No video

Submersible Shallow Well Pump Install. To be Run by Generator for Camper Hook up.

  Рет қаралды 72,782

H2o Mechanic

H2o Mechanic

Жыл бұрын

H2o-Mechanic Online Store
www.h2o-mechan...
Order Direct from Us.
Links to Common Well System Products
20 Gallon Bladder Tank amzn.to/3AarHhX
40/60 Pressure Switch amzn.to/3QyJMeO
Brass Tank T Manifold Kit
amzn.to/3p89gUY
1/2 Hp 240v Pump 150ft Max Pumping Depth amzn.to/3zGY3iZ
Rubber Tape for Wire
amzn.to/3vSR1GI
Wire Splice Kit amzn.to/3A7U68q
In this video I installed a Shallow Submersible Well Pump to be used for a camper & run off of a generator.
There's dozens of Helpful Plumbing Videos on my Well Pump Q&A Playlist, So go check it out!
Comments are Always Live!!! Here to answer any questions you may have.
Show Support by Subscribing if you Learned Something New.
Best Water Well Plumber on KZfaq!!!
Donations are appreciated!
Hwdracing@gmail.com. - PayPal
Philip-Hensley-3 - Venmo
❤️ Super Thanks - KZfaq
Music Credit: Jason Shaw
Song: Pioneers
Soure: Audionautix.com
#wellwater #plumbing #wellpump #submersiblewaterpump #pressuretank #pressureswitch #plumber #tradesman #homesteadadvice

Пікірлер: 149
@parker1ray
@parker1ray Жыл бұрын
I have installed thousands of these systems in the 90's and injectors, chemical dispensers, iron filters, water softeners, UV filters and a ton of other systems!
@andrewrivera4029
@andrewrivera4029 Жыл бұрын
Great video, most good techs are not afraid of giving out expert instructions because they sell their craftsmanship and most importantly the customer trusts them. Any tech who can explain what they’re doing they’ll usually get my business and I will not look for someone else.
@jmhall918
@jmhall918 Жыл бұрын
Great video. Would love to see some more closeups of your plumbing connections and wiring once finished. But I'm loving the channel. Lots of good stuff here. Thanks.
@Evan-bc6nb
@Evan-bc6nb Жыл бұрын
I really like your roller that you use to install. I've done hundreds of these and that one tool would have made life a lot easier
@pauledelen6254
@pauledelen6254 11 ай бұрын
I believe this will end up more of a question than a comment. I have somewhat of a unique situation compared to most of your well/shallow well videos I have watched. And thank you very much for putting out such practical DIY (some/most) videos, I know some situations require professional help. My situation is this, I live on a small river lake in South Central Texas. I have an above ground 3/4hp pump running our 9 zone yard irrigation system that was professionally designed and install by me and a couple friends over 30 yrs ago and has run flawlessly for 30+ yrs. But for that last 6 months or so my above ground pump started leaking at a gasket in the pump. I was given a used operating (Goulds 10EJ15412) 1&1/2hp submersible pump that was replaced in a deep well where my son-in-las worked that I now want to replace the above ground pump with. It will sit about 4-5' below the lake water surface level to prevent sucking any air when boat waves come by and pump up through pump shed and pressure tank then uphill about 25' rise at a 45 degree angle 200' up the length of our yard feeding the 9 zones and 4 sporadic faucets. It is not an option to change any of the 1 1/2" piping, some of it goes through concrete seawall. Since the 1 1/2hp submersible pump has what looks like a 1" or 1 1/4" threaded output, - will I loose much pressure and/or volume plumbing this pump to an irrigation system that has all main lines are 1 1/2"? Right now the above ground pump will easily run 1 zone and 4 hoses with sprinklers watering the edges and areas the irrigation system do not get. At the zones the pvc drops to 1" and then to 3/4" and finally 1/2" usually at the last sprinkler head. Basically leaving the pump at it's 1" or 1 1/4" output then immediately transitioning back up to 1&1/2" prior to the pressure tank and cutoff switch (which will be located in the pump shed). - there is an external foot valve on the pump I was given, do I need an external foot valve for this type application where I will be able to easily pull/service the pump at any time? I saw on one of your videos you recommend this but I believe you said only on a deep well installation. - I am hoping my application will allow the pump to run constantly while the irrigation and/or faucets are running and not cycle the pump on and off, any ideas? Are those cutoff switches adjustable to keep the pump running when needed? Thanks for taking the time to put out your videos, I have found them packed full of knowledge and very useful. Paul in Texas
@alabama24fan
@alabama24fan Жыл бұрын
Always a good videos from Phil, with his videos, I was able to replace all components of my deep well and now have a running well! He even replied To my question when my new install did not work, diagnosed it was a broken wire, replaced the wire and it started working. Keep the videos coming Phil.
@h2omechanic
@h2omechanic Жыл бұрын
Thanks Mr. Williams!
@ThatGuyFromArizona
@ThatGuyFromArizona Жыл бұрын
Thank you for the time you put into these videos. It is amazing to me how many people use pump pliers backwards... This guy uses them properly everytime. 😀
@wolphin732
@wolphin732 Жыл бұрын
4:42: one thing you don't comment about the rubber tape... stretch it a bit, and it self-sticks and helps seal better to keep out moisture. I used it for sealing connectors up a tower, but as rubber tape is UV sensitive... needed to cover it with electrical.
@ST-ty9ic
@ST-ty9ic 3 ай бұрын
This video was super helpful for me. Thank you!
@esunetdude
@esunetdude Жыл бұрын
A topic I never hear you mention is the size of the storage tank. In instances where there is space and the well produces enough water, I understand it is better to use a larger tank versus the small blue and white tanks. From what I read, the benefit is less startup on the pump. That means less stress on the pump (longer life), and less instances of needing startup current.
@kendallreeves5665
@kendallreeves5665 9 ай бұрын
When using stranded wire under a screw put a left hand twist in it to prevent the wire from being untwisted.
@curtw8827
@curtw8827 Ай бұрын
I've watched many of your videos, enjoyed them all. Why not put the wire spool at the other end and pull the wire back towards the pump? Then it will never be short.
@wdxwm300
@wdxwm300 20 күн бұрын
Always interesting to watch your video`s Our wellman in this area of Pa puts tank in ground its fiberglass with bladder inside and puts the switch with gauge inside the well above the pitiless adapter. So no freezing here in the North
@ST-ty9ic
@ST-ty9ic 3 ай бұрын
Can you make another video with how to open and close the season with this kind of setup? I live Canada where pipes freeze....so I can't have any water in pipes or pressure tank ...
@Djkyle65
@Djkyle65 Жыл бұрын
Great video! Wish i could find someone with your skill set and honesty down here in Texas.
@googacct
@googacct Жыл бұрын
For a situation where you want to use a generator with a well, is it worth adding some kind of a soft start circuit to cut down on the starting amps?
@Catdog9205
@Catdog9205 11 ай бұрын
I enjoy the videos it's guy stuff and I like it. They are never the same always new obstacles to over come. Keep them coming cause I enjoy everyone of them.
@totalpkg6912
@totalpkg6912 Жыл бұрын
excellent narration
@euonymus1980
@euonymus1980 Жыл бұрын
Well done Phillip!
@philoleary7808
@philoleary7808 Жыл бұрын
Enjoy your teaching us, as for myself tho i cant hear you clearly over the music.
@itselliehybrid9398
@itselliehybrid9398 Жыл бұрын
Wow. Don’t ever come an work in Australia, Franklin would give no warranty on that installation. We need to use rubber cable and double heat shrinks.
@Utubegofukurself
@Utubegofukurself 3 ай бұрын
Pro top: Never cutt towards yourself, always cutt towards a buddy!
@johnstreet797
@johnstreet797 10 ай бұрын
Great content as usual, but your background music is distracting.
@screenw0rld
@screenw0rld Жыл бұрын
2023 hope this channel grow more 🦾
@kiweekeith
@kiweekeith Жыл бұрын
Greetings from New Zealand .... Totally on the Other Side of the World ...... :-) :-) :-) I just love All of your vidclip .... But Every Time I am just so dissapointed .... You go thru' the Whole Thing, but we NEVER see the result and see the WATER gushing out.... :-) :-) :-) This is in MOST of your vidclips .... The whole point of you doing ALL that Work is to give the customer water and we would Also like a taste of it too ..... :-) :-) :-) .... Best to You, Yours and All others, Cheers from ChCh, NZ
@WJCTechyman
@WJCTechyman 13 күн бұрын
I guess it really depends on the area, but I would think even for a temporary setup I would run conduit from the well into the pressure switch and use SOOW for the power pigtail and plug with water tight glands on all connections. A way of doing it without the conduit would be using the appropriate gland on the three wire zip cord from the pump. I don't know if there are pressure limit switches that are also water tight or whether that's needed but just something I would personally feel comfortable using.
@Keith_Mikell
@Keith_Mikell Жыл бұрын
Did your dad teach you how to teach people? You are one hell of a good teacher. They cant pay teachers 100's of k that are as good as you. Damn.
@h2omechanic
@h2omechanic Жыл бұрын
My dad taught me everything I know. But KZfaq is what made me realize how good I was at teaching. I teach In the same way I am able to learn (having Adhd) seems like most can connect better with my methods of teaching. Plus I enjoy it. I treat the camera as if I was training an employee
@pl747
@pl747 Ай бұрын
I always use a pipe coupler and then an elbow or a tee with on side plugged on top so the pipe will hang straight down. I noticed that one is cocked some. On a well like a 100 ft or less I use a 120 volt pump. It is much easier to hook to a generator and some generators don't even have 240 volts. But you will need around a 3000 wat generator to handle the current surge when the pump starts unless it's one of the high priced soft start pumps.
@bcbministries70x7
@bcbministries70x7 Жыл бұрын
What are those yellow handled wire strippers that you use?
@YamahaC7SRG
@YamahaC7SRG Жыл бұрын
Great video, yet again! Your videos are always helpful!!
@Andywmm9
@Andywmm9 Жыл бұрын
Looks great, but since it is outdoors that wire should be run in flexible conduit.
@maintenanceman1015
@maintenanceman1015 Жыл бұрын
At 9:35 can see the house that`s a fixer upper ,but it`s home .
@crabmansteve6844
@crabmansteve6844 Жыл бұрын
Have you guys ever used marine epoxy lined heat shrink? I prefer that heat shrink, but you do such a damn thorough job with that tape I bet you never have an issue out of it. I prefer epoxy heat shrink just because it looks cleaner.
@edsel6818
@edsel6818 Жыл бұрын
I wish you coulda tried it, it woulda be really REALLY NICE TO FIRE IT UP FOR THE FIRST TIME. ALSO YOU MUST BE IN A HOT WARM TEMPURATURE STATE, UNLIKE HERE IN SD, NEBR, COLO, KANSAS, MONTANA, ALL OF OUR SUBMURSABLES AND 80 GALLON TANKS ARE IN A 6' OR 8' TRENCH UNDERGROUND COVERED UP, IT FREEZES HERE ALL THE TIME 🥶🥶🥶🥶😳🤯😵😱🥶🥶🥶 GREAT JOB!! 😉👍
@h2omechanic
@h2omechanic Жыл бұрын
Yes it's very humid here. & only see about 25⁰ on our cold winter snaps
@Justme-jt1ef
@Justme-jt1ef 9 ай бұрын
5:52 I knew you was gonna talk about zip ties
@TCooper304
@TCooper304 Жыл бұрын
I am not sure if you answered this in another video but I would love to see a simple wiring schematic/explanation for what wire goes where when you connect the three pump wires to the yellow submersible wire and then connections topside. Do different pumps (more or less horsepower) require different wire gauges? I assume you run underground feeder to the connections topside of the well? Thanks man, you are putting out great content.
@h2omechanic
@h2omechanic Жыл бұрын
A typical 2 wire pump is simple to wire. Connect the green ground wire first, & the other wire can go any which way. A 3 wire pump is the same, except you must hook up the Yellow starter wire to the yellow in the control box. A few other install videos go over wiring ect. They are the longer videos
@grogoncom
@grogoncom Жыл бұрын
@@h2omechanic I find that going over the "small details" even for a avid watcher is OK. for instance wire size is dependent on pump size and distance of run!!!! even why a 2 wire pump is used, even why do you call it a 2 wire when there are three. whats the difference? for instance i used a 4 wire due to me wanting the "capacitor" in my home as that in my belief is the most common failure point. why in this video do you not use "brass fittings"? the grey fittings "the elbow" are the cheapest weakest things in my local hardware store!!!! now if that is a different "schedule" fitting then please comment on that. thanks for you vids though I do enjoy them. I feel sorry for these guys spending what they do for so little water though. I have a flowing well and the pump puts out a stream 15 ft vertically. (red lion 12gpm, 1/2hp.)and I believe 62gpm,108 ft deep
@jamesmckee-8558
@jamesmckee-8558 9 ай бұрын
Thanks!
@Dirtybird37
@Dirtybird37 Жыл бұрын
Great video and content 👌
@southfloridadriller815
@southfloridadriller815 9 ай бұрын
Your videos are great! Could you suggest a water depth meter?
@billryan8721
@billryan8721 Жыл бұрын
Thanks for the great videos. When and why are check valves installed on the down pipe sometimes?
@Nidkidful
@Nidkidful 10 ай бұрын
Keeps the down pipe from emptying out, meaning you don't end up with a bunch of "air" in the line, if you end up below the vapor pressure of water.
@johngraves2968
@johngraves2968 7 күн бұрын
A couple questions. Don't shoot the messenger. #1. Should the well have been shocked by chlorine. #2. Should the well have been bonded.#6 wire.(grounding rod) Since the well is not steel, A PERSON doesn't want a lightening bolt to Fry the pump. #3 should a disconnect switch have been installed at pump, maybe screwed to a wood stake, near the well. #4. How would a person release the water, back down into the well, if there was a chance of freezing temperatures, to prevent the pvc from cracking. Now the patch cord was only 10 feet or so. The owner was also powering a camper and The patch cord could be changed to 75 feet long next to camper. We all know that temporary sometimes stretch a little bit. I'm just
@MaMa-qh4dy
@MaMa-qh4dy Жыл бұрын
Very thorough! Thank you.
@johncuervo3019
@johncuervo3019 Жыл бұрын
Been seeing signs for your company around crowders mountain
@h2omechanic
@h2omechanic Жыл бұрын
Doubtful. Someone in n.c. named there company Mike Hens.. well drillin Very similar to our business name He travels 4 states. We stick to va/nc & only 70mile radius
@jeromewhelan6723
@jeromewhelan6723 Жыл бұрын
Good video, but I was disappointed when you got to the end and did not check out the performance using a generator you provided.
@jeff95050
@jeff95050 9 ай бұрын
I looked for but missed any others asking this, but I am curious about: A) Check Valve? I didn't see one installed. Necessary? Maybe built-in to the pump and not needed on shallow well? B) Did you set the pump directly on the bottom of the bore? The casing was 80ft deep and I thought I saw you drop the pump to 80ft. Will sediment be a problem over time causing turbidity?
@thaynehenderson9426
@thaynehenderson9426 Жыл бұрын
How could a guy get a hold of you as I have a few questions about my water system in my home. I have a 400gal fresh water holding tank, that runs to a 1/2hp non submersible pump with a flotec tank. I have set everything up the way you have shown in previous videos on your channel but I'm still encountering an issue. If I could shoot you an email that would be sweet! Happy holidays to you and your family! Thank you for the wonderful / educational content you put out!
@h2omechanic
@h2omechanic Жыл бұрын
Hwdracing@gmail.com
@sauravsanyal4397
@sauravsanyal4397 4 ай бұрын
Saving penni for a adapter
@user-tq5ve5sg6y
@user-tq5ve5sg6y Жыл бұрын
Is there any well pump that will go down a 2 inch casing a 188 feet and supply water well 360 feet 8 gallons per minute
@danielbarbour3501
@danielbarbour3501 Жыл бұрын
How accurate is the well tag? Specifically you state that you want to keep the pump inside the casing, the tag says the casing is at 80 feet and you indicated you were going to put the pump 'at 80 feet'. If there is any inaccuracy in your measurement (on the long side) or their measurement (on the short side) then the pump will be outside the casing. Would it not be better to set the pump at 75 feet (something close to, but not AT, the end of the casing)? Also - I do not recall seeing you 'shock' this well before inserting the pump whereas I've seen that done in another video, was that not required for 'this' setup or was it done prior to the start of the video?
@ashleymuse3789
@ashleymuse3789 10 ай бұрын
Do you think you could run a well pump off a solar panel system
@hemi5365
@hemi5365 9 ай бұрын
Thank you for sharing these videos. I enjoy watching you work, very professional. I am wondering why you don't use any UNIONS in your piping? I have used them in many applications. When having to make any repairs, like because of broken pipes or whatever it makes disassembly easier and I don't have to cut out a lot of good pipe. For instance, if I had to change the bladder tank as you have it installed, I could disconnect at the union.
@parker1ray
@parker1ray Жыл бұрын
I don't see any primer! Is this a new type of glue that doesn't require primer?
@jake-mv5oi
@jake-mv5oi Жыл бұрын
Yes.
@dusttoyou4550
@dusttoyou4550 Жыл бұрын
Recently found your channel and did subscribe. Great content! On one of your previous videos the subject was the PVC pump sleeve to protect the pump motor. When I replaced my shallow well submergible , about 6 months ago, I found on Franklin's site their advising using these PVC sleeves particularly on larger diameter wells to insure pump motor cooling. I have a 85 foot 24" curbed well and it had gone through 3 pumps in 15 years, due to motor failure. I am convinced that had I installed the PVC sleeve on pump number one, I would still be using pump number one. Was wondering why you did not include the PVC sleeve on this 10" shallow well?
@h2omechanic
@h2omechanic Жыл бұрын
Because this pump is set at 80ft. Water enters the well Below the motor, thus cold water will pass by the motor to cool it. A sleeve will help every pump. Bur there are situations that need them more than others
@williamhanna5224
@williamhanna5224 10 ай бұрын
Awesome video Great work !
@mathdj01
@mathdj01 Жыл бұрын
Do you have a Franklin Aid document on 2-wire motors and generator use and effects to the Franklin BIAC switch? Its not in the AIM manual. The Franklin AID is an old monthly doc, Franklin published in the past.
@JoseOrtiz-zb7gq
@JoseOrtiz-zb7gq Жыл бұрын
Awesome
@LenStrozinski
@LenStrozinski 3 ай бұрын
I have worked with 230V motors in the past and know I can change the rotation direction of the motor by switching 2 of the wires. Is motor rotation a concern for well pumps?
@adf360
@adf360 9 ай бұрын
I'm curious about the white silicone looking material used to seal the wire where it enters the well. It appears oddly supple, just screams of quality, is it some 3M product?
@jeff-el3hr
@jeff-el3hr 8 ай бұрын
How do you keep the line from freezing?
@patricklasiter5665
@patricklasiter5665 Жыл бұрын
do you install well pump
@guruguy6800
@guruguy6800 Жыл бұрын
Wish you would have shown how to wire the pressure switch
@h2omechanic
@h2omechanic Жыл бұрын
I have videos on the pressure switch on my Well Pump Q&A Playlist.
@paulcoulter7181
@paulcoulter7181 Жыл бұрын
H2O how do y’all know how much water a well will make?
@davidstreling3690
@davidstreling3690 7 ай бұрын
you always show putting a bad of shock in the well but not this time is it because it is a shallow well
@Mr.JayOutdoors
@Mr.JayOutdoors 22 күн бұрын
Could you give information on the wire you use. Gauge, volt
@stevenstone8875
@stevenstone8875 2 ай бұрын
I couldn’t help but notice you didn’t sanitize as well prior to installing the pump. When is that required?
@larrytheplumber9851
@larrytheplumber9851 2 ай бұрын
4:17 Bush hog coming up behind you
@thepubliceye
@thepubliceye Жыл бұрын
Won't that freeze in the winter?
@HangNguyen-ty7zv
@HangNguyen-ty7zv 8 ай бұрын
Bro what is black pipe?
@MusafirsSoul
@MusafirsSoul Ай бұрын
Can you use solar system instead of generator in this setup! If yes what size? Thanks
@stephenhorton2184
@stephenhorton2184 Жыл бұрын
Thank You
@chrisfulk5088
@chrisfulk5088 Ай бұрын
I got a question when hookin wire to the pump how u kno which colored wire is which
@bcbministries70x7
@bcbministries70x7 Жыл бұрын
Thank you for this video. Speaks right into my situation. My off grid well produces 10gpm. I have a 23gpm submersible pump. Is there a way for the two to work together without running the water dry? Thanks in advance!
@h2omechanic
@h2omechanic Жыл бұрын
If it ran dry, it mostly like wouldn't hurt it. But yes, you could install a low pressure cut off switch.
@bcbministries70x7
@bcbministries70x7 Жыл бұрын
@@h2omechanic Thank you! Much appreciated.
@abm2958
@abm2958 Жыл бұрын
You can also add a ball valve in the line before the tank and switch to throttle the output of the pump. A Dole valve would also do this but costs more and isn't adjustable.
@chasecundiff8268
@chasecundiff8268 10 ай бұрын
Thankyou for having this channel! Ive never had to hook up a well before, but I now am in the process and I’m learning. Trying to learn from reading online and watching your videos. I just got a well drilled to hook up to my mobile home. The well is 100ft, 15 gpm, 8ft static water level. Should I be concerned that the static level is so high?
@chasecundiff8268
@chasecundiff8268 10 ай бұрын
Also, (not being critical at all) just curious why you didn’t install a check valve before the pressure tank.
@cychael2011
@cychael2011 Жыл бұрын
Are sure pvc will stand the winter freezing temperature?
@h2omechanic
@h2omechanic Жыл бұрын
No it will no. Everything must be covered up or drained out by winter.
@keithjarrett5350
@keithjarrett5350 Жыл бұрын
How far away from the well can the home be? When it is piped with pvc. Could it pump 200-300 feet and give adequate volume and pressure for a small house?
@abm2958
@abm2958 Жыл бұрын
1" line would easily carry that distance.
@FescueFreak
@FescueFreak Жыл бұрын
Is POP-off valve necessary? Mine is starting to leak can it be removed or needs to be replaced?
@h2omechanic
@h2omechanic Жыл бұрын
Not necessary at all. Only on big systems 2hp+. Remove it and plug it.
@scott5747
@scott5747 9 күн бұрын
Are using 1" or 1 1/4" tubing?
@exportedafrican
@exportedafrican Жыл бұрын
Ever considered using pex for the above ground sections?
@wolphin732
@wolphin732 Жыл бұрын
Is there any reason you don't use a ratcheting crimper? A ratcheting one makes sure the connectors are all a uniform compression level, to make sure a good contact is made.
@dennisbeck5467
@dennisbeck5467 11 ай бұрын
What’s your thoughts on a cycle stop valve?
@h2omechanic
@h2omechanic 11 ай бұрын
Only necessary if its a Irrigation well for a sprinkler system. For residential use, it keeps the pump under full load at all times . You may get 70psi in the home, but the pump would be under 150-170psi of load (depending on the pump size) While it's better for the electric motor, the pump stack/impellers & bearings and seeing unnecessary abuse.
@dennisbeck5467
@dennisbeck5467 11 ай бұрын
@@h2omechanic thank you for your reply it was great to get your thoughts on it
@tszymk77
@tszymk77 Жыл бұрын
Where can I as a consumer buy 600 feet of pipe and 600 feet of wires? I've only seen them sold in 300 foot lengths (except Menards but for some reason they won't ship to my NC address). Also what PSI rating should the pipe be at 600 feet? I saw blue 1" poly pipe rated at 250 psi. Thanks for all your great videos!
@Henning_S.
@Henning_S. Жыл бұрын
600 feet is roughly 200 meters, so the static pressure is 20 bar, i don't know how much psi that is. But you need more than the static pressure if you want the water to still have some usable pressure when it exits the well, so I would suggest min 25 bar, if possible a little more to be on the safe side. You can easily connect two 300 feet pipes, you can even choose pipes with different pressure ratings, the upper pipe just needs a pressure rating of min 15 bar (100 meters higher, therefore 10 bar less pressure)
@tszymk77
@tszymk77 Жыл бұрын
@@Henning_S. In our Burgerland the formula for pipe pressure is (pipe in feet X .433) + home water pressure in PSI. So for my application if the pump was at 600 feet deep it would be (600 X .433) + 50 = 310 PSI. The thing is (and part of the reason for my original post) that the strongest poly pipe I've seen anywhere is rated for 250 PSI. I'm guessing that for such a deep application this is what people actually use and kinda hope they don't deplete the well all the way down and even if they do I think the 250 PSI pipe will hold up to 310 PSI of pressure (yes, it's pushing it beyond limits etc). I also thought about joining two pipes like you said, I'm concerned about the joint holding up but if it was a good brass fitting and really good clamps then I think it would be fine. Ideally I'd like to buy one length of pipe but I've only seen 500 ft long (too short) or 1500 ft long (too much for me).
@Henning_S.
@Henning_S. Жыл бұрын
@@tszymk77 I'm pretty sure the 250psi pipe will work, in the bottom of the well where the highest pressure is, it is always cold and therefore the plastic never gets softened by heat. The rated pressure is probably for relatively high temperature, so it doesn't fail when it gets heated by the sun or even hot water in case it is also rated for hot water. The pressure at the joint between the two pipes is much lower than the pressure at the connection between the lower pipe and the pump, so I wouldn't worry about the connection between the two pipes. If you choose a 500 foot pipe at the pump and a 100 foot pipe at the top, the pressure at the joint is below 100psi...
@tszymk77
@tszymk77 Жыл бұрын
@@Henning_S. Yes, very good points. Thank you for your help.
@briantheguy1
@briantheguy1 Жыл бұрын
Did you replace that blue well seal plug with some type of vent?
@sh839c
@sh839c Жыл бұрын
Excellent video and really good music
@briankirkland249
@briankirkland249 Жыл бұрын
Got to well over 200 ft deep was clear now just muddy what do you think's wrong
@h2omechanic
@h2omechanic Жыл бұрын
Typically heavy rain fall will cause a well to get muddy water. (This should not happen) if yours is muddy after heavy rains, then you need to look into "Well Liners" . Your Casing is not deep enough, or your first water vein is connected to surface water, the liner installation will block out that upper vein from mixing in muddy water with the deep water veins that are clean/clear water. I have Vids on liners.
@paulnorman2652
@paulnorman2652 Жыл бұрын
Is there a reason you use stranded wire on well pumps, and not solid core wire?
@nkr3637
@nkr3637 3 ай бұрын
Showing how you wired the switch to the receptible plug is the only reason I was here. Nothing on that.
@galleguitos85
@galleguitos85 8 ай бұрын
do you know whats a good size generator to run does well pump by chance ?
@h2omechanic
@h2omechanic 8 ай бұрын
5500watt 240v generator is typically the minimum. Anything smaller can't handle the startup amps
@davidcottle6099
@davidcottle6099 Жыл бұрын
does a bladder tank ever need sanitizing?
@mnblkjh6757
@mnblkjh6757 10 ай бұрын
👍🙂
@rick_3.50
@rick_3.50 Жыл бұрын
COST?
@mr.crazyboycomedy4810
@mr.crazyboycomedy4810 Жыл бұрын
So if the well is 50m how meters of the cable and the pipe needed?
@h2omechanic
@h2omechanic Жыл бұрын
It really depends on what level the water is at in the well. But roughly 35-45 meters of pipe would be needed.
@BrentBerghermPhotography
@BrentBerghermPhotography Жыл бұрын
I’ve got a 1/2 hp pump (240V) in a shallow well. But it can’t get more than 25psi. What should I look at first? I Would love to set it at 30/50 like the pressure switch is made for but I’ve had to decrease the pressure in the tank and reset the switch so it operates properly (proper cut on/off) but I want the higher psi. Do I need a 3/4 hp pump to get greater pressure? Something else?
@h2omechanic
@h2omechanic Жыл бұрын
If its a submersible pump it should build 60psi , unless there's a leak somewhere down the drop pipe. Turn off the pump breaker and then see if the pressure drops to 0. That'll tell you if there's a leak
@BrentBerghermPhotography
@BrentBerghermPhotography Жыл бұрын
@@h2omechanic Thank you! It is submersible. I'm pretty sure it has a leak, but I'll test with your recommended method to be absolutely certain.
@Steve-sg3uz
@Steve-sg3uz Жыл бұрын
Is it true that if you use too much pipe paste you will be tasting it in the water for a long time?
@h2omechanic
@h2omechanic Жыл бұрын
I only see that happen if the filter traps the pipe dope & all the water runs thru it. Customers need to replace the first filter after 5 days of use, then it'll be fine. Rare occurrence
@kevintipple9301
@kevintipple9301 Жыл бұрын
there is no information on galvanized water tanks non bladder how to set them up and how to set up pressure in them ????????
@h2omechanic
@h2omechanic Жыл бұрын
Drain them completely dry & then turn on the pump with all exiting valves closed. This will trap air in the upper portion. Once it's full, you can then add air to the tank for a few minutes with a compressor. That should get you running better. Galvanized tanks have air bleeders if it gets too much air it should vent off. (Not to say your vent valve is faulty)
@MarsMan1
@MarsMan1 Жыл бұрын
Did you forget the glue or is that all in one (Primer & Glue)?
@h2omechanic
@h2omechanic Жыл бұрын
It's all in one
@stanleybilliot2020
@stanleybilliot2020 Жыл бұрын
Can I put a 40/60 pressure switch on a tank that does not have a bladder
@h2omechanic
@h2omechanic Жыл бұрын
Yes.
@stanleybilliot2020
@stanleybilliot2020 Жыл бұрын
@@h2omechanic thanks
@davidmark805
@davidmark805 Жыл бұрын
That must be one big ass generator to start up and run a 240V 1/2 h.p. submersible.
@h2omechanic
@h2omechanic Жыл бұрын
5500watt minimum to run a pump successfully
@pierreletourneau722
@pierreletourneau722 7 ай бұрын
I have a 240 V, 1 1/2 h.p. submersible pump and when the power is off, I have no problem with a 8000 watts generator. At first I had a 4000 watts generator but I had to disconnect everything to use the pump.
@bradhanson4803
@bradhanson4803 Жыл бұрын
I work at a well drilling company in ct we use steel casing pipe how come you don't steel more costly
@h2omechanic
@h2omechanic Жыл бұрын
It's basically the region your in requires steel casing. When we run into bad rock formations, we pull out the pvc & go back with metal. Just different laws in your state.
@bradhanson4803
@bradhanson4803 Жыл бұрын
Thanks for the reply
@genoortega1171
@genoortega1171 10 ай бұрын
👏👏👏👏👏👍🏽
@RussellMinor-v2h
@RussellMinor-v2h 14 күн бұрын
Use zip ties easier
Replacing a 1970s Jet Pump with a Modern Submersible Well Pump
15:14
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 210 МЛН
Look at two different videos 😁 @karina-kola
00:11
Andrey Grechka
Рет қаралды 8 МЛН
UNO!
00:18
БРУНО
Рет қаралды 4,2 МЛН
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 34 МЛН
I Dug A Shallow Well For The House... (From Start To Finish!)
10:18
Red Poppy Ranch
Рет қаралды 112 М.
Submersible Pump Installation. Replacing a Bad Pump for $300
27:05
H2o Mechanic
Рет қаралды 80 М.
How to INSTALL YOUR OWN WELL with a Sledge Hammer for FREE OFF GRID WATER
7:53
DIY DEEP WELL HAND PUMP INSTALLATION + RESULTS
23:39
Martin Johnson - Off Grid Living
Рет қаралды 550 М.
I dug a 40 foot well in my backyard
15:24
Bad Homeowner
Рет қаралды 688 М.
Deep Submersible Well Pump Installation. Educational Guide
41:08
H2o Mechanic
Рет қаралды 442 М.
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 210 МЛН