Next system test I think for the Garage system do the sprinkler overflow. And the house system do the pull station by the panel.
@Flamenmagic2 ай бұрын
That would have been my request, appreciate it Nic, love from the states
@mewing-gawd2 ай бұрын
for june testing: activate the smoke detector in the garage by the garage door activate the pull station by the annunciator in the house
@rjsfire2572 ай бұрын
good one i well vote for you to ✅off by nic
@rjsfire2572 ай бұрын
get this guy nic
@ESTedwards2 ай бұрын
for june test: garage systemtower pull station or shed heat detector (if ROR) house system shed detector or pull station
@nics-systems-electric2 ай бұрын
I'll probably do something different as I just tested that same zone in this month so I'll try something else
@NewEnglandAviaton9872 ай бұрын
@@nics-systems-electricat my house I pulled a BG-12 and EST Siga at the same time
@jodiwarren53812 ай бұрын
Your milk whipper Brinker head with flip a green whip a green bulb in how did the middle house building then do the protect then do the higher ones then you do do only to bring ahead and hide do you garage whip your wand have a great time I’ll be bye 0:22 0:25
@dustinkey8885Ай бұрын
@@nics-systems-electric wire the same light you have on the generator building to both fire alarm systems
@nics-systems-electricАй бұрын
@@dustinkey8885 it isn't a fire alarm device it's used for generator running indication
@That_2_guy2T2 ай бұрын
Cool video as always! I really love the layout of the beginning of the video.
@sirensofsoutheasternlouisiana2 ай бұрын
Nice to see a new video! Good job!
@IanGSully2 ай бұрын
In the Garage I'd say do the smokie by your projector. As for the house maybe one of the heat detectors in the attic or the pull station by the panel. Also, what would be pretty cool is if you had a monitor module that would put the garage panel into supervisory when the generator is running. I guess one way that would work is taking a relay with a 120-volt coil and when the 120 volts from the generator energizes the relay coil, it would close the relay, tripping the module.
@Dawezil2 ай бұрын
14:52 that's the coolest done I've ever seen.
@lutinogamesofficial43472 ай бұрын
Watching this one day after my 15th birthday. Still the best content as always! My suggestions for june testing: for the garage: One of the smokes in the main garage room for the house: The heat in the Garage Keep up the good work!
@nics-systems-electric2 ай бұрын
Thank you happy birthday
@lutinogamesofficial43472 ай бұрын
@@nics-systems-electric thanks :)
@chrisgamecaveАй бұрын
You should expand the 9200 in the garage building to protect the little wood building partially visible at 2:27.
@ResetTheFireAlarm2 ай бұрын
Great video, as always. I just have an idea/suggestion for an addition to the house fire alarm system; a strobe in the bathroom. Just a thought I had.
@nics-systems-electric2 ай бұрын
Well there is 3 bathrooms and I had bought some months ago however it's not possible for them to all be installed due to the location so if it's not possible for all of them I won't do any of them
@TechnologyUnhinged2 ай бұрын
In all this is really awesome!
@BlakeFA_TECH2 ай бұрын
Great job Nick and when we come to May 4 be with you
@jkashs8297Ай бұрын
Next test. For the garage the pull station at the top of the tower. In the house, the pull station by the panel
@washingmachinelad3562 ай бұрын
Nice video Nic! I think you should install running man exit signs to your house building that don't have them for going outside
@nics-systems-electric2 ай бұрын
I talked about that in my video of installing the one in my bedroom. I cannot install them in the house due to the aesthetics of bright green exit signs do not look good in a residential setting.
@pilotboy2 ай бұрын
dang you got a nice stereo system? it would be cool to see a video with the projector going as well! i was wearing the headphones and that sub was pumping!
@nics-systems-electric2 ай бұрын
Yeah I should probably do a video on this set up
@pilotboy2 ай бұрын
@nics-systems-electric if you need some copyright free music to play then @medusakb has a lot of good music to choose from
@TripleH3Ай бұрын
I’d enjoy seeing you continue to kill the main breaker instead of the 3 emergency light breakers for that test. Seems cool when it’s all dark and just the emergency lights.
@Harper_DobniYT2 ай бұрын
For June testing can you do the pull station under the deck for the house and the pull station by the bathroom for the garage?
@NewEnglandAviaton9872 ай бұрын
Next text hit some pulls. The house pull station (main one) and one in thr garage
@JMWtrainsnstuff2 ай бұрын
Whoa!!! "Hue G Rection?!?!?" Lmao nice video as always
@Wire_Tech222 ай бұрын
Very nice testing video Nic!
@KarsonM20112 ай бұрын
Nice lights on the door 1:50
@graysongamer16172 ай бұрын
In garage push drill button on MS-92000UDLS
@nics-systems-electric2 ай бұрын
Drill button can't be used as a functional test
@michaelclark20222 ай бұрын
Instead of pulling the fuse, does the detached garage have a breaker switch you can flip? Up until you put in the toggle switch...
@nics-systems-electric2 ай бұрын
Yes but it's in the house
@CJP_Productions2 ай бұрын
for july or august F/A, UPS, generator testing: house: laundry OR test pull near FACP garage: heat detector in bathroom
@Vortex001_MLG2 ай бұрын
1:54 What are those cool RGB strips that you use? What brand/model are they and how do they work with your system? Really love the white flash startup sequence of those LEDs! 😊
@nics-systems-electric2 ай бұрын
They have nothing to do with my systems but they are Govee M1 light strips and they are quite good compared to the other products I've used previously
@Camporito252 ай бұрын
Yeah!
@The_FireAlarmGuy2 ай бұрын
Nice video 😊🤩😊
@Max_And_His_Tech2 ай бұрын
Yes a new video I love this channel
@benrodriguez49052 ай бұрын
For the next test do the lower outside ahead for the house pull
@najebabdulnoor2 ай бұрын
Next system test do the pull station in the panel room for the house and the garage do the pull station in the storage room
@CameronReape2 ай бұрын
10:03 you've never shared that Jackson is a rescue!
@nics-systems-electric2 ай бұрын
Double rescue
@geomerdash6302 ай бұрын
would you try set your fire alarm systems to continuous in june?
@nics-systems-electric2 ай бұрын
That would require changing the settings on 11 different devices
@Thefreindlytaco58142 ай бұрын
Anyways here is a brownie recipe 12 ounces unsalted butter (about 3 sticks; 340g) 6 ounces finely chopped dark chocolate, about 72% (about 1 cup; 170g) 16 ounces granulated sugar (about 2 1/4 cups; 450g) 2 ounces light brown sugar (about 1/4 cup, packed; 55g) 1 3/4 teaspoons (4g) Diamond Crystal kosher salt; for table salt, use about half as much by volume or the same weight 6 large eggs, straight from the fridge (about 10 1/2 ounces; 295g) 1/2 ounce vanilla extract (about 1 tablespoon; 15g) 1 teaspoon instant espresso powder, such as Medaglia d’Oro (optional) 4 1/2 ounces all-purpose flour, such as Gold Medal (about 1 cup, spooned; 125g) 4 ounces Dutch-process cocoa powder, such as Cacao Barry Extra Brute (about 1 1/3 cups, spooned; 115g)
@BlinkOnWheelsАй бұрын
What about the instructions like temperature of the oven and cooking time?
@Thefreindlytaco5814Ай бұрын
@@BlinkOnWheels 375°F and about as long as it will take time will vary from oven to oven
@Firealarmperson9022 ай бұрын
love the videos nic
@Williams_elektronik2 ай бұрын
Do smoke/heat (i dont rememberd) in the garage in the house. And bathroom in garage
@firesign892 ай бұрын
damn bro, what type of subs do you have for your stereo system
@nics-systems-electric2 ай бұрын
Just one 12" can't remember what model
@Random_Emergency_Light2 ай бұрын
Nice Nic
@Eric_Rosen2 ай бұрын
what if for a generator test switch you cut in a box next to transfer switch to put it and run wire into transfer switch? maybe a key switch
@nics-systems-electric2 ай бұрын
It's still the same problem of having to drill a hole into the side of the transfer switch which is difficult when it's inside the wall and it's a total pain in the ass to try and take it out if I could get some sort of really short 90° drillbit that might be my only option
@ComputersandOtherStuff2 ай бұрын
Do you have to do monthly testing at the schools too? Or is it just something you do?
@nics-systems-electric2 ай бұрын
Yes every system is supposed to be tested monthly
@keithpierce84582 ай бұрын
Yes a new video
@gradyvr14402 ай бұрын
I Love testing
@JaylonbridgesOfficial152 ай бұрын
Nic what good
@Thesystemsensor2 ай бұрын
May 4th be with you day haha
@nickguzman2865Ай бұрын
In June test the pull station by the panel in the house for the garage test the pull station in the system tower
@Justarubberduck2 ай бұрын
Why don't you have a voice evac system? I think if you were to add it it would make it seem more like a commercial building. I've seen little modules you can add to your panel to make them work and wiring speakers w strobes. I just thought of it because my school has a voice EVAC system
@nics-systems-electric2 ай бұрын
In my entire life in Canada I've only seen half a dozen buildings with Voise evacuation it is not common and definitely not necessary the building is not wired for it and it is extremely expensive and unless you're using custom messages it's pointless in my opinion
@thatboatman28 күн бұрын
Is your house system monitored by a company like a commercial building?
@nics-systems-electric28 күн бұрын
Self monitored
@gameranoniem38722 ай бұрын
Hey Nic, can you do the smoke didector from the aircondicening?
@dtcapture2 ай бұрын
for june test: see if your fire alarms can overpower the stereo on full whack :)
@GaryBeltz2 ай бұрын
Are the dogs friendly? Also, how often do you think you'll need to change the battery on the generator?
@nics-systems-electric2 ай бұрын
Ayla is friendly battery probably needs to be changed every 3 to 5 years like any other SLA battery
@HawkeyeAlarms2 ай бұрын
Hey! I suggested a garage tour a long time ago (when you were Pickle 700), have you ever considered the idea or do you have plans for it?
@nics-systems-electric2 ай бұрын
Maybe it's but it's kinda shown in every monthly video
@Max_And_His_Tech2 ай бұрын
can you do the pull station in the security panel / storage room
@hotbytesB2 ай бұрын
When you do June testing start off with the generator testing❤❤❤
@AdamHalberstat2 ай бұрын
You should set off a fire sprinkler in the Grage
@TheJakeman7892 ай бұрын
“Monthly testing, once a month” isn’t that what monthly means? Lol
@nics-systems-electric2 ай бұрын
Something like that lol
@pentiumman3338Ай бұрын
what drone do you use?
@nics-systems-electricАй бұрын
DJI mini 3 pro
@ComputersandOtherStuff2 ай бұрын
20:35 you should add a key switch and put it next to the first door
@nics-systems-electric2 ай бұрын
As I said I intend to install a switch at some point but is difficult to do with it being mounted in the wall
@Jasiri5332 ай бұрын
Next month do the pull tower one
@nics-systems-electric2 ай бұрын
Usually I try and do a different device that would be on the same monitor module
@mbcommandnerd2 ай бұрын
3:17 - That label though…if you know, you know.
@michaelloving80042 ай бұрын
for June test set off duct smoke
@GrahamSinclair-qy7ftАй бұрын
For July test do a no power fire alarm condition that when the panel die get the generator going
@nics-systems-electricАй бұрын
The panel won't die
@t8pguw8ejbwgp9e22 ай бұрын
hi nick whats difference between isolator board I think its called vs a bunch of FDM-1 in a row? when do you use board instead?
@nics-systems-electric2 ай бұрын
FDM-1 is a dual monitor module and is the same form factor as the ISO-X
@t8pguw8ejbwgp9e22 ай бұрын
@@nics-systems-electricis there a board that can be used instead of installing say 6 FDM-1? if you need over 10 conventional
@nics-systems-electric2 ай бұрын
@@t8pguw8ejbwgp9e2 yes monitor modules control modules relay modules and isolator modules all come in a board version
@LinkterTravis2 ай бұрын
Yes may test
@Catnap0192 ай бұрын
Bruh
@benrodriguez49052 ай бұрын
What is the security light for on the panel?
@nics-systems-electric2 ай бұрын
Tamper switch on annunciators or any booster panels or any component of the fire alarm system that needs to be monitored if it's being opened
@benrodriguez49052 ай бұрын
@@nics-systems-electric oh niceeee
@benrodriguez49052 ай бұрын
@@nics-systems-electric good talk
@TripleH3Ай бұрын
I saw that TV on hockey. Are you a hockey fan? (Go Preds)
@timmyvalero202 ай бұрын
Do you test the security system? And I subscribed to your KZfaq channel
@nics-systems-electric2 ай бұрын
Not very frequently
@freddievanfleet17062 ай бұрын
I wish I loved my job so much that I’d elect to spend my own money and time on it at home lol
@DJboogie-eh5vs2 ай бұрын
for vid you should connect your security system to your fire panel in the garage
@nics-systems-electric2 ай бұрын
They are not connected because the security system is not used for monitoring of the fire alarm system
@DJboogie-eh5vs2 ай бұрын
@@nics-systems-electric you should try it so that when the fire alarm goes off it will show up on the security panel
@nics-systems-electric2 ай бұрын
@@DJboogie-eh5vs many have said that but it makes it frustrating to have to reset two systems if there is a way where it's non-latching and doesn't make any noise that would be better
@sherryjustice87122 ай бұрын
Love you
@Neptunesalad122 ай бұрын
Next month do a walk test maybe and cute dogs
@nics-systems-electric2 ай бұрын
I only set off one device per month
@Harper_DobniYT2 ай бұрын
Walk test isn’t legal in Canada
@Neptunesalad122 ай бұрын
@@nics-systems-electric dang well then a heat detector in the garage and a pull station in the house
@Alarmsystems8292 ай бұрын
I want to see a security system test
@nics-systems-electric2 ай бұрын
I've done some before I will do one again sometime
@Max_And_His_Tech2 ай бұрын
What lights do you have on the garage door
@nics-systems-electric2 ай бұрын
Like the bulbs in the opener? They are just some 60 W equivalent 5000 K LEDs or if you were talking about the man door I have the same as the ones on the ceiling in one spot Govee M1's
@Max_And_His_Tech2 ай бұрын
Thank you I like the chase mode on the led strips
@najebabdulnoor2 ай бұрын
Next test do the pull station in the house where the panel is next to the panel the metal pull station
@adventuresquadofficial2 ай бұрын
Hi Nic, Just a question. Do the Reolink Cameras work during a power outage? I am thinking of putting them in my home.
@nics-systems-electric2 ай бұрын
If you have your NVR and any other switches on UPS as I do then it will keep running
@adventuresquadofficial2 ай бұрын
@@nics-systems-electric Ok thank you
@ogrdeuboi2 ай бұрын
hello good content im getting a call point today:]
@Neptunesalad122 ай бұрын
Good for you! Hopefully it will be a return on investment
@gamerboy129702 ай бұрын
Are you recording on your new camera or your iPhone 14 Pro
@nics-systems-electric2 ай бұрын
I showed that in the video I am using both Sony a6700 for some shots and iPhone 15 Pro Max for most
@gamerboy129702 ай бұрын
@@nics-systems-electricalright thank you
@firealarm4212 ай бұрын
Awesome. For your house system test in June could you do the pull station in the shed
@nics-systems-electric2 ай бұрын
Probably will
@fortniteinminecraftt37942 ай бұрын
Hey Nick, I’m here to apologize for what he has been treating you and saying about you sorry
@fortniteinminecraftt37942 ай бұрын
You’re a great man keep going😊
@petra7306Ай бұрын
i love you nic
@sargentmaxis2 ай бұрын
do the smoky in the it in the gen room in house pull in the shed under the stars
@Random_Emergency_Light2 ай бұрын
25:45 exhaust isnt connected
@nics-systems-electric2 ай бұрын
It's within proximity that is sufficient for the exhaust to be directed where they need to go
@Earth_Number_122 ай бұрын
No led L-series low frequency?
@nics-systems-electric2 ай бұрын
I showed seven of them in this video
@Earth_Number_122 ай бұрын
@@nics-systems-electricwhy isn’t the LED l series horn strobe installed
@nics-systems-electric2 ай бұрын
@@Earth_Number_12 why would it be? Can't install something that doesn't exist yet.
@Earth_Number_122 ай бұрын
@@nics-systems-electric I thought you had it already
@nics-systems-electric2 ай бұрын
@@Earth_Number_12 they don't even make it yet
@amaliabujorianu1437Ай бұрын
ok 1:57
@ResetTheFireAlarm2 ай бұрын
35:08 lol
@Max_And_His_Tech2 ай бұрын
Can you do the pull station on the tower next month
@nics-systems-electric2 ай бұрын
I'll probably avoid that zone for next month as it's the same zone I just did
@Max_And_His_Tech2 ай бұрын
Ok
@Max_And_His_Tech2 ай бұрын
@@nics-systems-electriccan you do the one in the security panel / storage room then
@Stihl_theofficer2 ай бұрын
How old do you need to be to watch this next month testing in the garage smoke detector and in the house pull the fire alarm
@nics-systems-electric2 ай бұрын
Any age my videos aren't age restricted
@Stihl_theofficer2 ай бұрын
Ok cuz I'm 10
@wibwabz2 ай бұрын
you always say that EST is bad, but i see so many newly constructed buildings with EST systems so it cant be that bad, right? what makes EST systems bad, especially newer ones?
@ESTedwards2 ай бұрын
EST systems actually aren’t that bad, but their older systems like the QuickStart and the EST2 were really glitchy and bad
@nics-systems-electric2 ай бұрын
You see lots installed not necessarily because it's a good product. mostly the products that are installed in the building depends on who the contractor works with. if they have deals with certain companies and often times electrical contractors have a go to company for fire alarm that will install one product only. sometimes depending on your actual area they're only is a few options for install. cost a factor if EST is cheap to install
@wibwabz2 ай бұрын
@@nics-systems-electric that makes sense.
@Seraiburchgamesandmore2 ай бұрын
11:37 Sounds Like a Low Frequency Sounder
@ResetTheFireAlarm2 ай бұрын
Oh I thought it was a horn
@nics-systems-electric2 ай бұрын
It sounds like one because it is one
@Seraiburchgamesandmore2 ай бұрын
@@nics-systems-electric oh
@joeycaridi30302 ай бұрын
@@nics-systems-electric And at 09:49 whenever you close the door on your Fire-Lite MS-9200UDLS, the door squeaking noise kinda sounds like a low frequency sounder due to the same frequency it makes
@PMBABowlingbrothersPBA2 ай бұрын
My birthday is on May 31st
@Harper_DobniYT2 ай бұрын
Nic I tried to donate but my PayPal isn’t working so take this heart ❤
@nics-systems-electric2 ай бұрын
I appreciate it
@gman13362 ай бұрын
5 min 👇
@theclueguy33882 ай бұрын
Hey Nic just my opinion but it makes me a bit nervous with you using drone footage around your house because it kind of shows the area. No address or street but it makes it easier for bad people to try to find that if they really wanted to and you have a lot of expensive equipment.
@nics-systems-electric2 ай бұрын
It is what it is if they've already found my road then they can already find my house which people have
@fortniteinminecraftt37942 ай бұрын
Hi
@I.D.K.82 ай бұрын
Hello
@sherryjustice8712Ай бұрын
I’m sorry don’t leave me. I want you here with me. I know that your love is gone.
@rjsfire2572 ай бұрын
your pa system be like boooooooooooooooooooooooooooooooooooom
@DJboogie-eh5vs2 ай бұрын
day 1 of asking for a voice demo board vid
@nics-systems-electric2 ай бұрын
Very expensive
@DJboogie-eh5vs2 ай бұрын
@@nics-systems-electric how much
@DJboogie-eh5vs2 ай бұрын
@@nics-systems-electric the panel or alarm fixtures?
@nics-systems-electric2 ай бұрын
@@DJboogie-eh5vs devices are not terrible it's all of the added complexity that comes along with audio with amplifiers and power supplies custom buttons etc.
@petra7306Ай бұрын
Activate your co moniter
@nics-systems-electricАй бұрын
Just did a week ago
@Georgia_firealarms114 күн бұрын
It’s not may it’s July
@nics-systems-electric14 күн бұрын
Huh
@ryancrooks1232 ай бұрын
I Would Request To End The Supervisory Mode I Think Two Separate Fire Alarm Systems Should Both Your Garage Fire Alarm System And House Fire Alarm System Should Both Go Off At The Same Time I Liked That Idea It Would Easier So You Could Just Reset The Fire Alarm Control In Your Main House Instead Of You Going Back To The Garage To Reset The Fire Alarm Control Panel It Would Just Be Easier
@mimi22 ай бұрын
Did you not watch the previous video from 7 days ago? Having the systems trigger each other would require nic to run around to reset both systems before the other is finished initializing.
@nics-systems-electric2 ай бұрын
Clearly haven't watched it… monthly testing videos would be over if I had to deal with that too much of a pain. no system should ever be set up that way. I've worked with them in the field it's not fun requires a person at each panel with communication with each other at all time. And resets have to be coordinated.