Today I show a sneak peak of the C-tec cfp 4 zone fire alarm panel and show inside the panel. Thank you for watching this video! Like, comment and subscribe for more videos and this will help me put out more videos.
Пікірлер: 44
@yeety12083 жыл бұрын
Thank you for showing me this! It will be helpful when I get a panel!
@j1firesystems4403 жыл бұрын
No problem hope it helps :)
@fst17753 жыл бұрын
Awesome! I cannot wait until you test it :D
@j1firesystems4403 жыл бұрын
Thank you :)
@ElectricEssenceLtd Жыл бұрын
Great video. Keep it up
@ajkhan7433 жыл бұрын
Good video bro great explanation
@j1firesystems4403 жыл бұрын
Thank you!
@AstroDude5003 жыл бұрын
Good video
@j1firesystems4403 жыл бұрын
Thank you :)
@ajkhan7433 жыл бұрын
Please can you make video how to connect 2 panels together please
@momooya28815 ай бұрын
Hi, You said all the detectors has capacitors, I thought a capacitor of 0.47µF 50V should be be fitted only on the last detector of each circuit( end of line). Please correct me if I’m wrong. Thank you
@kkoo42842 жыл бұрын
You not explaining auxiliary power output connection and if you want to upgrade the panel.???
@Monkey33532 жыл бұрын
Hiya mate yeah can you send me the link how are you connect door magnet for the fire alarm wiring please thank you
@yeety12083 жыл бұрын
Why does it have 8 zones labelled of there are only 4 zones?
@j1firesystems4403 жыл бұрын
I think it’s for if you want to expand the zones and if you want to expand I think you need to get a zone expander card. You can then expand the panel to more than 4 zones. I think that is the reason but I am not sure as I have never had to expand the panel. Hope this helps :)
@Dime_Bar Жыл бұрын
@@j1firesystems440 Wrong it's because the circuit board is exactly the same however many zones it maybe, so if you want a 4 zone panel they don't put the components on the circuit board for zones 5 to 8 due to cost. They then do something either programming it or add or removing a component so zones 5 to 8 don't show fault.
@shaanmiah94332 жыл бұрын
@J1 fire systems - Hi I'm to get one the ctec. Where does the Call point connect to, to sounder or smoke detector? does resistor and capacitor comes with the system? Thank u in advance....
@j1firesystems4402 жыл бұрын
If you are wiring together. Yes The call point would wire to the detector and the system does come with resistors and capacitors. Hope that helps :)
@shaanmiah94332 жыл бұрын
Thanks for that info. I have bought very same 2 zone panel. Following the instructions but still showing fault on zone. I'm using smoke detectorActive optical C4416 with base but keep showing fault zone light. I have installed eol to the detector. Thanks you in advance. I'm trying on battery power only if works then will fitted permanently with main
@j1firesystems4402 жыл бұрын
@@shaanmiah9433 Are you sure you have wired your detectors correctly? and have you definitely put an eol on the very last device? Also no problem!
@shaanmiah94332 жыл бұрын
@@j1firesystems440 Hi I've sorted all working good. Actually I got mixed up with capacitors and resistors. So I changed them over and now its working.
@j1firesystems4402 жыл бұрын
@@shaanmiah9433 Ah ok glad it’s working now :)
@yeety12083 жыл бұрын
Where did you get the panel from and for how much?
@j1firesystems4403 жыл бұрын
I got this panel from Safelincs and got this for around 220 pounds for a 4 zone Alarmsense C-Tec panel
@yeety12083 жыл бұрын
@@j1firesystems440 ah OK, thanks!
@j1firesystems4403 жыл бұрын
@@yeety1208 Np :)
@yeety12083 жыл бұрын
@@j1firesystems440 I was thinking about getting an alarmsense panel for Christmas but I managed to win a Zircon 4 zone conventional panel in a bid on ebay for £8.50. I do have some non-alarmsense conventional devices but I'll just have to wait and see what the panel is like when it comes
@yeety12083 жыл бұрын
Here is a picture of the panel: images.app.goo.gl/YVqvy3gAbMNsuNhTA, but the first two zones have been labelled and there are extra stickers (probably from the company who installed the system)