This one covers a history of the venting materials used to vent gas furnaces.
This video is part of the heating and cooling series of training videos made to accompany my websites: www.graycoolingman.com and www.grayfurnaceman.com to pass on what I have learned in many years of service and repair. If you have suggestions or comments they are welcome.
If you are a homeowner looking to repair your own appliance, understand that the voltages can be lethal, the fuels are highly flammable and high pressures are used. Know your limits.

Пікірлер: 117
@austinharding9734
@austinharding9734 4 жыл бұрын
I LOVE how this vids historical aspect is from a contractors point of view, a much more 1st person or applicable point of view, rather a 3rd person a historians point of view, very informative for a millennial such as i
@auktober
@auktober 10 жыл бұрын
Always entertaining,always informative. Keep em coming. Thanks
@bcjoly
@bcjoly 10 жыл бұрын
I just discover this channel a few days ago. awesome as I am new gas fitter. this helps allot. I am grateful for the time you put in here.
@Adamn7210
@Adamn7210 5 жыл бұрын
Do you know if you can cut b vent. Does both chambers inner and putter carry gas out?
@mayboo9368
@mayboo9368 2 ай бұрын
My guy yesss excellent flawless, perfect video you're the best
@jontopham2742
@jontopham2742 2 жыл бұрын
this is a great video!!!!!!!!!!!!! amazing thank you so much for sharing this valuable information
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Thanks for the thoughts. Our local codes have eliminated most single wall for 80% furnaces. GFM
@deanmartin1966
@deanmartin1966 10 жыл бұрын
Great job. Thanks for posting
@kchest4063
@kchest4063 10 жыл бұрын
Good stuff. We see a lot of C vent coming off the furnace and water heater that turns into B vent at the Y. And you're right, single wall rusts out big time after about 5 years. Thanks again for the videos.
@Adamn7210
@Adamn7210 5 жыл бұрын
Do you know if you can cut b vent. Does both chambers inner and putter carry gas out?
@HN-gj2iq
@HN-gj2iq 2 жыл бұрын
@@Adamn7210 Can't cut B vent.
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Thanks for the support GFM
@targutmarketingllc6146
@targutmarketingllc6146 5 ай бұрын
Great video thanks 🙏🏽
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Thanks for the support. GFM
@lunchspirit
@lunchspirit 4 жыл бұрын
You're a hero.
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
Thanks, but save the hero stuff for the medical staff that are doing for us every day. GFM
@bicycle697
@bicycle697 8 жыл бұрын
thanks!
@ipeteagles
@ipeteagles 2 жыл бұрын
informative. tyvm Sir
@geojor
@geojor 9 жыл бұрын
great stuff, thank you...
@davenichols9539
@davenichols9539 7 жыл бұрын
good video. I'm up north and I'm changing out a 90 plus furnace that was installed in an attic space. with an 80 plus furnace. I know it sounds backwards but the problem is it freezes in the winter. the customer's request is get it the hell out of here! lol anyway like your videos.
@lou1f
@lou1f 6 жыл бұрын
Very common I don’t install 90% in attics because of freezing don’t know any one who does
@cliffordc9497
@cliffordc9497 6 жыл бұрын
Thank you for the video! You just completed a HVAC school assignment for me. Haha THANKS!!
@thegrayhandyman9964
@thegrayhandyman9964 6 жыл бұрын
Welcome GFM
@jimmyandjoannrobbins6580
@jimmyandjoannrobbins6580 5 жыл бұрын
.
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Yes, B-vent. That is the AGA designation. Hope this helps. GFM
@dannyday9547
@dannyday9547 7 жыл бұрын
grayfurnaceman
@GalaXy808
@GalaXy808 10 жыл бұрын
Hey this is new to me,thanks for sharing chief....
@hvac01453
@hvac01453 4 жыл бұрын
great trip down memory lane. I remember everything use to be single wall and B vent.... They've got everyone convinced 90% is the way to go. They cost a lot, and the secondary heat exchangers fail lickety-split. Now exactly what have they saved???? Contractors must love it.
@casketman14
@casketman14 Жыл бұрын
Cheap materials
@workingshlub8861
@workingshlub8861 Жыл бұрын
i have yet to see any of that stainless stuff up here in northeast in all my years doing this....sure i will one day
@ianjohnson2938
@ianjohnson2938 7 жыл бұрын
Hey what would you do for an empire natural gas space heater that will be vented into a masonry chimney that is fully inside my house except for the top 8ft. The chimney is not lined. It used to vent an oil burning furnace directly into the chimney. We now have a direct vent gas boiler venting out an outside wall. Nothing is in the chimney now but id like to put the space heater in it in the basement. I'm in Rhode Island. 2 story home with a full unfinished basement.
@robertr3066
@robertr3066 10 жыл бұрын
I tore down the chimney to the roof line. the chimney was to far gone. I have a Williamson furnace probably from the early 70's. What type of pipe should I use?
@churitomuzhykocastillo6841
@churitomuzhykocastillo6841 8 ай бұрын
Always entertaining Good stuff.this helps a lot, thank you
@believeme5903
@believeme5903 5 жыл бұрын
What about venting for mobile homes, can you explain how it works?
@rodgraff1782
@rodgraff1782 Жыл бұрын
We used to use ABS for condensing furnaces. Was legal in our area.
@grayfurnaceman
@grayfurnaceman Жыл бұрын
I don't believe there is much difference as both must be used with low temp exhaust gasses and are not damaged by the chemicals in the gasses. Some jurisdictions require a specified venting plastic but I don't think it's important. GFM
@gregorymalchuk272
@gregorymalchuk272 5 жыл бұрын
Why were the stainless steel pipes a failure? Virtually nothing will eat stainless steel. Did they make double-walled stainless steel pipe too?
@tuser1750
@tuser1750 Жыл бұрын
@grayfurnaceman, thanks for great content! At 6:48 you mention plexvent, which is the pipe currently connected to my Rheem 80 plus furnace. We bought this house in 2009 and it seems the inspector didn't notice it was recalled years ago😲 I'm wondering what type of pipe I can replace it with so that the furnace can continue venting from the basement sidewall?
@grayfurnaceman
@grayfurnaceman Жыл бұрын
You can probably use B-vent as the manufacturer recommends B-vent as a replacement for flex vent. You will have to have 1" clearance to combustibles. GFM
@pkicng210
@pkicng210 7 жыл бұрын
I can only find B vent and C vent at Home Depot. My furnace was installed in the early 90"s. The original builder used C vents and it corroded like hell. What vents do I use to be in compliance with housing codes? I live in CA.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Some of the 80% furnaces in the early 1990s were installed with C vent. The vent temps were too low and the gas condensed in the pipe. Use B vent from the furnace to the vent pipe. It should work ok. GFM
@roydredge1273
@roydredge1273 8 жыл бұрын
is it ok to use the spray gap filler around B vent going between interior and exterior sidingthis is on a vent pipe for propane water heater
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
It probably is not strictly code. You should have 1 inch air space. GFM
@bucci5678
@bucci5678 3 жыл бұрын
I am moving by boiler and venting out and up the exterior of my house then closing it up. What do you suggest I use to secure the 90 degree elbow and the pipe that runs along the exterior?
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
As the B-vent requires 1" clearance from combustibles, enclosing the B-vent with C-vent (26 gauge single wall pipe) will suffice. GFM
@mfitch5997
@mfitch5997 8 жыл бұрын
Can you use the B vent for a horizontal application? I have a 12 foot span with plenty of clearance for the .25 to 1 foot run.
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
+M Fitch It can be used as a vent connector horizontally if the vent has a minimum 1/4" per foot rise. Higher is always better. Hope this helps. GFM
@jmusicman1973
@jmusicman1973 6 жыл бұрын
M Fitc
@spencerwilliams3385
@spencerwilliams3385 Ай бұрын
G3 gas fitter student (ON, Canada) reading over my code book in prep for final exam. Vent types for natural gas are listed as: A, B, BW, L, BH, C, and direct vent. How on earth did the industry come up with this naming convention and is there a way to remember what each letter stands for? Thanks in advance.
@emeralddragon2010
@emeralddragon2010 3 жыл бұрын
so does that also mean you go down in diameter as well? or is that just for example? i would think you still need the 3 and 4 inch pipe inside diameter? the pvc has much thicker walls than the B or C
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
The diameter is determined by installer instructions and local codes. GFM
@tommy7881
@tommy7881 5 жыл бұрын
I have a carrier unit from about 93 it is installed with 4 inch to 7inch c pipe but it's all rusted and I am tearing it all out... Can I use b vent pipe to reinstall it???
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
Yes, and B vent should have been installed originally. Very common mistake back then. GFM
@kelvinlyons3401
@kelvinlyons3401 9 жыл бұрын
you can install single wall pipe on furnaces 80k btu or better and thing less than that requires B-vent. Can't find it in the book but the inspector says so
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
The single wall pipe issue seems to have legs. The IFGC code gives some cases where single wall can be used with induced appliances. However, field experience tells me to use only B-vent to avoid rustout problems. I will be coming out with a video on vent connector sizing that may help. GFM
@Adamn7210
@Adamn7210 5 жыл бұрын
Do you know if you can cut b vent. Does both chambers inner and putter carry gas out?
@attacknblack1984
@attacknblack1984 3 жыл бұрын
Can you wrap short runs of c-vent with an insulation blanket to stop the condensation?
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
If you are condensating, replace the vent connector with B-vent. GFM
@JasonScottHamilton
@JasonScottHamilton 6 жыл бұрын
I have an 80% furnace and the exhaust connects with b vent. The exhaust connection is leaking hot air back into the furnace and causing it to overheat. There doesn't appear to be any type of sealing between the connection (metal on metal). Should this be sealed with HVAC tape or is there another solution?
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
This does not sound right. There is no need to seal joints because the vent is under negative pressure. My thought is you may have a draft hood equipped furnace that is spilling out the draft hood. Do you notice heat coming from the top portion of the furnace when its on? If so, that is a dangerous condition. You either have a vent blockage or a negative pressure in your house. GFM
@JasonScottHamilton
@JasonScottHamilton 6 жыл бұрын
grayfurnaceman thanks for the feedback! Amazing that you knew something was off. I took another look and the draft actually appears to be caused by a leak from the heater air output (only happens when the blower motor is on) and blowing warm air through the sheet metal joint, right under the draft hood exhaust, next to the inducer. My little closet gets warm and then I get short cycling. Maybe time to call a pro?
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Probably GFM
@r5yamaha
@r5yamaha 7 жыл бұрын
do you have a youtube on venting a hot water tank through the roof?
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I haven't done that one yet. The water heater should have instructions on venting with it. GFM
@GalaXy808
@GalaXy808 10 жыл бұрын
B vent you said?
@c9sus4
@c9sus4 7 жыл бұрын
you mention 1" clearance to combustible on the B vent, is it OK to have insulation around it? Thanks
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
You can insulate it if the insulation is not flammable. GFM
@c9sus4
@c9sus4 7 жыл бұрын
thank you so much for your prompt reply.
@Bigdaddyshaker
@Bigdaddyshaker 3 жыл бұрын
Person at depot told me to use c vent thru the roof with a rubber boot for a gas water heater wonder how long until that burned
@grayfurnaceman
@grayfurnaceman 3 жыл бұрын
I guess the rubber boot would prevent fire, NOT. GFM
@ironwill04
@ironwill04 5 жыл бұрын
What is considered conbustables Joists and subfloor? How do i know if my boiler and hot water heater use different materials?
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
Wood burns. It is combustible. The 2 materials used in natural draft appliances are C vent (single wall) and B-vent (double wall, listing on the side). GFM
@ironwill04
@ironwill04 5 жыл бұрын
@@grayfurnaceman thank you very much. My boiler and hot water heater join right before they exit out of the side of the house into the chimney. Was wondering if there was an easier material to work with like the pvc instead of b vent. photos.app.goo.gl/E13CRUCUHFBvSN7h7
@kevinwiley6376
@kevinwiley6376 7 жыл бұрын
I want to install an old school furnace in my shop, a Lennox G 20 series, 100,000 btuh. I see from your video I need to use B vent. The furnace outlet is 6 inch oval, and wondering if I can reduce down to 3 or 4 inch thereafter. A 2 foot horizontal run will get me through the exterior wall and asking, can I cap it off there, or must I 90 up and go vertically through the roof?
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
You can't reduce the vent below the size of the draft hood connection. You do need a a vertical riser and termination of the vent. GFM
@unti419
@unti419 Жыл бұрын
Will different brands of B vent pipe and fittings work with each other?
@grayfurnaceman
@grayfurnaceman Жыл бұрын
Generally, no GFM
@unti419
@unti419 Жыл бұрын
@@grayfurnaceman Thanks. The roofers broke the flex 90 just below the roof and the flue is at least 25 years old. I'll see what I can find without replacing the entire flue.
@MuzixMaker
@MuzixMaker Ай бұрын
What kind of vent is suitable for exhausting outdoor kitchen/propane BBQ grill through an attic space?
@grayfurnaceman
@grayfurnaceman Ай бұрын
Single wall galvanized 26 gauge pipe. GFM
@MuzixMaker
@MuzixMaker Ай бұрын
@@grayfurnaceman thanks very much for the reply. Is there a building code that governs this type?
@richardlisacki2250
@richardlisacki2250 5 жыл бұрын
Can you put a 4” SS liner in a 6” b vent?
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
That depends on what the use of the vent pipe is. If its for a wood stove, the B vent is not rated for that high of temps. GFM
@richardlisacki2250
@richardlisacki2250 5 жыл бұрын
It is in a b vent chimney that is for a gas water heater. The water heater is the on thing hooked up to the chimney. I use to have a gas furnace hooked up to it, but replaced it with a high efficiency model which doesn’t use the chimney. I was told that going from a 4” vent to a 6” b vent might not be good. A chimney company told me I would have to replace the b vent chimney and they didn’t recommend running a 4” stainless steel liner through the b vent. A water heater manufacturer recommended having a 4 “ vent and not going to the 6”. A liner would be less expensive to put in than a whole new b vent system. But I am not sure if it is legal or not.
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
You can just put 4" B-vent inside the 6" if the vent is straight. You can use a flexible SS inside the existing vent if it is not straight. I would not use the 6" B vent as a vent, but using it as a chase is ok.. GFM
@johnwhite6538
@johnwhite6538 Жыл бұрын
I need to install an oil furnace but I’m not sure what kind of flue pipe to use.
@grayfurnaceman
@grayfurnaceman Жыл бұрын
If you are venting to a masonry chimney, you can use 26 ga C-vent (single wall) for the vent connector. If venting is metal, you will need L-vent. GFM
@johnwhite6538
@johnwhite6538 Жыл бұрын
@@grayfurnaceman no masonry chimney. The vent would travel 2’ from the top of the furnace to the ceiling than 6” through an insulated area than out the shingle roof. So I would use L vent for this? if so do you you know what the clearance to combustibles needs to be for that pipe? I also read that the pipe should be a minimum of 5’?
@grayfurnaceman
@grayfurnaceman Жыл бұрын
@@johnwhite6538 3" clearance to combustibles. Size depends on size of appliance. Never seen anything less than 6". GFM
@fernandosalgado3589
@fernandosalgado3589 5 жыл бұрын
B vent that’s double wall pipe
@hangngoaigiare
@hangngoaigiare 8 ай бұрын
Please do a venting video
@grayfurnaceman
@grayfurnaceman 8 ай бұрын
I have some venting videos but tell me what specifically you want. GFM
@hangngoaigiare
@hangngoaigiare 8 ай бұрын
@@grayfurnaceman everything about venting i guess, cat 1 , to cat 4. Multiple equipments
@grayfurnaceman
@grayfurnaceman 8 ай бұрын
Try this one for cat 1: kzfaq.info/get/bejne/jOCemZSU3d_Hhqc.html@@hangngoaigiare You can find all my videos on venting by going to my channel and typing "venting" in the search engine. GFM
@youcandoitmaybe5909
@youcandoitmaybe5909 5 жыл бұрын
What can I use for my air temp oil furnace 85%
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
If you have a chimney, you can connect from the furnace to the chimney with C vent (single wall 26 gauge black pipe). GFM
@QiuyuanChenRyan916
@QiuyuanChenRyan916 Жыл бұрын
So what does BH stands for?
@grayfurnaceman
@grayfurnaceman Жыл бұрын
Its a single wall stainless steel vent for non-condensing appliances. It is air tight because the vent pressure is positive. GFM
@wesleym.3588
@wesleym.3588 5 жыл бұрын
What is your preference on brand of B vent?
@electriccar3253
@electriccar3253 5 жыл бұрын
I have no preference. All brands pass the same tests. GFM
@williamshaw3rd
@williamshaw3rd 2 жыл бұрын
As I get ready to install my 81% shop furnace bought from NORTHERN Tool.. 🤔
@braddougherty3401
@braddougherty3401 4 жыл бұрын
"Its called B vent because it has a 'B' on it". 🤔🤔🤔🤔😂😂😂😂😂 Classic
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
It also means 1" clearance to combustibles and 550 max temp.. GFM
@natewho4366
@natewho4366 Жыл бұрын
I never see pvc on 80% only 95ers
@grayfurnaceman
@grayfurnaceman Жыл бұрын
The stack temp is too high for PVC on 80% appliances. GFM
@FrankDeLeon-ko9mi
@FrankDeLeon-ko9mi 8 ай бұрын
Too much yap more splat
@Adamn7210
@Adamn7210 5 жыл бұрын
Do you know if you can cut b vent. Does both chambers inner and putter carry gas out?
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
No. But there are adjustable lengths. GFM
@Adamn7210
@Adamn7210 5 жыл бұрын
grayfurnaceman how do you attach it right at the collar of the furnace
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
@@Adamn7210 At the collar and only at the collar, you can screw it to the furnace discharge if the manufacturer's instructions allow it. GFM
@Adamn7210
@Adamn7210 5 жыл бұрын
grayfurnaceman ok so just cut it flush and put right on top of the hole?
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
@@Adamn7210 Yes GFM
The thermocouple compared to the thermopile.
6:01
grayfurnaceman
Рет қаралды 410 М.
Gas Water Heater B Vent
21:00
Plumbing Solutions, LLC
Рет қаралды 120 М.
NERF WAR HEAVY: Drone Battle!
00:30
MacDannyGun
Рет қаралды 57 МЛН
WHO LAUGHS LAST LAUGHS BEST 😎 #comedy
00:18
HaHaWhat
Рет қаралды 20 МЛН
Vent system design for Category 1 appliances
41:10
Ken Delcore
Рет қаралды 6 М.
Water Heater Vent Pipe Inspection Failure and Fix
18:06
KenTraining
Рет қаралды 73 М.
The Most Common Reason Why A Gas Furnace Won't Turn On
8:25
Everyday Home Repairs
Рет қаралды 1,6 МЛН
B-Vent Roof Top Pipe Vent Flashing, Steps 1 & 2
5:15
Exteriors by Gary Whillock
Рет қаралды 89 М.
Fix Your Bathroom Exhaust Fan FAST!
24:20
Home RenoVision DIY
Рет қаралды 1,2 МЛН
Venting for cat I gas appliances
27:56
grayfurnaceman
Рет қаралды 55 М.
Installing Flue Pipe, Leak Testing Gas Pipe For New Heating System
20:35
Тайка и Борщ | Телега "Легенда о Захаре" #еда
0:20
Легенда о Захаре
Рет қаралды 2,6 МЛН
Part 47.Intelligent Bed Furniture Good things Sharing
0:18
FURNITURE FOR DREAMS
Рет қаралды 6 МЛН
ТАМАЕВ УНИЧТОЖИЛ CLS ВЕНГАЛБИ! Конфликт с Ахмедом?!
25:37
Косички из морковки 🥕
0:40
Сан Тан
Рет қаралды 9 МЛН