Topping up a Worcester Boiler- Keyless Filling Link

  Рет қаралды 170,956

LCD Heating & Gas Services Ltd

LCD Heating & Gas Services Ltd

5 жыл бұрын

A quick video on how to top up the pressure on your Worcester boiler if it is fitted with a keyless link , there are a few different ways of filling your combi boiler but this video describes how to top up specifically if your Worcester boiler if it is fitted with the keyless filling link .
www.lcdheatingandgas.co.uk

Пікірлер: 83
@Gingerchalky
@Gingerchalky 5 ай бұрын
Thank god I googled this again and found your video. Hopefully saved me some money on now not needing to get an engineer out
@glasgowfunctionsify
@glasgowfunctionsify 4 жыл бұрын
Cheers for this. Wrongly ordered the white key & wondered why they didnt fit. You saved me from calling someone out. Ty 👍
@hermiteka5360
@hermiteka5360 2 жыл бұрын
Thank you so much . I was going to Loose my mind , from all the video this by far was easy to follow
@pulpopelirojo68
@pulpopelirojo68 Жыл бұрын
Thank you! Even the landlord was saying "Use the key", to which my response was "What key?!"
@VikaFirsova1
@VikaFirsova1 Жыл бұрын
OMG so simple! Thank you a million for this video!
@darrencady4261
@darrencady4261 4 жыл бұрын
Many thanks, my friend. You're a lifesaver.
@brianherring6393
@brianherring6393 4 жыл бұрын
Thanks for the information it save me looking through all the details cheers pal
@dreamkiss
@dreamkiss 8 ай бұрын
Thank you, I have just sent this video to my student house and they have manged to top this up
@lawrenceellard2084
@lawrenceellard2084 3 жыл бұрын
Thank you, this video really helped us
@natalyclifton7097
@natalyclifton7097 Жыл бұрын
Thank you so much! Incredibly helpful! Didnt need to call anyone.
@Nofsman
@Nofsman 5 ай бұрын
Saved me a few quid. Nice one!
@briansilver6196
@briansilver6196 4 жыл бұрын
Thanks for that ,it just saved me calling out an engineer
@tiagofermar
@tiagofermar 9 ай бұрын
You’re a life saver! Cheers!
@dahlicieusequeenpantheretv31
@dahlicieusequeenpantheretv31 2 жыл бұрын
Thank you so much for your help, God bless you 🙏👍
@Quagmire1428Gaming
@Quagmire1428Gaming 4 жыл бұрын
cheers mate. when i didn't find the key i was rather confused.
@davidtilley6840
@davidtilley6840 3 жыл бұрын
Thanks been looking everywhere for the key lol
@saminamirza2464
@saminamirza2464 3 жыл бұрын
Same
@russfillingham9910
@russfillingham9910 2 жыл бұрын
Brilliant so simple, I knew that I had done it a few years ago but couldn't remember but this video was SO bang on 😊👍
@bernievee72
@bernievee72 2 жыл бұрын
Very helpful, thank you!
@BasG74
@BasG74 4 жыл бұрын
Thank you, that was easy!
@MTGBella
@MTGBella Жыл бұрын
Thank you so much 😭 I thought the boiler was broken
@asheeyapardesi4085
@asheeyapardesi4085 3 жыл бұрын
Thank you for your help this works
@gregorypalamas4998
@gregorypalamas4998 2 жыл бұрын
Super helpful 👍
@noornajeeb1583
@noornajeeb1583 3 жыл бұрын
Great video
@charliegardner6804
@charliegardner6804 2 жыл бұрын
Thank you much appreciated 👍.
@PsychicMediumshipSelkie
@PsychicMediumshipSelkie Жыл бұрын
Thank you. You just safe me money. Xxx
@kravdraa7
@kravdraa7 2 жыл бұрын
As can be seen from other posts, I think there is a design flaw in this filling valve which leads to a variety of issues. I'd like to hear if installers are aware of such a problem.
@limeyperson
@limeyperson 3 жыл бұрын
Thanks a lot!
@greenskunkgaming7880
@greenskunkgaming7880 3 жыл бұрын
Nice one 👌👍
@meggyfrome8400
@meggyfrome8400 3 жыл бұрын
On mine the blue lever is not sturdy ( very floppy ) not a firm on and off . Tried it but didn’t feel confident so didn’t continue
@christophermee5214
@christophermee5214 3 жыл бұрын
What is the plastic cup like clip on the left of the blue filler tap
@ahmadansarimonzamy945
@ahmadansarimonzamy945 Жыл бұрын
Hi, first time trying to repressurizing and find the blue lever too hard to be pushed down, any advice? Thanks
@RaStan75
@RaStan75 2 жыл бұрын
Thanks 👍
@haydengee
@haydengee 2 жыл бұрын
Some man💪🏼
@barstoolpreacher7851
@barstoolpreacher7851 Жыл бұрын
Mine won't open seems to be seized is there a way to bypass the blue pull down lever to re pressurise the system after bleeding radiators?
@OHbosh
@OHbosh 2 жыл бұрын
Roughly, How long would it take to pressurise system from 0 bar in 3 bed terrace?
@tallulahcc
@tallulahcc Жыл бұрын
Hi, I've just highered mine to 1.5 is that OK? Or too much? Thank you :)
@rafafederer832
@rafafederer832 6 ай бұрын
Can pull my blue lever down but no water flows to top it up. It used to work as a plumber emptied system installed a new radiator then refilled and bled radiators In my manual it shows the lever pulled down to 90 degrees so erotically for topping up I can’t get the lever past about 60 degrees
@goych
@goych 2 жыл бұрын
Hey gang I’ll just add you might want to check any error codes if that’s something easy to do, I did that then did a reset and the system was able to raise the pressure to the green again, I note my blue key is still inoperable at present though having been fine before
@priteshchauhan1851
@priteshchauhan1851 4 жыл бұрын
Thanks, I have this system too, does the boiler need to be off when repressurising?
@lcdheatingandgas
@lcdheatingandgas 4 жыл бұрын
HI , its best to top up when the system is cold and the programmer is off
@ritagardner7413
@ritagardner7413 3 жыл бұрын
My key is stuck. Any ideas why and how to get it moving as boiler on 2 bar red. ?
@siofra3819
@siofra3819 Жыл бұрын
I just have the two parts with the black rubber around them. I don't have the blue leaver
@jameswilkinson3281
@jameswilkinson3281 Жыл бұрын
Can frozen pipes prevent filling? I attempted to top my boiler up this morning as I have done before, but after a few seconds the water stopped and went silent. It was a cold night last night, so I am wondering whether the pipe may be frozen, or could the valve be broken??
@daleprosser350
@daleprosser350 Жыл бұрын
If your incoming pressure isn’t the best, say 1.5 bar for instance, then you can’t fill your system any higher than that
@alexisamtosta
@alexisamtosta 3 жыл бұрын
Mine does not have either the key or the blue leaver and the pressure is at zero.
@penallylad
@penallylad Жыл бұрын
I have this type of pressure key you show but I can't pull the blue lever down, it seems to be jammed. Any ideas?
@shizhongli5035
@shizhongli5035 6 ай бұрын
Pull harder, me got same problems
@shmink2
@shmink2 Жыл бұрын
I've been pulling that but the current pressure isn't changing.
@pianoman8642
@pianoman8642 6 ай бұрын
Nothing happens when I pull the lever down. It used to work. Any ideas?
@jedirabbit6275
@jedirabbit6275 3 жыл бұрын
What do you do when your blue leaver doesn’t pull down? Ours did at first now a year or so on and at zero pressure the blue leaver won’t move not sure what’s happened but don’t know what to do to fix this.
@rareamigo
@rareamigo 3 жыл бұрын
Does anyone have an answer for this?
@nicolettebarratt8315
@nicolettebarratt8315 Жыл бұрын
Mine is now like this, was you able to solve this? #JediRabbit
@jedirabbit6275
@jedirabbit6275 Жыл бұрын
@@nicolettebarratt8315 yeah through brute force, was scared I was going to snap it off. Maybe try and get a bit of wd40 on there but be careful.
@nicolettebarratt8315
@nicolettebarratt8315 Жыл бұрын
Thank you so much for your reply
@RevanTheLegend
@RevanTheLegend 10 ай бұрын
What to do if the blue lever WONT pull down?
@TheLARALEWIS
@TheLARALEWIS 3 жыл бұрын
i have no key, no blue lever. It was only installed last year and I have no idea where the hose is located . I am at a complete loss to work out how to increase my water pressure. I am going nuts watching you tube videos...
@ariesvibration
@ariesvibration 2 жыл бұрын
I have same problem, keyless no blue lever but red lever at the back
@JimKP
@JimKP 2 жыл бұрын
Any resolve? Same problem here
@andreachiarenza9657
@andreachiarenza9657 2 жыл бұрын
@@ariesvibration same here…did you manage to fix the problem? Thanks!
@penny8838
@penny8838 3 жыл бұрын
I pulled lever down but no water sounds, nothing. Am i doing something wrong?
@cv6717
@cv6717 Жыл бұрын
I have the same problem did you find out how to repressurise
@NinjaLou2074
@NinjaLou2074 8 ай бұрын
Any ideas I’ve got sane issue
@meggyfrome8400
@meggyfrome8400 2 жыл бұрын
My lever isn’t sturdy like this , more floppy and has made me nervous to pull on it , any engineers experienced this before and can reassure me to give it a go . Thanks
@smartiepancake
@smartiepancake Жыл бұрын
Mine's the same. I pulled it down hard and it started letting water in, then it wouldn't switch off fully until I tapped directly upwards using a hammer. Pressure by that time was way too high - getting up towards 3. I had to drain at least 2 pints to get it down. I think I'd like to remove this thing tbh.
@meggyfrome8400
@meggyfrome8400 Жыл бұрын
@@smartiepancake thanks for replying much appreciated, from your experience and my trepidation I’m gunna leave well alone and let the experts do it . Thanks so much for sharing this with me it’s been so helpful 👍🏻
@DonnaStacey
@DonnaStacey Жыл бұрын
We don’t have either a key or the blue leaver anybody any ideas I’m freezing
@booneyinc9515
@booneyinc9515 10 ай бұрын
I have this. Whenever I top up the pressure to 1 bar. I'll come back a few hours later and the pressures gone up more. I don't know if there is a fault with the valve letting more water through. Anyone got any ideas?
@RhysMorgan2015
@RhysMorgan2015 8 ай бұрын
You can expect the pressure to rise a bit higher when the heating is on as water expands when heated. It should not be going too high (over 2 bar) though. If it does there might be a problem with your boiler.
@cv6717
@cv6717 Жыл бұрын
I dont hear any water and its making a high pitched noise
@martaaguiriano7025
@martaaguiriano7025 2 жыл бұрын
How to reduce boiler preassure worcester
@grahamtricker4103
@grahamtricker4103 2 жыл бұрын
Bleed the radiators using the bleed screw and this will lower the water pressure in the system
@grveyardshft
@grveyardshft 2 жыл бұрын
Any idea what to do if you pull the lever down and nothing happens?
@kravdraa7
@kravdraa7 2 жыл бұрын
I've been looking for a similar answer. My boiler is less than 3 years old and has had the issue from day one. First, the operation of the lever differs from the manual, which suggests it should be able to go to 90' from its resting position. That appears to be misleading. Second, the ability to fill and the speed of it will likely depend upon the pressure differential between mains and boiler. Our mains pressure is not particularly high and our boiler is in the attic, so filling is more difficult anyway. Finally, I suspect that there is a common fault in these lever controlled valves, but Worcester won't acknowledge it. Sometimes they work, sometimes they don't. Not good!
@grveyardshft
@grveyardshft 2 жыл бұрын
@@kravdraa7 Yeah mate its weird isnt it. Ours isnt very old at all either, probably around three years as well. I can remember doing it at one point and it working but the last couple of times ive tried, nothing.
@davidsalter4324
@davidsalter4324 2 жыл бұрын
Mines a week old and already its saying low pressure, the blue switch does nothing at all
@kravdraa7
@kravdraa7 2 жыл бұрын
@@davidsalter4324 I have discovered a way to get some filling, which might help you. You need to temporarily 'jam' the valve open (I did this with a piece of foam lagging) and then repeatedly turn on and off another tap, on the same mains feed. I think a rapid turning off the tap may assist. I believe there is a slight and sudden increase in pressure just as you turn it off and that helps to push water into the system. Once you get it up to an acceptable level, you can return the lever to normal. I actually left mine open for a couple of days and this has been the only way to get my system filled!
@sonofthebear5301
@sonofthebear5301 3 ай бұрын
@@kravdraa7 So glad I found your comment! Very slow to refill but nothing was happening until I tried the tap trick. Thanks for sharing this 2 years ago!
@jaswindersingh-de9lv
@jaswindersingh-de9lv 2 жыл бұрын
Fill up the boiling gone to 2,5 pressure would be ok
@ThermionicValve
@ThermionicValve 2 жыл бұрын
I hate this type of valve, they have a habit of getting stuck in the down position and needs to be pushed up manually. Very poor design.
@smartiepancake
@smartiepancake Жыл бұрын
is "up" off ie no water filling?
@ThermionicValve
@ThermionicValve Жыл бұрын
Yes, up position is off or closed. To pressure or full the radiator system you pull the leaver down and simply let go to stop. Sometimes it gets stuck and it keeps on filling resulting in too much pressure.
@smartiepancake
@smartiepancake Жыл бұрын
@@ThermionicValve exactly what just happened to me :-) cheers. I tapped it back with a hammer. the return spring is obviously not up to it.
How to fit the Keyless Filling Link
2:46
Worcester Bosch
Рет қаралды 60 М.
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 35 МЛН
路飞太过分了,自己游泳。#海贼王#路飞
00:28
路飞与唐舞桐
Рет қаралды 36 МЛН
Я обещал подарить ему самокат!
01:00
Vlad Samokatchik
Рет қаралды 9 МЛН
Why Does My Boiler Keep Losing Pressure?
36:37
Skill Builder
Рет қаралды 393 М.
Topping up a Worcester Boiler - Filling Link With The Key
1:51
LCD Heating & Gas Services Ltd
Рет қаралды 75 М.
Worcester Bosch CDi Compact ERP Full Service
19:01
CP Utility Solutions
Рет қаралды 17 М.
Worcester Bosch Review - Common Faults - Sherburn Plumber
11:51
Allen Hart
Рет қаралды 227 М.
Small Act of Kindness is also a charity
1:00
PainCare _Trust
Рет қаралды 48 МЛН
ДОМАШНЕЕ ЭСКИМО//ПРОВЕРКА РЕЦЕПТА ТИК ТОК
0:22
ОЛЯ ПЕРЧИК
Рет қаралды 1,4 МЛН
Small Act of Kindness is also a charity
1:00
PainCare _Trust
Рет қаралды 48 МЛН