Trane Chiller Unloader Rebuild - HVAC School

  Рет қаралды 16,415

HVACTIME

HVACTIME

Күн бұрын

#tranechiller #hvactraining #hvacschool #hvacsurvival #hvac #hvacr #refrigeration #hvacrvideos #trane #chiller #aircooled
Another hvacr videos to help show hvac troubleshooting. If you are considering joining the hvac trade I highly suggest getting hvac training from a trade school. Online hvac training videos only get you so far. From experience hvac school is the way to go. No matter what you call it HVAC, HVACR, Refrigeration, Air Conditioning, Chillers, Low Temp, High Temp, Mechanical, ect, we are all blue collar in this hvac life.
Check out Merch Store! my-store-b413f...
You can contact me at Hvactimetx@gmail.com
You can also follow me at, Instagram / hvactime Facebook / hvactime
Support the channel through, venmo.com/code...
Zelle @ Hvactimetx@gmail.com

Пікірлер: 26
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Nice video man! Gotta love those large chillers! Keep up the good work.
@HVACTIME
@HVACTIME 3 жыл бұрын
Every day!
@onemischiefmaker7032
@onemischiefmaker7032 3 жыл бұрын
Large chiller what's the largest air cooled chiller? 500 or 600 ton?
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
@@onemischiefmaker7032 you can get some big chillers if you need them, If you need more tonnage just have a few of em!
@SombraLocs
@SombraLocs 3 жыл бұрын
Keep them coming!👍
@Voxus77
@Voxus77 3 жыл бұрын
Need people like you in Australia running training man!
@mansourghadhban236
@mansourghadhban236 2 жыл бұрын
Good job 👍
@ponkrapujari679
@ponkrapujari679 2 жыл бұрын
👍👍
@mansourghadhban236
@mansourghadhban236 Жыл бұрын
Thnxs more Nd more good job
@syedbasheer8210
@syedbasheer8210 3 жыл бұрын
👍👍👍
@mansourghadhban236
@mansourghadhban236 2 жыл бұрын
Technician mansour from Iraq
@Tparker9969
@Tparker9969 3 жыл бұрын
I'm working on an RTAA270 I have read through RTAA service bulletin 18 & 4 and each of the service bulletins state that the lip seal is not serviceable in the field. I'm curious to know if you understand why that is stated that way since you can obviously buy the unloader Puck assembly along with the gasket and O-ring for the discharge. I watch all of your videos and this one directly relates to an issue I'm working on right now considering it's the same chiller as well as the same compressor that's having the same issue. Also wouldn't it just be easier to replace the unloader Puck instead of putting the bypass kit on? I'm just wondering if the reason they make that kit is a cost issue?
@mansourghadhban236
@mansourghadhban236 2 жыл бұрын
Am changing different types of Train control to New carel control so SKM control
@mansourghadhban236
@mansourghadhban236 2 жыл бұрын
How can we change New control for other models. To Train
@TechnicalBrainHVAC
@TechnicalBrainHVAC 3 жыл бұрын
I have rtda 085 chiller.after runing 5 minuts oil temperature 🌡 fell down from 62c to 37c and compressor making noise and pressure around Suction 45PSI liquid line 150psi
@HVACTIME
@HVACTIME 3 жыл бұрын
Sounds like your compressor is flooding. Either a water flow issue or exv over feeding. The saturation sensor and suction sensor are notorious to fail. Thoughts?
@TechnicalBrainHVAC
@TechnicalBrainHVAC 3 жыл бұрын
@@HVACTIME i changed liquid line sensor also but same situation.oil cooling lines become cool
@HVACTIME
@HVACTIME 3 жыл бұрын
I would need more details on specific readings but heres what I see so far. 1. 5min run time is when circuit will start loading up after startup. 2. The oil temp drops rapidly at loading. 3. The suction pressure is highish at 50F of saturation at loading. 4. Compressor changes sound Those variables suggest a flooding state.
@maxprane5184
@maxprane5184 3 жыл бұрын
Nice video man! have one and RTAA125 presents an alarm (oil Flow Control) how to solve?
@HVACTIME
@HVACTIME 3 жыл бұрын
Need to check your oil temp
@sajawalwali6559
@sajawalwali6559 2 жыл бұрын
Hello HVAC TIME ....can you just send me full video of loader unloader piston change
@fathmasameer7523
@fathmasameer7523 3 жыл бұрын
Brother how long it took to recover one circuit ? very helpfull video for me thanks
@HVACTIME
@HVACTIME 3 жыл бұрын
Less than a day for circuit 2 135# and a full day for circuit 1 360#. Circuit 1 was overcharged, factory was 318#
@BleedingEdgeHVACR
@BleedingEdgeHVACR 2 жыл бұрын
Is there anything wrong with using a wire wheel on drill or grinder to remove the pieces of old gasket that way? Or is it too risky?
@HVACTIME
@HVACTIME 2 жыл бұрын
Wire wheel is good to use. Just becareful not to sit and score up one spot.
@mrbyamile6973
@mrbyamile6973 7 ай бұрын
A good gasket scraper with replaceable blades and scotch bright does a great job. Just clean everything up good, scotch bright abrasive crumbling off the pad will damage surfaces I'd left in the system.
Low Oil Troubleshoot RTAA Chiller
11:24
HVACTIME
Рет қаралды 15 М.
Trane RTAC Leak Repair + Oil Filter Part 1
19:57
DFW HVAC
Рет қаралды 12 М.
English or Spanish 🤣
00:16
GL Show
Рет қаралды 8 МЛН
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 22 МЛН
Cooling Tower PM Basic's HVAC Training for HVAC Technician
34:57
Trane CVHE Chiller Overhaul Rebuild
3:28
Thermetrics Corp
Рет қаралды 49 М.
You Laugh You Lose | Dumb Fails
19:18
FailArmy
Рет қаралды 6 МЛН
Compressor Unloader - HVAC Online Training and Courses
11:37
Aircon Academy
Рет қаралды 144 М.
Chiller Shaft Seal Repair on York YK Centrifugal
15:50
HVACTIME
Рет қаралды 33 М.
How to Change Terminal Plate on Trane CHHP Screw Compressor
8:32
National Compressor Exchange, Inc
Рет қаралды 2,2 М.
2 Bad Compressors In Weeks WHY? Freezer Down
29:40
HVACR Survival
Рет қаралды 19 М.
English or Spanish 🤣
00:16
GL Show
Рет қаралды 8 МЛН