Here is the troubleshooting I did in our provision refrigeration system #ETO #marineelectrician #leckyjake #refrigeration #evaporator #seaman #seafarer
Пікірлер: 234
@johncantrell6142 жыл бұрын
Thanks for sharing this refrigeration information, along with your electrical information as well! 🙂
@CruisingMaya2 жыл бұрын
Informative and on point- thanks for putting this together!
@PracticalMECEngineStudy2 жыл бұрын
Very Nicely explained. I am excited to see your next video on Provision refrigeration troubles. Thanks
@farhanfaisol64982 жыл бұрын
Thanks leaky Jake hope can hear more knowledge from you
@ethanlove5513 Жыл бұрын
As always excellent and informative video keep them coming. This is a common problem I’ve encountered this many times but the Chief just had me use hot water to break up the ice 🧊
@vietvu86592 ай бұрын
Very good video and explained. I am excited to see your next video on Provision refrigeration troubles. Thanks
@arielcuaresma7878 Жыл бұрын
Godbless po!,please keep posting such knowledge and ideas👍👍👍
@manubkrishnan5 ай бұрын
Thank you Jake... expecting more videos related to refrigeration and air condition....Thank you...😊
@jaykesapalaran5434 Жыл бұрын
Sir salamat Po sa mga idea ng mga troubleshooting.. ❤️Keep safe all
@16valve642 жыл бұрын
Thanks a lot for sharing your thoughts
@__iam.zee_3 жыл бұрын
Your videos are the most simplified and well explained. Keep posting such. It has been a great practical knowledge booster for many of the youngsters like us😊👍🏻
@leckyjake3 жыл бұрын
Thank you very much. Next video is the modification of wiring diagram
@engrlavalava82323 жыл бұрын
Thank you for the knowledge. Keep it up!
@leckyjake3 жыл бұрын
Thank you for your support
@muhammadansar_20845 ай бұрын
Good share from kabayan base on his experience faced on board ship recently as it also can advance to someone else knowledge about fridge system...😊
@ronkurey88402 жыл бұрын
Excellent!
@25denzil2 жыл бұрын
Your video cover much more than what institutes teach us. Awesome video 👌🏻
@findvoltage2 жыл бұрын
its up to you to research,. they teach you what you need to know the rest is up to you. your going to have to learn how to learn. you will have to start thinking for your self now, no one can teach you everything, no one!
@TJ-bi8hf2 жыл бұрын
very informative Elec. thank you
@abhijithmohan60353 жыл бұрын
thank you for making very informative video -as you mentioned at the end waiting video regarding other problems facing on refrigeration ,keep doing very good work lecky
@leckyjake3 жыл бұрын
Thank you for the support
@syedbasheer82103 жыл бұрын
Great job✅
@arielsaemon61703 жыл бұрын
Thanks for your video sir. It's very helpfull 🙏.
@frankcloskey7789 Жыл бұрын
This is the best Refrigeration field for a job. Excellent trouble shooting. 9/30/2022yr
@hiteshraibagkar77662 жыл бұрын
Very Nice . Thank you.
@jeomarhidalgo83003 жыл бұрын
Thank you sir lecky for another knowledgeable ideas.
@leckyjake3 жыл бұрын
Thank you for your good comments
@geremeicaro1637 Жыл бұрын
Very informative sir thank you for sharing your expertise ingat lagi SA paglalayag God bless
@zanegraydulnuan37542 жыл бұрын
Nice very informative video. Just piece of advice much better and safer to use water in defrosting expansion valve.
@geonbuenvenida54452 жыл бұрын
Thankyou sir very informative .. seaferer din ako passenger vessel mag isa lang din po ako na reefer dito ... upload ka din sir sa trouble ng chiller compressor
@fredsalter19152 жыл бұрын
What a cool job! Sailing the beautiful seas and keeping the vessel's systems in ship-shape!
@pjero20052 жыл бұрын
Only a guy that has never worked on sea can say that (marine engineer with 14 years expirience)
@fredsalter19152 жыл бұрын
@@pjero2005 Maybe true, but I still think Lecky Jake has an enviable job!
@NataneAlves53 жыл бұрын
Thanks for the video!!!
@rupanjansaha47889 ай бұрын
Excellent,,
@marinonglubas61033 жыл бұрын
Napaka systematic mo talaga sir pag apporach sa problem. Thumbs up!
@leckyjake3 жыл бұрын
Thank you and sana meron ka din sayo na yung convinient ka sa ginagawa mo. Safe sailing
@syarifudin_bwx3904 Жыл бұрын
Nice bro, thank u for the knowledge
@sohaghossain6469 Жыл бұрын
Thank you so much for your information
@emmanuelzamora11142 жыл бұрын
Good job sir jake kaya pala nag ice build up yung evaporator ng chiller dahil d wastong pagset yung TXV..lage po ako nanonood sa vlog nyu sir.sana palarin gaya nyu po.
@bersajibuden16813 жыл бұрын
Thank you so much sir, stay safe always!!!!
@leckyjake3 жыл бұрын
Thank you
@ccoairconservicescris1605 Жыл бұрын
Keep posting sir tnx
@jeynishjayaraj94163 жыл бұрын
I am studying for eto now... Urs video r very useful to me.. Thank u
@leckyjake3 жыл бұрын
Thank you for watching
@gurbirsingh823210 ай бұрын
Nice video sir thanks
@joselitomacapaz85212 жыл бұрын
thank to your sharing kabayan God keep bless you
@joseantoniolobera27952 жыл бұрын
A Lot of tHanks for the vídeo
@aiahamadumbayo7475 Жыл бұрын
Thanks very much.
@vijayakrishnankogulan77382 жыл бұрын
Super thank you sir
@thivankagamage2630 Жыл бұрын
Hi,, thanks for the vedio which is very usefull.. Lecky,, I have a same trouble which is Ice deposit on expansion valve. I have cleaned inside filter and run the system. But trouble is remaining still. Unfortunately , I dont have a spare one onboard ...😒
@joeybocabel78973 жыл бұрын
Nice video lecky 👍🏻
@leckyjake3 жыл бұрын
Thank you for the support
@marinemaza2452 жыл бұрын
Very good vedio ..after watching yr vedio thing came in my mind Is let me first subscribe then go for next😂
@rajeshloganathan69103 жыл бұрын
Sir please keep on update more knowledge eto videos
@leckyjake3 жыл бұрын
Thank you for the support
@temoteoalmendras36002 жыл бұрын
Salamat lecky
@martvofficialchannel4208 Жыл бұрын
Salamat sa idea master
@reyencels17492 жыл бұрын
Slmat sir lecky jake
@frankcloskey77892 жыл бұрын
Excellent Trouble shooting a superheat adjust ment needed. 10/30 2021
@chinesenightbreaker02fl.h792 ай бұрын
Salamat Po!Keep in mind my friend that as ship's ETO to deal with refrigerators and A/C IS NOT YOUR OBLIGATION OR JOB!!!Where is your engineers?Scratching the ases in ECR perhaps?Let them do their job where a refrigeration systems is one of their duties!
@dmitriibugayov69752 ай бұрын
It depends on the situation on board. Sometimes you have engineers who are so helpless... Better to do it by yourself to be sure that job is done and nobody gives you extra problems when doing some shit there. Sometimes you knowleges much better than your team in this area, and if people on board are good- better to help them) But if there are lazy stupid motherfuckers- of course send them to do their job))😅
@jimmyestomata5172 жыл бұрын
Thank you sir
@coldstorage36163 жыл бұрын
Thank You po Sir Leckyjake👍🙏☺️
@leckyjake3 жыл бұрын
👍👍👍
@ebfsystem7 ай бұрын
I'll love to be side by side with you while you do the troubleshooting,,, I'll be asking 2 million questions 😂😂
@chrishye11 ай бұрын
Our Blaster Freezer room (-40C) frequently have icing on the floor (we have proper door with gasket and curtain strips but hot air from outside or products when we push the hot product into the room to freeze them). Our floor has changed to use PU to reduce icing and anti-slip yet still have this issue... do you have any suggestions?
@ashimkumaradhikari49022 жыл бұрын
Thank you. What will be the problem if i get ice only on expansion valve but not on Evaporator.
@monzurhasan35833 жыл бұрын
After wait is end 🥰🥰🥰
@leckyjake3 жыл бұрын
Thank you for your support
@user-ek8tl5ok3r4 ай бұрын
Sir good job Sana mag labas ka din ng video kung paano ang adjustment ng txv sa ice machine tnx sir
@pauljohnson8112 жыл бұрын
Thankyou sir...very helpful ❤️
@leckyjake2 жыл бұрын
Thanks for the support
@naylinhan57952 жыл бұрын
how about back pressure control valve on the evaporator out let? does it function correctly? need adjustment. i guess.
@chuengzhao61433 жыл бұрын
👌🏾👌🏾❤️
@amaldcrewz11222 жыл бұрын
👏👏
@jaykesapalaran5434 Жыл бұрын
Sir sana next video Po charging of refrigerant..at ano procedure safety ways
@yongtamz11942 жыл бұрын
Thanks for this video sir more power to you,anyway sir where you can bought your tool permanent magnet it is so nice?
@jhonpaulnatividad6120 Жыл бұрын
nice galing
@imranshaheen81393 жыл бұрын
Tnx for sharing,,,,
@leckyjake3 жыл бұрын
Thanks for watching
@sumeshlalsurendran2193 Жыл бұрын
Dear Jake, Icing on evaporator ,so you reduced the super heat by turning it into counter clock wise. Actually here, superheat was "increased". I believe it's done after turning the adjustment screw to "clock wise ."
@bt9604 Жыл бұрын
Are u eto
@NisanthVpillaiIndia6 ай бұрын
Superheat is reduced by turning anticlockwise.
@nestormolato11585 ай бұрын
Hi Elect, thank you for the video, just curious if the vegetable room have evaporator pressure regulator since the piping is interconnected with meat and fish freezer? Means both suction pressure are the same. Provision compressors on this video is Bitzer / Sabroe open type.
@vincemontajes7 ай бұрын
👍
@ayhamshbat27332 жыл бұрын
Hi thx u for the content , I got confused when u lower the super heat the ice will be melted? Isn't increasing the heat will melt the ice
@kamaltandel1458 Жыл бұрын
How we know we increased or decreased superheat by turning the screw.is there any marking for clock wise and anticlock wise for increased or decreased the superheat
@deepaksikarwar41293 жыл бұрын
Sir you are my favorite one ❤️ Lots of love 💕 Keep making knowledgeable videos and share your experience 🙏🏻
@leckyjake3 жыл бұрын
Thank you for your wonderful comment. This is what I need to keep me going
@deepaksikarwar41293 жыл бұрын
Happy to see your reply i will always support you ❤️
@hasanulhudybi80542 жыл бұрын
@@leckyjake plz give ur mail address
@winefredcaluser50142 жыл бұрын
Hi! Lecky Jake good day to you. Elect I have a question maybe you can help me. My question is, what is the common caused or the problem of the Cylinder head and the line in Marine Refrigeration Icing?
@marklaman14983 жыл бұрын
Nakasubscribe na bro...
@leckyjake3 жыл бұрын
Thanks
@MrAviraabraham2 жыл бұрын
Nice videos, which ships are you sailing on ?
@wasimedoo7994 Жыл бұрын
Very good job 👍
@ShahbazAlam-tr6cn3 жыл бұрын
After long time sir
@leckyjake3 жыл бұрын
Just arrived in the port today
@mrvoyageratseaandland81002 жыл бұрын
Good one sir. Sir how did u adjusting the manual txv value did there is any specific adjustment value is there ah sir
@lecmen472 жыл бұрын
by freezing, possibility, thermostat, coolant, or some leak in ducts etc.
@reygenoguin81102 жыл бұрын
Sir good day , what pressure of refregirant for low and high pressure can you say that your refrigerant is enough ??thankyou
@edmaresguerra58972 жыл бұрын
Defrosting procedure using water is not an excellent way of doing it. This is the old way done by old marine engineer but you have done a good job.
@arunamanawaduge15743 жыл бұрын
Sir please make one Vidio about how to test generator alarm for the serveay require
@satyabratgaan49185 ай бұрын
Kindly it would be nice to elaborate on superheat thing. First of all if the system was running fine before this problem happened and there was no work done on the TXV of veg room . So why to solve the problem we have to open the TXV more . As we know it has been set by factory before it was fitted as per requirement of the system. That clearly says that TXV should automatically open more as per the operational requirement. That means opening pressure due to the bulb sensing is not sufficient to maintain the superheat. Though the action solved the problem but I feel if TXV is malfunctioning then it needs to be changed so that it maintains the temperature in the previous setting of the TXV.
@mtwithismail9801Ай бұрын
😊
@liam3284Ай бұрын
Risk to open too much is flooding back and damaging the compressor. However, at sea those TXV are subject to a lot more mechanical disturbance than on land.
@keepthinking2666 Жыл бұрын
Okay I love you videos but you do know you should mention to people if you take off a solenoid coil when it's energized that you going to end up burning up the coil
@ruffalearapal11262 жыл бұрын
Sir where can you buy that magnetic solinoid tester?
@jeffreycidro9432 жыл бұрын
wher which turn direction in that case sir...the ice build up problem,,,1 full turn left or right?
@OFFSHORE-ETO Жыл бұрын
⭐⭐⭐
@antonyzairaz762711 ай бұрын
Could you please explain the fish room tem. Not coming more then -15 dig set tem. Is -18 dig. Meat room mainten 18dig.
@varungupta10732 жыл бұрын
I can see there is always lot of ice formation on the door sometime it is very impossible to open what could be the reason pls reply
@kennethlobo44203 жыл бұрын
I liked the video.,yes there is a great responsibility to keep the system going,out at sea.Water is the superheat U maintain on this cooler? In future show us the superheat setting
@kitioneturaganivalu50383 жыл бұрын
trial and error
@kennethlobo44203 жыл бұрын
Okay
@ekojuniharyanto6556 ай бұрын
Normaly expantion valve how many turn Jack , ❤❤❤
@kuttu454542 жыл бұрын
Is there any filter near the exp valve
@user-oi7xx6gr3b3 жыл бұрын
Wait for this video
@leckyjake3 жыл бұрын
Thank you for your support
@user-oi7xx6gr3b3 жыл бұрын
@@leckyjake thanh You for this perfect video!!! Really!
@mehmetguver93222 жыл бұрын
I talk about you new generation eto officers to watch your videos :)
@leckyjake2 жыл бұрын
Thank you very much for your wonderful comment. Very much appreciated
@danteybanez84952 жыл бұрын
Hello leckay goo day! may tanong lang po ako sa reefer provision namin ang MEAT ROOM hindi mag auto start...pero mag auto stop naman? Pls. share your a good idea..
@imrankazi27595 ай бұрын
Gmg sir saw ur vidio on no spare of txv.how to make. And troubleshooting for icing on evaporator.thanx Best regards Imran kazi 2nd engineer Teekay tanker ship mgmt.
@kergamingtv1857 Жыл бұрын
what is cause of the freezing expansion valve?
@ShubhamSingh-bn3vx3 жыл бұрын
I m on board as a trainee, keep waits ur video on board too
@leckyjake3 жыл бұрын
Videos will be uploaded every weekend.
@saidabdulle4592 Жыл бұрын
If thermoking sb210 does can I do same thing and it my help
@AminulIslam-hq7ot Жыл бұрын
in bitzer semi hermetic compressore,when we start it then temperature down -25°C.after then temperature reached -7°C and after again not reached to -25°C.so what can i do to solve this problem??
@tomoliver84982 жыл бұрын
It simply needed an off cycle defrost timer installed or replaced. Or may have been trying to run it too cold. I doubt the txv needed adjusting.
@leckyjake2 жыл бұрын
It is actually a vegetable room so no defrost for the system
@persimonsen87922 жыл бұрын
@@leckyjake How do you keep 4C in there without defrost ? In a humid enviroment in a kitchen and especially on a ship at sea.
@gealje94333 жыл бұрын
Thank you for this video. I still have a question, how do you know the level of the refrigerent is okay? And how do you assess the evaporators on your meat and fish room are still good?
@leckyjake3 жыл бұрын
For the level, check your pressures, and on the sight glass you will see the level. For the evap of meat room and fish room, no ice to thaw on the grill and the temperature is in range.
@SCAMATICS7772 жыл бұрын
So is the same compressor running all 3 rooms? I was curious on refrigerant level as well but did not see any gauge readings. Nice video. I would like to see a little more testing before your determination. Thank you. Im about to get certified but lack experience because of covid schooling turned to online.
@findvoltage2 жыл бұрын
@@SCAMATICS777 Its the same as a multi split system AC. no difference, dont confuse yourself with labels, look at what they are, just a pump cycle with switches and relays, oh and mini switches and relays (PCB's). easy as pie, a trained money could do this work. im living proof.
@findvoltage2 жыл бұрын
Super heat and subcooling is hoew to tune a system, go look it up. you will need to know what they mean if your going for a jab,... i mean job.
@ivanfmartinezm Жыл бұрын
You can see the refrigerant level on the sightglass paced on the condenser unit wich should be at middle the liquid level. Furthermore the temperature from fish and meat room are both in range -18 °C, also you can see the refrigerante gauge from low pressure the indication should be about 1 bar or higher with one of the chamber are working, i hope this make sense and can help you.