Derek in this video continues the gas quiz with a picture quiz on unsafe situations.
Пікірлер: 51
@andrewtomlinson182 жыл бұрын
Loving the picture quiz, great way of topping up the memory bank, more please please
@timeyre9985Ай бұрын
VERY informative, caught me out on a few of those. thank you very much for the training.
@all4heatinggaslimited402 жыл бұрын
Thank you Derek Your are always feeding up and brushing up our knowledges
@paulnixon4489 Жыл бұрын
I almost got 100 percent but you deffo stiffed me on the last one I noticed no sticker, but I'm calling spillage on the case and no controls. 😂. I. D.
@mohana.618510 ай бұрын
Yeh case and above looks as if it has kind of spillage and controls
@madmaycon25317 ай бұрын
Your videos are perfect and very clear. Tomorrow I have my ACS - Practical Assessment, I hope everything goes well.. Thank you very much.🙏
@tomkatgastraining7 ай бұрын
Good luck with it and let me know how you get on 👍🏻
@madmaycon25317 ай бұрын
Yes, I'll definitely let you know..But I'm very confident and everything will be fine.👊🙏👊
@lloydhocking39232 жыл бұрын
Best quiz so far, real life scenarios. Thanks
@joeblogs12369 ай бұрын
As usual spot on!!!.
@moulesanctuary Жыл бұрын
Keep them coming ... great to swat up
@johnward50062 жыл бұрын
Love these quizzes, humed and ha on q 2 . Q 3 I went for AR. Keep them coming. Unsafe Situations, even with IGEM11 can be confusing/ mis diagnosed.
@stabani6944 Жыл бұрын
Very helpful Great way to describe Loved it
@edmetcalfe89742 жыл бұрын
Really enjoy your videos Derek. We’ve disagreed in the past and I got a long way through this one thinking I might agree with your every assessment. There are two I might, possibly quibble with. Overall we’re on the same page though. Top work mate.
@mcginn0022 жыл бұрын
Keep them coming Derek 👍👍
@billybobhouse9559 Жыл бұрын
This is awesome! More please. I did get some wrong.
@fredthesavannahcat28992 жыл бұрын
This is good. Keep em coming
@mrturner87552 жыл бұрын
Super helpful please keep doing your videos
@jockster55252 жыл бұрын
Quality viewing mate 😉 thanks for your efforts 😊
@robertyoung31402 жыл бұрын
Brilliant bud. Thank you 😊
@mcDarkD2 жыл бұрын
6.46 not to right dimensions from back wall too, min 50mm(cant see the rest) and if someone did replace that cooker knob someones been there with a souring pad. guessing game. love your uplaods. 8.30 i have one of them close to me. but its a glowworm or vaillant. i have thought about dropping off an old flue from a taken out boiler so they can maybe get it righ "next time". selfish i know. i just dont want gas safe inspector assuming i did that work. if i got all your questions right what do i win!!! i guess i failed though...................i never riddored anything.
@stevenmiller37842 жыл бұрын
Very enjoyable , the cooker knob thing is a bit grey, maybe remove another knob , purge and relight , observe flame picture etc Albeit the hob shown would be a candidate for the above lol
@kevj19642 жыл бұрын
Great Quiz Derek.
@joshd790 Жыл бұрын
Great video
@jonessenoj6753 Жыл бұрын
Great video 👍
@robincurwood5 ай бұрын
The final picture looks like it has soot marks on the casing. Surely makes it ID?
@joco5906 Жыл бұрын
Hi Derek, great vids as always! regards the final example (the water heater). Should we not also be concerned about the positioning of the plug in relation to the hot gases exiting the flue and the control knob is missing - wasn't that I.D.?
@lj44348 ай бұрын
Thanks alot
@MindMechanicsIC2 жыл бұрын
Great content on pretty much all videos, very helpful & informative. One suggestion, if possible, would be to link any downloadable documents for us to access.
@tomkatgastraining2 жыл бұрын
I wish I could mate but the documents are not free
@MindMechanicsIC2 жыл бұрын
@@tomkatgastraining understood 👍🏼
@mervinpermalloo8589 Жыл бұрын
🙏😊
@muzzz332 жыл бұрын
Number 9 would only be AR if it was not sealed internally and the flue was insecure . If it's just not cemented externally and no products entering then only NCS . Also the meter box one , most boxes of that type have the service and installation pipe work passing through that outer edge of the box but at the bottom, so how is it AR when it's at the top? . Are you suggesting there is a pathway for gas to enter the building when it passes through the top but not if it passes through the bottom as normal? This would be AR if it passes through the back of the box and not sealed allowing gas to potentially pass into the property .keep up the good work with these videos ,great resource for trainee's .
@tomkatgastraining2 жыл бұрын
Number 9 is AR as the flue is not sealed and products of combustion could enter the cavity and the meter box one is AR as the integrity of the box is broken so it’s classed as like the door is missing.
@sebastiaandevries6428 Жыл бұрын
funny that some things are considdered worse in the netherlands and some not
@carlfisher51952 жыл бұрын
If in doubt... ID it and put it right...!!
@tomkatgastraining2 жыл бұрын
If it’s ID and riddor you will still need to report the riddor even if you fix it and what if you ID an NCS
@SuperWayneyb2 жыл бұрын
🤘😎🤘
@marvindallen89162 жыл бұрын
👍🏾
@mohana.618510 ай бұрын
14 looks as if it has some spillage, am I wrong?
@tomkatgastraining10 ай бұрын
Yep
@mohana.618510 ай бұрын
@tomkatgastraining yep as I am wrong? Or yep I am right?
@tomkatgastraining10 ай бұрын
@@mohana.6185 wrong
@trevcam6892 Жыл бұрын
I'm no gas engineer but in the thumb nail picture it seems to me that on the flue there should be a grommet to cover the hole to prevent CO ingress. I just took a gander at my boiler and there's no hole there at all. My service engineer puts the gas probe in the sampling port above when serving my boiler.
@mattylad80352 жыл бұрын
As a non RGI - What's ID? I understand RIDDOR. (I got several right). Is it Immediately Disconnect ?
@tomkatgastraining2 жыл бұрын
Close immediately dangerous 👍🏻
@k956upg17 күн бұрын
This is an ok idea aaa video but it’s painfully slow listing the at risk ncs id etc being slowly listed every question
@tomkatgastraining17 күн бұрын
@@k956upg that my friend gives you the time to think what the answer is
@tonyadams3802 жыл бұрын
Can't go with no.10! You can't ID and RIDDOR work that hasn't even been carried out. And what idiot would install it then RIDDOR their own work?
@tomkatgastraining2 жыл бұрын
Don’t get you number 10 is the boiler that a builder has removed the walls around the boiler and is holding it up with wood and then has used a bit of rainwater pipe as a flue extensions. So you find the boiler the way of the picture so how’s that not ID and riddor
@tonyadams3802 жыл бұрын
@@tomkatgastraining Yes I do now mate. Sorry.Totally got the wrong end stick. Sorry to hear your not doing the quizzes for now. Can't stress the importance of engineers understand IGEM G11 enough. Hope they pay more attention than I obviously did when I'm teaching them🙄