Produced and Consumed Tags in Studio 5000

  Рет қаралды 6,916

Tim Wilborne

Tim Wilborne

Жыл бұрын

You can use produced and consumed tags to communicate seamlessly between Controllogix/Compactlogix PLCs.
The produced tag in one PLC will be the consumed tag in the other PLC.
Helping you become a better technician so you will always be in demand
Get the full details of this lesson at courses.twcontrols.com/
Items used in this video:
PLC Trainer twcontrols.com/plc-trainers
The above links make these videos possible. Please use them!
Support these videos while you advance your skills courses.twcontrols.com/

Пікірлер: 9
@OldePhart
@OldePhart Жыл бұрын
Since its rare to P/C a single tag and instead to use an array or a UDT, I create these I use the naming format PLCNAME1toPLCNAME2 for the tag array at both ends. That way just from the name you know the source and destination of that tag group.
@TimWilborne
@TimWilborne Жыл бұрын
Good tip
@bsmith221
@bsmith221 Жыл бұрын
Tim, great video. I have a quick question. Is this basically the same thing as using a MSG instruction? In what situation would you want to use one or the other if so? Thanks.
@leviholloway
@leviholloway Жыл бұрын
Good question, I was wondering the same thing.
@TimWilborne
@TimWilborne Жыл бұрын
Not exactly the same thing, Produced and Consumed tags a deterministic which basically means they are the same as I/O being connected "directly" to the PLC. Messaging instructions are more of lobbing notes across a wall. Great question Billy!
@willysadventurechannel2964
@willysadventurechannel2964 Жыл бұрын
When your wanting to communicate with other PLCs or multiple at same time in a plant
@jackpast
@jackpast Жыл бұрын
Produced and consumed example is a p/e is easier and closer to wire to an i/o card from one plc but it is controlling a conveyor controlled by another plc. Sound right, Tim?
@atis567
@atis567 3 ай бұрын
Is it possible to create produce consume to plc in online
@TimWilborne
@TimWilborne 3 ай бұрын
No, offline only. If you can't interrupt the process, you could use the MSG instruction.
Studio 5000 CTU CTD Counter Explained
15:21
Tim Wilborne
Рет қаралды 18 М.
Sinking and Sourcing PLC Inputs with PNP NPN Sensors
17:31
Tim Wilborne
Рет қаралды 154 М.
Became invisible for one day!  #funny #wednesday #memes
00:25
Watch Me
Рет қаралды 59 МЛН
HOW DID HE WIN? 😱
00:33
Topper Guild
Рет қаралды 49 МЛН
Самый Молодой Актёр Без Оскара 😂
00:13
Глеб Рандалайнен
Рет қаралды 4,3 МЛН
Studio 5000 & RsLogix 5000 Produced and Consumed Tags
20:50
Tim Wilborne
Рет қаралды 25 М.
Studio 5000 Data Types.  BOOL, INT, DINT, and REAL?
12:56
Tim Wilborne
Рет қаралды 19 М.
Communication between Compactlogix and Micrologix 1400 via MSG instruction
8:51
Indirect Addressing in Studio 5000 to Store and Retrieve Data
20:02
PLCGurus.NET - How To Create Tags In Studio 5000
12:39
PLCGurus.NET
Рет қаралды 33 М.
Studio 5000 AFI Always False Input vs JMP LBL to Disable Rung
8:33
Tim Wilborne
Рет қаралды 3,6 М.
4-20mA Current Signal? Wiring, Scaling, Programming, Troubleshooting
3:08:30
Top 50 Amazon Prime Day 2024 Deals 🤑 (Updated Hourly!!)
12:37
The Deal Guy
Рет қаралды 1,4 МЛН
Это - iPhone 16 и вот что надо знать...
17:20
Overtake lab
Рет қаралды 91 М.
EXEED VX 2024: Не өзгерді?
9:06
Oljas Oqas
Рет қаралды 45 М.