Raceway (conduit) Fill Pt 1

  Рет қаралды 12,685

Ryan Jackson

Ryan Jackson

11 ай бұрын

This is Part I of II covering conduit fill. This video focuses on the requirements, whereas Part II focuses on the calculations.

Пікірлер: 29
@ROBERTELECTRIC1
@ROBERTELECTRIC1 3 ай бұрын
Thanks Lot. You make over complicated Code book very simple understandable. God Bless You.
@user-kr2lk2ri2p
@user-kr2lk2ri2p Ай бұрын
Great video! Thank you for making these incredible videos and sharing your knowledge!
@eepower
@eepower 11 ай бұрын
As always great explanation with great illustrations. Thanks Ryan for sharing your knowledge and expertise. Your contribution to the trad is much appreciated.
@lukasvilla2657
@lukasvilla2657 10 ай бұрын
You are very knowledgeable. I am a first year apprentice. This helps alot. Thank you.
@RyanJacksonElectrical
@RyanJacksonElectrical 10 ай бұрын
Glad to help!
@herbertvela9545
@herbertvela9545 7 ай бұрын
I love the way you teach you really helping me out in my school. Thank you so much.
@ElectricalTime
@ElectricalTime 8 ай бұрын
Hi Ryan, excellent video on Raceway / Conduit Fill, look forward to Part II of this series, thanks, Steve K
@altuber99_athlete
@altuber99_athlete 8 ай бұрын
As your photo clearly showed, I think the NEC should address conduit fill for large gauge wires and/or large diameter conduit with small gauge wires. For example, 54 #10-AWG THW wires in a 2” EMT, or 10 #2-AWG THW wires in a 2” EMT, are both crazy (hard to work with and to do maintenance or inspection) yet it’s code compliant.
@matthewb1601
@matthewb1601 10 ай бұрын
I learned things because of this video. Thank you!
@ScipioAndycanus
@ScipioAndycanus 11 ай бұрын
Great stuff, Ryan. Thank you, sir.
@chadgerman7467
@chadgerman7467 5 ай бұрын
awesome video my friend!!!! the King of tehcode
@allegreUno
@allegreUno 5 ай бұрын
Thank you. Appreciate your hard work.
@luissegura4401
@luissegura4401 9 ай бұрын
Best video ever
@OhmMyGod1
@OhmMyGod1 2 ай бұрын
Excellent discussion, and a very thorough analysis Ryan. However, as pertaining to the NM cable calculations at 36:17 I believe if you had two 12-2 cables you would be limited to 31% of the Cross -Sectional area not 40% of the conduit per Chapter 9 table 1.
@rubenmartinez243
@rubenmartinez243 Ай бұрын
I was about to ask they same.
@pld8993
@pld8993 28 күн бұрын
Correct.
@citygirljace
@citygirljace 11 ай бұрын
19:47 - Just what someone with the “Steel Tube Institute” would say 👀
@RyanJacksonElectrical
@RyanJacksonElectrical 11 ай бұрын
Of course! LOL
@SB-dc9qb
@SB-dc9qb 10 ай бұрын
Thank you
@yvonneagundez1994
@yvonneagundez1994 3 ай бұрын
Enjoy the talk . With 24" raceway 60% fill, do you got to factor derate rule. And up size wires.?
@RyanJacksonElectrical
@RyanJacksonElectrical 3 ай бұрын
You do not need to apply ampacity adjustments for raceways shorter than 24".
@dan9372
@dan9372 11 ай бұрын
In the field.
@dan9372
@dan9372 11 ай бұрын
Would a micrometer be an acceptable calculation method?
@RyanJacksonElectrical
@RyanJacksonElectrical 10 ай бұрын
I would think so.
@stevehume5204
@stevehume5204 5 ай бұрын
Ryan....doesn't the .8 rule allow 2 12/2 in a ¾ emt?
@smittylikesto
@smittylikesto 9 ай бұрын
😁
@user-jr1je2px6i
@user-jr1je2px6i 10 ай бұрын
Were is part 2?
@RyanJacksonElectrical
@RyanJacksonElectrical 10 ай бұрын
Two weeks
@jonathancarver8856
@jonathancarver8856 11 ай бұрын
sound is low
Raceway (conduit) Fill Pt 2
43:40
Ryan Jackson
Рет қаралды 6 М.
100 Days of Article 100: Service (and everything that goes with it)
20:41
Happy 4th of July 😂
00:12
Alyssa's Ways
Рет қаралды 63 МЛН
Can You Draw A PERFECTLY Dotted Circle?
00:55
Stokes Twins
Рет қаралды 50 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 33 МЛН
Русалка
01:00
История одного вокалиста
Рет қаралды 6 МЛН
Conduit Fill / Different Insulation types
9:41
Craig Michaud- Electrical Instructor
Рет қаралды 54 М.
National Electrical Code (NEC) Box fill calculations
25:17
Ryan Jackson
Рет қаралды 33 М.
#1 DIY Electric Mistake - Can you use Romex Wire in Conduit?
3:44
Silver Cymbal
Рет қаралды 795 М.
2023 NEC changes: GFCI protection (210.8)
32:47
Ryan Jackson
Рет қаралды 100 М.
Neutral-to-Earth Voltage (NEV), NEC 2020, (44min:40sec)
44:40
MikeHoltNEC
Рет қаралды 216 М.
Electrical conductor types in the NEC
28:03
Ryan Jackson
Рет қаралды 12 М.
Kitchen islands and peninsulas in the 2023 National Electrical Code
17:14
Motors: Conductor sizing and overcurrent protection
58:34
Ryan Jackson
Рет қаралды 5 М.
Current carrying conductors in the 2020 NEC
22:04
Ryan Jackson
Рет қаралды 37 М.
АЙФОН 20 С ФУНКЦИЕЙ ВИДЕНИЯ ОГНЯ
0:59
КиноХост
Рет қаралды 1 МЛН
Мой инст: denkiselef. Как забрать телефон через экран.
0:54
Как правильно выключать звук на телефоне?
0:17
Люди.Идеи, общественная организация
Рет қаралды 1,6 МЛН
Красиво, но телефон жаль
0:32
Бесполезные Новости
Рет қаралды 1,2 МЛН