Tripping circuit (1/2) for SIEMENS Reference Breaker 132 KV, TRIP CIRCUIT SUPERVISION

  Рет қаралды 19,749

BEING ELECTRICAL

BEING ELECTRICAL

Күн бұрын

NO/NC, PRE CLOSE & POST CLOSE POINTS DETERMINATION, IMPORTANCE AND CONNECTIONS. REMOTE TRIPPING POINT & TERMINATION.
132 KV SF6 BREAKER CONTROL SYSTEM BASICS WITH EXPLANATION, INTERLOCKS, CONDITIONS, RESTRICTIONS AND SAFETY. A MUST WATCH FOR DEEP KNOWLEDGE.

Пікірлер: 63
@learnelectricity1
@learnelectricity1 8 ай бұрын
Great 👏👏👏. Keep giving us new videos
@user-wm5ti1od6r
@user-wm5ti1od6r 23 күн бұрын
Superb picture diya hii sir
@jayabikash
@jayabikash Жыл бұрын
Superb
@mdaashique3164
@mdaashique3164 3 жыл бұрын
Ap great teacher ho sir, itna acha explain koi nhi kr skta.... Thank u 🙏🏻
@mdnadeemkhan511
@mdnadeemkhan511 Жыл бұрын
Weldon sir
@farhatfatem6314
@farhatfatem6314 Жыл бұрын
Thanks sir for clearing the concept.
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
Happy to hear.. pls stay tuned
@AjeetKumar-iq7fp
@AjeetKumar-iq7fp 2 жыл бұрын
Thank you sir share knowledge easy explanation
@seasonalart100
@seasonalart100 3 жыл бұрын
Dhanyawad sir itna achha aur sadharan tarika se samjhane ke liye🙏 yek request sir please master trip relay circuit ka jaankari bhi sajha Karen .
@amarsajjad1998
@amarsajjad1998 3 жыл бұрын
Goooood
@ranjansahu2362
@ranjansahu2362 3 жыл бұрын
So good sir.. waiting for panel drawing..
@yogeshshrivatsa5540
@yogeshshrivatsa5540 3 жыл бұрын
Explain differential relay and its relay settings.Thanks.
@pappusony6761
@pappusony6761 2 жыл бұрын
very good explain sir thank you
@anamikasinha6256
@anamikasinha6256 2 ай бұрын
Thank you sir
@md.alamgirchowdhury9084
@md.alamgirchowdhury9084 2 жыл бұрын
👍👍👍
@punamchand4059
@punamchand4059 3 жыл бұрын
Very nice video sir
@md.alamgirchowdhury9084
@md.alamgirchowdhury9084 2 жыл бұрын
Nice presentation 💖
@RaipurihaRajkumar
@RaipurihaRajkumar 2 жыл бұрын
👍
@mindtricks8769
@mindtricks8769 3 жыл бұрын
Nic video good going👌
@siyaramsharan1122
@siyaramsharan1122 3 жыл бұрын
Nice sir thank you so much
@surendrakverma555
@surendrakverma555 3 жыл бұрын
Very good
@MdSharifulHassanpalash
@MdSharifulHassanpalash 3 жыл бұрын
Thanks for this contribution. Go ahead, please describe about siemens differential relay
@ROHIT-KUMAR.
@ROHIT-KUMAR. 2 жыл бұрын
Thanks 😊
@md.alamgirchowdhury9084
@md.alamgirchowdhury9084 3 жыл бұрын
Please please make isolator control circuit diagram vedio.
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
We will goto isolators after control and relay panel .. pls stay tuned
@rakeshghorpade4956
@rakeshghorpade4956 3 жыл бұрын
Sir please reading vedeo of sf6 220 kv braker drawing of Siemens Thank you sir for previous vedeo
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
Real soon my friend
@appliedelearning8651
@appliedelearning8651 3 жыл бұрын
Please Upload More Videos
@md.alamgirchowdhury9084
@md.alamgirchowdhury9084 2 жыл бұрын
Sir isolator open close control diagram vedio Dena.
@ssundaramurthy
@ssundaramurthy 3 жыл бұрын
any reference books available regarding this circuits?
@BikashkSingh
@BikashkSingh 2 жыл бұрын
Many many thanks, Sir.I am able to understand easily.
@syeedaijaz1
@syeedaijaz1 Жыл бұрын
Hi, very good sir ji, mujhe Schneider electric ki Control diagram explain kareye please close and tripping circuit of sf6..
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
Please givee the drawing u want a discussion on.. however detailed information videos on sf6 circuit breaker for Siemens and CGL make are available on the channel
@jayshriram905
@jayshriram905 4 ай бұрын
Aapke pas schedule bhejna hai sir kaise bhej sakte hai hamko samjhna hai aapse
@devdutt2059
@devdutt2059 3 жыл бұрын
Sir what about a video on control pannel and also I couldn't find video for indication ckt.
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
Hasnt been uploaded yet. Will do ut shortly regarding indication circuit. Control panel.is a complete series
@brajeshvishwakarma6933
@brajeshvishwakarma6933 Жыл бұрын
33kv popular make 3 feeder panel me t n c switch ki wiring diagram bata dijiye
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
Drawing bhej dijiye... Shall try to explain... However a video on general explanation for tnc switch can be made..
@yagnikpansuriya1267
@yagnikpansuriya1267 Жыл бұрын
K10 ka auxiliary contact Closing circuit me bhi hona chahiye...
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
Hota hai.. watch the video of closing circuit in the playlist
@usmanyousaf3180
@usmanyousaf3180 3 жыл бұрын
Kindly describe the interlocking of 86 Tripping relays during closing and opening.
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
Sure thing. Will do it soon
@bikashkumarsahoo946
@bikashkumarsahoo946 2 жыл бұрын
Why resistor are used in trip circuit supervision relay...
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
To prevent unwanted tripping, in case relay coil gets burnt, thus injecting zero resistance in the circuit. Additional resistance helps to drop the voltage to bring down upto non operable range of coil
@Abcdef5411k
@Abcdef5411k 2 жыл бұрын
132 kV cgl breaker me remote par rakhne par breaker open ho Raha h, please is fault par video banaye sir.
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
CRP ke TNC switch ka tripping contact check kijiye.. continued conduction de raha ho shayad
@Prem-cricket-Adda
@Prem-cricket-Adda 3 жыл бұрын
Isolator and earth switch ke interlocking ke ,liye ek video banaye sir,, ya Mera doubt clear kr dijiye interlocking ka function smj nhi aa rha h sir ,,please
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
Mechanical interlock to easily dikh jaata hai.. electrical interlock ke baare me pooch rahe hain?
@Prem-cricket-Adda
@Prem-cricket-Adda 3 жыл бұрын
@@beingelectrical6641 ji sir electrical interlocking me 400kv gis substation pr hu interlocking jise drawings se smj kr condition Jan sake
@jajbimallick6443
@jajbimallick6443 3 жыл бұрын
Respected Sir Why are you not using K10 for Postclose Supervision. Kindly explain. Regards
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
K10 (density monitor multiplier) is meant for gas pressure supervision, which is guided/ controlled through B4 (gas density monitor). It allows/prohibits the breaker from operating as per the gas pressure status through its NO contact in closing & tripping circuit, and informs the user regarding gas pressure status through 2 no of alarms 1. Gas pressure low (1st stage)- NC of B4 2. Gas pressure lockout(2nd stage)- NC of K 10. K10 therefore is a dedicated supervision cum controlling component in respect of gas pressure status. Whereas Pre close & post close supervision are meant for healthiness of tripping coil. If contact of K10 is also included in the supervision circuit, there stands a chance that low gas pressure may trigger TC unhealthy status through 95 relay, which might be a misinformation to the user regarding trip coil. However, some designs do include gas pressure in supervision, like CGL. It depends on the designer.
@jajbimallick6443
@jajbimallick6443 3 жыл бұрын
@@beingelectrical6641 Thank you sir for your kind guidance. Regards
@deepdiljot1388
@deepdiljot1388 2 жыл бұрын
How to spring charge
@beingelectrical6641
@beingelectrical6641 2 жыл бұрын
Electrically or mannually
@yagnikpansuriya1267
@yagnikpansuriya1267 Жыл бұрын
TCS relay ko kaise lagaye?
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
There is a seperate video for that... Please go through the playlist once.. and let me know if u need in depth connection diagrams
@abdulhamidabdullahi5634
@abdulhamidabdullahi5634 Жыл бұрын
What about the English version for those that don't understand hindj
@beingelectrical6641
@beingelectrical6641 Жыл бұрын
If required in English, another video for the requested topic can be uploaded. Please express your need. Shall try to upload in English
@pankajsanwal2010
@pankajsanwal2010 3 жыл бұрын
Sir इस circuit में dc supply कितने volt use होती है कृपया बताने का कष्ट करें । धन्यवाद ।
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
Jo bhi control voltage hoga aapke system ka.. generally 250 v dc designed hota hai
@pankajsanwal2010
@pankajsanwal2010 3 жыл бұрын
बात हजम नहीं हुई । इंडस्ट्री में D. C सप्लाई या तो 24 volt जो कि L T switchgears में प्रयोग होती है । या फिर 110 volt DC kका बैटरी bank होता है । 250 volt DC कभी सुना या देखा नहीं ।
@beingelectrical6641
@beingelectrical6641 3 жыл бұрын
Substations me use hoti hai 250 volts. Ye control voltage system designer pe depend karta hai. Accordingly switching components select kiye jaate hain control logic ke liye
1,000 Diamonds! (Funny Minecraft Animation) #shorts #cartoon
00:31
toonz CRAFT
Рет қаралды 41 МЛН
Why Is He Unhappy…?
00:26
Alan Chikin Chow
Рет қаралды 71 МЛН
Smart Sigma Kid #funny #sigma #memes
00:26
CRAZY GREAPA
Рет қаралды 7 МЛН
What is Circuit Breaker Control Schematic/Circuit | TheElectricalGuy
10:03
Gaurav J - TheElectricalGuy
Рет қаралды 5 М.
Circuit Breaker Operating Mechanism, Must watch video
6:48
KashTech
Рет қаралды 10 М.
Trip neutral close (TNC) Switch - Basics and wiring
10:21
Insight Tecs
Рет қаралды 16 М.
VCB closing circuit in Tamil
19:34
Electrical Mastar in Tamil
Рет қаралды 10 М.
Do yourself !!! Only 10 wire to full control over 33kV VCB/SF6 by ABB.
13:10
BD Professionals-বাংলায় শিখি
Рет қаралды 10 М.
What is Master Trip Relay| What is 86 Relay| REF 615 | REM 615| How Relay Works
8:12
Electrical With Abhishek Joshi
Рет қаралды 102 М.