NOTE TO ALL DIY: If you stop any screw before it is completely into its final position, when you come back to fully set it, back the screw out slightly then drive it “home”, completely into its final position. The reason this fellow broke off 2 Tapcon screws is due to over torquing the screw. This usually only occurs if you start…stop….then start again.
@MoroMoro111 ай бұрын
Flushable toilet looks great. Everything is coming together well. Great inspiration
@MattSapp11 ай бұрын
On the broken tapcons - they usually don't just break for their own sense of fun. I would guess either your hole wasn't quite deep enough, or enough of the drilled out concrete dust stayed in the hole that it the screw got into it and hung up. Concrete dust cut by the screw threads can also fill up the bottom of the hole as the screw goes in. Unlike into wood or most other materials, the concrete has _no_ give, so if you don't have space for the screw, it'll bind up and shear off. I believe tapcon recommends overdrilling by at least 1/2", and also blowing out the holes with compressed air. For next time :)
@MasonDixonAcres11 ай бұрын
Thanks! I agree I probably wasn't deep enough to accomodate for any dust that may not have been cleaned out by the bit. I'll use air for larger holes but didn't for these small guys, also could have been an improvement although I believe it's actually not part of the instructions on these smaller screws
@kevinhornbuckle11 ай бұрын
Tapcons are great, when you can install them properly. Yes, the holes need to be deeper than the penetration of the screw. Set your driver to low speed for torque. Don't stop until the the head pulls down and then come off the heard quickly and decisively. Not too late and not too early. It takes practice.
@commonsense38468 ай бұрын
Tapcons are a PITA. They love breaking.
@kevinhornbuckle11 ай бұрын
Excellent video. You encourage people to pay attention to detail that matters. I suggest that people alway uses a quality angle stop, quarter turn shut-off valve. Do not buy cheap shut-off valves. As for the the supply rough-in, as you say, a drop ear 90 is best, with a brass nipple extending horizontally for the shut-off valve. My preference for wall covering around a toilet is tile. So use cement backer board instead of drywall.
@MasonDixonAcres11 ай бұрын
Interesting tip on the backer board! Thanks Kevin
@ppomm11 ай бұрын
always fun to see your progress Alex. My preferred way to put in toilets is to run 4" PVC up through the floor (3x4 closet bend common fitting everywhere). That way you can grout/fit tight to the floor then get flange that glues inside the 4" pipe,. Also, I guess no tile or other flooring down there? If so would be best to set flange after floor in, or shim it up so it will sit onto of final floor. Thanks for sharing your work.
@MasonDixonAcres11 ай бұрын
Thanks for the tips! Considered the 4" and closet bend, I think I went 3" + storm pipe collar just because I had everything on hand and wanted to avoid buying any pricey 4" pipe. The first floor is all garage/utility space, it will get epoxy flooring that will run up to the flange.
@kevinhornbuckle11 ай бұрын
Good advice.
@DamsLifestyle11 ай бұрын
Very nice video thanks for sharing
@BenKlassen111 ай бұрын
Very helpful, thanks.
@NickyC-g2n11 ай бұрын
Well I wasn't expecting the end, but it bloody cracked me up 🤣 Nice job on the toilet and don't forget to wipe!!🤣
@MasonDixonAcres11 ай бұрын
hahah just a little easter egg for those who watch till the end 🤣
@kevinhornbuckle11 ай бұрын
It is serious existential grounding to know that every time you take a dump, you built every inch of the waste system. Really, it makes going to the bathroom kind of fun and meaningful. You take care of your own shit.
@FJB202011 ай бұрын
Food for thought...rough in the water line on the other side of the toilet so the shut-off valve is hidden from view.
@MasonDixonAcres11 ай бұрын
Thanks! Definitely would have been more hidden here with the wall on the other side, 20/20 hindsight. On the upstairs bathroom it's 6 of one, half dozen of the other, but will certainly keep in mind for the future addition
@JL-hn6hi11 ай бұрын
I’ve always heard to keep radiant infloor pex away from the toilet drain to reduce the chance of the wax ring getting warm and potentially leaking. If you do try a wax ring, please let us know what happens.
@MasonDixonAcres11 ай бұрын
It would be fine either way, the floor temp won't exceed 80F
@bojangles_bonjangles800011 ай бұрын
Definitely don’t use black iron for a stub out! Or galvanized…They make copper stub outs that adapt to PEX from Sioux Chief that sweet onto a hero bar or the new hot items being installed are called MODA boxes from Oatey.
@MasonDixonAcres11 ай бұрын
Thanks! I've seen the copper bullet 90s, those would probably be what I go with in the future. I still like not having a joint behind the wall though, so it's a tossup for me. The little white pipe sleeve really isn't noticeable unless you're a plumber staring at it 😆
@aemenard3134 ай бұрын
The pose is 👌
@dspears66611 ай бұрын
Keep the water valve close to the wall. It doesn’t need to protrude that far and be so unsightly.
@MasonDixonAcres11 ай бұрын
Left it out a bit in the case of a future replacement
@RJ-cc1fz11 ай бұрын
To drill holes in concrete a hammer drill is used. Drills a lot easier and cleans out the hole better so the tapcons go in better and don’t snap..
@MasonDixonAcres11 ай бұрын
The holes drilled easily since they were so small and shallow, I think I may not have gone deep enough on the ones that broke
@HB-yq8gy9 ай бұрын
Those metal flanges rust out over time. I'm guessing the concrete is the finished floor? Otherwise, the flange rests on the finished floor.
@natfunk59927 ай бұрын
He knows everything.
@brainswole1016 ай бұрын
I'm working in a bathroom that is directly above an old cistern. Good news is I have access to the plumbing from below in the cistern. The customer wants to swap the location of the sink and toilet. I have never installed a complete toilet and drain. Just replaced toilets. Can I set the flange and secure it before running the drain to it? I don't have the tool you had to cut below the floor surface. What fasteners would you recommend so I don't run into the issue you had with them breaking. Any advice would greatly help and thank you. Great video.
@timolson700511 ай бұрын
a hub saver will drill out the pipe,, and will drill out the flange.. its essentially a giant PVC drill bit just for what you are doing come in all the PVC sizes
@MasonDixonAcres11 ай бұрын
I've seen those, very cool tools but having a hard time picturing how well it would work in this application though. I guess it would drill the flange out to a 4" diameter for a 3" flange to drop into. I hope to God I never have to conduct that repair 😆
@Thriving-uv2ce27 күн бұрын
Curious why you set the toilet onto the concreate instead of tiling your floor first, then setting the toilet on top of the tile? Are you going to tile around the toilet? If you ever swap out toilets, that will be an issue because your tile is matched to your existing toilet? Just curious and not sure if you covered that in the video. Thanks
@MasonDixonAcres26 күн бұрын
This is a garage/shop bathroom, no tile. Epoxy will be applied to the floor around the flange. Upstairs the toilet flange is set on a 1/2" plywood spacer where there will be tiled around it.
@dennismangels81477 ай бұрын
Try "One and done". Flange bolts for a normal toilet.,, you can thank me later..
@MasonDixonAcres7 ай бұрын
Never heard of them, interesting looking product. Surprised it's secure enough with just a hand tighten
@brainswole1016 ай бұрын
The toilet I'm installing has the same weird plastic piece to hook the toilet to the drain. Would you recommend silicone on the seal to help prevent leaks?
@chris_dahlen7 ай бұрын
Last comment was funny. A man needs to mark his territory.
@johnlaine265411 ай бұрын
Very surprised you don’t have Half flush/Full flush buttons on the water tank .In Australia this is compulsory. Half flush is 3 litres and Full flush 4.5 litres( sometimes 5 litres). Saves a lot of water with the 2 buttons over a year even.
@MasonDixonAcres11 ай бұрын
Used them before, never really thought about getting one for this shop bath to be honest. Definitely a good option in areas where water conservation is paramount
@andyallen17724 ай бұрын
No, you should put the flange on top of finished tile, not on the concrete subfloor.
@MasonDixonAcres4 ай бұрын
There is no tile, it's a shop bathroom
@corydriver763411 ай бұрын
Copper is ok but black iron is a big NO for water. Is the concrete your finished floor?
@MasonDixonAcres11 ай бұрын
True not sure why I said black iron. Only epoxy will go on the surface of the concrete
@theentirecolonyofjamestown18045 ай бұрын
i remember.
@natfunk59927 ай бұрын
Guess what. The closet flange is meant to sit directly on top of the finished floor surface. womp womp.