Solar Panel isolator catches fire. Why DIY solar power on your home is not a good idea!

  Рет қаралды 13,560

Joondalup Electrical Services

Joondalup Electrical Services

2 жыл бұрын

Today I was called to a common solar fault that we get in Australia. A DC isolator is faulty and nearly caught fire. I explain why it happened and how to deal with it safely.

Пікірлер: 51
@jamesmason7124
@jamesmason7124 5 күн бұрын
This is why I like to use high quality DC circuit breakers instead of just a switch
@kevinwhelan7858
@kevinwhelan7858 Ай бұрын
Hi I have read a lot of the replys to the video, I hane not seen it mentioned that there are two cables going through the plastic gland, I can not uncerstand why, as it would be so easy to use a second gland,
@squirrel_ca9745
@squirrel_ca9745 13 күн бұрын
First issue is that the isolator is installed on the roof of all places. Best way is to just run cables down to a DC combiner DB downstairs, then install the isolator down there with a DC rated breaker, fuses, surge arrestors. Never install the isolator on the roof…
@BeastMovies
@BeastMovies 8 күн бұрын
Check fuses and Iso to make sure they're rated for your voltage. Lots of fuses say 20amp etc but then 200volts. Noark are 450v max. On a sunny day you can soon go past this voltage but still be under the 20amps. This trips sparky's up when only working with 240v.
@JaaMaar001
@JaaMaar001 Жыл бұрын
Brilliant video, thanks man. This is very dangerous indeed. These things are unsafe in common. There is no way to keep those boxes dry, they should be installed INSIDE and not under cover of a panel!
@herrkiwi3110
@herrkiwi3110 5 күн бұрын
Apparently it is NOT recommended to use external DC isolators in the UK after recent house fires anymore, I believe the newer inverters have them built in. That one your showing looks to have had water ingress. Cheers.
@joondalupelectricalservice3201
@joondalupelectricalservice3201 4 күн бұрын
Yes we have had the same transition here for the same reason also 👍🏻
@robsonrobbi1763
@robsonrobbi1763 Жыл бұрын
I have all wires seperated in individual waterproof boxes for plus and minus that are installed under the roof so they cant even touch each other and then have a disconnect switch in a dry secure area where its the only point they come together. I dont even need to climb up for anything
@unSTEVOED
@unSTEVOED 5 ай бұрын
Its funny how NZ rules say NO roof top isolator, But the Aus rules say yes
@solargoat
@solargoat Жыл бұрын
Great video. Subscribed… look forward to more videos
@joondalupelectricalservice3201
@joondalupelectricalservice3201 Жыл бұрын
just returned the favor and thank you bro.
@Electronzap
@Electronzap 9 ай бұрын
Good info.
@daddio7249
@daddio7249 11 ай бұрын
Will be doing a ground mount but the disconnects will be on wood posts. Might be a good idea to put fire proof material under them. The indoor parts will be on cement board.
@TheSimpleLivingAussie
@TheSimpleLivingAussie 2 ай бұрын
I am guessing the higher the string voltage the higher the chance of arcing ??? I have a few small systems as I love playing with solar (very addictive hobby) and I live off grid out in the Wheatbelt. My 48 volt system runs a panel voltage of 110 volts open circuit and my 24 volt system runs a panel voltage of 87 VOC. I am running the same disconnect switches you show in this video. I often wonder how I would go in the event of a component failure and DC arcing at 110 volts Vs the higher voltages the grid tie systems work at ?? Would be interesting in hearing your thoughts. Loving you vids 👍
@AndyM...
@AndyM... Жыл бұрын
Thanks Jason, I'm a Firie in FNQ and been to many a DC isolator fire. I think the legislation has changed (in QLD anyway) in that a rooftop isolator is now an option rather than a requirement. I'd like to remove mine at some stage, am hopefully getting additional panels to support off grid EV charging shortly so hope to get rid of it then :)
@joondalupelectricalservice3201
@joondalupelectricalservice3201 Жыл бұрын
Hi Andy, yes your right they are no longer required on NEW installations in Australia however only if certain other criteria is met. In addition an existing installation that has a rooftop isolator is required to retain that roof top isolator as the installation would not meet the installation criteria to enable it to be exempt. Do you guys use a product called PV Stop for (I think its called) for isolating PV power in an emergency.
@AndyM...
@AndyM... Жыл бұрын
@@joondalupelectricalservice3201 Hi Jason, no we don't use PV stop, although it does look pretty effective. Thanks for the info about the isolator, I'll get the installer to maybe just replace it when I do the upgrade, it's been up there for a few years now !
@perezc11
@perezc11 Ай бұрын
Problem is the quality of these cheap isolators, it´s sad to see that the problem is “solved” with the same quality components. It´s sad indeed.
@k-sell4065
@k-sell4065 6 ай бұрын
See I’ve been having people ask me why I don’t mount my solar panels on my roof. Well for one you can’t tell if it’s on fire till it’s too late unless someone sees it in time to inform you. In my opinion it’s a fire hazard being that they are mounted on top of flammable materials such as shingles with tar that burns very hot once ignited along with the wood underneath. So that’s my reason for not mounting solar panels on top of my roof. In my opinion panels should have individual fuses/breakers to prevent such occurrences
@herbertvonsauerkrautunterh2513
@herbertvonsauerkrautunterh2513 Ай бұрын
I only have one roof to isolator. The other strings don't. I will get rid of that one. I need to remove panels anyway as there is an insulation failure. Don't need an isolator on the roof anymore
@OWK000
@OWK000 9 ай бұрын
Roof grid-tie voltages are high and the roof is high, it is indeed dangerous and best left to professionals, but smaller lower volt solar systems built closer to the ground or on RVs can be managed by amatuers that pay attention to what they are doing and get quality components such as MC4 connectors all from the same manufacturer so they match. (MC4 is a weather proof rating, not a size) On the ground all you need is an MC4 to un- plug for power isolation. Ironic that a safety feature like a solar panel isolator would be the weak spot that causes problems.
@user-dc7ud4vr1w
@user-dc7ud4vr1w 16 күн бұрын
They should made it mandatory to install that in a firebox like the lithium batteries on the 787 wouldnt had that much on to the system.
@johnjamce1146
@johnjamce1146 Жыл бұрын
I have had that happen to me on a 1000v 25kw system that thing went up in flame like a Christians tree
@dashley2525
@dashley2525 Жыл бұрын
Does the polarity depend on the LOAD side? I.E. does the polarity depend on the direction of the load ?
@joondalupelectricalservice3201
@joondalupelectricalservice3201 Жыл бұрын
Hey No the load can be on either side.
@dashley2525
@dashley2525 Жыл бұрын
@@joondalupelectricalservice3201 What would you use for an isolator?
@ourkilkennyhomestead2006
@ourkilkennyhomestead2006 Күн бұрын
Begs the question, why no dc circuit breakers in a supposedly professional install?
@Ash-mx2oo
@Ash-mx2oo Жыл бұрын
roof top solar isolators should be checked every two years as a isolator will create to much resistance when water entry and weather conditions. they should not be on the roof they should be under cover, the government rules need to change roof top isolators are dangerous and great more problems then there worth
@TomokoAbe_
@TomokoAbe_ Жыл бұрын
THIS IS ELECTRICITY! There are tons of DIY solar panel videos on youtube making people think this is so easy--not to mention one slip and fall can kill a person or disable them for life. DIY will definitely invalidate any roof warranty, and homeowner's insurance can drop the owner.
@darrenjenkin1281
@darrenjenkin1281 11 ай бұрын
I had 24 solar panels catch fire on the roof of my shed yesterday lucky it didn’t Burn my shed to the ground and everything inside it
@joondalupelectricalservice3201
@joondalupelectricalservice3201 11 ай бұрын
Glad your shed survived, what was the cause
@thethiefonthecross9092
@thethiefonthecross9092 10 ай бұрын
??????
@perezc11
@perezc11 5 ай бұрын
These are the consequences of keep buying and promoting cheap switches that aren´t suitable to withstand thermal requirements on roof top application. Even CEC knows about this situation and problem was not related to breaking capacity but thermal capacity, nevertheless market keep buying the same switch technology of blade contacts that can´t guarantee contact pressure, thus overheating then fire.
@joondalupelectricalservice3201
@joondalupelectricalservice3201 Ай бұрын
Installer error was often the cause also due to not terminating correctly
@commandertim575
@commandertim575 26 күн бұрын
I have been researching this and have found that this is a very common problem world wide. It seems that more often the switch is to blame than installation error. DC voltage is much more prone to arching than AC. I am skeptical about using them all together. Thank you for this public announcement.
Жыл бұрын
My brother... had you ever heard of such thing named tarp? :)) You can use one or two to shut down the solar panels. One laminated hdpe tarp enough to cover the entire array should be way less that $100. Hooks above and some counterweights below. Stop whining about diyers and handymen when you (propose to) unplug mc4 connectors on a potentially loaded array.
@joondalupelectricalservice3201
@joondalupelectricalservice3201 Жыл бұрын
Sounds good, have you seen this product also www.pvstop.com.au
Жыл бұрын
@@joondalupelectricalservice3201 yes but a tarp is a (reusable) tool for servicing. That goo is for 1st responders and firefighters. It's when you want to save the roof. If you just want to replace a switch at noon... just pull the blinders.
@mopikozz
@mopikozz 19 күн бұрын
why not use a DC circuit breaker instead of an isolator
@joondalupelectricalservice3201
@joondalupelectricalservice3201 19 күн бұрын
Good question, it however wouldn’t prevent this type of failure. No rooftop isolator is the best solution.
@mopikozz
@mopikozz 18 күн бұрын
@@joondalupelectricalservice3201 so what is the recommendation? what should we use
@LarryRichelli
@LarryRichelli Жыл бұрын
Weird that you would do a video, blame someone else for setting it up wrong that then not show us how you set it up correctly and instead tell us to get a solar person to do it. Fail!
@bobwhite193
@bobwhite193 Жыл бұрын
I agree with you, until I realize we've overlooked @Joondalup Electrical Services comment about hiring a professional. If we were professionals and not DIY's, we'd already know an alternatively correct method. I believe he's not adding to the potential KZfaq misinformation pool.
@pierrelombaard820
@pierrelombaard820 5 күн бұрын
A isolator is not rated to break current First switch the load off No current flow, isolate A circuit breaker rated to break current at a certain voltage is a different story
@atnstn
@atnstn 11 ай бұрын
DC ISOLATOR SWITHC UP THERE?!? IN BETWEEN THE SOLAR PANELS?!? WHAT THE FLUCK!
@joondalupelectricalservice3201
@joondalupelectricalservice3201 11 ай бұрын
Yep A stupid requirement that is thankfully not required anymore.
@mickeylewis8094
@mickeylewis8094 Жыл бұрын
An electrician knows more about connecting electrical cables better than a solar guy who only knows how to install solar panels in a straight line. You are blaming the installer and not the quality of the equipment and you don't know what is the cause of the fire.
@joondalupelectricalservice3201
@joondalupelectricalservice3201 Жыл бұрын
Hi Sorry I should have explained myself better. By “solar guy” I mean an electrician that is trained and experienced in solar such as myself. In Australia you can not do solar work unless you are a qualified electrician. The cause of the arcing damage was installer error as they failed to terminate the cables correctly as often occurs. It is also possibly a failed isolating switch but I suspect the former to be true.
The Jaw-Dropping Difference Between AC & DC Isolators!
5:39
DAD LEFT HIS OLD SOCKS ON THE COUCH…😱😂
00:24
JULI_PROETO
Рет қаралды 14 МЛН
تجربة أغرب توصيلة شحن ضد القطع تماما
00:56
صدام العزي
Рет қаралды 58 МЛН
Mom's Unique Approach to Teaching Kids Hygiene #shorts
00:16
Fabiosa Stories
Рет қаралды 21 МЛН
ОСКАР vs БАДАБУМЧИК БОЙ!  УВЕЗЛИ на СКОРОЙ!
13:45
Бадабумчик
Рет қаралды 6 МЛН
How Many Solar Panels To Run a Fridge/Freezer?
5:55
Cleversolarpower by Nick
Рет қаралды 659 М.
ABB Aurora and Power One E031 fault, what does it mean and can it be fixed.
2:16
Joondalup Electrical Services
Рет қаралды 540
AMP HOURS EXPLAINED (amp hours vs watt hours)
10:59
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 883 М.
PV Disconnection Devices
11:36
Smart Energy Lab
Рет қаралды 4,9 М.
DIY CAMPER ELECTRICAL MISTAKES (and how to avoid them)
15:40
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 124 М.
Storing Solar Power on my ROOF!!!
17:08
Quint BUILDs
Рет қаралды 4,6 МЛН
SOLAR ISOLATOR WIRING (for a DIY camper van)
6:35
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 59 М.
AC Vs DC Circuit Breakers: The importance of the DC ARC Extinguisher
8:03
Identify equipment in a substation (35 - Electricity Distribution)
10:59
DAD LEFT HIS OLD SOCKS ON THE COUCH…😱😂
00:24
JULI_PROETO
Рет қаралды 14 МЛН