Multiple NO A/C Service Calls!!!

  Рет қаралды 5,336

AB HVAC

AB HVAC

2 ай бұрын

A few service calls and ended the day with a very odd compressor replacement. I couldn't for the life of me understand why I was getting what I was getting....unit seemed to be operating well but my pressures would tell me something else. Let me know if you think I made the wrong call on adding more refrigerant of if I should've added more than I did!!
#hvac #servicetechnician #techlife #heatpumps #goodman #rheem #apprentice #bluecollar

Пікірлер: 48
@sofalvr
@sofalvr 21 күн бұрын
I love the approach to troubleshooting and getting the apprentice to develop good work habits. NO BAGS ON THE CONDENSER!!!
@diyhvacguy
@diyhvacguy 2 ай бұрын
Love the comedic touch. You guys make a great team. Cheers bro
@AB_HVAC
@AB_HVAC 2 ай бұрын
Much appreciated
@Crazywill210
@Crazywill210 2 ай бұрын
Love your videos, guys. The one thing I noticed is that don't forget to change filter drier when open to environment. But great content, bud
@AB_HVAC
@AB_HVAC 2 ай бұрын
Great point!
@Honestandtruth
@Honestandtruth 2 ай бұрын
Totally makes sense 👍 for drainage
@TomLawson05
@TomLawson05 2 ай бұрын
Great job and troubleshooting thanks for the video
@AB_HVAC
@AB_HVAC 2 ай бұрын
Thanks for watching!!!
@lahoucinelamlih3214
@lahoucinelamlih3214 2 ай бұрын
Great job as always brother
@AB_HVAC
@AB_HVAC 2 ай бұрын
Much appreciated ✊🏽
@markcotter2355
@markcotter2355 2 ай бұрын
first one, The empty house. I think a check on the condenser would be necessary second one with the Rheem, Looks like low charge. subcooling is usually around 10 degrees and that one was at 2 third one the Goodman. I think The Filter drier is clogged. The goodman filter drier is inside the condenser. Are you sure it has a piston? probably a txv. thanks for the videos.
@johnbrooks6003
@johnbrooks6003 22 күн бұрын
Changed a compressor but not filter drier then has issues….hmmm I think I change out filter drier to not have that as another restriction
@drodriguez394
@drodriguez394 2 ай бұрын
put a 3/4 hose cap on your pump discharge to prevent it from spilling in your truck
@scottjohnson7467
@scottjohnson7467 Ай бұрын
HEY man dont sweat forgetting the 24v and possible tripping/blowin a fuse... shit happens, its alot going on. one time i discharged a cap and forgot to turn the power off on this Bryant rtu
@AB_HVAC
@AB_HVAC Ай бұрын
Can't sweat the small stuff at all man. On to the next
@nonamesplease8228
@nonamesplease8228 2 ай бұрын
No new filter drier on a burn out compressor replacement? You will probably be back to replace a plugged drier
@AB_HVAC
@AB_HVAC 2 ай бұрын
It's a good thing that wasn't a burnout, but a ground out. Haven't gotten a call back on the job
@LEEKHVAC
@LEEKHVAC 27 күн бұрын
I’m sorry but I put trane over Goodman any day sorry guys 😂😂 and before yall ask yes I’m a service tech I hate Goodman systems with a passion
@renj6531
@renj6531 Ай бұрын
13:07 man thats one slow fan LOL
@AB_HVAC
@AB_HVAC Ай бұрын
😬😬😬
@renj6531
@renj6531 Ай бұрын
@@AB_HVAC I know it’s a frame rate that’s why I put lol it would be cool if they could move that slow and still function
@AB_HVAC
@AB_HVAC Ай бұрын
Dude that'd be awesome. I mean even the minisplit fans spin "kinda" faster
@MrSmooth302
@MrSmooth302 28 күн бұрын
If the coil is under positive pressure a trap is not needed(blower pushing are through evaporator coil) if the coil is under negative pressure(blower is pulling through air through coil) like most downflow units and air handlers than a trap is needed if not the blower will pull air through the condensate pipe outside and air lock the drain pan. Causing water to overflow in the evaporator drain pan. From my knowledge thats what I’ve always been told
@AB_HVAC
@AB_HVAC 28 күн бұрын
That's what I've been told too, but in rare instances, I've found a few upflow positive pressure drains needed a P-Trap. Not sure if it was a static pressure issue, but I know once that P Trap was on it the system began draining
@MrSmooth302
@MrSmooth302 27 күн бұрын
Agree best practice is put them on everything lol
@AB_HVAC
@AB_HVAC 27 күн бұрын
@MrSmooth302 I love best practices, and I know I don't necessarily do them on every video and or service call but I feel they're virtually useless if everyone at your company isn't doing it, if that makes any sense. It's demoralizing sometimes
@MrSmooth302
@MrSmooth302 27 күн бұрын
Bro I know what you mean. My mentor had a saying when he was trainging me “never underestimate the installers ability to fuck something up” lol
@AB_HVAC
@AB_HVAC 27 күн бұрын
@MrSmooth302 it's not even just installers, sometimes it's the older more experienced dudes
@sheldon8115
@sheldon8115 3 күн бұрын
Restricted piston or strainer
@numchux2
@numchux2 2 ай бұрын
Looks like someone mixed R22/410A on that last system...the R22 doesn't evaporate at the higher suction pressure and it causes this. I could be wrong, but makes sense.
@AB_HVAC
@AB_HVAC 2 ай бұрын
I've never come across something like that before. For more context, the air handler is in spacious closet, sitting on a return plenum with a "grille" opening of about 16x16, the closet also has louvers. So I was under the assumption it needed a bigger return. My boss would say it's been working all this time but in my head, I wonder if that's what helped kill this prematurely. House is also zoned for upstairs and downstairs
@numchux2
@numchux2 2 ай бұрын
@AB_HVAC well compressors are slowly dying the day you start using them tbf...the windings are literally trying to burst away from eachother each startup 😆
@redneckways1617
@redneckways1617 2 ай бұрын
I’m guessing the trap is on the outside on that first unit?… If so then both of those lines have to be capped for the negative pressure drain to drain properly
@AB_HVAC
@AB_HVAC 2 ай бұрын
You'd be correct about the negative if that WASNT a split gas furnace. The drain is under positive pressure on that first one, and to my knowledge, not all positive drains need a trap.
@redneckways1617
@redneckways1617 2 ай бұрын
@@AB_HVAC absolutely correct…I didn’t realize it was a cased coil
@AB_HVAC
@AB_HVAC 2 ай бұрын
You're good. You'd be surprised how many people don't know negative pressure drains need it 🤣
@winstonmartin6179
@winstonmartin6179 Ай бұрын
What is delta t
@Mo4Honesty
@Mo4Honesty 2 ай бұрын
Seems like an obvious restriction. And my guess would be the filter drier. Did you replace it? Did you check it? Video is edited so not all steps are on camera.
@AB_HVAC
@AB_HVAC 2 ай бұрын
No I was instructed not to because it originally didn't pose any issues (yes I understand it's best practice but im not gonna buy something for the job my boss says to not get). In my experience, a restriction pulls down on the suction pressure and increases the head pressure. My best guess was I should've pulled a deeper vacuum maybe. And that's not to say that the filter dryer couldn't be an issue, I just didn't think that from my readings at the time
@Mo4Honesty
@Mo4Honesty 2 ай бұрын
​​@@AB_HVACincreased head pressure is another name for stacking refrigerant on the condensing unit. Adding refrigerant charge to reduce the superheat will INCREASE the evap pressure, which implies you think it was too low before. That's exactly how you just described a restriction. You already have plenty of refrigerant based on SC but it's not all getting through. OR.... maybe the piston is the wrong size or has crud in it?
@AB_HVAC
@AB_HVAC 2 ай бұрын
Yeah I get that, guess what I mean to say is I've always seen a restriction steadily drop suction pressure while increasing head. Where as at the end of the video had fairly high head, and a suction pressure that wasn't dropping. Could that still be a restriction?
@Mo4Honesty
@Mo4Honesty 2 ай бұрын
@@AB_HVAC yes, it could. Think of a water pipe with a slight blockage vs severe blockage. If you flood the opening with water, both cases will back up eventually, but the partial one will not be as noticeable. Or an air filter. Do you think a clean filter, half dirty filter and totally caked filter all have the same static pressure?
@OnePointLander
@OnePointLander 2 ай бұрын
Great job but you will be back to replace that compressor.
@AB_HVAC
@AB_HVAC 2 ай бұрын
🤣 I feel like I am
@emmanuel.alcantara
@emmanuel.alcantara 2 ай бұрын
Next time replace the metering device and the filter dryer. Its best practice
@AB_HVAC
@AB_HVAC 2 ай бұрын
You want me to replace the piston?
@horacegardner3516
@horacegardner3516 Ай бұрын
Dogging Goodman with a Grand Aire hoodie on. Obviously inexperienced.
@AB_HVAC
@AB_HVAC Ай бұрын
Grand Aire is the name of the company I'm proud to work for. We don't install that brand equipment. Tempstar 'round here buddy
Customer LOST FAITH | HVAC | Failed Ruud variable speed Compressor
19:38
Koolin’ with Krauss HVAC
Рет қаралды 9 М.
Khó thế mà cũng làm được || How did the police do that? #shorts
01:00
Running No A/C Service Calls On The Weekend!!! | HVAC
17:18
AB HVAC
Рет қаралды 1,1 М.
No Cooling Service Calls.  Easy Monday Before 4th Of July!
18:11
Jeff’s HVAC Adventures
Рет қаралды 39 М.
HURRY THE AC IS ON FIRE
27:43
HVACR VIDEOS
Рет қаралды 101 М.
Taking What We Learn In Class And Applying It
16:22
AB HVAC
Рет қаралды 1 М.
How Many Calls In ONE Day Is Too Much?? | HVAC Life
14:32
Quality HVACR
Рет қаралды 183 М.
An Unusual No Cooling Call
22:56
HVAC GUY
Рет қаралды 142 М.
HVAC.  RIDE ALONG FOR 3 NO AC SERVICE CALLS
22:18
HVAC OTJ
Рет қаралды 9 М.
Attempting To Use The MeasureQuick App! #hvac
22:59
AB HVAC
Рет қаралды 1,2 М.
AC Is Broken So Was The Owner After The Fall
16:23
HVACR Survival
Рет қаралды 11 М.
Khó thế mà cũng làm được || How did the police do that? #shorts
01:00