. I understand that an instrument that doesn't repeat within a certain tolerance shouldn't be used... But presumably a tolerance is always greater than zero, right? So we might still expect our measurements to have some variance, however small? And depending on the error distribution, the average of repeated measurements would contain some information about the measurement that could not be obtained as reliably from a single measurement, no? Doesn't the central limit theorem apply here?
@m.cigledy6769
@m.cigledy6769 2 жыл бұрын
A bit late to the game, but you clearly state that the inside should be checked at a size of 3/4" minimum, and then check them at 0.5000"
@jingizu24
@jingizu24 5 жыл бұрын
I'm sorry, but this video does not show you how to calibrate the calipers. This just shows how to check the calibration. Now my calipers fail this check, so how do I adjust it to get it within specs?
@MitutoyoAmerica
@MitutoyoAmerica 5 жыл бұрын
I recognize there is some confusion with the definition of "calibration". Service or repair or adjustments (sometimes to improve accuracy) are typically part of the overall calibration process, but the essential calibration of most measuring equipment is to simply check the accuracy using reference standards. If the as-found calibration readings of a caliper show it to be out of tolerance, then addition service is needed. We plan to discuss service and repair in future episodes. For more information on the confusion surrounding the term calibration, check out kzfaq.info/get/bejne/hLxhibegptfKiH0.html Thanks, Jim
@johnmal801
@johnmal801 3 жыл бұрын
I have the same calipers. When I turn them on it shows 167.56mm instead of 000.00. How can I set them to show zero's instead of 167.56mm? Thanks
@bobjohnson7993
@bobjohnson7993 3 жыл бұрын
Press and hold the origin button with the jaws closed.
@MitutoyoAmerica
@MitutoyoAmerica 3 жыл бұрын
What's the code number on your caliper? Please email Tech.Support@Mitutoyo.com
@michaelprice7005
@michaelprice7005 5 жыл бұрын
3:00 I've never seen a metrologist (or anyone) slam calipers together like this.
@markjones2349
@markjones2349 4 жыл бұрын
I use digital callipers everyday at my job making ceramic tile. Slamming them shut will very likely throw off the zeroing of the caliper. I agree with you.
@nirv
@nirv 4 жыл бұрын
There is no slamming at 3:00. Are you watching the same video I am?
@markjones2349
@markjones2349 4 жыл бұрын
@@nirv Regardless of the time in the video, the dude CLEARLY slams them in the video. If I did that at my job where I use them roughly 8 times a day mimimum, everyday, the measurements will be off easily by at least .005" if not more. Yes it matters in manufacturing.
@nirv
@nirv 4 жыл бұрын
@@markjones2349 Give a time stamp. I didn't watch the whole thing.
@markjones2349
@markjones2349 4 жыл бұрын
@@nirv No I'm sorry but I'm not gonna go watch the video for you because your lazy.
@alihms
@alihms 2 жыл бұрын
Does anyone here know if the person doing the calibration needs to be certified? And if the certification is required, does he need to renew his certification after a certain period of time? Edit: As an auditor (still learning), I am auditing my company's supplier. The supplier calibrates their calipers, micrometers and height gages internally instead of sending them to a certified calibration agency. The guy doing the calibration has the appropriate training and certification but dated way back in 2014. I've checked ASME B89-1-14-2018. No mention of this at all.
@jacencko011
@jacencko011 2 жыл бұрын
Heya! From my 15 years inspection experience from job shops to medical manufacturing you do not need to be certified to perform in-house calibrations; you just need to know what you’re doing lol Performing monthly calibrations is usually part of the inspectors job and is totally normal. You just wanna make sure they’re using the proper masters/standards to do the calibrations. Unless the company is ISO certified, there really are no “rules” they need to adhere to (a majority of ISO is about the records you keep); most of the specs out there are kinda “suggestions” nowadays which can be unfortunate if left in the wrong hands. I am curious as to what certification was provided to you for the guy you mentioned if you don’t mind sharing it? I like to refer to Inspection as an “old man job” since you basically learn everything from some old guy who’s been doing it for 40 years lol. You shouldn’t be alarmed or concerned if they’re doing in-house calibrations; it’s just probably confusing and foreign to you if you’re not familiar with the process. If you have any specific questions please feel free to ask 👍
@Saki630
@Saki630 Жыл бұрын
yeah screw going to sleep, I had to learn about caliper calibration.
@17crescent
@17crescent 2 жыл бұрын
Am I the only one who has noticed this? For the inside measurement the calibration sheet said 1" and yet you measured 1/2" to get 0.4995"
@billshiff2060
@billshiff2060 Жыл бұрын
Yeah.
@behemothinferno
@behemothinferno 6 жыл бұрын
I'm fascinated this process is not automated
@gunchief0811
@gunchief0811 4 жыл бұрын
People are always more important than robots .. a machinist needs to know what he's doing.. if your a U.S. Marine u always need to understand how a rifle works. U cannot rely upon smart bombs all the time. Same thing here. Skilled labor is a learned apprenticeship type science. It's invaluable. It's always a Craftsman who makes precision things. Much more so than just an automated system... using calipers to measure your work is a good skill... And Mitutoyo is among the best.
@benjaminmcintosh857
@benjaminmcintosh857 3 жыл бұрын
I suppose in the vast majority of cases it's just less economical to design and build an automated process for it given how infrequently calipers need to be calibrated
@DPC037
@DPC037 3 жыл бұрын
For now 😂 lol.
@therealme613
@therealme613 Жыл бұрын
Did you invent the steak?
@MarshallSmith27
@MarshallSmith27 11 ай бұрын
I dropped my calipers on the hardwood floors and now I'm afraid they might be off
@darkguardian1314
@darkguardian1314 2 жыл бұрын
I lost an inspection job opportunity because of this. I have 35 yrs of quality and inspection on many jobs. But, we outsource all our tools for calibration. Large equipment used calibrated standards that are transferred to the big equipment. This looks like basic stuff to me and anyone can be trained to do it.
@jacencko011
@jacencko011 2 жыл бұрын
I’m very confused by your comment, what exactly caused you to loose a job opportunity?
@scottp.548
@scottp.548 2 жыл бұрын
Most companies outsource speciality tool calibration, not because they cannot do it themselves, but because it looks & is more reputable to have a neutral party inspection.
@jacencko011
@jacencko011 2 жыл бұрын
@@scottp.548 that sounds like a bunch of fluff 🙄 There is nothing shady about a company performing in house calibration. Why on earth would you think less of a place that doesn’t send out for calibration? Why would they be considered less reputable?
@charlesmaunder
@charlesmaunder 3 жыл бұрын
Am I missing something? Did he just say that -0.0005 is minus five tenths?
@airliners321
@airliners321 3 жыл бұрын
Five tenths of a thousandth. Thousandths (Thou) is a common unit of measure for this level of precision. He goes over this at 9:26
@K0zil1a
@K0zil1a 2 жыл бұрын
This is machinist terminology: .001 is a “thou” .0001 is a “ten thousandth or simply tenth”.
@ronaldsanchez1341
@ronaldsanchez1341 3 жыл бұрын
...i believe you meant 5 ten thousandths = .ooo5???????????
@MitutoyoAmerica
@MitutoyoAmerica 3 жыл бұрын
Resolution on caliper is .0005". Please veiw our online classes www.mitutoyo.com/on-demand/
@andreamitchell4758
@andreamitchell4758 Жыл бұрын
In what universe does 0.0005 = five tenths? isn't the first decimal place tenths? , doesn't it go 0.x = tenths , 0.0x = hundredths , 0.00x thousandths ? looks like what you wrote, 0.000x is five millionths not five tenths or is this some new fangled common core maths?
@MitutoyoAmerica
@MitutoyoAmerica Жыл бұрын
Hi Andrea, thank you for the question. Thou, which is short for Thousandths and ten thousandths would be shortened to tenth which are common units of measurement for this level of precision. So here, it is Five tenths (of a thousandth).
@DarkGT
@DarkGT 22 күн бұрын
In other words learn how much force to use until you get a result you like, rather than the result that is in reality. It should be a blind test, use mechanical spring type of force to ensure equal force each time.
@snusmumriken232
@snusmumriken232 Жыл бұрын
I’m so high
@SA-lr1sf
@SA-lr1sf 2 жыл бұрын
It's sad that after all these years this tool has all thee problems all related to human error and the way it is used. May be it should have a built in level or some capabilities for placement of the object being measured. If you were to measure some objects that you did not measure before and you had know prior knowledge of their size, your error would be larger. Now I know why My Hornady Caliper never gives me the same value no matter how many times I measure something. Therefore I give up hope for an exact measurement.
@epgui
@epgui 10 ай бұрын
I think you might have unrealistic expectations about how small you would like your uncertainty to be. Everything in the world is uncertain, the only question is how uncertain.
@GuardianLords
@GuardianLords 4 күн бұрын
This is inspection and validation not calibration. Calibration is correcting and setting the range.
@broderp
@broderp 6 ай бұрын
Looks like you wiggled your way to a perfectly biased calibration. I will have to question any tool that relies on a human for calibration. There should be a mechanical test that can hold the caliper at the exa t angle and pressure every time. The way it's done here looks like you wiggle until you get what you feel should be right.
@danariusrobinson5215
@danariusrobinson5215 5 ай бұрын
Sniper tools
@billshiff2060
@billshiff2060 Жыл бұрын
1:57 "Look silly" ?? Who are you talking to? Some hands in his pockets duffus? On what planet does holding something up to the light to see something "look silly"? I can't imagine what kind of do nothing, know nothing crowd you hang with to even think that.
@happyjack8952
@happyjack8952 3 жыл бұрын
Yeah but how about showing how you actually CALIBRATE the calipers.
@MitutoyoAmerica
@MitutoyoAmerica 3 жыл бұрын
You bring up a great point. There is often confusion associated with the term "calibration". It can be used differently in across metrology. The video kzfaq.info/get/bejne/hLxhibegptfKiH0.html discusses this very topic.
@JohnBlaze505
@JohnBlaze505 2 жыл бұрын
CALIPRATION
@billshiff2060
@billshiff2060 Жыл бұрын
This is NOT calibration. This is inspection. You are making NO adjustments.
@neiljolliff8170
@neiljolliff8170 3 жыл бұрын
This isn't calibration. It's just checking that the existing calibration is within tolerance. There's no method for correcting any deviation except the obvious 'Buy a new caliper'.
@MitutoyoAmerica
@MitutoyoAmerica 3 жыл бұрын
You bring up a great point. There is often confusion associated with the term "calibration". It can be used differently across metrology. The video kzfaq.info/get/bejne/hLxhibegptfKiH0.html discusses this very topic.
@15DurangoRT
@15DurangoRT 6 ай бұрын
You're NOT showing "how to" calibrate a caliper. You're just showing us a caliper that is within the tolerances of a standard.
@SonN-PAml
@SonN-PAml 3 жыл бұрын
Over all results is not a proper calibration. I think the hand tools do not work on this hand.
Gage Block Introduction - How To Use and Calibrate Gage Blocks
17:00
Mitutoyo America Corporation
Рет қаралды 88 М.
Understanding Metrology Measurement Units - Inch & Metric
11:54
Mitutoyo America Corporation
Рет қаралды 84 М.
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 4,6 МЛН
Самый Молодой Актёр Без Оскара 😂
00:13
Глеб Рандалайнен
Рет қаралды 8 МЛН
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 187 МЛН
17 Warning Signs Your Mitutoyo Calipers Are Fake
35:20
Clough42
Рет қаралды 667 М.
Calibrate - Metrology Training Lab  (What is Calibration?)
12:49
Mitutoyo America Corporation
Рет қаралды 86 М.
Inside a cheap set of eBay digital calipers
23:32
bigclivedotcom
Рет қаралды 677 М.
Outside Micrometer Calibration - How to Calibrate - Mitutoyo
16:12
Mitutoyo America Corporation
Рет қаралды 116 М.
Calibration Training - The Search for Errors Using Calibration Methods
6:45
Mitutoyo America Corporation
Рет қаралды 22 М.
What is Metrological Traceability -  Requirements Traceability and Calibration
8:22
Mitutoyo America Corporation
Рет қаралды 35 М.
The Micrometer
15:27
Museum of Our Industrial Heritage
Рет қаралды 105 М.
Digital Caliper Shootout!
21:51
Robert Cowan
Рет қаралды 37 М.
How to Read Micrometers
16:20
Stuart de Haro
Рет қаралды 1,4 МЛН
Как бесплатно замутить iphone 15 pro max
0:59
ЖЕЛЕЗНЫЙ КОРОЛЬ
Рет қаралды 2,3 МЛН
Battery  low 🔋 🪫
0:10
dednahype
Рет қаралды 12 МЛН
Как распознать поддельный iPhone
0:44
PEREKUPILO
Рет қаралды 2,1 МЛН