PROVISION REFRIGERATION TROUBLESHOOTING | Marine Electrician

  Рет қаралды 112,324

leckyjake

leckyjake

3 жыл бұрын

Here is the troubleshooting I did in our provision refrigeration system #ETO #marineelectrician #leckyjake #refrigeration #evaporator #seaman #seafarer

Пікірлер: 234
@johncantrell614
@johncantrell614 2 жыл бұрын
Thanks for sharing this refrigeration information, along with your electrical information as well! 🙂
@CruisingMaya
@CruisingMaya 2 жыл бұрын
Informative and on point- thanks for putting this together!
@PracticalMECEngineStudy
@PracticalMECEngineStudy 2 жыл бұрын
Very Nicely explained. I am excited to see your next video on Provision refrigeration troubles. Thanks
@farhanfaisol6498
@farhanfaisol6498 2 жыл бұрын
Thanks leaky Jake hope can hear more knowledge from you
@ethanlove5513
@ethanlove5513 Жыл бұрын
As always excellent and informative video keep them coming. This is a common problem I’ve encountered this many times but the Chief just had me use hot water to break up the ice 🧊
@vietvu8659
@vietvu8659 2 ай бұрын
Very good video and explained. I am excited to see your next video on Provision refrigeration troubles. Thanks
@arielcuaresma7878
@arielcuaresma7878 Жыл бұрын
Godbless po!,please keep posting such knowledge and ideas👍👍👍
@manubkrishnan
@manubkrishnan 5 ай бұрын
Thank you Jake... expecting more videos related to refrigeration and air condition....Thank you...😊
@jaykesapalaran5434
@jaykesapalaran5434 Жыл бұрын
Sir salamat Po sa mga idea ng mga troubleshooting.. ❤️Keep safe all
@16valve64
@16valve64 2 жыл бұрын
Thanks a lot for sharing your thoughts
@__iam.zee_
@__iam.zee_ 3 жыл бұрын
Your videos are the most simplified and well explained. Keep posting such. It has been a great practical knowledge booster for many of the youngsters like us😊👍🏻
@leckyjake
@leckyjake 3 жыл бұрын
Thank you very much. Next video is the modification of wiring diagram
@engrlavalava8232
@engrlavalava8232 3 жыл бұрын
Thank you for the knowledge. Keep it up!
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for your support
@muhammadansar_2084
@muhammadansar_2084 5 ай бұрын
Good share from kabayan base on his experience faced on board ship recently as it also can advance to someone else knowledge about fridge system...😊
@ronkurey8840
@ronkurey8840 2 жыл бұрын
Excellent!
@25denzil
@25denzil 2 жыл бұрын
Your video cover much more than what institutes teach us. Awesome video 👌🏻
@findvoltage
@findvoltage 2 жыл бұрын
its up to you to research,. they teach you what you need to know the rest is up to you. your going to have to learn how to learn. you will have to start thinking for your self now, no one can teach you everything, no one!
@TJ-bi8hf
@TJ-bi8hf 2 жыл бұрын
very informative Elec. thank you
@abhijithmohan6035
@abhijithmohan6035 3 жыл бұрын
thank you for making very informative video -as you mentioned at the end waiting video regarding other problems facing on refrigeration ,keep doing very good work lecky
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for the support
@syedbasheer8210
@syedbasheer8210 3 жыл бұрын
Great job✅
@arielsaemon6170
@arielsaemon6170 3 жыл бұрын
Thanks for your video sir. It's very helpfull 🙏.
@frankcloskey7789
@frankcloskey7789 Жыл бұрын
This is the best Refrigeration field for a job. Excellent trouble shooting. 9/30/2022yr
@hiteshraibagkar7766
@hiteshraibagkar7766 2 жыл бұрын
Very Nice . Thank you.
@jeomarhidalgo8300
@jeomarhidalgo8300 3 жыл бұрын
Thank you sir lecky for another knowledgeable ideas.
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for your good comments
@geremeicaro1637
@geremeicaro1637 Жыл бұрын
Very informative sir thank you for sharing your expertise ingat lagi SA paglalayag God bless
@zanegraydulnuan3754
@zanegraydulnuan3754 2 жыл бұрын
Nice very informative video. Just piece of advice much better and safer to use water in defrosting expansion valve.
@geonbuenvenida5445
@geonbuenvenida5445 2 жыл бұрын
Thankyou sir very informative .. seaferer din ako passenger vessel mag isa lang din po ako na reefer dito ... upload ka din sir sa trouble ng chiller compressor
@fredsalter1915
@fredsalter1915 2 жыл бұрын
What a cool job! Sailing the beautiful seas and keeping the vessel's systems in ship-shape!
@pjero2005
@pjero2005 2 жыл бұрын
Only a guy that has never worked on sea can say that (marine engineer with 14 years expirience)
@fredsalter1915
@fredsalter1915 2 жыл бұрын
@@pjero2005 Maybe true, but I still think Lecky Jake has an enviable job!
@NataneAlves5
@NataneAlves5 3 жыл бұрын
Thanks for the video!!!
@rupanjansaha4788
@rupanjansaha4788 9 ай бұрын
Excellent,,
@marinonglubas6103
@marinonglubas6103 3 жыл бұрын
Napaka systematic mo talaga sir pag apporach sa problem. Thumbs up!
@leckyjake
@leckyjake 3 жыл бұрын
Thank you and sana meron ka din sayo na yung convinient ka sa ginagawa mo. Safe sailing
@syarifudin_bwx3904
@syarifudin_bwx3904 Жыл бұрын
Nice bro, thank u for the knowledge
@sohaghossain6469
@sohaghossain6469 Жыл бұрын
Thank you so much for your information
@emmanuelzamora1114
@emmanuelzamora1114 2 жыл бұрын
Good job sir jake kaya pala nag ice build up yung evaporator ng chiller dahil d wastong pagset yung TXV..lage po ako nanonood sa vlog nyu sir.sana palarin gaya nyu po.
@bersajibuden1681
@bersajibuden1681 3 жыл бұрын
Thank you so much sir, stay safe always!!!!
@leckyjake
@leckyjake 3 жыл бұрын
Thank you
@ccoairconservicescris1605
@ccoairconservicescris1605 Жыл бұрын
Keep posting sir tnx
@jeynishjayaraj9416
@jeynishjayaraj9416 3 жыл бұрын
I am studying for eto now... Urs video r very useful to me.. Thank u
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for watching
@gurbirsingh8232
@gurbirsingh8232 10 ай бұрын
Nice video sir thanks
@joselitomacapaz8521
@joselitomacapaz8521 2 жыл бұрын
thank to your sharing kabayan God keep bless you
@joseantoniolobera2795
@joseantoniolobera2795 2 жыл бұрын
A Lot of tHanks for the vídeo
@aiahamadumbayo7475
@aiahamadumbayo7475 Жыл бұрын
Thanks very much.
@vijayakrishnankogulan7738
@vijayakrishnankogulan7738 2 жыл бұрын
Super thank you sir
@thivankagamage2630
@thivankagamage2630 Жыл бұрын
Hi,, thanks for the vedio which is very usefull.. Lecky,, I have a same trouble which is Ice deposit on expansion valve. I have cleaned inside filter and run the system. But trouble is remaining still. Unfortunately , I dont have a spare one onboard ...😒
@joeybocabel7897
@joeybocabel7897 3 жыл бұрын
Nice video lecky 👍🏻
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for the support
@marinemaza245
@marinemaza245 2 жыл бұрын
Very good vedio ..after watching yr vedio thing came in my mind Is let me first subscribe then go for next😂
@rajeshloganathan6910
@rajeshloganathan6910 3 жыл бұрын
Sir please keep on update more knowledge eto videos
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for the support
@temoteoalmendras3600
@temoteoalmendras3600 2 жыл бұрын
Salamat lecky
@martvofficialchannel4208
@martvofficialchannel4208 Жыл бұрын
Salamat sa idea master
@reyencels1749
@reyencels1749 2 жыл бұрын
Slmat sir lecky jake
@frankcloskey7789
@frankcloskey7789 2 жыл бұрын
Excellent Trouble shooting a superheat adjust ment needed. 10/30 2021
@chinesenightbreaker02fl.h79
@chinesenightbreaker02fl.h79 2 ай бұрын
Salamat Po!Keep in mind my friend that as ship's ETO to deal with refrigerators and A/C IS NOT YOUR OBLIGATION OR JOB!!!Where is your engineers?Scratching the ases in ECR perhaps?Let them do their job where a refrigeration systems is one of their duties!
@dmitriibugayov6975
@dmitriibugayov6975 2 ай бұрын
It depends on the situation on board. Sometimes you have engineers who are so helpless... Better to do it by yourself to be sure that job is done and nobody gives you extra problems when doing some shit there. Sometimes you knowleges much better than your team in this area, and if people on board are good- better to help them) But if there are lazy stupid motherfuckers- of course send them to do their job))😅
@jimmyestomata517
@jimmyestomata517 2 жыл бұрын
Thank you sir
@coldstorage3616
@coldstorage3616 3 жыл бұрын
Thank You po Sir Leckyjake👍🙏☺️
@leckyjake
@leckyjake 3 жыл бұрын
👍👍👍
@ebfsystem
@ebfsystem 7 ай бұрын
I'll love to be side by side with you while you do the troubleshooting,,, I'll be asking 2 million questions 😂😂
@chrishye
@chrishye 11 ай бұрын
Our Blaster Freezer room (-40C) frequently have icing on the floor (we have proper door with gasket and curtain strips but hot air from outside or products when we push the hot product into the room to freeze them). Our floor has changed to use PU to reduce icing and anti-slip yet still have this issue... do you have any suggestions?
@ashimkumaradhikari4902
@ashimkumaradhikari4902 2 жыл бұрын
Thank you. What will be the problem if i get ice only on expansion valve but not on Evaporator.
@monzurhasan3583
@monzurhasan3583 3 жыл бұрын
After wait is end 🥰🥰🥰
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for your support
@user-ek8tl5ok3r
@user-ek8tl5ok3r 4 ай бұрын
Sir good job Sana mag labas ka din ng video kung paano ang adjustment ng txv sa ice machine tnx sir
@pauljohnson811
@pauljohnson811 2 жыл бұрын
Thankyou sir...very helpful ❤️
@leckyjake
@leckyjake 2 жыл бұрын
Thanks for the support
@naylinhan5795
@naylinhan5795 2 жыл бұрын
how about back pressure control valve on the evaporator out let? does it function correctly? need adjustment. i guess.
@chuengzhao6143
@chuengzhao6143 3 жыл бұрын
👌🏾👌🏾❤️
@amaldcrewz1122
@amaldcrewz1122 2 жыл бұрын
👏👏
@jaykesapalaran5434
@jaykesapalaran5434 Жыл бұрын
Sir sana next video Po charging of refrigerant..at ano procedure safety ways
@yongtamz1194
@yongtamz1194 2 жыл бұрын
Thanks for this video sir more power to you,anyway sir where you can bought your tool permanent magnet it is so nice?
@jhonpaulnatividad6120
@jhonpaulnatividad6120 Жыл бұрын
nice galing
@imranshaheen8139
@imranshaheen8139 3 жыл бұрын
Tnx for sharing,,,,
@leckyjake
@leckyjake 3 жыл бұрын
Thanks for watching
@sumeshlalsurendran2193
@sumeshlalsurendran2193 Жыл бұрын
Dear Jake, Icing on evaporator ,so you reduced the super heat by turning it into counter clock wise. Actually here, superheat was "increased". I believe it's done after turning the adjustment screw to "clock wise ."
@bt9604
@bt9604 Жыл бұрын
Are u eto
@NisanthVpillaiIndia
@NisanthVpillaiIndia 6 ай бұрын
Superheat is reduced by turning anticlockwise.
@nestormolato1158
@nestormolato1158 5 ай бұрын
Hi Elect, thank you for the video, just curious if the vegetable room have evaporator pressure regulator since the piping is interconnected with meat and fish freezer? Means both suction pressure are the same. Provision compressors on this video is Bitzer / Sabroe open type.
@vincemontajes
@vincemontajes 7 ай бұрын
👍
@ayhamshbat2733
@ayhamshbat2733 2 жыл бұрын
Hi thx u for the content , I got confused when u lower the super heat the ice will be melted? Isn't increasing the heat will melt the ice
@kamaltandel1458
@kamaltandel1458 Жыл бұрын
How we know we increased or decreased superheat by turning the screw.is there any marking for clock wise and anticlock wise for increased or decreased the superheat
@deepaksikarwar4129
@deepaksikarwar4129 3 жыл бұрын
Sir you are my favorite one ❤️ Lots of love 💕 Keep making knowledgeable videos and share your experience 🙏🏻
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for your wonderful comment. This is what I need to keep me going
@deepaksikarwar4129
@deepaksikarwar4129 3 жыл бұрын
Happy to see your reply i will always support you ❤️
@hasanulhudybi8054
@hasanulhudybi8054 2 жыл бұрын
@@leckyjake plz give ur mail address
@winefredcaluser5014
@winefredcaluser5014 2 жыл бұрын
Hi! Lecky Jake good day to you. Elect I have a question maybe you can help me. My question is, what is the common caused or the problem of the Cylinder head and the line in Marine Refrigeration Icing?
@marklaman1498
@marklaman1498 3 жыл бұрын
Nakasubscribe na bro...
@leckyjake
@leckyjake 3 жыл бұрын
Thanks
@MrAviraabraham
@MrAviraabraham 2 жыл бұрын
Nice videos, which ships are you sailing on ?
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
Very good job 👍
@ShahbazAlam-tr6cn
@ShahbazAlam-tr6cn 3 жыл бұрын
After long time sir
@leckyjake
@leckyjake 3 жыл бұрын
Just arrived in the port today
@mrvoyageratseaandland8100
@mrvoyageratseaandland8100 2 жыл бұрын
Good one sir. Sir how did u adjusting the manual txv value did there is any specific adjustment value is there ah sir
@lecmen47
@lecmen47 2 жыл бұрын
by freezing, possibility, thermostat, coolant, or some leak in ducts etc.
@reygenoguin8110
@reygenoguin8110 2 жыл бұрын
Sir good day , what pressure of refregirant for low and high pressure can you say that your refrigerant is enough ??thankyou
@edmaresguerra5897
@edmaresguerra5897 2 жыл бұрын
Defrosting procedure using water is not an excellent way of doing it. This is the old way done by old marine engineer but you have done a good job.
@arunamanawaduge1574
@arunamanawaduge1574 3 жыл бұрын
Sir please make one Vidio about how to test generator alarm for the serveay require
@satyabratgaan4918
@satyabratgaan4918 5 ай бұрын
Kindly it would be nice to elaborate on superheat thing. First of all if the system was running fine before this problem happened and there was no work done on the TXV of veg room . So why to solve the problem we have to open the TXV more . As we know it has been set by factory before it was fitted as per requirement of the system. That clearly says that TXV should automatically open more as per the operational requirement. That means opening pressure due to the bulb sensing is not sufficient to maintain the superheat. Though the action solved the problem but I feel if TXV is malfunctioning then it needs to be changed so that it maintains the temperature in the previous setting of the TXV.
@mtwithismail9801
@mtwithismail9801 Ай бұрын
😊
@liam3284
@liam3284 Ай бұрын
Risk to open too much is flooding back and damaging the compressor. However, at sea those TXV are subject to a lot more mechanical disturbance than on land.
@keepthinking2666
@keepthinking2666 Жыл бұрын
Okay I love you videos but you do know you should mention to people if you take off a solenoid coil when it's energized that you going to end up burning up the coil
@ruffalearapal1126
@ruffalearapal1126 2 жыл бұрын
Sir where can you buy that magnetic solinoid tester?
@jeffreycidro943
@jeffreycidro943 2 жыл бұрын
wher which turn direction in that case sir...the ice build up problem,,,1 full turn left or right?
@OFFSHORE-ETO
@OFFSHORE-ETO Жыл бұрын
⭐⭐⭐
@antonyzairaz7627
@antonyzairaz7627 11 ай бұрын
Could you please explain the fish room tem. Not coming more then -15 dig set tem. Is -18 dig. Meat room mainten 18dig.
@varungupta1073
@varungupta1073 2 жыл бұрын
I can see there is always lot of ice formation on the door sometime it is very impossible to open what could be the reason pls reply
@kennethlobo4420
@kennethlobo4420 3 жыл бұрын
I liked the video.,yes there is a great responsibility to keep the system going,out at sea.Water is the superheat U maintain on this cooler? In future show us the superheat setting
@kitioneturaganivalu5038
@kitioneturaganivalu5038 3 жыл бұрын
trial and error
@kennethlobo4420
@kennethlobo4420 3 жыл бұрын
Okay
@ekojuniharyanto655
@ekojuniharyanto655 6 ай бұрын
Normaly expantion valve how many turn Jack , ❤❤❤
@kuttu45454
@kuttu45454 2 жыл бұрын
Is there any filter near the exp valve
@user-oi7xx6gr3b
@user-oi7xx6gr3b 3 жыл бұрын
Wait for this video
@leckyjake
@leckyjake 3 жыл бұрын
Thank you for your support
@user-oi7xx6gr3b
@user-oi7xx6gr3b 3 жыл бұрын
@@leckyjake thanh You for this perfect video!!! Really!
@mehmetguver9322
@mehmetguver9322 2 жыл бұрын
I talk about you new generation eto officers to watch your videos :)
@leckyjake
@leckyjake 2 жыл бұрын
Thank you very much for your wonderful comment. Very much appreciated
@danteybanez8495
@danteybanez8495 2 жыл бұрын
Hello leckay goo day! may tanong lang po ako sa reefer provision namin ang MEAT ROOM hindi mag auto start...pero mag auto stop naman? Pls. share your a good idea..
@imrankazi2759
@imrankazi2759 5 ай бұрын
Gmg sir saw ur vidio on no spare of txv.how to make. And troubleshooting for icing on evaporator.thanx Best regards Imran kazi 2nd engineer Teekay tanker ship mgmt.
@kergamingtv1857
@kergamingtv1857 Жыл бұрын
what is cause of the freezing expansion valve?
@ShubhamSingh-bn3vx
@ShubhamSingh-bn3vx 3 жыл бұрын
I m on board as a trainee, keep waits ur video on board too
@leckyjake
@leckyjake 3 жыл бұрын
Videos will be uploaded every weekend.
@saidabdulle4592
@saidabdulle4592 Жыл бұрын
If thermoking sb210 does can I do same thing and it my help
@AminulIslam-hq7ot
@AminulIslam-hq7ot Жыл бұрын
in bitzer semi hermetic compressore,when we start it then temperature down -25°C.after then temperature reached -7°C and after again not reached to -25°C.so what can i do to solve this problem??
@tomoliver8498
@tomoliver8498 2 жыл бұрын
It simply needed an off cycle defrost timer installed or replaced. Or may have been trying to run it too cold. I doubt the txv needed adjusting.
@leckyjake
@leckyjake 2 жыл бұрын
It is actually a vegetable room so no defrost for the system
@persimonsen8792
@persimonsen8792 2 жыл бұрын
@@leckyjake How do you keep 4C in there without defrost ? In a humid enviroment in a kitchen and especially on a ship at sea.
@gealje9433
@gealje9433 3 жыл бұрын
Thank you for this video. I still have a question, how do you know the level of the refrigerent is okay? And how do you assess the evaporators on your meat and fish room are still good?
@leckyjake
@leckyjake 3 жыл бұрын
For the level, check your pressures, and on the sight glass you will see the level. For the evap of meat room and fish room, no ice to thaw on the grill and the temperature is in range.
@SCAMATICS777
@SCAMATICS777 2 жыл бұрын
So is the same compressor running all 3 rooms? I was curious on refrigerant level as well but did not see any gauge readings. Nice video. I would like to see a little more testing before your determination. Thank you. Im about to get certified but lack experience because of covid schooling turned to online.
@findvoltage
@findvoltage 2 жыл бұрын
@@SCAMATICS777 Its the same as a multi split system AC. no difference, dont confuse yourself with labels, look at what they are, just a pump cycle with switches and relays, oh and mini switches and relays (PCB's). easy as pie, a trained money could do this work. im living proof.
@findvoltage
@findvoltage 2 жыл бұрын
Super heat and subcooling is hoew to tune a system, go look it up. you will need to know what they mean if your going for a jab,... i mean job.
@ivanfmartinezm
@ivanfmartinezm Жыл бұрын
You can see the refrigerant level on the sightglass paced on the condenser unit wich should be at middle the liquid level. Furthermore the temperature from fish and meat room are both in range -18 °C, also you can see the refrigerante gauge from low pressure the indication should be about 1 bar or higher with one of the chamber are working, i hope this make sense and can help you.
TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?
10:29
leckyjake
Рет қаралды 175 М.
How To Troubleshoot a Walk In Freezer Running Warm
10:57
Rookie Refrigeration
Рет қаралды 74 М.
WHO DO I LOVE MOST?
00:22
dednahype
Рет қаралды 78 МЛН
Luck Decides My Future Again 🍀🍀🍀 #katebrush #shorts
00:19
Kate Brush
Рет қаралды 8 МЛН
Vivaan  Tanya once again pranked Papa 🤣😇🤣
00:10
seema lamba
Рет қаралды 28 МЛН
Burnt VFD, Why?????
8:45
leckyjake
Рет қаралды 21 М.
ELEVATOR TROUBLESHOOTING | Marine Electrician
12:43
leckyjake
Рет қаралды 53 М.
DIY Cascade Refrigeration System (Part III)
13:12
Hyperspace Pirate
Рет қаралды 101 М.
How to Check Evaporator Superheat
4:11
HVAC Know It All
Рет қаралды 98 М.
Why Does The Evaporator Coil Freeze (And How to Diagnose It)
8:31
HVAC School
Рет қаралды 533 М.
WHO DO I LOVE MOST?
00:22
dednahype
Рет қаралды 78 МЛН