Understanding and Wiring Heat Pump Thermostats with AUX & Em. Heat! Terminals, Colors, Functions!

  Рет қаралды 558,371

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

This HVAC Video is about Heat Pump Thermostats- the wiring color code, terminal functions, and exactly what happens inside the thermostat as well as what the difference is between the heat, aux, and emergency heat. Thorough knowledge of these functions will aid with troubleshooting procedures to solve problems with the heat pump. Supervision is needed by a licensed HVAC Tech before doing this as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In This Video
UEI DL379B Voltage Tester: amzn.to/3t5Cx8m
Magnet Jumpers- amzn.to/2PyKPQZ
Alligator Jumpers- amzn.to/2PxqJXn
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos/Articles
• Top 12 Problems/Mistak... 10
• Thermostat Wiring Diag...
• Thermostat Wiring to a...
• Thermostat Wiring & Re...
• Thermostat, Furnace, A...
• Thermostat Wiring & Re...
• Heat Pump Thermostat W...
• Wiring a Thermostat, F...
• How to Test a Heat Pum...
• Wiring a Heat Pump The...
• Heat Pump Thermostat T...
• Understanding and Wiri...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #oil #thermostat #problem #top10 #hvacthermostat #hvactips #hvacproblems #thermostats
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 255
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Support and Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is the Link for the newer UEI DL479 Multimeter with temp sensor- amzn.to/2jtsUbJ Here is the Link for the newer UEI DL 469 Multimeter- amzn.to/2jw4ePJ Here is a link to the UEI DL389 Multimeter used in this video- amzn.to/2av8s3q Here is the link for the Irwin Wire Stripper/Cutter/Crimper amzn.to/2dGTj2V Here is the link to the Fieldpiece SDMN6 Dual Pressure Testing Manometer with Pump-amzn.to/2jyK5Ka Here is a link for the Supco Magnet Jumpers amzn.to/2gS4h6z Here is the Link for the Yellow Jacket Refrigerant Manifold Gauge Set used in the videos- amzn.to/2aenwTq Here is a link to Refrigerant hoses with valves used in the videos- amzn.to/2aBumVI Here is the link to the Fieldpiece ST4 Dual Temp Meter- amzn.to/2wc1ME3 Here is a link to the Digital Refrigerant Scale used in the videos- amzn.to/2b9oXYl Here is a link to the Imperial 535-C Kwik Charge Vaporizer for Charging Refrigerant- amzn.to/2wFHtBW Here is a link for RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn Other tool links can be found in the video description section. ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon. Check out other videos on the HVACR topics of interest at- kzfaq.info/love/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
@juneblanche4103
@juneblanche4103 6 жыл бұрын
Honeywell non programmable thermostat with heat pump
@erictofsrud7932
@erictofsrud7932 Жыл бұрын
Out of all the KZfaq videos explaining the wiring, specifically the AUX and Emergency heat wires, you explained it the best. I went 6 years with a heat strip that was not working. Although I'm in Sacramento, it still gets cold at night in the winter, and I never understood why the unit started grinding away all night and not producing heat when the outside temp was below 32. Turned out it was just a 40 amp fuse. Replaced it, and man, that's some good winter heat now, that comes on when there's a 3 degreed spread between the setpoint and the inside temp.. Thanks for helping me understand it's operation!
@sarahfowler1601
@sarahfowler1601 Жыл бұрын
This is my same issue!! Live in sac and if it’s below 40 my heat pump won’t heat the house!!! It was 61 degrees inside the house this morning. I need help
@Oneklickmedia
@Oneklickmedia 7 ай бұрын
I’m also in Sacramento looking up why I’m not getting best heat when it’s reaching 38 degree outside. I reset breaker, clean out contact terminal and clean sensor connection. The heat works but not as hot and was curious what AUX means, now I get it. The key thing is I don’t recall reading “ heat strips” in my manual. I understand heat pump and the valve but never came across heat strip til this video. Is it located in the attic blower? Or outside condenser fan motor ?
@Oneklickmedia
@Oneklickmedia 7 ай бұрын
@@sarahfowler1601did you figure it out? I bought temp radar gun harbor freight and my heat show 90 degrees out the vent. But I’m going to test it during day and I think should be reading higher
@juliocalvet9839
@juliocalvet9839 7 жыл бұрын
thanks for all that you do for all of us out here in the real world
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Glad to help!
@hectorjr.3359
@hectorjr.3359 5 жыл бұрын
Your videos are by far the most helpful. Thanks for your time and knowledge!
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks EZMoney JR.!
@Union53992
@Union53992 6 жыл бұрын
Thank you! I had a new heat pump and thermostat "professionally" installed a few weeks back. Came back from being out of town last night to find that the aux heat (heat strip) didn't work. This was the first time it was cold enough to need it. While waiting for the HVAC company to return my call, I cracked open the manuals for the heat pump, air handler, and t-stat. Having zero HVAC experience, it was still a little confusing. By 3:15 in this video, it was clear to me that the white wire was connected for a conventional system vs. heat pump. I was relaxing in a warm house by the time the HVAC company called back.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Awesome to hear thanks!
@chrismaddox15
@chrismaddox15 4 жыл бұрын
Really nice presentation! Learned a lot! Thanks.
@Pretzel114
@Pretzel114 7 жыл бұрын
Hi ACSERVICETECH! Great video, I drew a diagram and labeled it just like you explained. Excellent work. Thank you!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Awesome, I will have a troubleshooting video on this stat coming up. Thanks for letting me know!
@laurielambert2178
@laurielambert2178 7 жыл бұрын
great video! very informative and easy to understand.Thanks!
@michaelmorassi4953
@michaelmorassi4953 7 жыл бұрын
Great job on all your videos. Very informing..
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thank you Michael!
@imtruth69
@imtruth69 6 ай бұрын
Great information and explanation. That helps a lot. Thank you very much.
@jefferylegere
@jefferylegere 6 ай бұрын
saved my bacon. thank you. last technician left our aux connected to the reversing wire (at the air handler). so when the heat was needed it was just activating the reversing valve thinking it was the heat strips since, from the thermostats point of view, the heat pump wasn't keeping up. With this I was able to get the strips and the reversing valve straightened out. we don't use much heat most winters so this went two years undiscovered.
@acservicetechchannel
@acservicetechchannel 6 ай бұрын
That's amazing!! It's great to hear you found our video was helpful! Thank you for watching!!
@drivewaygarage1561
@drivewaygarage1561 2 жыл бұрын
I added a new thermostat but I forgot to take a picture of the old one with the wires on it so I was lost. I kept blowing fuses but after watching your video I got it hooked up correctly and now it works, thank you very much.
@drivewaygarage1561
@drivewaygarage1561 2 жыл бұрын
OK well I thought I had it hooked up right but it wasn't working once the weather got really cold and I had to call a heating and air conditioning company they came up checked it all out and said I had it hooked up wrong. They hooked it up right and now it works good
@sicosico2485
@sicosico2485 2 жыл бұрын
Love this thing and it is very well made for the price
@DanO181919
@DanO181919 7 жыл бұрын
Another great video... Thanks for all your videos!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thank you very much!
@deloct
@deloct 7 жыл бұрын
Well explained. Thanks for sharing! 👍👍
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thank you very much, always nice to hear from you!
@TriniDB
@TriniDB 3 жыл бұрын
Hey thanks for the video! Question. I know that the E wire will go into the Y2 slot. But if I have a O and a B wire, where will they go? Will the O go into the O/B slot, and leave the B wire out?
@meerscan9101
@meerscan9101 7 жыл бұрын
good video, love the cricket in background
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Yeah isn't that nice, ha ha. I hope it was not too distracting!
@MR-nl8xr
@MR-nl8xr 6 жыл бұрын
refrigeration tech. This whole time i thought there was a cricket outside my window.
@dariusthomas2801
@dariusthomas2801 2 жыл бұрын
I’m in a hvac class and I understand you more
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
I'm glad these videos help connect the dots!
@zesty2023
@zesty2023 3 жыл бұрын
I replaced a honeywell thermostat, and older one with a newer one of the same model. The old one had a jumper between E and AUX but the new one didn't, does the new one need the jumper too?
@MrChevman81
@MrChevman81 7 жыл бұрын
Very helpful, thanks a lot!!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Glad to Help!
@popsmccartney435
@popsmccartney435 7 жыл бұрын
Great job thanks for sharing, will you do one on wiring a heat pump at the air handler and outside unite.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
I may do something like that in the future, thanks!
@denislau5813
@denislau5813 7 жыл бұрын
Brilliant. Denis Lau(Mauritius). A video on how to read and troubleshoot using the electrical wiring diagram of a refrigeration and AC unit.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Ok, yeah that is a good idea. Please give me a bit. Thanks!
@rommelrodriguez6338
@rommelrodriguez6338 5 ай бұрын
Gracias por explicar! Thank you for explaining!
@momol1152
@momol1152 6 жыл бұрын
Great video was very helpful saved me a lot of trouble! thanks
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Mo!
@momol1152
@momol1152 6 жыл бұрын
thank you, you really explained the wiring great so we were able to see what was wrong with ours, the E and Y were reversed so we switched them and now it works great!! your the best repair person on the internet lol
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Glad to help Mo!
@ParadoxEP
@ParadoxEP 2 жыл бұрын
Question does it matter if the main W cable goes into the E or Aux first if they are connected by a jumper?
@bobbenoit1384
@bobbenoit1384 5 жыл бұрын
Thankyou, you made it very understandable! Do you always put a jumper between the aux and emergency terminals? I have a 2004 2 1/2 ton Lennox heat pump. I read somewhere about an emergency heat relay.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Only if you want the heat strips to turn on automatically when the heat pump cant keep up, thanks
@SombraLocs
@SombraLocs 7 жыл бұрын
Another awesome video!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thank you!
@skipper3069
@skipper3069 2 жыл бұрын
Sir, unit without heat strip, thermostat aux and emergency wire is installed can I remove it ? Thank you for all what you do.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Check out other videos on the HVACR topics of interest at- kzfaq.info/love/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
@keithhoward8651
@keithhoward8651 7 жыл бұрын
Great info. Thanks
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks Keith!
@k00k
@k00k 5 жыл бұрын
I have a loosely related question. I have a bonus room over my garage that has its own zone of hydro heating and cooling on an air-handler in the attic. Works great. This bonus room also has hot-water baseboard as a supplemental heat source. Currently, there are 2 thermostats in the room, one for the air-handler, and one that goes to a Taco switching relay in the basement to trigger the furnace and circulator for the baseboard heat (only baseboard in the whole house, rest is all hydro-air). So my question is, can I change to one thermostat in that bonus room? So when I set the thermostat to call for heat it calls to the air-handler and the baseboard?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Yes if you separate the voltage of the two systems with a 12amp fan relay. So the heat signal would power the fan relay and then the power wire for the other system would get connected to the switch in the relay and then go back to the system as a call for heat, thanks
@acservicedaytona386portora3
@acservicedaytona386portora3 7 жыл бұрын
great video.... as always
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thank you very much!
@yeetyeet2099
@yeetyeet2099 2 жыл бұрын
Thank you, helpful
@44thala49
@44thala49 6 ай бұрын
Nice crickets in the background
@djaudioxtc02
@djaudioxtc02 11 ай бұрын
So quick question, in most HP applications the stat controls the fan not the equipment? (ie if you were to jump Y and R you would get heat pump but no fan) unlike a gas furnace setup where if you jump R and W1 you get heat and fan?
@michaelcostello6991
@michaelcostello6991 3 жыл бұрын
How does the blower motor change speed. Is it 2 or 3 different speeds ? I know its control board has G,O,Y connected to it.
@geojor
@geojor 7 жыл бұрын
very practical thank you ...
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Glad to Help!
@skipper9079
@skipper9079 2 жыл бұрын
Question, can I remove the aux and emergency wire, don't have heat trip on my heat pump but aux wire is connected.
@edvas3290
@edvas3290 2 жыл бұрын
I have one of black color in aux, and the other white on E, can I connect together in the WE., in a new thermostat?
@jefferyhicks3678
@jefferyhicks3678 3 жыл бұрын
Very good video! I have a trane package heat pump and a touchscreen trane thermostat and I believe the wiring is incorrect because my auxiliary heat will not kick on when the pump falls behind, the only way I can get the temperature back up is turning the emergency heat on. Any help would be greatly appreciated 🙏
@vroor32
@vroor32 2 жыл бұрын
Switch to smart thermostat (like I did to ecobee) and then go to advanced settings of the ecobee. You can set the thresholds to when heat pump triggers "emergency heat strips"
@RBUNDERDOG
@RBUNDERDOG 4 жыл бұрын
Do you know how to turn off AUX power on Braeburn thermostat
@garnettghost7888
@garnettghost7888 2 жыл бұрын
So, if I wanted to disable the heat function, but leave the cooling. What where would I cut or mess with to disable that?
@osvaldodasilvajunior3346
@osvaldodasilvajunior3346 3 жыл бұрын
I have a straight air condenser and a heat pump air handle they are both rheem ruud, the thermostat is honeywel. Id like to run my heat strips on heat instead of emergency heat. How can I do that? Switch some wires around?
@edmonsonelectric9138
@edmonsonelectric9138 2 жыл бұрын
On a t-6 z-wave Honeywell stat. There's no aux. I usually put in E. Do I need to add a jumper to W2?
@aaronclark1599
@aaronclark1599 2 жыл бұрын
Do I need a Jumper from E to Aux using a Braeburn 5220 T-Stat? I can't find the book, and online don't say.
@mikemc8495
@mikemc8495 5 жыл бұрын
What's your thoughts on Rheem and Ruud. Specifically in southern California if you don't have access to natural gas? I figured it would be better since doesn't get very cold and reversing valve this power heating and cooling . I would love to hear opinion.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Yeah if Rheem or Ruud heat pump reversing valve goes bad it typically still works in cooling mode non powered. Yeah it depends on your exact year round climate for deciding between gas heat or heat pumps, thanks!
@Kupe241
@Kupe241 2 жыл бұрын
Great video thank you! Getting ready to install a new heat pump thermostat for my mom. She has Heat, Cool, and Emer Heat (heat strips in the air handler). So my question is, should the outdoor unit run when Emer Heat is selected or are they mutually exclusive? Again thanks so much!
@denniscreamer9954
@denniscreamer9954 2 жыл бұрын
3 months late to your question. HVAC tech here. In heat pump application both indoor and outdoor units run in COOL, and HEAT mode only. When in EM or AUX mode only the indoor unit will run, unless it is too cold in the home, typically 3° then the unit will turn on both heat pump AND aux heat. Think of it like a fan flowing across a toaster oven. That’s how the EM heat produces hot air, at the cost of electricity. When possible, run heat mode but if this mode breaks run EM heat. Also to note getting an annual or bi annual system check by a professional company to check these modes and the operation to keep you up to date and maintain the system 👍🏼
@offgridwanabe
@offgridwanabe 10 ай бұрын
Can you change the 3 degree differential to 5 as I like to sleep cooler but in the morning I would need to burn resistance heating to gain back the temperature while I want to used the heat pump.
@DrewNutts
@DrewNutts 7 жыл бұрын
How do u jumper a heat pump in cooling or heating at the t-stat to test it?
@DW-vl2wi
@DW-vl2wi 5 жыл бұрын
Connect R and W for heat strips, O/B for heat pump, and Y for cooling. Edit: you probably figured that out by now...
@mw4382
@mw4382 7 жыл бұрын
When i Turn on my heat it blows Cold Air, I put it on Emergency Heat an the house stays at 70. Im Looking at the honeywell RTH7600D I have a Heat pump. Will that Thermostat work?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Before you change the thermostat and if you don't have ruud or rheem then you can take the existing thermostat base off and jump from R to Y to see if your outdoor heat pump will come on. If it does then you know your existing tstat is bad. Yes that stat would work though.
@johnledbetter2274
@johnledbetter2274 7 жыл бұрын
can you show one where I have a gas furnace with a outside ac and also a outside wood boiler that use the gas furnace blower. Right now just switch the fan to auto and on to use outside wood boiler.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
I am not sure when I could put something like this out but I usually just install a second tstat . I then take the R from the furnace and go to the new tstat and then out of the tstat on the W terminal from the stat and power a multipurpose relay with a common going to the c terminal at the furnace. I then go from the r terminal at the furnace to a normally open contact and on the other side of the contact go to the G terminal of the furnace. That turns the fan on. Then I go from the power from the outdoor boiler to the normally open contact on another part of this same relay and power on the other part of the normally open connection to the boiler to turn the circ pump on. Each outdoor boiler is a little different but that is general idea. You need a second tstat and general purpose relay unless there is one for that in the outdoor boiler already for this like in the Hardy.
@samdimmette8895
@samdimmette8895 Жыл бұрын
Mine is set up this exact same way except the black wire is in W1 with the connector piece to W2 and the white and brown wire aren’t in use. Why would the black wire be used in W1 and W2 instead of the white wire. If I’m changing out my thermostat to a nest, would I leave the black wire as W1 in the nest system and remove the connector then still leave white and brown wires in used? Thanks so much!
@edvas3290
@edvas3290 2 жыл бұрын
I have white wire on aux ter/ and black wire un E ter/ .,can connect the two in the letter w / E new thermostat?
@R.L.Thomas
@R.L.Thomas 2 жыл бұрын
I'm switching out an amana t-stat for the pro 3000, maybe a dumb question but my amana has a separate black/brown wire for e heat, do I need to still jump e and aux. I haven't done this in a couple decades and I'm old. I think I don't need a jumper but please confirm for me. Thanks from an old const. superintendent.
@juliorodriguez8863
@juliorodriguez8863 3 жыл бұрын
Excellent thank..!!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Our pleasure!
@jimhoffman937
@jimhoffman937 4 жыл бұрын
Silly question in Florida we use heat pumps versus resistance heating and the heat pump wiring configuration versus conventional. The odd part is my Honeywell has the white wire into aux/E and no other w connections terminated in the existing Honeywell thermostat. However, I am Hooking up to a smart thermostat with a W/E connector I assume that is where I put the white wire as it is really an aux configuration with an Orange o/b setting for the bar? The smart app said my schematic is good and everything seems to work but I don’t want something to happen in the winter when heat turns on lol
@MarcyMckeefer
@MarcyMckeefer Жыл бұрын
In the same boat right now, did you ever figure out the answer to your question here?
@HsingSun
@HsingSun 2 жыл бұрын
Thank you for your video. Question about C wire: Without batteries, how could I see the digit numbers on the thermostat?
@ThatHondaGuy2
@ThatHondaGuy2 8 ай бұрын
Hopefully by now (a year later), you have found your answer, elsewhere; however, in the case that you haven't or for anyone reading and asking themselves the same question.. here's your answer and then some. The thermostat, itself, receives power from the RED (R) wire (24VAC) and the power flows out via the BLUE or Common (C) wire. So, essentially with those 2 hooked up, there is no "need" for batteries. I say that; however, if you have a thermostat that has specific programming/settings/schedules/temperatures set, etc. by all means, keep the batteries in there as a backup source of power. The batteries' purpose is for the simple convenience of retaining all of those settings, within the thermostat, in case the power goes out or you need to flip the main breaker in your house, for some examples. **(Think: alarm clocks. Remember when people used those, instead of their phones or their favorite home assistant to wake up? Oftentimes, most people would keep a battery installed in the alarm clock, in addition to having it plugged into a wall outlet, in order to keep the time and alarm(s) saved, in case of an unexpected power outage.)** Further, regarding the particular model featured in the video, a Honeywell Pro 3210, perhaps, it's a simple and basic thermostat that is pretty straight forward and has standard modes 'n' settings. If you have one of these, as I do, you already know. The most advanced you'll get on that model, is programming your thermostat to match your system type, setting the cycles per hour (CPH) of the Emergency (E) and Auxilary (Aux) Heat, the Compressor startup wait time (default: 5 mins, though 3 mins is satisfactory) and if you want your temp to read in Fahrenheit or Celsius (fun for a quick laugh, as I did this once and watched as my wife looked at me, puzzled, as the thermostat read "23" (Celsius) in the summertime). If you're still reading, there are also some basic system tests you don't have to be an HVAC tech to run through, if you're also a DIY'er and like to run through your own system maintenance checks in between annual tech visits. I hope this helps somebody out there. I'm not an HVAC technician. Just a guy, with a mind and a passion for mechanics and anything that has moving parts. God Bless!
@avm5717
@avm5717 7 жыл бұрын
👍 Great video. video request on the honeywell redlink thermostats.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
I will see what I can do. Thanks for the video idea!
@dhguard1
@dhguard1 7 жыл бұрын
thanks for all your videos,I have learned a lot from you.I have a request if is possible to do a video on programing 5000 and over Honeywell termosthats, I installed a heat pump a few days ago and it gave a headache.Thanks again Ruben
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Ruben, thanks for letting me know what you would like to see!
@dhguard1
@dhguard1 7 жыл бұрын
programable termosthats, which numbers are for compressors delay, degrees Fahrenheit and celcius,heat and cooling,limit tempeture in heat and cooling. thanks again.
@jayhvac4474
@jayhvac4474 3 жыл бұрын
I was trying to upgrade a heat pump thermostat today for a customer and I had everything wired the same way as usual. Once I started the system in cooling the heat pump started running in heat mode. After trying multiple things nothing would change. I then installed the old thermostat and the system went back into cooling mode once again. Any ideas of why this would happen? Any input on this would be helpful.
@chrisclayton584
@chrisclayton584 2 жыл бұрын
I have a whirlpool pump. I have the blue common, orange O, green, red, yellow Y. now my question is I have a white that goes to W2. I was told to connect this to the "E" port on a new Honeywell thermostat not the W2 port. Do you think that's correct?
@nickhoward3746
@nickhoward3746 5 жыл бұрын
Where do you check low voltage at the air handler or package unit without a common from the thermostat? Do you just use a common some where in the unit? Say I'm trying to see if the O terminal is energized without a common from thermostat on a package unit for example. Appreciate all your videos and knowledge!
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
You would measure it with the common at the indoor unit air handler, thanks
@davemurray7117
@davemurray7117 5 жыл бұрын
Great video. Is there a way to have the heat strip turn on when the unit goes into defrost mode so it doesn’t blow cold air into the ductwork? Or have heat strip turn on continuously when thermostat is calling for heat and recirculating fan is running.?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
The heat pump has a 24v output W wire that is supposed to go to the heat strips to turn them on during defrost. It isn't done via the thermostat but from the outdoor unit to the indoor unit, thanks
@shernpin2
@shernpin2 2 жыл бұрын
I live in a basement i kept telling the landlord its blowing cold air and at times its smell like fumes coming out of the vent..dont know why but we kept having heated arguments over this same problems. Do u know why that happens
@gr8mikeY
@gr8mikeY 5 жыл бұрын
I have a 4000 series honeywell thermostat with the same exact wire connection configuration that you show in this video. I am replacing a trane thermostat that quit working. Question I have is that I have a white wire and an X2 wire. From what I have been able to find out looking around online is to connect white wire to AUX and tape off the X2 wire. Is that correct?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
It depends on what type of system you have and what type of heat and auxiliary heat it has. What does it have?
@Ziflinz
@Ziflinz 6 жыл бұрын
We've got a Rheem Dual Fuel system with an outdoor sensor and I'm trying to switch to a newer (TH8321WF1001) thermostat. The previous one has S1 and S2 connections, but the new one has two S1 connections? Is that a problem or should I just connect the two previous wires to the two S1 terminals? Thanks and great video!
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
The S1 and S1 are for indoor or outdoor sensors so yeah you can connect there and then enter programming to let it know that these are for the outdoor sensor, thanks!
@Bluezhealer
@Bluezhealer 3 ай бұрын
So the majority of Heat pumps use the O terminal on @ the thermostat with the reversing valve being energized in the cooling mode keeping the refrigerant flowing normal direction correct?
@IPING4U
@IPING4U Жыл бұрын
Excellent explanation, thank you. I have RH and RC tied together. Can you explain that? Actually I have the red wire on RH and it's jumpered to RC. White on W Yellow on Y Green on G Black on C Orange on O White on W
@TruckManVFL
@TruckManVFL 5 жыл бұрын
What does the blue wire go to. I have a Goodman heat pump with heat strips. Has soon as the temp is set one degree higher the indoor temp drop down so that it makes Aux heat come on. Im trying to make sure things are wired right.y contractor left a mess.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
It sounds like the heat pump is not coming on or is not working properly and electric resistance is all that is heating, thanks!
@seanmcdermott5718
@seanmcdermott5718 6 жыл бұрын
A.C, could you do a video for for a Honey Well 6000 for heat pump mode ?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
I am typically using 5000 and 8000 version but it is possible if I run into one, thanks
@anthonysuau5437
@anthonysuau5437 5 жыл бұрын
Can you do a video on wiring variable speed air handler to a single stage condenser. Using a 2 cool thermostat? Please
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Anthony, thanks for letting me know what you would like to see! Anthony, you would just jumper 1st and 2nd speed in the thermostat together and run one wire out for cooling to the air handler and single speed ac unit, thanks
@fvfgx
@fvfgx 7 жыл бұрын
thanks!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Glad to help!
@ericb.8119
@ericb.8119 13 күн бұрын
My thermostat has a wire going into the B terminal but I do not have a Ruud or Rheem hvac unit. I have a Oxbox Heat Pump system. Is this normal? There is no wire going into terminal O on my thermostat as well.
@CakeHopper1
@CakeHopper1 4 жыл бұрын
Hi AC Service tech: How does the thermostat control the fan speed theough the green wire? Does it change the voltage level or does it use a pulse width modulation (duty cycle) to achieve this?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
G will only power one speed but if the board also recieves a signal on the y then it will move to the higher speed. A modulating air handler or furnace will control the variable air speed via the control board, thanks!
@CakeHopper1
@CakeHopper1 4 жыл бұрын
@@acservicetechchannel Thank you!
@SombraLocs
@SombraLocs 7 жыл бұрын
Can you do a video on Hot Surface Ignitors and troubleshooting a Smart Valve?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
I will be doing hot surface ignitors very soon and smart valves possibly a litttle later. Thanks!
@jonbergstrom2034
@jonbergstrom2034 4 жыл бұрын
Thank you for the video. I have an older York heat pump and York furnace. After installing my new honeywell tstat the system cycles on and off very frequently. It really annoying. This shows the thermostat wiring, but where should these wire land at the heat pump and furnace. I think whoever wires those did it wrong. How do you wire the "system" from to tstat to heat pump, to furnace?
@Titus357
@Titus357 3 жыл бұрын
As for wiring, does furnace kick on in emergency mode; and also when you up the temperature desired by 5 degrees? Fast cycling, see the install manual for checking and/or adjusting thermostat's cycle rates.
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 3 жыл бұрын
The retail (RTHXXXX) Honeywell thermostats generally don't offer any kind of temperature hysteresis/swing/cycle per hour adjustment setting, the cycle rate is fixed at 1*F I generally find that's pretty reasonable but prefer a wider swing at the expense of "comfort" in favor of economy, as you describe. Reduced cycling is also easier on the equipment due to reduced startup cycles and slightly longer run times. The FocusPro (THXXXX) versions do have a cycle per hour adjustment feature which offers some degree of control. These are the pro contractor versions, not the retail versions. These pro versions also offer some adjustability for when aux strip heat is energized (econ/comfort). I'm not sure if this also applies to the higher end Honeywell retail thermostats but it might.
@goin2cali420
@goin2cali420 7 ай бұрын
Going from this exact thermostat to a Honeywell smart thermostat. Anyone know how I would wire the new 1? New to this and kinda confused.
@mark.r8900
@mark.r8900 6 жыл бұрын
hi, so with AC there's a coil above the furnace. with a heat pump, is it the same coil above the furnace? or something else? i am referring to a heat pump and a forced air furnace pairing. thank you.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Yes it is the same. The txv or piston allows a bypass for the refrigerant so it does not get metered in that direction. Have you looked at each of the videos in the "acservicetech refrigeration cycle playlist"? There are some that talk about the heat pump cycle, thanks
@danielfolsom1230
@danielfolsom1230 6 жыл бұрын
I have carrier heatpump model 50VT-48---30TP. The thermostat was honeywell TH522OD1029 with 6 wires hooked up to it.The wires were R=red Y=yellow C=white O/B=orange G=green AUX=blue AUX+E = Orange wire jumper. The R and RC jumpered also the E and AUX jumpered. I installed a ecobee 4 smart thermostat it would not allow E and AUX to jumped. I put my aux wire on the w1 on my ecobee4 . My question is will the new thermostat go into defrost mode in the winter like the old one did. Thanks
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Defrost has to do with the control board outside which will then send a signal to the indoor air handler auxiliary heat. If you didn't change the air handler low voltage wiring then it should be the same, thanks
@danielfolsom1230
@danielfolsom1230 6 жыл бұрын
Thank you this makes me feel much better and love the vids.
@guyinpajamapants6892
@guyinpajamapants6892 3 жыл бұрын
Bosch also uses “B” for power during heat mode.
@nh4759
@nh4759 2 жыл бұрын
So does Mr. Cool universal series.
@nh4759
@nh4759 2 жыл бұрын
What happens if you miswire O for B? Can that cause squealing?
@breekthezeek6547
@breekthezeek6547 4 жыл бұрын
Do you have e into aux and why?
@davidblack8136
@davidblack8136 4 жыл бұрын
I received a Powerly Thermostat and wireless controller from AEP of OHio and am wondering about the thermostat wiring for my all electric house with a heat pump and auxillary furnace.Most wires are clear to me as they are plain to view and correlate to all thermostats I have ever installed. My problem is there is eight wires of which seven were connected to the old thermostat via a simple color coded hookup. On the Powerly thermostat there is no color code. THere is only designation of lettering. O,B, W1,W@ RH,RC, C, Y1 or Y, Y2, and G. The housing shows one(left) hookup of W1 and W2 on one side and O/B and AUX on other side of left. W is O/B and AUX is W2. On the right if RH/RC, C, Y, Y2, and G. Like I said, I have eight wires of which seven were on the old digital thermostat. I've got 6 hooked up and the last one is blue on the old thermostat so where does it go on the new wireless on by Powerly? Any ideas?
@drummerdem50
@drummerdem50 7 жыл бұрын
Thanks
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks for your Comment Drummer!
@wilsq30
@wilsq30 4 жыл бұрын
I have an older Goodman GPG13240701 heat pump paired with a braeburn 1200 thermostat. My heat pump won't stay on. I took the thermostat off to see the wire hookup, there are only 4 wires, Red (R), Green (G), Black (E/W1), and Yellow (Y1). Outside the thermostat wire into the heat pump circuit board does not have a black wire. It has Red, Yellow, Orange, White, Green, and Blue (not connected). Is the thermostat wired incorrectly?
@fret2fret221
@fret2fret221 3 жыл бұрын
So if you were wiring a RUUD/RHEEM would you connect the orange wire to “B”?
@aaronshoyt
@aaronshoyt 3 жыл бұрын
Yes.
@toupsclassroomtoupsclassro9557
@toupsclassroomtoupsclassro9557 3 жыл бұрын
question: can you just jump the red wire and give power to the C
@jimmyung3212
@jimmyung3212 7 жыл бұрын
Hi can you do refrigeration cycle in heat pump? Thanks.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Hey Jimmy, do you mean like this or while in front of a live unit? In this video I go over a heat pump cycle in ac and then in heat mode - kzfaq.info/get/bejne/aKeYrcxiupbKiZ8.html
@jimmyung3212
@jimmyung3212 7 жыл бұрын
If you could show in a live unit with cooling mode and heating mode. How does the reversing valves work thank you so much.
@jimmyung3212
@jimmyung3212 7 жыл бұрын
Sorry i over look. I found your tutorial on heat pump cycle thank you.
@sissymurphy9620
@sissymurphy9620 7 жыл бұрын
do the wifi work the same I have a lennox heat pump put in 2014 with the wifi and so far 2 times this week no heat again monday it was fixed and again it is wednesday no heat and thermostat is black and they said the first time it was a fuse
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
If it is a 24 volt 3 amp or 5 amp fuse blowing then they would need to either look at the additional field installed relays adding up to too much amperage or change out the thermostat wiring from the unit to the thermostat because a power wire is touching the common intermittently, or it could be the thermostat, or it could be sensor wires shorting on the cabinet. Here is a video on the exact subject. -- kzfaq.info/get/bejne/oJ14mK9yv7y4qqc.html
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
It is wired in roughly the same way from the thermostat to the unit normally depending on the way the reversing valve is powered. It is just the internet control that is different. -- kzfaq.info/get/bejne/nKx8kr2E0Ke-fWQ.html
@JulesBartow
@JulesBartow 6 жыл бұрын
That yellow thing to the right, is that a Dimethoxyethane DMM? You mention wires touching... wouldn't a volt meter be a great way of showing relays and solenoids energizing?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Here is the video with that setup while using the multimeter. I just happened to split one long video up into two smaller chunks. Sorry I didn't use it in that one, thanks Jules- kzfaq.info/get/bejne/fsuegrqGqb6cgIU.html
@shernpin2
@shernpin2 2 жыл бұрын
Can a landlord put anything inside the pump they have upstairs. Or set the heater on a timer to go lower and higher
@popsncracks9108
@popsncracks9108 7 жыл бұрын
I have 7 wires inlude brown color. Where is that go? Thanks
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
That depends on where the brown is installed in the air handler. Check this video out - kzfaq.info/get/bejne/nKx8kr2E0Ke-fWQ.html
@sneakyquiet414
@sneakyquiet414 5 жыл бұрын
Can you make video wiring booster fan to furnace blower or from thermostat wiring
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Hey Trevis, we usually don't install a booster fan but we redo the ductwork to distribute the airflow better, thanks
@xrayneoo
@xrayneoo 7 жыл бұрын
Can the common wire be jumped with the red wire to eliminate batteries? Can the green wire be switch to be common at the thermostat and control board to install a smart wifi thermostat like the Nest? two different scenarios.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
C to R would short the transformer or blow the 3 or 5 amp fuse. You need a load between r power and c common to power the load, otherwise it is a direct short. You certainly could take out the fan option and just use this as the common instead if you switched that wire at both the tstat and control board, thanks
@DW-vl2wi
@DW-vl2wi 5 жыл бұрын
To answer your question: The moment R and C are connected at the T-stat terminal bus the T-stat has 24v coming in from R and staying powered by C. The batteries are in to help save the program in case of power loss.
@EddieSportRoberts
@EddieSportRoberts 6 жыл бұрын
I have Senville heat pump. It don't come with a thermostat so i'm assuming buying one of these thermostats won't work with mine. Am i right? Do anyone know how i can limit my aux heater from coming on? I want to be able to use a switch to control it on and off. Senville 12,000 and 18,000 Btu Aura series. I think they are made by Mitsibishi.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
These types of thermostats will not work with mini split units, thanks
@EddieSportRoberts
@EddieSportRoberts 6 жыл бұрын
But there still must be a way for me to control when i want the aux heater to come on or stay off.
@noevirgen15
@noevirgen15 5 жыл бұрын
I have a question my hvac lennox in emheat is not heating that could be
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Maybe the electric resistance has broke, the thermal overload tripped, sequencer could be bad or no low voltage to the sequencer, thanks
@hollyyeh1591
@hollyyeh1591 6 жыл бұрын
I need the help of all your experts, every time I take the temperature up and down due to the change of the weather, and then my heating unit is not working. What I want to know is the air handler or heat pump compressor problem. The technician can only work is replacing the "fuse". But one month later, it happened again and again. Technicians only change the fuses again and again. Any help would be appreciated.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
If they are changing the low voltage fuse over and over but it is intermittent and don't know the cause, just take one thing out of play at a time. Replace the tstat wire going to the thermostat. See if it happens again. Then replace the outdoor tstat wire, wait, replace the tstat, wait so on and so forth. Unfortunately intermittent problems are rough and we can only fix it if we can see the problem. The rule is though, don't just do the same thing over and over. Try something, thanks
@ronniebuchanan6575
@ronniebuchanan6575 2 жыл бұрын
Tempstar powers in heat mode. Caught me by surprise. &&
@DynoSauR4Truth
@DynoSauR4Truth 5 жыл бұрын
I just bought a new Honeywell RTH 9585 thermostat to use with my Trane heat pump which is all electric. it also has Aux heat and Emergency heat on the original Trane thermostat. Why do Honeywell thermostats not have an individual W connector? Which has the white wire hooked to it on the original thermostat? My new Honeywell has a combination O or W connector and I contacted Honeywell and they said to put the O=Orange wire to that terminal and put the both the White and the Black wires to the single Aux/E connector.
@TyWerks
@TyWerks 3 жыл бұрын
I have the same issue did you have any issue after putting them together?
@DynoSauR4Truth
@DynoSauR4Truth 3 жыл бұрын
@@TyWerks No, it's been working fine for over a year now.
@Bobster0007
@Bobster0007 5 жыл бұрын
is the common wire considered the "ground" or "neutral" wire?
@kevinmurray3945
@kevinmurray3945 5 жыл бұрын
"Common" here relates to the 24-volt transformer. "Neutral" relates to the white wire of the 120-volt circuit; functionally they are somewhat the same, but should not be confused with each other.
@peterphanh203
@peterphanh203 6 жыл бұрын
I have a brown and black wire too. Where do they go? Please help.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
They may be attached to an outdoor temp sensor. I would turn the power off to your indoor furnace or air handler and check to see where they are connected to or if they are wire nutted there and go out the the outdoor unit. If you see what they are connected to then let me know, thanks
Heat Pump Wiring Basics (Universal Principles)
15:45
Jersey Mike HVAC
Рет қаралды 30 М.
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 31 МЛН
УГАДАЙ ГДЕ ПРАВИЛЬНЫЙ ЦВЕТ?😱
00:14
МЯТНАЯ ФАНТА
Рет қаралды 3,3 МЛН
KINDNESS ALWAYS COME BACK
00:59
dednahype
Рет қаралды 164 МЛН
New model rc bird unboxing and testing
00:10
Ruhul Shorts
Рет қаралды 23 МЛН
Thermostat Wiring Explained!
10:35
Benjamin Sahlstrom
Рет қаралды 960 М.
Install Your Own Electronic Heat Pump Thermostat
10:50
Pilot View Productions
Рет қаралды 28 М.
2 Stage Heat Pump Wiring
8:13
Jersey Mike HVAC
Рет қаралды 7 М.
How an Air Handler & Heat Pump Work & are Controlled by 24v Thermostat Wires!
19:29
Thermostat Wiring
7:13
David Jones
Рет қаралды 2 МЛН
Nest Heat Pump Wiring Diagram:  How To Wire Nest With a Heat Pump
10:17
One Hour Smart Home
Рет қаралды 214 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 22 М.
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 1,8 МЛН
HVAC Low voltage control wiring (Basics For Beginners)
11:27
Jersey Mike HVAC
Рет қаралды 220 М.
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 31 МЛН