Part 10 - Drain Pipe Plumbing Installed In Second Story Home Addition With Two Bathrooms

  Рет қаралды 148,384

gregvancom

gregvancom

Күн бұрын

Пікірлер: 170
@danieldebreczeni7021
@danieldebreczeni7021 2 жыл бұрын
Sign me up for the supply plumbing, I love how straight forward and educational in real world scenarios your channel is. Thank you
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@dalehall2606
@dalehall2606 Жыл бұрын
@@gregvancom just make sure that people understand that if you roll up 45 or 22 degree that fixture has to have a vent on same plane as fixture or your breaking vent.
@dreaarm14
@dreaarm14 2 жыл бұрын
Newbie here. I have a degree in biology but love to do home projects! Thank you for making such great lectures ! Never realized how fascinating and technical plumbing is.
@gregvancom
@gregvancom 2 жыл бұрын
You're welcome and keep learning.
@Actrights
@Actrights 2 жыл бұрын
Thank you for the video, It was helpful. I noticed that you have a sanitary tee on its side connecting the shower & sink to the toilet which is not permitted. On the 2nd floor you use a wye for the vent, It looks like the fittings were just used in the wrong place. The 3x3 by 2 wye fitting on the 2nd fl should be on switched with the one on the 1st fl. Then use a bushing and vent 90 on the 2nd fl slightly rotated. With your space constraints it might benefit stepping the 2nd fl tub pipe down to 1 1/2 also using a sanitary tee with a 1 1/2 vent 90 which gives you a tight turn giving you more clearance where you have space constraints. I hope these comments are taken the wrong way I really appreciate your videos they are informative and I learned from this video as I do all you're videos.
@gregvancom
@gregvancom 2 жыл бұрын
I checked it out and it looks like I need to redraw the fitting or I might have grabbed the wrong one. I did make another video with part descriptions that might be more helpful. kzfaq.info/get/bejne/j7lopbWHzaepe6c.html I also appreciate the way you made your suggestions and let me know if you find any problems with my videos.
@jamesmateush2709
@jamesmateush2709 2 жыл бұрын
Yes! All your insight into water supply would be great!
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@gregvancom
@gregvancom 2 жыл бұрын
Here's the water supply video and thanks to everyone who voted - kzfaq.info/get/bejne/gbCqm5WnqJu8emw.html Here's a video for those interested in the name of fittings. Part 11 - Plumbing Parts And Fitting For Second Story Home Addition - Do It Yourself Tutorial kzfaq.info/get/bejne/j7lopbWHzaepe6c.html
@2099Darius
@2099Darius 2 жыл бұрын
This is incredible! Thank you for another great video! I wilk be doing a 2 story garage addition to my house either mid 2022 or 2023. The information here is really great! If i could subscribe twice i would!
@gregvancom
@gregvancom 2 жыл бұрын
Best of luck and you're welcome.
@fultonlopez7846
@fultonlopez7846 6 ай бұрын
You are awesome, my daughter and i watch it together
@gregvancom
@gregvancom 6 ай бұрын
Awesome! Thank you!
@CivilianDan
@CivilianDan 2 жыл бұрын
I definitely would like to see the water supply system.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@mikechaz1643
@mikechaz1643 2 жыл бұрын
Great visual , excellent clear descriptions Evon professional ! Please make rough plumbing vedio
@gregvancom
@gregvancom 2 жыл бұрын
Noted
@softde
@softde Жыл бұрын
Off course, we want to see it.
@dannybriggs127
@dannybriggs127 2 жыл бұрын
Nice to see more on plumbing how to. Thank you.
@gregvancom
@gregvancom 2 жыл бұрын
More to come!
@bsyren1
@bsyren1 Жыл бұрын
I would really like to see topics dealing with wet venting. Many times, because of foundation layouts and floor joists, the only solution is to went vent .
@gildardomerancia5818
@gildardomerancia5818 9 ай бұрын
EXCELLENT video you explained very well everything Thank you !
@gregvancom
@gregvancom 9 ай бұрын
You are welcome!
@Straycurrent
@Straycurrent 2 жыл бұрын
Thanks for your video. Count me in for the water too.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@cagaleched3459
@cagaleched3459 2 жыл бұрын
Water lines would be a nice addition to follow up this video..
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@Jadengome3351
@Jadengome3351 11 ай бұрын
don't connect the tub drain to the toilet stack, that creates a lot of sewer gases from the toilet. better to rough in the lines individually
@al95hl50
@al95hl50 Жыл бұрын
Thanks
@oneness7777
@oneness7777 2 жыл бұрын
This is another great video, I would live to see the supply plumbing.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@friendlybill6109
@friendlybill6109 2 жыл бұрын
Please do the water supply video. These videos are very useful. Thanks
@gregvancom
@gregvancom 2 жыл бұрын
Noted!
@duongnguyen-xm9nf
@duongnguyen-xm9nf 2 жыл бұрын
Build home soon and your video is very informative! More please!?
@gregvancom
@gregvancom 2 жыл бұрын
Thank you! Will do!
@johntapolcai4175
@johntapolcai4175 2 жыл бұрын
Great videos. Would love to see the water line layout.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@rb2512
@rb2512 2 жыл бұрын
Your videos are truly amazing.I would be definitely interested in knowing some of the dimensions for the drains and also for water lines.Ex. Measurements on hight of sink drain or height of where to put stub outs for water lines for a sink etc.
@gregvancom
@gregvancom 2 жыл бұрын
Great suggestion!
@antman3525
@antman3525 2 жыл бұрын
Logical thinking at the start makes it easier to fix unexpected things, and if there was any, likely to be minor. No one wants to do a rebuild from a missed problem.
@tallpaul8880
@tallpaul8880 2 жыл бұрын
I would be interested to see the water supply system. Thanks for your channel! ✌🏻🇺🇸
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@jessehernandez7749
@jessehernandez7749 Жыл бұрын
Nice work .. I'd like to see water line set up.
@gregvancom
@gregvancom Жыл бұрын
Noted!
@user-ym5wt2ld4q
@user-ym5wt2ld4q Жыл бұрын
Thank You!
@gregvancom
@gregvancom Жыл бұрын
You're welcome!
@abecarpenter5108
@abecarpenter5108 11 ай бұрын
good job man water riser i would like to see if you can also thank you
@pedropereira8924
@pedropereira8924 Жыл бұрын
Thanks i really, i like it
@gregvancom
@gregvancom Жыл бұрын
You're welcome 😊
@noahbrewster8263
@noahbrewster8263 5 ай бұрын
Thank you!!
@gregvancom
@gregvancom 5 ай бұрын
Welcome!
@MrSidhujatt11
@MrSidhujatt11 2 жыл бұрын
good work
@mohamadmoadeli1097
@mohamadmoadeli1097 Жыл бұрын
Thank you for sharing video I,I had noticed a several things needs to fix it .sanitary T on the side ,needs why also for vet went you can not roll that at the 45 degree angle should be on the same horizontal line with just 1/4 grade, another thing on the change in direction of the horizontal develop length can't be more that 2 ×45
@gregvancom
@gregvancom Жыл бұрын
You're welcome and feel free to point out the other 4 problems:) Some one already mentioned the roll in the wet vent, which is the only problem I found after making the video and will be making a follow up video to correct it. As far as the san tee, it's a combo sweep, but I would appreciate any plumbing codes you have on the 2- 45 connecters instead of a long sweep connector.
@joecox9958
@joecox9958 8 ай бұрын
thanks! where is you water system video?
@edgarm9020
@edgarm9020 2 жыл бұрын
Great video!
@alejandrorivera1782
@alejandrorivera1782 Жыл бұрын
I love your channel.
@gregvancom
@gregvancom Жыл бұрын
Glad you enjoy it!
@Samalva93
@Samalva93 2 жыл бұрын
Love the video! Great info thanks
@gregvancom
@gregvancom 2 жыл бұрын
Glad you enjoyed it and thanks for letting us know!
@Affordablebath_remodel
@Affordablebath_remodel 2 жыл бұрын
always well-done videos.
@gregvancom
@gregvancom 2 жыл бұрын
Thanks
@joecox9958
@joecox9958 8 ай бұрын
I have a straight down 4" ABS and fell the drop force might be too strong and though a slight turn on middle would be better - comment for you mentioned the part. I now consider my kitchen sewer goes above floor under kitchen cabinet (4" kick foot area), goes bathroom to merge to tub/toilet where are the only sunken area of slab foundation - I mean I don't pour concrete on bath sewer but leave small crawl or no crawlable space for them. Any suggestion?
@stevenpape8154
@stevenpape8154 Жыл бұрын
Please make another video!
@yueqihu
@yueqihu 2 жыл бұрын
Thank you for the video, it is very helpful for home DIYer
@gregvancom
@gregvancom 2 жыл бұрын
You are welcome and thanks for letting us know.
@jhonasalazar8995
@jhonasalazar8995 15 күн бұрын
Hi so im doing a ADU GARAGE CONVERTION so my father in law installing vent pipe for the toilet cut the wall in 2 pieces t wall its a 2x4 I dont think inspector will aprove that right? Or would he?
@Ioang40
@Ioang40 11 ай бұрын
What should be done if a house has no air vents anywhere. Will installing air admittance valves on all 3 bathroom sinks and 1 kitchen be ok ?
@leekeen1222
@leekeen1222 9 ай бұрын
can a 3 in long sweep combo wye be used to connect the 2nd floor DWV horizontally to the vertical 3 in vent pipe coming up from the 1st floor DWV plumbing and then continue the vent vertically thru the roof?
@ryankahlor3563
@ryankahlor3563 Жыл бұрын
Thank you
@gregvancom
@gregvancom Жыл бұрын
You're welcome
@juanlucas5162
@juanlucas5162 Жыл бұрын
Yes you can lay it flat but pick up the toilet first, is called horizontal flat venting only 1 vent for all one complete bathroom, this is for California not to many company’s does it but mine does.
@LSaunders4321
@LSaunders4321 9 ай бұрын
Ty horizontally laying down second story
@gregvancom
@gregvancom 9 ай бұрын
Yes.
@donnadelaparra6433
@donnadelaparra6433 2 жыл бұрын
great video
@gregvancom
@gregvancom 2 жыл бұрын
Thanks for the visit
@leekeen1222
@leekeen1222 9 ай бұрын
also i would like to then connect the 1st floor 2 in sink vent to 3 in stack above the 2nd floor horizontal to vertical combo wye described in previous post
@gregvancom
@gregvancom 9 ай бұрын
You can't connect drain to vent. See if this helps kzfaq.info/get/bejne/j96Tl8yixs7IeYU.html
@leekeen1222
@leekeen1222 9 ай бұрын
how do you connect 2nd floor DWV to 1st floor DWV? Do you have to run a separate stack just for venting?@@gregvancom
@tallybobba
@tallybobba 2 жыл бұрын
I think the closet wall could be built with 2x6 and the plumbing then ran down the wall rather than through the ceiling and then down the wall. I believe the other bathroom plumbing could still be hooked up. Interior wall could be built to accommodate the plumbing
@gregvancom
@gregvancom 2 жыл бұрын
Go for it.
@cepedacarlos2
@cepedacarlos2 Жыл бұрын
This how ok for Texas plumbing
@rgentbuilders
@rgentbuilders 2 жыл бұрын
Would love to see the water line layout. Pex?
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@ahmedjalal3199
@ahmedjalal3199 2 жыл бұрын
Pretty simple …if I have to reroute the pipe running above the basement ceiling,I have to use 2(45 deg )to achieve 90 deg ???? Thank you for answering
@gregvancom
@gregvancom 2 жыл бұрын
I'm not sure what you're doing, but would suggest contacting your local building department for more information or email me a picture.
@joel6427
@joel6427 2 ай бұрын
When gluing the components together, can you force the pipe to the 1\4" per foot needed?
@gregvancom
@gregvancom 2 ай бұрын
Not really, but I've made it work before.
@joel6427
@joel6427 2 ай бұрын
@@gregvancom How else can the 1/4" per foot be met?
@jfh243
@jfh243 6 ай бұрын
Dirty arm for the bathroom vanity upstairs, avoid the line coming out of the floor.
@gregvancom
@gregvancom 6 ай бұрын
I made mistake, just connect wye horizontal to use as wet vent. If this is not what you meant, provide more details.
@d.brionebey9711
@d.brionebey9711 2 жыл бұрын
The wall behind the tub and shower valves should be bear . If you ever needed to change the valves or housing you would have a sheet rock wall to cut into replace sheet rock or put a vent . This avoid having to cut shower stall material such as marble man-made marble or tile . It’s easy for plumbers to get into the back and reinstall for maintenance any vowels or housing that need to be done they can’t be done in the tub or shower area . Always put shut off valves underneath sinks and kitchen sinks water supplies . This makes plumbing work easier for the plumbers with a lot less labor time .
@chani4974
@chani4974 Жыл бұрын
Can I prolong the drain pipe 4:57 to have two toilets a few feet apart sitting on the same drain pipe? Thanks alot for it all!
@gregvancom
@gregvancom Жыл бұрын
I would check with your local building codes first, but I've seen more than one toilet on 3 or 4 inch horizontal drain lines.
@geroldfirl
@geroldfirl Жыл бұрын
Those are very long horizontal runs on some of the drain lines. Could that be a problem? Did you say there is actually a 1/4 inch per foot downslope on those horizontals?
@gregvancom
@gregvancom Жыл бұрын
Yes, a 1/4 minimum is a good slope for all pipes. You should check with your local building department to figure out if long runs will be allowed. Most of the time they allow up to 75 or 100 feet before requiring a clean out.
@IdahoSnake-A-Drain
@IdahoSnake-A-Drain 2 жыл бұрын
Let’s press forward
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@christopherhenson400
@christopherhenson400 2 жыл бұрын
Great video! At 4:18, it appears there is a 4"x2" santee on it's side? To pass inspection, would a 4"x2" combo be better served here? Keep up the good work...love the vid!
@gregvancom
@gregvancom 2 жыл бұрын
kzfaq.info/get/bejne/j7lopbWHzaepe6c.html I made a video with parts list, just in case someone didn't like my parts. Thanks for helping.
@juliancastro6643
@juliancastro6643 Жыл бұрын
its fine if its vertical
@coopermackey4938
@coopermackey4938 2 жыл бұрын
At 5:30 the way you have the toilet plumbed in if someone ran a sewer machine to far and up that wall it’d shatter the toilet. It’s best if possible (and I understand sometimes it’s not) to have it where a sewer machine would travel up a vent stack
@gregvancom
@gregvancom 2 жыл бұрын
Oh yes and if possible, always run the snake in the same direction as the flow of drainage waste. I remember someone sharing a story with me about a drainage snake that came out of a sink and destroyed part of the bathroom.
@coopermackey4938
@coopermackey4938 2 жыл бұрын
@@gregvancom ooof that’s rough lol
@montanalivin8248
@montanalivin8248 Жыл бұрын
The current code states that the only clean outs you need are on waste stacks, kitchen sinks, and foot vents for island sinks. I would still install c/o's on washing machines and urinals. Bottom line, a readily accessible c/o will never be a bad thing. The more the better. Do not ever use a santee on its back. Always use a wye or a combination tee wye for a vent fitting.
@gregvancom
@gregvancom Жыл бұрын
The installation of clean outs usually have a few more rules.
@johnpeters9903
@johnpeters9903 8 ай бұрын
At 7:03 that unwashed horizontal vent below the flood rim of the tub is a violation.
@gregvancom
@gregvancom 7 ай бұрын
Can you explain more of provide building code reference numbers.
@jonathansantoyo7961
@jonathansantoyo7961 Жыл бұрын
Hi . Can you make a video about a raised foundation house plumbing
@gregvancom
@gregvancom Жыл бұрын
I have some at our website. www.homebuildingandrepairs.com/home_building/index.html look for house building projects.
@aaronbaraiya3692
@aaronbaraiya3692 2 жыл бұрын
have you made a decision on making a water supply line video? I would love to see it, thanks :)
@gregvancom
@gregvancom 2 жыл бұрын
Not yet, I still think we need more votes in the comment area.
@aaronbaraiya3692
@aaronbaraiya3692 2 жыл бұрын
@@gregvancom including mine I counted 20 votes
@gregvancom
@gregvancom 2 жыл бұрын
@@aaronbaraiya3692 Thanks for counting and here's you're video - kzfaq.info/get/bejne/gbCqm5WnqJu8emw.html
@aaronbaraiya3692
@aaronbaraiya3692 2 жыл бұрын
@@gregvancom oh wow, great thanks for all your hard work man!
@rogermoring6027
@rogermoring6027 Жыл бұрын
The tee that does not protrude through the wall is that a test tee?
@gregvancom
@gregvancom Жыл бұрын
If it's a clean out, then they can be used for testing.
@rb2512
@rb2512 2 жыл бұрын
We need a water supply video with the dimensions,please.
@gregvancom
@gregvancom 2 жыл бұрын
Got it.
@chrisviolette8991
@chrisviolette8991 8 ай бұрын
Why the wet vents?
@lawrencedigiovanni9004
@lawrencedigiovanni9004 11 ай бұрын
Are you a Plumbing engineer or master plumber.
@gregvancom
@gregvancom 11 ай бұрын
General Contractor who helps master plumbers and plumbing engineers.
@inquizative44
@inquizative44 2 жыл бұрын
I live in an apartment building in which my bathrooms soil stack pipes are being replaced along with the apartment above. The pipes are is being installed below the support beams which will make the ceiling too low, the minimum is 8ft. Running the soil stack pipes below the beams in my bathroom will make my ceiling about 7'5 inches at best with the sheet rock ceiling. I'm no plumber, but why me as a novice can see it (and I warned them) but the plumbers can't? Do they know something I don't? I would love to send you a picture!
@gregvancom
@gregvancom 2 жыл бұрын
You would need to check with local building codes, but most minimum ceiling heights will be around 7 feet.
@inquizative44
@inquizative44 2 жыл бұрын
@@gregvancom Thanks for responding. I did find out, and it's a minimum of 8ft. Just found out by the plumber as I suspected that ceiling will now be about 7'5 inches at best. I warned them, so when the building inspector comes to assess the work completed, I imagine there will be code violations. Oh, and the landlord showed up to take a look. It's on him.
@vallanvhaylock6118
@vallanvhaylock6118 Жыл бұрын
Yes please water system
@gregvancom
@gregvancom Жыл бұрын
It should be on our playlist for this series. kzfaq.info/get/bejne/gbCqm5WnqJu8emw.html
@Addicted2outdoors
@Addicted2outdoors 2 жыл бұрын
Let’s see the water supply!
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@joshuacassino7297
@joshuacassino7297 2 жыл бұрын
How would bathrooms that are on top of each other look? Confused on the toilets
@gregvancom
@gregvancom 2 жыл бұрын
I don't have a video on that but put it on my list of videos to be made.
@joshuacassino7297
@joshuacassino7297 2 жыл бұрын
@@gregvancom could the toilets share same vent?
@kingcountydee
@kingcountydee 2 жыл бұрын
Hello how long can a drain vent run horizontally before going vertically up to the roof? Is there a maximum feet for venting.? Using 2” ABS pipe I’m not a plumber I hope my question make any sense.
@gregvancom
@gregvancom 2 жыл бұрын
This isn't an easy question to answer, because is going to depend upon design and layout of the other plumbing pipes. However, I think it's safe to say that as long as you're not going to making it longer than 5 feet, then you might be safe for practically any situation with a 2 inch pipe. Check with your local building department for clarification on using longer pipes.
@kingcountydee
@kingcountydee 2 жыл бұрын
@@gregvancom So the reason I’m asking is because I want to add a bathroom downstairs and there’s an exiting vent that runs up to the roof. The exiting vent is capped off about 20ft away from where I want to add the bathroom. I was thinking to add a sewer injector pump and connect that to the exiting 3” drain and run 2” ABS to the exiting vent that is 20’ away before it elbows up through my upstairs wall to the roof. I guess I can install a new vent but didn’t really want to make a hole on my torch down roof. Any thoughts on that? Thanks!
@marioflores7002
@marioflores7002 2 жыл бұрын
water supply! Thanks!
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@TuanNguyen-pp4uo
@TuanNguyen-pp4uo 2 жыл бұрын
Can you do a wet vent for a toilet in basement?
@gregvancom
@gregvancom 2 жыл бұрын
Probably not. Email me a picture of what you're trying to do and I will provide an opinion. You can get our email address at our website.
@tammylynn7397
@tammylynn7397 Жыл бұрын
Please help autoimmune disease brain cancer by the old home. The stink pipe coming out of the main sewer line is only about 2 foot tall and is releasing gas into my basement. Need help to understand how to fix it properly. Please help me ASAP would be very grateful God bless you.
@gregvancom
@gregvancom Жыл бұрын
Cap it, extend it up through the roof or try installing an air admittance valve. I would extend it if possible.
@davidmarsh3750
@davidmarsh3750 2 жыл бұрын
Quick question ... on the second story drains, you run a vent by turning a fitting 45 degrees, going up a few inches, and then running a horizontal pipe in the joist bay to the wall before going vertical to the roof. Is this an exception to the no horizontal vents unless 6 inches above the flood line of the appliance, in this case the rim of the toilet?
@davidmarsh3750
@davidmarsh3750 2 жыл бұрын
For clairification, at the 7:06 mark you state vents cannot be horizontal, you have to angle it up at least 45 degrees, but then shortly after that the vent pipe runs horizontal in the joist bay to the wall before going vertical again. I would like to do this exact thing on a second story bathroom remodel, but not sure if it violates the 6" above flood rim level for horizontal dry vents? Thank you for any help!
@gregvancom
@gregvancom 2 жыл бұрын
First, I would like to thank you for bringing this to my attention. What I should've said is that the vent pipes cannot come off of the drainpipe perfectly flat and will need to have some slope to it. As far as the 6 inches above the rim of a sink goes, this is usually going to be the standard for any situation where you have another plumbing fixture vent connecting into another vent pipe. The vent pipes can be ran horizontal and sloping 1/4 of an inch per foot towards the drainage pipe system.
@davidmarsh3750
@davidmarsh3750 2 жыл бұрын
@@gregvancom Thank you for the reply! I am putting in a bathroom (WC, lav, BT, shower) over my garage. I have 16" deep wooden I-joists so I have plenty of joist space, and I would rather not drop the drains into the garage ceiling space. I am concerned with the local inspector citing IPC 905.4: "Vertical rise of vent. Every dry vent shall rise vertically to a point not less than 6 inches (152 mm) above the flood level rim of the highest trap or trapped fixture being vented." Maybe there are exceptions ("structurally feasible", etc) that I do not know about, but I do not see how the dry vent can be run horizontally in the joist bay and still be compliant with 905.4. I think I can either run a wet vent from the lav or get creative in routing and get vertical dry vents run until above the flood rim. The problem is having a good vertical wall close by, so the drain pipes may have to have longer runs than I would want to accomodate the vents. I am not a licensed plumber so I want to be ready for any questions the inspector may have for me. If you can think of any code work arounds for horizontal dry vents below the flood level, please let me know. Thanks again, and your videos are very helpful!
@mattgrizz1153
@mattgrizz1153 2 жыл бұрын
Water supply system. Thank u
@gregvancom
@gregvancom 2 жыл бұрын
Counted.
@harryohanian
@harryohanian Жыл бұрын
is the toilet drain in the same drain as the sink with one vent considered a wet vent?
@gregvancom
@gregvancom Жыл бұрын
See if this helps kzfaq.info/get/bejne/aa2mjMt5u9q0opc.html
@ivansu6076
@ivansu6076 2 жыл бұрын
would like to see water supply!
@gregvancom
@gregvancom 2 жыл бұрын
Noted and we're almost there.
@jamesarruda5960
@jamesarruda5960 Жыл бұрын
Just as a note. Clean outs are not required on a second story or higher
@gregvancom
@gregvancom Жыл бұрын
Maybe not for all vertical drains, but for horizontal like those in floors.
@MerchantNation
@MerchantNation 2 жыл бұрын
water supply👍👍👍
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@randallo3614
@randallo3614 Жыл бұрын
How do rats or snakes get into plumbing?
@gregvancom
@gregvancom Жыл бұрын
Good question. I've seen them come out of toilets and open sewers, so maybe any opening in the plumbing drains would provide easy access.
@cagaleched3459
@cagaleched3459 2 жыл бұрын
Prices went down fir a little while, but now there going back up again
@gregvancom
@gregvancom 2 жыл бұрын
Bummmmmer.
@DrStinkie
@DrStinkie Жыл бұрын
🤣$250,000 PVC coupling!! No kidding
@petermac7095
@petermac7095 2 жыл бұрын
Water supply please
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@ryanbeutler7469
@ryanbeutler7469 Жыл бұрын
I don’t think you can put a santee on its back your better off using a comby fitting
@gregvancom
@gregvancom Жыл бұрын
No it's a combo wye, I made another video naming the fittings and I am planning on updating this video.
@jrc630
@jrc630 2 жыл бұрын
Gas supply!!!!
@gregvancom
@gregvancom 2 жыл бұрын
I will consider it.
@Plasmax-jp6pm
@Plasmax-jp6pm Жыл бұрын
U can't say master bedroom that's racistaaaaa reeeeee
@gregvancom
@gregvancom Жыл бұрын
Sorry:)
@danieldebreczeni7021
@danieldebreczeni7021 2 жыл бұрын
Sign me up for the supply plumbing, I love how straight forward and educational in real world scenarios your channel is. Thank you
How Your Home Plumbing Works (From Start to Finish) | GOT2LEARN
7:06
Yum 😋 cotton candy 🍭
00:18
Nadir Show
Рет қаралды 7 МЛН
When you discover a family secret
00:59
im_siowei
Рет қаралды 22 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 17 МЛН
Plumbing a bathroom explained in 4 minutes. [You CAN do it!] #diy #plumbing
4:20
Rising Tide Plumbing
Рет қаралды 369 М.
Part 1: Plumbing code - waste and venting pipe size
13:15
The Plumbing Academy, Inc.
Рет қаралды 480 М.
4 Plumbing Tricks I Haven't Seen Before!!!
9:19
Matt Risinger
Рет қаралды 1,8 МЛН
Washing Machine Box
11:26
Plumbing Solutions, LLC
Рет қаралды 443 М.
How To Vent & Plumb a Toilet (in 2024)
6:59
Hammerpedia
Рет қаралды 2,4 МЛН
how to do rough in plumbing for a bathroom & kitchen in a basement?
36:39
Renovation school
Рет қаралды 160 М.
Plumbing Rough In (Venting) The Building Expert 2021
6:41
The Building Expert
Рет қаралды 45 М.