Get up to code electrically with your kitchen wiring. Learn how to space your GFCI protected outlets correctly. Learn what dedicated circuits you will need for your renovated kitchen project. If you are installing special appliances that pull more watts then make sure you have the appropriate power pulled for your kitchen renovation. The NEC is constantly changing. Make sure you check with your local building inspector to find out what version of the NEC they follow. And always, for more help visit www.thevirtualelectrician.com
We are here to help you with all your electrical projects!

Пікірлер: 20
@kirkshirley1319
@kirkshirley1319 3 жыл бұрын
Microwave is only required for a dedicated circuit if it is built in.
@TheVirtualElectrician
@TheVirtualElectrician 3 жыл бұрын
This is correct. Otherwise you can plug it into either of the 2 dedicated 20 amp appliance circuits.
@vids595
@vids595 Жыл бұрын
The fridge is allowed to be on 1 of the 2 required branch chain small appliance circuits.
@TheVirtualElectrician
@TheVirtualElectrician Жыл бұрын
This would be stupid and irresponsible. Most newer fridges require a dedicated circuit. Just because you are allowed to do it doesn’t mean you should. Yeah as the electrical contractor you may save a little money but do the right thing and install it on a dedicated circuit
@R900DZ
@R900DZ Жыл бұрын
@@TheVirtualElectrician modern fridges only draw 3-5 amps max, that’s why theyre not required to be on a dedicated circuit.
@TheVirtualElectrician
@TheVirtualElectrician Жыл бұрын
@@R900DZ wrong. Most modern fridges need a circuit for the fridge and one for the freezer. I think we are wiring 2 different houses. I’m guessing the houses you are wiring are less than 400k?
@R900DZ
@R900DZ Жыл бұрын
@@TheVirtualElectrician I’m just saying the NEC doesn’t require a dedicated circuit for the fridge. If the manufacturer of the fridge requires it that’s one thing but the NEC doesn’t. If you go to Home Depot and check out your average fridge you’ll see the amp draw is minimal on the new ones.
@institches2750
@institches2750 10 ай бұрын
​@@TheVirtualElectrician The video suggests wiring your own kitchen to save money. Do you think anyone like that owns a house worth almost half a million dollars? I had my kitchen rewired recently by a licensed electrician. Fridge is one of the two appliance circuits, not it's own dedicated circuit.
@fevgg
@fevgg Жыл бұрын
I have wet bar countertop with island. Sink is located on countertop. As I understood, I need at least 2xGFCI protected circuits at the right and left of the sink. As per code I have to install at least one 20A outlet in the island. I plan to install two outlets. Do they have to have dedicated circuits or I can connect them to existing GFCI outlets on countertop?
@TheVirtualElectrician
@TheVirtualElectrician Жыл бұрын
They can be on the load side of your countertop outlets.
@fevgg
@fevgg Жыл бұрын
@@TheVirtualElectrician thank you
@shanesubashe787
@shanesubashe787 2 жыл бұрын
Did you mean dual 40 AMP circuit for an electric oven? Not 40 volt.
@TheVirtualElectrician
@TheVirtualElectrician 2 жыл бұрын
Yes! 40 amp circuit. sorry. i will have someone edit that!!
@chuethao385
@chuethao385 Жыл бұрын
Quick question minimum 2 small appliances circuits are they referring to the circuit breaker?
@TheVirtualElectrician
@TheVirtualElectrician Жыл бұрын
yes
@chuethao385
@chuethao385 Жыл бұрын
@@TheVirtualElectrician thank you
@vids595
@vids595 Жыл бұрын
Suggesting that a homeowner do their own electrical work is stupid and irresponsible.
@TheVirtualElectrician
@TheVirtualElectrician Жыл бұрын
These videos are made for our electricians. We just upload them to KZfaq so other electricians can learn on their own time.
@dalelehman5194
@dalelehman5194 7 ай бұрын
2 of the smartest people people in the world didn't finish high school, I wired 4 of my own houses and passed with no mistakes I get many good comments from the inspectors. I think you are the stupid one for suggesting otherwise
Electrical Load Calculation | Ugly's Handbook
4:03
TVE
Рет қаралды 64 М.
Пройди игру и получи 5 чупа-чупсов (2024)
00:49
Екатерина Ковалева
Рет қаралды 1,2 МЛН
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 12 МЛН
Pool Bed Prank By My Grandpa 😂 #funny
00:47
SKITS
Рет қаралды 18 МЛН
Won't These Melt?!? 15amp Receptacles on 20 amp Circuits!!!
11:47
Electrician U
Рет қаралды 1,2 МЛН
How to Wire a GFCI Outlet - What's Line vs Load? - Electrical Wiring 101
8:50
Kitchen Counter Electrical - Code Minimum
6:30
Electric Pro Academy
Рет қаралды 36 М.
Should I replace My Kitchen Split-Circuit Receptacles With GFCIs?
13:45
Kitchen islands and peninsulas in the 2023 National Electrical Code
17:14
CEC 2018-Section 26: Kitchen Laying out and wiring a kitchen
12:49
Deanna Littlejohn
Рет қаралды 29 М.
How To Rough In a Switch Box Feeding Lights & Outlets
18:50
Benjamin Sahlstrom
Рет қаралды 643 М.
Пройди игру и получи 5 чупа-чупсов (2024)
00:49
Екатерина Ковалева
Рет қаралды 1,2 МЛН