A day in the life video blog of a plumber and gas engineer FREE WEBSITE 👉🏽 bit.ly/3Omf8qi Installer show FREE TICKETS 👉🏽 installer-2024-splash.reg.buz...
Пікірлер: 80
@shmurty81864 ай бұрын
not the shavings flying into your coffee as you drilled ... lol
@dmarriott97014 ай бұрын
On the Essex flange,I always used to draw around the external rubber seal before final fixing to give me a position so I new it was all central on final tightening. Good videos, keep ‘em coming
@leegunter29444 ай бұрын
Did you get those copper shavings in your tea doing that flange lol
@robertwhiteoak914 ай бұрын
Poor man's version of goldschlager right there
@andrewperks19414 ай бұрын
You should use a flue brush when installing the flange instead of wire,works very well 👍.
@callum85384 ай бұрын
Solder ring fittings - you've got Lawton fittings, so they will work as designed 🤘 no need to add any solder. Just flux and heat till you see the ring 🤪. I've had cheep ones fail though 💩. I rarely use them anyway but when I do I use ones I can trust 👍
@alexshepherd33084 ай бұрын
Nice sort on the mug of tea whilst drilling Pete 😂 great content to get us ready for what next week will throw at us 👊🏻
@CommercialGasEngineerVideos4 ай бұрын
Thanks from Spain
@caiphus3214 ай бұрын
Hello there Pete! Thanks for another video I do enjoy and learn a lot from them here in 🇿🇦
@ian11044 ай бұрын
Great content as always, not done a Essex flange in ages, Got a Surrey flange to fit on Thursday. Thanks for taking the time to make the video Pete
@SPARKY400T4 ай бұрын
Great video again thanks nice to see you doing regular content again the Essex flange was interesting to see
@fionnan28114 ай бұрын
I get anxious just watching you do it😂
@crplumbing27464 ай бұрын
Great vid again mate keep them coming 🔥🔥
@colin46854 ай бұрын
Solder fittings are good. I add a little bit extra solder if I see its not fully wrapped around, but generally it always does.
@samjohnson53164 ай бұрын
Mate great video as always. I saw so much copper land in your tea drilling the hole in the cylinder 😅
@FlowRight4 ай бұрын
Great vid , You just pull the wire towards yourself firmly when finished on Essex flange it folds the legs back on itself and comes out (as per instructions)
@tomaszr69904 ай бұрын
thank you a great video now my dad knows this
@You-in6lm4 ай бұрын
I can’t even tighten a new immersion in never mind that 😂😂
@SteveN-pw4dj4 ай бұрын
I am a joiner, I normally use end feed joints, but do add solder if I use these Yorkshire fittings , but only a little bit.
@terrywallis6934 ай бұрын
Novice Plumber - i use the self solder rings - havent had any leak (yet) - No need to add Additional Solder
@andrewhoughton26174 ай бұрын
When I’ve done the Essex flange in the past I’ve bent the wire over and tied some string to it as a safety net. And also that wire is designed to bend with a bit of pressure so it just pulls out
@lewib85264 ай бұрын
Always get the problem where hot water not being hot enough when the bath taps are fully open (full flow). Have to open bath tap half way in order for it to be hot enough. I have the same in my house, I changed the plate but still the same. Great info on the temperature rise in boiler manual. 👍🏻
@pauladventure4 ай бұрын
For the extra cost of solder ring over end feed, definitely DONT add solder, once you see the ring appear it job done, if you add solder just buy end feed 😂
@kriskay27714 ай бұрын
I hope you didn't drink that cup of tea after drilling that hole in the cylinder.😂
@benregler98724 ай бұрын
Only ever installed Surrey flanges. Never fancied fitting an Essex
@Dan-Athema4 ай бұрын
Just gotta make sure you use protection
@dw_plumbheat4 ай бұрын
Worth watching just for the joke at the end 🤣🤣🤣
@davidceredig-evans87724 ай бұрын
The scariest thing about the shower flange install is trusting in that old gate valve on the tank feed!
@FS00444 ай бұрын
Do an updated van tour, I’ve just bought my first van and need some racking ideas!
@joshuabest1004 ай бұрын
Taunting the laws of physics with that wire and copper
@kevinisaac91394 ай бұрын
I allways use a Surrey flange no problem 👌
@daljitsingh5493 ай бұрын
I've done a couple, on my first one, i dropped the flange.
@gmtplumbing85593 ай бұрын
I’m sure it says in the instructions that the pipe should extend through the flange to the center of the cylinder
@CoolMusicToMyEars4 ай бұрын
0:46 try flexible hose on the inside of the adapter, like silicon (dry no oil tight fit) pass washer over it then when its tight nut on pull the tube out of the centre unit
@mcfly101464 ай бұрын
You should do a vid trying to get the brass body back out once it’s fallen in, id pay to see it 😅
@user-zz1mt6nj1r4 ай бұрын
Same as one off your other comments flue brush it’s so much easier and no squeaky bum time
@fionnan28114 ай бұрын
When I install a cylinder I join the hot outlet into a tee where the drain off is located. The result is completely even heat from top to bottom. (Destratification)
@digger80904 ай бұрын
The swarf from drilling the hole in that cylinder was going into your cup of tea below it,great content,how can I drain down my indirect copper cylinder for tic tank to take it out when there is no drain off,please advise
@wirdy14 ай бұрын
Haven't watched for ages; forgot how good your vids are. Cheers for doing them.
@cophater2984 ай бұрын
plumbing saved my life
@cliveramsbotty60774 ай бұрын
no problem if you drop the flange in by mistake, just turn the cylinder upside down and shake it
@paul_my_plumbs_uk4 ай бұрын
Copper ❤❤❤ made from the ❤
@formyloveification4 ай бұрын
Hi PB it’s just out of from this plumbing video, I noticed will you doing this copper tank hole those copper bits was going in your coffee Please be careful mate
@ianchristie71534 ай бұрын
copper shavings in your tea!
@peterwhitehouse52344 ай бұрын
hi Pete am I right (remember from college water regs) that the cold supply shouldn't come from the mains and needs to be tapped into below the hot tapping in tank . because if someone turns off water supply would just have scouding water coming through shower ? I never hear anyone say or mention this when see shower fitted .
@joshuabest1004 ай бұрын
Hope you didn't want that coffee or tea 😆
@YoutubeHero6664 ай бұрын
haha I was just about to say how was the coffee :)
@barrydoherty6364 ай бұрын
Can you run your hot and cold direct from your bath to the loft, to feed your new digital shower?
@poorfordtransitowner16274 ай бұрын
Drilling with a wholesaw....you never know if its coming off an being lost forever
@paul_my_plumbs_uk4 ай бұрын
I'm an Essex flange 😂😂😂😂i live in Romford Essex 🎉🎉🎉🎉
@vincenzovecera53384 ай бұрын
Always add solder, those aren't propa Yorkshire fittings
@richardhayward46434 ай бұрын
I am a Plumbing & heating engineer. And I’m considering the purchasing a press fitting tool. I have folded your channel for some time now and think it’s great. I would value your opinion on which press tool to buy. Alpha ? Novapress? Milwaukee? Rothenberger? Keep up the great work. Regards Richard
@stephenharris55194 ай бұрын
Vault boy and bioshock wallpaper… I’m being to suspect you’re a secret gaming nerd Pete. Have you seen the Fallout tv show that’s out in April ?
@stevenmanning29344 ай бұрын
Do you ever use those bacho 15mm benders you used before?
@galaxydave694 ай бұрын
Connect the wire to your roll of solder
@loojepson63083 ай бұрын
Hey Mr PB, Totally unrelated to this video, got a mate with a noisey T6 coming from the dash, and remember you had something like this, can you remind me what video, and what it was in the end? Thanks in advance👍🏼
@Ken_Myette4 ай бұрын
With all that masonry. How to you insulate your homes? Or do you at all?
@alanwoods40234 ай бұрын
Clean well and flux properly you will not need to add solder..
@chrisb40094 ай бұрын
I like the idea of reading but it’s about £50/guy per month which soon adds up.
@olympusplumbingheating50274 ай бұрын
I use Yorkshire fittings but I also add solder 👍
@bigdmed9553 ай бұрын
Did you flush the fillings out of the tank?
@QuadcopterAnalyze19804 ай бұрын
I always ad solder
@ImHowardMoonsir14 ай бұрын
What happened to the REMS press gun?
@richardlewis53164 ай бұрын
I couldn't understand why the pump was in the loft and not in the cylinder cupboard so you could take the feed off the household feed pipe so no air would get in
@melvinanezi92364 ай бұрын
The manufacturer has gone to great lengths to add just the right amount of solder in the ring of the fitting. Why is it that people feel the need to flood the fitting with more solder? I don’t personally use solder ring myself much but when I do i definitely wouldn’t add more solder never have and I’ve never had a problem when using them with just the solder that’s within the fitting itself. Clean flux apply heat job done.
@EliteHydronics.4 ай бұрын
Brilliant ep. We're get some new stock press valves out to you :)
@JohnMachin-pr5xw4 ай бұрын
If I'm honest you didn't clearly show the installation of the boss clearly good tool your using though on your press fittings!!
@treecutter18062 ай бұрын
Gone again hope the old brain box is ok
@tonymurff52344 ай бұрын
🤜🤜👍🤠
@fionnan28114 ай бұрын
The presoldered fittings are brilliant. I never had any problems with them and never had to add solder.
@davidpembrooke39294 ай бұрын
I've always used reel of solder and taken the immersion out feed it through and then no risk of dropping it inside
@MrMedicalUK4 ай бұрын
I wanna invent a tool to help with that job.....think there is any point?
@povliamrides4 ай бұрын
How many bits went in your coffee
@lawrencepeters41394 ай бұрын
Great VIDEO When I do this I take the immersion out and feed a piece of solder through and out of the new hole this way you can cut A smaller hole. If using solder ring or not always ad solder they should be alright if you get a nice ring of solder around the joint. Regards Lawrence PETERS
@galaxydave694 ай бұрын
But does the absolute shite nova press app work correctly on your press tool
@leerobinson99694 ай бұрын
You don’t add solder as there integral capillary cooper fittings. No solder needed but you will need to clean both end of cooper pipe and fitting. Use flux to help the solder flow and join the two surfaces together. Hope that helps 👍
@ianredfern91684 ай бұрын
Why are you fitting it the air bubbles track the side of the cylinder to top. Shower pump attachments have tube that takes water from away from the side
@vincenzovecera53384 ай бұрын
Are you sole trader or limited
@glynstorer32694 ай бұрын
Squeaky bum time Essex flange on a cylinder
@robbinbanks13114 ай бұрын
Hope that was not your cup of tea there it was getting bits of copper in it 😅