BEST Generator Cord is the One you Can Make Yourself

  Рет қаралды 206,928

Silver Cymbal

Silver Cymbal

Күн бұрын

How to make a Generator Cable that's BETTER than any one you can buy. 100% Copper construction extension cord is built to last forever with heavy duty cable & dependable construction.
Parts I used:
Cable: amzn.to/3HyJWis
Cabile Jacket Cutter: amzn.to/34hgsax
Cable Organizer: amzn.to/3HEYLQr
Strippers: amzn.to/3oyw6oy
Male Plug: amzn.to/3uyav3I
Female Plug: amzn.to/3ornr7x
Ferrule Kit: amzn.to/3ow5XXL
Nothing in this video was sponsored - Always follow your directions, this video is not a step by step guide, your situation may be different and electrical laws may vary from yours.
Update: The Pass Seymour plug I use has removable inserts in the clamping mechanism in the back of the plugs. This should be removed (not done in the video) for larger sized cable. Always refer to your specific instructions for the plugs. Thanks to a viewer for pointing this out.
This video, description & comments may contain affiliate links, which means that if you click on one of the product links, I’ll receive a small commission. This helps support the channel & allows me to continue to make videos like this. Thank you for the support!
Check me out on Instagram for great photos and more project updates
/ silvercymbal
Disclaimer:
Due to factors beyond the control of Silver Cymbal, I cannot guarantee against improper use or unauthorized modifications of this information. Silver Cymbal assumes no liability for property damage or injury incurred as a result of any of the information contained in this video. Use this information at your own risk. Silver Cymbal recommends safe practices when working on machines and or with tools seen or implied in this video. Due to factors beyond the control of Silver Cymbal, no information contained in this video shall create any expressed or implied warranty or guarantee of any particular result. Any injury, damage, or loss that may result from improper use of these tools, equipment, or from the information contained in this video is the sole responsibility of the user and not Silver Cymbal.

Пікірлер: 181
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Thanks for watching please LIKE & SUBSCRIBE - Strippers: amzn.to/3oyw6oy Cable Organizer: amzn.to/3HEYLQr Other parts in the description
@gonzostwin1
@gonzostwin1 2 жыл бұрын
Know how many cords I've bought off the shelf that weren't even gauged to the rating it marketed. Started making my own and been handing making lamp cords for wall scones
@obeidakassem1117
@obeidakassem1117 2 жыл бұрын
​@@gonzostwin1 ilol lo ooññ
@tdotbones
@tdotbones Жыл бұрын
Hello, can you use this gauge SOOW wire if wish to make up a plug with a 50A male end/plug going to a generator, and 50A female twist lock going to 50A inlet box? Thanks! Love your channel!
@gergc4871
@gergc4871 2 жыл бұрын
Another good rule is to turn the breaker off before plugging/unplugging a cable and locking/unlocking it. There can be an arc if not which will degrade the prongs over time.
@SilverCymbal
@SilverCymbal 2 жыл бұрын
That really is excellent advice!
@sebastiannielsen
@sebastiannielsen 2 жыл бұрын
Shouldn't be neccessary if things are set up right. Normally you would have a generator interlock switch. With the generator interlock switch set to MAINS, just connect generator cord and there will be no sparks. Then flip the interlock switch to GENERATOR and thing will be running. Before pulling out, just flip interlock switch to MAINS to remove the load from the generator.
@allkindsofoutdooractivities
@allkindsofoutdooractivities 2 жыл бұрын
Great instruction! I had to build a 240 volt “extension” cord because our window unit’s cord was too short lasted at least 15 years before we moved. Never an issue
@n2rj
@n2rj 2 жыл бұрын
I really love those receptacles where the wire goes straight through rather than wrapping around the screw. My Generlink cable apparently was custom made.
@MakerDIY
@MakerDIY 2 жыл бұрын
Worth building for the custom length alone! Thanks for another great video!
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Much appreciated
@sikhswim
@sikhswim 2 жыл бұрын
Great example of doing things correctly with all the right tools. Nice!
@ceefusjenkins2281
@ceefusjenkins2281 2 жыл бұрын
I'm so glad you brought out the wire ferrules! I was just about to comment on how much easier they make things.
@tracycrispino3446
@tracycrispino3446 2 жыл бұрын
I have made several of these cables but didn’t use ferrules. That was a nice touch and I will try them next time. Nicely done brother 👍
@allcrafter3747
@allcrafter3747 2 жыл бұрын
Do not try them next time. Add them immediately. Without them it is very dangerous and can course fires
@tracycrispino3446
@tracycrispino3446 2 жыл бұрын
@@allcrafter3747 got it..will do and thanks for the reply!
@emmettturner9452
@emmettturner9452 2 жыл бұрын
I had the same thought. I had the crimp set and everything but didn’t think to use them even though I felt uneasy with the stranded wires in one end of my EVSE pigtail cable. My mindset was that the ferrules were for my 3D printer stuff or terminal blocks in my other electronics work so I never even thought to use them. I will be redoing it immediately!
@TomCee53
@TomCee53 Жыл бұрын
Make sure you use ferrules designed for the wire size, and not just a pin connector designed for speakers. And don’t try to crimp with regular pliers. Another option is to tin the wires with solder to ‘solidify’ them.
@seangholipour3884
@seangholipour3884 Жыл бұрын
@@TomCee53 that’s exactly what I was thinking tin them wires, better and cheaper
@thegonzo3514
@thegonzo3514 2 жыл бұрын
Nice video. Well done and enough detail for a DIYer to tackle the job.
@r0cketplumber
@r0cketplumber 2 жыл бұрын
The outermost insulating layer is often called sheathing to differentiate it from the insulation on the individual conductors.
@redpillcommando
@redpillcommando 2 жыл бұрын
I have a ferrule crimping tool and I love it.
@thetheflyinghawaiian
@thetheflyinghawaiian 2 жыл бұрын
I work in an industrial research facility from the 1900s where the polarity of the outlets is random, so I do this 20-30 times to get the machines spinning in the right direction when we setup a new test plant. Handy design, and I concur, they last forever. We are very hard on these.
@dogwalker666
@dogwalker666 2 жыл бұрын
Buy a phase rotation indicator, I made sure the whole factory was phased correctly.
@TomCee53
@TomCee53 Жыл бұрын
@@dogwalker666 phase rotation is only an issue with three phase power, which is highly unlikely in home use.
@dogwalker666
@dogwalker666 Жыл бұрын
@@TomCee53 I suggest your re read the OP he said "Industrial Research facility", So not domestic, He also said the rotation of machines which means he was talking about 3 phase sockets, Probably CeeForm.
@xsauce3858
@xsauce3858 2 жыл бұрын
You know it's a good cable when it's the size of a garden hose
@rickgaine3476
@rickgaine3476 2 жыл бұрын
very well explained and presented.
@FadedHero636
@FadedHero636 2 жыл бұрын
I've made PC power cables out of shielded 12/3 SOOW cable. They are the best cables I've ever had for a PC.
@abecoulter8550
@abecoulter8550 2 жыл бұрын
that cable is very well used for caravans/ RVs and the live entertainment industry in america, hence the rugged outer jacket
@1ronhall
@1ronhall 2 жыл бұрын
Nice work SC!
@Sentieantbeing
@Sentieantbeing 9 ай бұрын
I love your vids man im not even following the tutorial im just listening keep up the good work
@CrazyCanuckFitness
@CrazyCanuckFitness 2 жыл бұрын
excellent instruction. thank you
@johnnyray34
@johnnyray34 2 жыл бұрын
I have been unsure if I should make my own or just by it. I need 40 ft 30 amp but this video is making want to give it a go. Nice informative video.
@TomCee53
@TomCee53 Жыл бұрын
#10 will still handle 50 ft, but I’d probably upsize to #8 if I could afford it.
@fredthompson2501
@fredthompson2501 2 жыл бұрын
Nice job one thing on the plugs you need to remove the black spacers from the clamps on end of plugs it is crushing wire unevenly.
@victorpayne6586
@victorpayne6586 2 жыл бұрын
Good job. Thanks
@gergc4871
@gergc4871 2 жыл бұрын
That gasket will wear over time. I've found that replacing it with rubber (standard bicycle inner-tube) works well. Unfortunately, most times you won't realize this is necessary until it shorts out.
@SilverCymbal
@SilverCymbal 2 жыл бұрын
I think that one is edpm but you could be right, just from use. I like the tube idea that seems like an ingenius quick fix!
@gonzostwin1
@gonzostwin1 2 жыл бұрын
When running hps lights knowing how to make lines is life saving instead of relying on off the shelf extension cord
@larryk5823
@larryk5823 10 ай бұрын
Thank you. Your video helped!
@quinnlandry1648
@quinnlandry1648 2 жыл бұрын
Great Video!
@raymondgarafano8604
@raymondgarafano8604 Жыл бұрын
YUP, I made one after I bought a nice Powerhorse gen running watts 7200 120/240 30 amps from Northern Tool & Equipment. A good rugged cord is safer, you don't want any abrasiveness where wire could be exposed and sitting in a puddle. I have a male fitting at each end, I know it is a widowmaker, BUT after you shut the MAINS OFF and plug into the dryer, knowing its wiring is protected by a 30 amp fused double pull-out or double-breaker you are all set. Silver Cymbal did a VERY professional job here and that cord set will last forever. I am sure he will make sure it is dry when he hangs it up to prevent dry rot. Two thumbs up.
@dinm65
@dinm65 2 жыл бұрын
your videos are the best!
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Wow, thanks!
@josevictorino7338
@josevictorino7338 2 жыл бұрын
Awesome 👏 👍
@Original_SJB
@Original_SJB 2 жыл бұрын
great video!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
@abecoulter8550
@abecoulter8550 2 жыл бұрын
another tip to slide that weather grommet or seal, use a bit of cornstarch or talc powder to act as a lubricant
@Barbaratio
@Barbaratio 2 жыл бұрын
Silicone/Die electric grease works for that as well
@tylerm.9408
@tylerm.9408 2 жыл бұрын
Quick question, is that style of plug what is used for RVs? I was looking for a good cable to hook up an EcoFlow Delta to a very small travel trailer for power.
@johnqcitizen3339
@johnqcitizen3339 11 ай бұрын
I was trying to decide which wire to use between the gen anf the transfer switch, you mentioned the SJOW, we have a small home with no air so the second hot is not needed ( I think) ? can you make a recomendation? ThankYou
@joeglennaz
@joeglennaz 2 жыл бұрын
How do you learn or know how to do all these interesting things? I Enjoy your videos
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Much appreciated, thank you
@jakeliujakeliu
@jakeliujakeliu Жыл бұрын
For the wire cutter when you cut those cable, some small wire is cut off. Will that affect quality of final power plug? Or you need to redo it until it perfect no small wire should be cut.
@MrDavez
@MrDavez 8 ай бұрын
I need to make a L-14 30P to a 10-50P so it plugs into my existing 50A compressor plug. Was given a Black Max 8125 Honda Powered Generator not running. 1 carb clean and governor adjustment later, she's ripping 60 Hertz @ 120v. But the output is a 30A instead of the 20A on my older Generac 4000. Priced parts to make 25ft cable for me as seen in video,, at Menards 10/16/23 for 80 bucks Thanks for the info.
@troyd.521
@troyd.521 Жыл бұрын
So it’s ok if you don’t get the hot wires in the same terminal on each plug?
@MrTooTechnical
@MrTooTechnical 2 жыл бұрын
Soow woohoo. The best. Great vid
@sampon597
@sampon597 Жыл бұрын
Can the Ferrules Crimping kit handle 6 AWG wires?
@dwaaziwaazi
@dwaaziwaazi 2 жыл бұрын
Are you going to test the Duromax 9000?
@scottmurphy4946
@scottmurphy4946 Жыл бұрын
Sounds dumb but in my area of canada, it's cheaper to buy pre made cables than the cable/ ends separately. Well depending on the length
@mechatronx4383
@mechatronx4383 9 ай бұрын
what's the difference between these plugs and the common L14-30P?
@drrobotnikmeanbeanma
@drrobotnikmeanbeanma Жыл бұрын
Stack up on some heavy duty extension cords.Get them asap.Get the ones with a lot of watts that says heavy duty.If you get them now you don't have to worry about getting them incase of an power outage.Try to get the 100ft heavy duty extension cords
@SkyHawk2849
@SkyHawk2849 Жыл бұрын
If I have a 3 prong generator cord, can I make both ends 4 prongs and get 240v? Or will this not work?
@ViciousXUSMC
@ViciousXUSMC Жыл бұрын
Good Video, wonder if price per foot is cheaper in DIY vs pre-fab, DIY definitely better if you need a specific length though. So Ferrules I use when I am working with small wire, helps get a good connection, makes wiring easier, but makes me feel a bit off thinking of using them on something like a 6ga 50amp connection, I would be afraid of loosing some conductivity not having the terminal clamp be able to really "bite into" the cable, and the added resistance of the ferrule itself vs pure copper.
@interstellarconundrum4774
@interstellarconundrum4774 9 ай бұрын
Much more expensive to DIY. That's because the quality of the American made cable is far better than the Chinese crap. You get what you pay for .
@billylee2907
@billylee2907 Жыл бұрын
Will the cord be able to handle a 50 amp load?
@nannerz1994
@nannerz1994 2 жыл бұрын
can confirm, this is what we use in the film industry.
@mattwaters6987
@mattwaters6987 5 ай бұрын
Excellent video sir! Question...is it actually cheaper to build your own vs pre-built?
@SilverCymbal
@SilverCymbal 5 ай бұрын
Thank you, its definitely not cheaper to build your own. But you are getting much better components if you do but its hard to ignore the inexpensive cords for infrequent use
@dannymeil3294
@dannymeil3294 9 ай бұрын
How do you wire a 4 prong male generator plug into a 3 female 240 welder outlet?
@donavonmasters2917
@donavonmasters2917 Жыл бұрын
What kind of multimeter are you using
@truesimplicity
@truesimplicity 2 жыл бұрын
Poo... I used the same Velcro strap fro HD works really well... Thanks for the vid like the ferrules, great Idea.
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Thank you, those straps are pretty good. I first wasn't sure but I burned through the pack in like 2 weeks now I want more. amzn.to/3HEYLQr
@superchill27
@superchill27 Жыл бұрын
Where do I get SOOW 3 wire cable
@emmettturner9452
@emmettturner9452 2 жыл бұрын
Thanks. I have a ferrule crimp set but didn’t think to use it for my EVSE pigtail even though I felt uneasy with the stranded wire. I’ll go back and add ferrules. :) It’s a Level 2 J1772 EVSE (“240v car charger”) with a 4-prong NEMA 14-30 plug. The Chevrolet Volt only draws 20A so I adapted it to fit a NEMA 6-20 at the workshop using my pigtail. The outlet originally had 240v going to a normal-looking NEMA 5-15 (!) and I didn’t know until it fried my 110v work lights! The lease says I’m not supposed to do anything with 240v but thanks to their negligence I can play dumb, especially since the same EVSE supports 110v (Level 1 charging). On that note, you will get a TON of views if you make a version of this video for that audience. Common household 240v plugs in North America range from NEMA 6-20 to NEMA 14-30 and 14-50… and you don’t typically get to pick what your Level 2 charger has. Heck, some “stealth” Level 2 chargers are sold as Level 1 chargers with a standard 110v NEMA 5-15 plug… one only needs to adapt it for Level 2 charging on 220-240v.
@emmettturner9452
@emmettturner9452 2 жыл бұрын
Some of the portable Level 1 EVSEs included with the Chevy Volt were actually stealth Level 2. Ours is one of them but it has a broken J1772 plug. When I can find a replacement J1772 that doesn’t cost as much as another EVSE then I’ll be making a whole set of pigtails for that one. :)
@greendinoscave
@greendinoscave 2 жыл бұрын
Not sure if this is how everyone does it in America but normally in AUS/NZ we make the Earth or for Americans "ground" slightly longer so in the event the cable gets pulled out from the plug the earth will be the last to lose connection making it safer. Is this something that is considered over there?
@TomCee53
@TomCee53 Жыл бұрын
Some people do that. I’ve seen some connectors with the ground terminal raised to do that.
@rodneyjohnson7327
@rodneyjohnson7327 Жыл бұрын
My generator is 8750 starting watts and 7000 running watts. What cable can I use that is rated for almost 9000 watts? 10 gauge is rated for 7500 watts. Since it will be plugged into the 30 Amp/240 volts plug on the generator will the plug and wire used in this video work?
@leamsi4ever
@leamsi4ever 2 жыл бұрын
would like to see a video about that meter you used
@PaulHigginbothamSr
@PaulHigginbothamSr 2 жыл бұрын
My generator while it does make 240v it does not have a 240v plug in. So the first thing I will need to do is install a 240v plug in beside my 120v plug ins. When using the 240v plug in I will need to block my 120v outlets. My genset does not produce 30 Amp service so will need to limit my 240v outlet to 15 amps per leg.
@innerjon
@innerjon 2 жыл бұрын
Could you also “tin” the ends of the connections?
@andrewt9204
@andrewt9204 2 жыл бұрын
Maybe if you just do the very tip to stop it from fraying, but that's it. The problem is the solder easily wicks up the wire and goes past the insulation point, making it difficult to work with. Also, if there's a problem, and the connection gets hot, the solder can melt and make a loose connection even worse. I've done it for a few of these plugs, but ultimately I re-did them with ferrules or just bare copper strands.
@MLFranklin
@MLFranklin 2 жыл бұрын
We used to do that with a lot of wiring, but there is a risk that the tinning will wick further up the wire and make it hare, then the wire breaks right at the transition between tinned and clean stranded. EDIT: In fact I was watching what the current state of the art is for automotive wiring and they said that a good crimp is preferred and that some folks will not allow tinned wires in motorsports.
@dperez-tv1lr
@dperez-tv1lr 2 жыл бұрын
Sweet
@Mihogan
@Mihogan 4 ай бұрын
Hey just wanted to point out, I think you linked the wrong male plug piece. Your link goes to an L15-30 plug but it should be an L14-30 plug I believe.
@jonathan69278
@jonathan69278 2 жыл бұрын
Being an electrician… idk why I started watching this
@michaeldoyle5001
@michaeldoyle5001 2 жыл бұрын
Amazon has complaints about the Jokari stripper blade moving around and not making a ragged cut. Did you have any issues with this?
@SilverCymbal
@SilverCymbal 2 жыл бұрын
I saw some of those. The cuts I have gotten are razor clean as you can see in the video, follow their instructions but I just it it on and I usually push the tool away from me to cut, not sure if thats why it works well but its been a nice tool for me.
@jimharden4823
@jimharden4823 Жыл бұрын
Solder or led the end’s
@lance16O1
@lance16O1 2 жыл бұрын
I'm guessing in lieu of ferrules you could tin the ends with solder?
@SilverCymbal
@SilverCymbal 2 жыл бұрын
No, solder should never be used in any fitting the clamps it down, while solder is wonderful for wire to wire connection it has terrible properties when crushed down. I know we tin speaker wires but those are not compressed. Just use raw wire as is if you don't use ferules (which is totally fine to not use ferrules)
@cravejdm
@cravejdm 2 жыл бұрын
On those plugs there are little black pieces we’re the wire gets tightened down out you could have removed them so the wires are not being pinched.
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Yes, I added a note in the description about removing these. I should have followed their instructions better!
@defiorem742
@defiorem742 2 жыл бұрын
Can you do a video on how to make a 50 amp cord?
@TomCee53
@TomCee53 Жыл бұрын
Pretty much the same technique. For 50A you’ll need the right connector (there are several ) and use 6 gauge wire.
@hs9917
@hs9917 8 ай бұрын
You make that look so easy can you make me a 50 amp generator cord for my Duramax 15000 watt generator? How much? I need it to be 25 ft long
@philipdamask2279
@philipdamask2279 Жыл бұрын
You should state the cost for parts.
@zacharykorbet9690
@zacharykorbet9690 2 жыл бұрын
Hey man I got a question do you think that I could use 8 gauge wire?
@TomCee53
@TomCee53 Жыл бұрын
You can generally always upsize, and is recommend it for a run over 50 feet.
@toddshreve
@toddshreve 2 жыл бұрын
It looks like the receptacle covers on your eu7000i are starting to yellow like mine. Annoying! Al though I only think about it when I see them, so not *that* annoying.
@tulw2728
@tulw2728 2 жыл бұрын
Will this cable be good enough to pass power from 4 batteries to a 3000 watts power inverter in a semi truck? I looks very flexible and well insulated. Thank you.
@rascalpup5237
@rascalpup5237 2 жыл бұрын
No, the amperage would be too high. A=W/V (Amps = Watts / Volts) If the truck is a 24V system, you would be running roughly 125A between the battery and inverter. A 12V system your closer to 250A. Often inverters of this size will have 2 or more lugs for each + and - connection to allow you to run a couple beefy wires to them. We are talking 1/0 or 2/0 gauge or larger depending on the distance of the run, conductor type, and ventilation available (something people forget when they install these things. The more amperage in the wire, the more heat it gives off, and if there is limited or no ventilation, the heat can build up leading to fire.) If you have a good inverter, you should have several lugs letting you run smaller gauge wires in bundles to help make the install easier and safer. Best advice I can give is, if you're not sure, your better off bringing it to a pro to install. This covers you for anything that goes wrong from the inverter being damaged to the truck burning up due to bad installation (insurance company's love to deny claims now-a-days, don't give them an excuse.)
@tulw2728
@tulw2728 2 жыл бұрын
@@rascalpup5237 Thank you very much for your reply. Yes. I will let a professional run the installation on this inverter for me. Thank you again.
@religionsisaboutmagic5835
@religionsisaboutmagic5835 10 ай бұрын
Good video. Have a question..... My home has only WHITE, BLACK, and ground, but no RED wire. So, how would I wire the plug without a RED wire. Was thinking of running a jumper from where the black wire goes into the back of the plugs to where the red goes..
@pinkiepie1656
@pinkiepie1656 8 ай бұрын
Your home has two blacks. That's your red.
@religionsisaboutmagic5835
@religionsisaboutmagic5835 8 ай бұрын
@@pinkiepie1656 No, 1 black and 1 white.
@kennygregrich5375
@kennygregrich5375 Жыл бұрын
FYI. The link you posted for the male plug is not the right plug. That one is a 3 phase and I’d not the same.
@wooddawg4868
@wooddawg4868 9 ай бұрын
I don't know about that now. I have a 50 foot cord I bought off amazon for $99 bucks. I would have paid 150 plus doing it myself.
@danhambrick6331
@danhambrick6331 2 жыл бұрын
How many amps are those ferrules rated for?🤔🤔
@SilverCymbal
@SilverCymbal 2 жыл бұрын
There are a lot of companies that make them, here is a spec sheet for a typical 10ga version rated at 50amps - www.ferrulesdirect.com/products/at60010
@bobberbear4622
@bobberbear4622 2 жыл бұрын
Would this be acceptable for a generator with 7000 running watts and 9000 watts peak?
@TomCee53
@TomCee53 Жыл бұрын
9000W is 40A@240v - needs 8 gauge wire.
@dj5752
@dj5752 2 жыл бұрын
Nice video. Where did you get the cable cutter?
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Right here: amzn.to/34hgsax
@dj5752
@dj5752 2 жыл бұрын
@@SilverCymbal thanks missed it.
@dj5752
@dj5752 2 жыл бұрын
The yellow and red cable cutter.
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Sure thing, here: amzn.to/34hgsax
@andrewt9204
@andrewt9204 2 жыл бұрын
I think you're supposed to remove those 2 black spacers on the cable clamp for SOOW cable, I think it's pinching it too much. I made some extensions just like this a few months ago with that same exact cable and plugs. Removing those spacers clamped more "around" the wire, with enough thread room to spare. The white body also has ridges to make a good mechanical clamp. Pinching a cable that hard may make it crack/split earlier than intended. But great video otherwise!
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Yes, I added a note in the description about removing these. I should have followed their instructions better!
@mikehrdlicka8635
@mikehrdlicka8635 2 жыл бұрын
I started as a maintenance worker. Fix that and that. The co worker was making a cord for a labler or something. 110 volt I asked why are you crossing the black and white wire over each other?
@mikehrdlicka8635
@mikehrdlicka8635 2 жыл бұрын
He stated so polarity is correct. I said use other end of cord you won't have to cross over each other. I was surprised he didn't know that.
@user-mg7nz6ut2k
@user-mg7nz6ut2k Жыл бұрын
Вітаю! Скажіть як з L14-30 які з 4 проводів з'єднати до вилки європейського стандарту. Передали бензогенератор з США в Україну. Дякую
@massfusion
@massfusion 2 жыл бұрын
Do i have a generator? No. Do i need this cable? No. Will i ever get a generator and use this? No. Did i enjoy this video while having dinner? Yes absolutely. Great content man keep it up
@MAXKC1
@MAXKC1 2 жыл бұрын
How much did everything cost?
@poyim256
@poyim256 Жыл бұрын
Cant find that kind of crimper in our country 😢
@Desertjoe789
@Desertjoe789 2 жыл бұрын
Anyone who’s been around generators or trailers or boats with these plugs knows how horrible they are. I wish they would make a new better standard for these connections. That cable will not last a lifetime. They don’t make a good connection after a while which causes resistance and heat and those brass tabs burn up.
@MLFranklin
@MLFranklin 2 жыл бұрын
Interesting and scary. Is that in a freshwater or seawater environment? I wonder if the military has a better solution?
@Desertjoe789
@Desertjoe789 2 жыл бұрын
@@MLFranklin its anywhere these plugs are used not just boats. there are better solutions but they are proprietary, they also make a marine one. I can't remember the name or brand right now.
@TheTheo58
@TheTheo58 2 жыл бұрын
@@Desertjoe789 Could the brand your thinking of be Hubell?
@eosjoe565
@eosjoe565 2 жыл бұрын
Actually, the 20-foot cable I purchased for my generator uses the same wire and connectors.
@bmay8818
@bmay8818 2 жыл бұрын
I dunno, it seems to me that ferrules are a bad idea in this application. The clamps on the plug are designed to squash the strands flat, making good contact, but ferrules limit the contact area to only two points. I think it's a great idea to use them in applications where the connection is designed for solid wire, but these plugs are designed to use stranded.
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Consider this, all residential outlets are wired with solid wire. When you form a hook and screw it down, only the outer edges make contact with the outlets, but they don't overheat because solid wire is of course solid. Ferrules compress stranded wire and turn it almost into a solid conductor allowing an excellent connection. In almost every country outside the US. The use of ferrules is required by law, NO loose stranded wires are allowed because ferrule connections are superior with stranded wires. Please do whatever you are comfortable with but ferrules are pretty amazing little things for stranded wire.
@bmay8818
@bmay8818 2 жыл бұрын
@@SilverCymbal Regular outlets have simple screw terminals for solid wire, and the top, bottom, and inside parts of the wire loop make contact with the screw. Outlets designed to use stranded wire have a pressure plate, like the one on your plug, in addition to the screw. When I wire my shop, I'll use stranded for everything, which requires me to use ferrules at the breakers (which are listed for solid wire) and those fancier outlets with the pressure plates. One can't use stranded with a regular screw terminal, and I wouldn't convert stranded into solid using ferrules on a device (like your plug) that is designed to use stranded directly.
@huskkyy
@huskkyy 2 жыл бұрын
@@bmay8818 The same spec NEMA connectors are used in Australia for commercial uses, they are required to use ferrules and this exact same part number is used here and certified to AU/NZ specs. I can't speak about your shop but pressure plate fittings are perfectly fine with ferrules like the ones found on this connector! Im a qualified electician and electrical engineer if that helps change your mind haha.
@scottmurphy4946
@scottmurphy4946 Жыл бұрын
@@SilverCymbalShorts158 scamming ass
@hksjoshua
@hksjoshua 9 ай бұрын
That is correct with the ferrules installed you are limited in wattage / amperage due to lack of surface contact.
@RSole9999
@RSole9999 Жыл бұрын
These connectors are not waterproof at all regardless of that rubber grommet. There are always gaps between the two halves clamping the sheathing. Also, the connectors are not rated as waterproof by the mfr.
@roboticmind23
@roboticmind23 2 жыл бұрын
why didnt you remove the black inserts in the cable clamp portion? you are squeezing down on that insulation way too hard
@SilverCymbal
@SilverCymbal 2 жыл бұрын
By the time you get those out its just as easy to split the clamp and you won't be able to get them back in even with the clamp fully extended with this cable, the pins on them add another 1/4" to each side.
@N-hunter
@N-hunter 2 жыл бұрын
@@SilverCymbal the black pieces in the clamp are designed to be removed when using larger cable sizes. The screws do not need to be tightened all the way, just enough to clamp the cable. From what I can tell in the video, the clamps are overnighted, which is bad for the cable and insulation integrity
@SilverCymbal
@SilverCymbal 2 жыл бұрын
@@N-hunter You are correct, I went back to Pass Seymours install guide and for this cable size those clamps can be removed. I appreciate you noticing this and will add it to the description as well if buyers choose this model plugs. Details matter! Thanks
@johnmicalizzi126
@johnmicalizzi126 2 жыл бұрын
You really didn't show us how to connect the connectors the white with the black grnd
@SilverCymbal
@SilverCymbal 2 жыл бұрын
All 4 wires go in as shown I listed a color guide and read off each wire WGRB and where they connect on the outlet
@PutEmInTheBox
@PutEmInTheBox 2 жыл бұрын
Give it a twist before you put it in.
@Eyore82
@Eyore82 2 жыл бұрын
I bet harbor freight tries to get this video banned! 🤣
@joeythefoxxo
@joeythefoxxo 2 жыл бұрын
They want us to buy their $20 cable lmao.
@yzmoto80
@yzmoto80 2 жыл бұрын
Forever huh !? Who’s gonna verify that ?
@dogwalker666
@dogwalker666 2 жыл бұрын
Strange cable colours.
@imperialdoggo5826
@imperialdoggo5826 Жыл бұрын
White is neutral, green is ground, red and black are split phase hots.
@dogwalker666
@dogwalker666 Жыл бұрын
@@imperialdoggo5826 that's confusing to a European, we use, Live is brown used to be red, Neutral is blue was black, the phase colours were Red Yellow Blue, and are now Brown Black Grey, the Earth is Green with a Yellow stripe.
@imperialdoggo5826
@imperialdoggo5826 Жыл бұрын
I know. You guys have a lot better of a electrical setup than us.
@dogwalker666
@dogwalker666 Жыл бұрын
@@imperialdoggo5826 👍🏻
@michaelcarroll1736
@michaelcarroll1736 2 жыл бұрын
Water resistant*
@michaelcarroll1736
@michaelcarroll1736 2 жыл бұрын
Not water proof
@mostlymessingabout
@mostlymessingabout 2 жыл бұрын
America cables and connectors are crazy
@SilverCymbal
@SilverCymbal 2 жыл бұрын
They are, especially compared to the UK ones I have seen, those are like works of art!
@mostlymessingabout
@mostlymessingabout 2 жыл бұрын
@@SilverCymbal i know a lot about those. I do wiring for UK Europe and USA. At least we don't have a 800 pages of NEC and more for each UL standards writen in "code" for us mortals to decypher hehehe.
@mostlymessingabout
@mostlymessingabout 2 жыл бұрын
@@SilverCymbal maybe you want to do a comparison? Collaborative? 🤔
@RichardNixion357
@RichardNixion357 2 жыл бұрын
One male and one Female. There is another option for those who live on the edge.
@phuang3
@phuang3 2 жыл бұрын
It's better to tin each wire end.
@onlywenilaugh6589
@onlywenilaugh6589 2 жыл бұрын
30ft Cable is $131 bucks with inflation. Salty. You can buy 25ft 30 amp already made generator cable for $58. Not sure making yourself and extra few ft are worth $85ish bucks.
@Barbaratio
@Barbaratio 2 жыл бұрын
Haha, mine is male to male
HUGE Electrical Mistake Too Many People Make - Backfeeding
8:22
How To Home
Рет қаралды 118 М.
What is a Suicide Cord and Why It Could Kill You
16:28
Stud Pack
Рет қаралды 1,6 МЛН
THEY WANTED TO TAKE ALL HIS GOODIES 🍫🥤🍟😂
00:17
OKUNJATA
Рет қаралды 3,6 МЛН
Vivaan  Tanya once again pranked Papa 🤣😇🤣
00:10
seema lamba
Рет қаралды 20 МЛН
Receiving LEO Weather Satellite APT transmissions
7:59
MegansProjects
Рет қаралды 3
Why 50% of All Crimp Connections Fail - Up or Down?
4:57
Silver Cymbal
Рет қаралды 1,2 МЛН
92% of Homeowners Use Teflon Pipe Tape Wrong - Here's Why it Leaks
5:33
Silver Cymbal
Рет қаралды 2,2 МЛН
4 Generator Hacks by an Electrician
6:45
abrelectric
Рет қаралды 257 М.
Powering my house with a 4500 watt 120v generator.
11:50
Big Green Shop
Рет қаралды 26 М.
7 Common LED Strip FAILS and How To Avoid Them
12:14
The Hook Up
Рет қаралды 9 МЛН
How To Make The Best Extension Cord [Less than $20]
22:04
Shop Tool Reviews
Рет қаралды 59 М.
Extension Cords On A Generator? No, Yes, Mbe...
6:45
GardenFork
Рет қаралды 127 М.
this is so cool products #vairalshort #walker #nadlyne
0:26
Good Waka car
Рет қаралды 115 МЛН
РЕШИЛ СТАТЬ МИЛИОНЕРОМ С НУЛЯ💵
0:52
MEXANIK_CHANNEL
Рет қаралды 4,6 МЛН