Refrigerant Pipe Sizing HVAC Basics

  Рет қаралды 25,059

Taddy Digest

Taddy Digest

2 жыл бұрын

How to size refrigerant piping?
Why is proper liquid and vapor line sizing so important?
Join this channel to get access to perks:
/ @taddydigest
If you want to learn more about HVAC check out my playlist hvac tips for technicians...
• How hvac technicians d...
Check out these other KZfaq Channels to stay up-to-date on the latest HVAC Knowledge
@HVACR VIDEOS
@HVAC School
@HVAC Know It All
@Nortek Global HVAC
If you want the same Tool Bag I have go check out www.orginalsoegear.com

Пікірлер: 63
@DanielPLarson-qt1ec
@DanielPLarson-qt1ec Жыл бұрын
Very Awesome, I have been following your instructions and guide lines. Very accurate, thank you for your professional guidance. Love your professional guidance!!!!
@rhpham2
@rhpham2 Жыл бұрын
Easier than I expected. Gracias
@TaddyDigest
@TaddyDigest Жыл бұрын
Great to hear!
@comandergamer3926
@comandergamer3926 Жыл бұрын
I'm going into pipefitting next month, this video is very helpful thank you!
@TaddyDigest
@TaddyDigest Жыл бұрын
Thank you man
@albardsahd8104
@albardsahd8104 Жыл бұрын
Thanks taddy for everything .great content keep it up
@TaddyDigest
@TaddyDigest Жыл бұрын
your welcome 🙏 🤗 glad you watched
@TheKadoxman
@TheKadoxman Жыл бұрын
Good stuff man
@carltucker5254
@carltucker5254 Жыл бұрын
Very informative thanks Tad!
@TaddyDigest
@TaddyDigest Жыл бұрын
Glad it was helpful!
@paulbryant68
@paulbryant68 11 ай бұрын
man u teach me some good stuff! im gettin better by the video! this just helped me figure a problem out. i was thinking why the the equipment come with 7/8 stub and somebody reduced to 3/4 on a 25’ line set so i started looking for legitimate answers. i never under mind the hvac engineers and thats just what this installer did to my customer! i sure its what they had on the truck and knew better. bottom line not dumb just lazy!
@TaddyDigest
@TaddyDigest 11 ай бұрын
Very cool brother thank you so much for watching
@KINGTIZZL3
@KINGTIZZL3 2 жыл бұрын
Just passed my epa test guys. Universal
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Awesome congrats my friend Now you're more successful than you've ever been Keep on keeping on
@KINGTIZZL3
@KINGTIZZL3 2 жыл бұрын
@@TaddyDigest thanks brother.
@fridayanthony2486
@fridayanthony2486 Жыл бұрын
What would be the result if I used 3 /8 to pipe 3 hours power
@oralreid7714
@oralreid7714 3 ай бұрын
Thank you but you've been very helpful
@oscarsoto8413
@oscarsoto8413 Жыл бұрын
This Video es perfect Boss
@jackbrennan8476
@jackbrennan8476 2 жыл бұрын
Good information
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thank You Jack I Appreciate you taking the time to watch 😀
@Ivaulo
@Ivaulo Жыл бұрын
Thanks!
@TaddyDigest
@TaddyDigest Жыл бұрын
Welcome!
@JessYalyson
@JessYalyson Жыл бұрын
Thanks a bunch Taddy! This was a grateful information man. Can you make a video about Piston Sizes Please?
@TaddyDigest
@TaddyDigest Жыл бұрын
Yes I can
@andrwvillan
@andrwvillan Жыл бұрын
But his humorous answer is that he wont
@raulsantinolopezrodriguez8349
@raulsantinolopezrodriguez8349 2 жыл бұрын
Gracias por compartir tus conocimientos y experiencias. Saludos cordiales desde Guadalajara México
@TaddyDigest
@TaddyDigest 2 жыл бұрын
You're welcome my friend thank you for watching
@tfortexas5098
@tfortexas5098 Жыл бұрын
What is the type of copper pipe is the coil pipe that you use for A/C?
@jacobdaugherty9564
@jacobdaugherty9564 Жыл бұрын
Hi there, I’m having a hard time determining if I need to size the lineset based on the condensing unit’s BTU’s or the Zone’s BTU’s. I have a Bosch 27k 3 zone mini split. Each zone is 9000btu respectively. Logic is telling me that I will only need a lineset big enough to cover 9000btu on each head. If I had a single zoned 27k btu head then obviously I would need a larger lineset. Am I incorrect? Thanks
@TaddyDigest
@TaddyDigest Жыл бұрын
you are correct
@DimitriBianco
@DimitriBianco Жыл бұрын
I'm installing a Gree 4 zone 9,9,12,18 mini split which has 2 branch boxes. The longest run is 40 feet. I'm concerned if I run 2 handlers off of one branch box that I would need to increase the line size to the box. Is it a valid concern or would the system be fine given the short line lengths?
@TaddyDigest
@TaddyDigest Жыл бұрын
Doesn't seem like a very long line set length I would not be concerned
@TaddyDigest
@TaddyDigest Жыл бұрын
Is always consult the installation instructions for the equipment though
@DimitriBianco
@DimitriBianco Жыл бұрын
@@TaddyDigest thanks! I just realized the package comes with larger lines to the boxes so no need for me to worry about determining the line sizes.
@ogulcanalpylmaz2145
@ogulcanalpylmaz2145 Жыл бұрын
Where can I find these catalogs and can I download them online?
@Amerikanin2numarali_ustasi
@Amerikanin2numarali_ustasi Жыл бұрын
www.crescentparts.com/wp-content/uploads/2019/11/DuPont-Suva-410A-Refrigerant-Piping-Guide.pdf
@nykid8849
@nykid8849 Жыл бұрын
very informative info, is it possible to change pipe size to get equal BTUS,example if u have larger BTU airhandler then the condensor , does increasing pipe size or decreasing pipe daimeter give u equal BTU to get proper cooling operation ?
@TaddyDigest
@TaddyDigest Жыл бұрын
I'm not sure if that's possible that's a good question though
@nykid8849
@nykid8849 Жыл бұрын
@@TaddyDigest I was at a job a while ago, that the airhandler was larger in BTU then the condensor, so they had to change suction pipe diameter to get same BTUS, it looked under engineered but did work.
@TaddyDigest
@TaddyDigest Жыл бұрын
It is common in the field to find pipe sizes that are too small for the newer equipment
@sivucit
@sivucit Жыл бұрын
Hi, quick question.. lets say you are replacing outdoor condensor unit, and if the existing vapor and liquid line length is not enough(assume0.. what kind of connector you use .. in plumbing we use 90 degree elbow etc.. i am not sure what will be used in HVAC just to extend the line by a feet or two. apprecaite your response
@TaddyDigest
@TaddyDigest Жыл бұрын
I would use a 90゚ elbow a 45゚ or a coupling.
@sivucit
@sivucit Жыл бұрын
@@TaddyDigest thanks does the 45 degree elbow sold in home depot works. Or hvac copper pipe and elbow are different type
@gregmun5595
@gregmun5595 Жыл бұрын
I bought a 3 ton condensing unit to replace old 3 ton unit. when I looked at the vaporside port for new one, it came with 7/8. So, the pipe in the house which is 3/4 wouldn't fit. Maybe I need an adapter.
@TaddyDigest
@TaddyDigest Жыл бұрын
are you sure it's a 3 ton 36k
@gregmun5595
@gregmun5595 Жыл бұрын
@@TaddyDigest I am positive. Because I ordered 3 ton unit. Maybe I need to go double check. It looked definitly bigger than old 3 unit.
@TaddyDigest
@TaddyDigest Жыл бұрын
yea, definitely double-check
@kevinpearce3281
@kevinpearce3281 Ай бұрын
You can buy a copper bushing that will adapt to 3/4
@jameylane1591
@jameylane1591 8 ай бұрын
Can you crush outside copper AC lines by standing on them?
@TaddyDigest
@TaddyDigest 8 ай бұрын
yes absolutely
@jameylane1591
@jameylane1591 8 ай бұрын
@@TaddyDigest What symptoms would you expect to see?
@cashonlyj3469
@cashonlyj3469 2 жыл бұрын
I heard you was out of country Gov. stuff hopefully with good guys.
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Taddy's coming back to a city near YOU
@luissalas9270
@luissalas9270 2 жыл бұрын
I want to join
@TaddyDigest
@TaddyDigest 2 жыл бұрын
click the join button and send me an email tadfuller1@gmail.com
@EarthCamper
@EarthCamper Жыл бұрын
1 ton?
@TaddyDigest
@TaddyDigest Жыл бұрын
Is that a question
@heatncool
@heatncool 2 жыл бұрын
Carrier is full of themselves. Private label all the way. "Lifetime unit replacement warranty" customer only purchases unit from us "once" in a lifetime. 🧠
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Interesting
@heatncool
@heatncool 2 жыл бұрын
@@TaddyDigest I installed a bunch of airquest, Heil, tempstar... it's all made by carrier. I've also put in Carrier commercial packaged units. They threatened to take us to court for putting they're logo on our website... now with private label our average service tickets are 20k lieftime unit replacement warranty- 10 year can't write a check gaurantee and filter replacement programs. 😀 everything works for the best. One thing I can agree with about carrier is, they did a nice job "circling the problem" ROFL 😂
@boduke2299
@boduke2299 Ай бұрын
Im stuck on if i should install a 7/8 or 1 1/8 suction line on a 5 ton unit that has a line set run of about 70 ft which way would you go.
@TaddyDigest
@TaddyDigest Ай бұрын
I would definitely install 1" and eighth
@boduke2299
@boduke2299 Ай бұрын
@TaddyDigest that's the way I was leaning thanks for your opinion appreciate it.
Refrigeration Cycle 101
10:36
HVAC School
Рет қаралды 835 М.
invideo ai 1080 Get $16,000 in Rebates for Heat Pump Ins 2024 06 30 1
1:09
Gemini’s-heating & Cooling LLC
Рет қаралды 40
마시멜로우로 체감되는 요즘 물가
00:20
진영민yeongmin
Рет қаралды 33 МЛН
Little girl's dream of a giant teddy bear is about to come true #shorts
00:32
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 7 МЛН
Installing AC Refrigerant Line Set to Condensing Unit
14:32
The HVAC Hacker
Рет қаралды 3,8 М.
HVAC Installation: Brazing Refrigerant Lines
7:35
Stephen Rardon
Рет қаралды 4,5 МЛН
AC Pressures, Subcooling and Superheat
29:52
HVAC School
Рет қаралды 252 М.
Refrigerant Piping Design Basics
4:48
MEP Academy
Рет қаралды 8 М.
How to Braze Air Conditioning Copper
11:23
HVAC School
Рет қаралды 387 М.
Copper Tube Bending Tools & Methods! Lever Type, Ratcheting, Spring, Hands!
8:08
An Awesome Alternative To Brazing HVAC Lines. Staybrite 8 Soft Solder
13:45
Oxy-Acetylene Brazing 3D
15:47
HVAC School
Рет қаралды 145 М.
SHOULD you replace your LINESETS when you get a NEW HVAC SYSTEM?
9:06
HVAC Guide for Homeowners
Рет қаралды 18 М.