Suitable Wiring Methods [110.8], 2023 NEC, (6min:45sec)

  Рет қаралды 8,739

MikeHoltNEC

MikeHoltNEC

5 ай бұрын

What exactly is a “suitable” wiring method? To learn more about how to interpret NEC section 110.8, take the time to read the attached text and watch the video where Mike and the team explain what is meant by a suitable wiring method.
This video is extracted from Mike Holt's 2023 Understanding the NEC Complete Video Library, for more information visit www.MikeHolt.com/Code ​ or call 888.632.2633.
For decades, Mike Holt Enterprises has been the go-to resource for electrical training. Our mission is to empower electrical professionals like you to master the Code, excel in exams📝, and elevate your electrical knowledge..
👉 Explore Exam Preparation Tips and Training at www.MikeHolt.com/examprep
🚀 Find Electrical CEU courses at www.MikeHolt.com/CEU
⬆️ Level Up your school's electrical training program with Mike Holt Enterprises at www.MikeHolt.com/Instructors
Whether you're gearing up for an exam or looking to enhance your electrical knowledge, we've got you covered. We offer instructor and curriculum support, a variety of continuing education options, free videos, graphics, and a wealth of valuable resources.
📌 Stay Connected:
/ mikeholtenterprises
/ mikeholtenterprises
/ mike-holt-enterprises-inc
🔗 www.mikeholt.com
✅ Don't miss out on the latest updates and exclusive content. Subscribe to this channel now - Click here to subscribe: / @mikeholtnec .

Пікірлер: 12
@Sparky-ww5re
@Sparky-ww5re 4 ай бұрын
Fun fact: In some 1870s - 1910s homes that originally used gas lighting, the gas piping was re-purposed as conduit for running conductors to the new fangled electric light, I don't know that this practice was ever a recognized wiring method but it certainly made for a less expensive and more seamless transition to electricity as it became increasingly available in major cities and suburbs. Metal conduit with threaded fittings was born out of black iron pipe used for gas lighting.
@KleinGuyJon
@KleinGuyJon 4 ай бұрын
Your absolutely right. Here in NYC, I've lived in these older prewar homes that had gas lines used for gas lighting and the gas pipes were utilized for conduit for the electrical wiring throughout the house which was really clever and i bet it was costly.
@emer2394
@emer2394 4 ай бұрын
That’s when the plumber say I can do your electrical too.
@moosepasshippie
@moosepasshippie 4 ай бұрын
There is a building on base that has a HEMP Shield. The people installing it used pvc plumbing 90s and the C.O.E. accepted it. Watching them pull wire was comical.
@benfowler2127
@benfowler2127 4 ай бұрын
I’m so glad he brought up 110.12 😂
@41keystar14
@41keystar14 4 ай бұрын
Just purchased your electrical Exam Preparation. Been along time coming to get my E2. Been set back 4 full years on registration. Done twice the requirement. Some say a bird in the hand is worth two in the bush what BS. You’ve gotta have two birds in the hand in this industry. Have been struggling to pass the test hopefully your exam prep makes the difference for me. Contractors can be such system abusers, it pains me to give them the satisfaction and not be able to pass.
@41keystar14
@41keystar14 4 ай бұрын
Currently I’ve gotten a 60, 65, and a 68.7 the last time I missed it by one question. At least I haven’t ever blown it entirely just a little rough around the edges. Every time I am very well rounded just seem to fall for all the traps
@MikeHoltNEC
@MikeHoltNEC 4 ай бұрын
Answer every question in the book and watch every second of the videos. You'll smoke the exam the next time. No short-cuts!@@41keystar14
@charlestaylor3544
@charlestaylor3544 4 ай бұрын
Those pipes running across under the panels look sketchy to me. Are they encroaching on electrical space?
@MikeHoltNEC
@MikeHoltNEC 4 ай бұрын
No, read 110.26
@joeerskine3920
@joeerskine3920 2 ай бұрын
Proper power application: nuclear power plant for every device!
@ekawakakonahi1174
@ekawakakonahi1174 4 ай бұрын
That box on the ground only contained a 1/4” poly tube for the fountains bubbler. Bunch of snotty whiners!🤣
Branch Circuit, Multiwire, NEC 2020 - [210.4], (19min:38sec)
19:38
MikeHoltNEC
Рет қаралды 234 М.
Auxiliary Grounding Electrodes [250.54], NEC 2023, (10min:54sec)
11:14
Хотите поиграть в такую?😄
00:16
МЯТНАЯ ФАНТА
Рет қаралды 3,3 МЛН
Double Stacked Pizza @Lionfield @ChefRush
00:33
albert_cancook
Рет қаралды 31 МЛН
路飞被小孩吓到了#海贼王#路飞
00:41
路飞与唐舞桐
Рет қаралды 74 МЛН
AFCIs, Clearing Series and Parallel Arcing Fault
17:47
MikeHoltNEC
Рет қаралды 6 М.
Grounding Versus Bonding (26min:26sec)
26:26
MikeHoltNEC
Рет қаралды 246 М.
Kitchen islands and peninsulas in the 2023 National Electrical Code
17:14
Grounding, Objectionable Current [250.6, 2020 NEC]
18:15
MikeHoltNEC
Рет қаралды 23 М.
How To Use The NEC, NEC 2020, (29min:15sec)
29:15
MikeHoltNEC
Рет қаралды 157 М.
Neutral-to-Earth Voltage (NEV), NEC 2020, (44min:40sec)
44:40
MikeHoltNEC
Рет қаралды 216 М.
How Do You Bend a 90 in Conduit?
9:27
Electrician U
Рет қаралды 110 М.
Coordination, Overcurrent Protective Devices
14:23
MikeHoltNEC
Рет қаралды 8 М.
Хотите поиграть в такую?😄
00:16
МЯТНАЯ ФАНТА
Рет қаралды 3,3 МЛН