The 5 Hydraulic Troubleshooting Tools You Don't Have

  Рет қаралды 25,414

GPM Hydraulic Consulting Inc

GPM Hydraulic Consulting Inc

Күн бұрын

These 5 inexpensive tools will pay for themselves the very first time you find a hydraulic problem with them! Visit our website http:gpmhydraulic.com to learn about our two part training process.

Пікірлер: 13
@JohnnyLawBMC
@JohnnyLawBMC Жыл бұрын
Great info. What a great demonstration of the variable displacement pump. You did such a great job. Thank you
@michaelcostello6991
@michaelcostello6991 5 жыл бұрын
Thanks. Really interesting info
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
Thanks, Michael!
@dgb5820
@dgb5820 6 жыл бұрын
Great video Sir
@Gpmhydraulic
@Gpmhydraulic 6 жыл бұрын
DGB Thanks!
@obrianfelix
@obrianfelix 6 жыл бұрын
EXCELLENT WELL DETAILED EXPLANATION
@Gpmhydraulic
@Gpmhydraulic 6 жыл бұрын
Thank you for your kind comment, Felix!
@luiseduardoalvarezcontrera9163
@luiseduardoalvarezcontrera9163 7 жыл бұрын
Bien.
@impactodelsurenterprise2440
@impactodelsurenterprise2440 3 жыл бұрын
How do you prevent pressure shock when measuring pressure upstream?
@JackWeeks
@JackWeeks 3 жыл бұрын
Thank you for your question! I presume you are talking about protecting your expensive gauge from the shock in the system. The gauge is one of your most valuable troubleshooting tools, so it is crucial that it be taken care of. There are two common ways to do this. The best is a gauge isolation valve. This is a three-way pushbutton type valve that releases pressure from the gauge whenever it is not actively being read. You push the button and read the gauge, then when the button is released, pressure is drained to tank and the gauge drops to 0. Second best is a "snubber". This is a small, variable orifice flow control that you crack open when reading the gauge. By metering the flow to the gauge, spikes are eliminated. The gauge response is tempered, keeping it from damage while allowing the pressure to be read. Once you are finished monitoring the pressure, close the snubber, locking pressure in the gauge and isolating it from the system. Hope this helps!
@impactodelsurenterprise2440
@impactodelsurenterprise2440 3 жыл бұрын
Thanks for the reply, although what I meant was if pressure testing were to be done near to the pump, one would have to shut off the valve nearest to the pump yes? In that case, pressure acceleration would be extremely quick and likely destroy the pump, so how does one test for pressure near the pump safely?
@JackWeeks
@JackWeeks 3 жыл бұрын
OK, I think I see what you mean now. It is true that, in order to get a reliable pressure setting, the pump needs to be deadheaded. This is best done by blocking flow to everything in the system EXCEPT the system relief valve. If you are checking pressure with a fixed displacement pump, the pressure in the system will be determined by the relief valve. If your purpose here is to test the condition of the pump, you should also have a flow meter installed either upstream of the relief valve or in the relief valve tank line. Check the amount of flow first with the relief valve adjusted at a very low pressure. In this case, even a badly worn pump will deliver all or nearly all of its rated flow. Now, begin to slowly increase the pressure while monitoring the flow meter. If the pump is any good, there will be little if any change in the flow once you have reached normal system pressure. If, however, the flow drops more than ten percent, the pump is becoming worn and will soon need to be replaced (depending, of course, on the system flow requirements). If you are checking a variable displacement pump, the procedure is the same except that the pressure adjustment on the pump must be higher than the highest setting on the relief valve. This ensures that the relief valve is determining pressure rather than the pump, giving a reliable indication of the pump condition. In no case should a system be operated WITHOUT a relief valve. I have seen system designs with no relief valve, operating on the assumption that the pump regulates pressure so there is no need for a relief valve. This is dangerous, because the pump's pressure compensator valve can stick either open or closed. Depending upon the pump design, one way will keep any pressure from building in the system, the other will keep the pump at full stroke all the time, causing it to perform as a fixed displacement pump. Hope this answers your question!
@impactodelsurenterprise2440
@impactodelsurenterprise2440 3 жыл бұрын
Thanks for the detailed answer man I learnt alot. Have a great one.
The Difference Between Pressure and Flow
7:44
GPM Hydraulic Consulting Inc
Рет қаралды 11 М.
Alan 4 Things, 4 Tools For Effective Troubleshooting
19:23
GPM Hydraulic Consulting Inc
Рет қаралды 782
Best KFC Homemade For My Son #cooking #shorts
00:58
BANKII
Рет қаралды 73 МЛН
Jumping off balcony pulls her tooth! 🫣🦷
01:00
Justin Flom
Рет қаралды 28 МЛН
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 12 МЛН
Hydraulic System Inspection & Troubleshooting Session 2
24:10
MicroLeak Testing Hydraulic Components
14:31
Fluid Power Training Institute
Рет қаралды 66 М.
The Difference Between Pressure and Flow
7:34
Jack Weeks
Рет қаралды 525 М.
Regenerative Flow
4:29
GPM Hydraulic Consulting Inc
Рет қаралды 22 М.
Bypass testing a hydraulic cylinder
5:46
APT Specialist Hydraulics and Training
Рет қаралды 256 М.
Locked Compressors
20:13
HVAC School
Рет қаралды 110 М.
Counterbalance Valves
10:09
GPM Hydraulic Consulting Inc
Рет қаралды 78 М.
Hydraulics Troubleshooting 101: Mastering the Basics
3:23
Hydrauliac
Рет қаралды 634
Diagnosing Low Pressure in a Hydraulic System
4:21
Jack Weeks
Рет қаралды 233 М.
Best KFC Homemade For My Son #cooking #shorts
00:58
BANKII
Рет қаралды 73 МЛН