Using a HP 8477A Calibrator to test a HP 432A Power Meter

  Рет қаралды 2,515

tgsoapbox

tgsoapbox

Күн бұрын

I just got my gear back from Keysight where they cal'd it so now I'm able to check out some of the power meters that I have. Next step will be to test the power references on the 8902A etc.

Пікірлер: 13
@PapasDino
@PapasDino 5 жыл бұрын
Good on Keysight for still supporting this gear which I'd imagine is actually still used in many shops. What was the magnitude of what they got for doing that for you?
@tgsoapbox
@tgsoapbox 5 жыл бұрын
All up, between the 3458A, 8477A & 432A-H76 it was around $2.5K but it is important to get these things checked when you buy them off eBay - I don't think I'll be doing that yearly as I don't need traceability. I'll do a standards cal on the 3458A every 3 years to see how it is drifting though.
@davidv1289
@davidv1289 5 жыл бұрын
Interesting video, thanks for sharing. I'm not sure I understand the difference between open circuit and closed circuit meters, is that a difference between thermistor sensors and diode sensors ?
@tgsoapbox
@tgsoapbox 5 жыл бұрын
Yes - The 8480 series sensors are basically "open" in the sense that they need the power reference to set the measurement (The 'open loop' designation is a play on control theory with the 'open loop' systems needing a stake in the ground to work). "Closed" ones are like the 478A Thermistor which can make a measurement directly without referencing it to another value.
@davidv1289
@davidv1289 5 жыл бұрын
Thank you for the reply. I've used power meters for many, many years as a radar technician - almost exclusively the diode sensor type - and never noticed the (now) obvious difference between the older thermistor mount meters and the newer diode meters - no calibration source on the thermistor meters! There is no need to "calibrate" the thermistor sensor before use. Still learning ! My choice for my retirement bench was the HP 437B with a 8482A and a 8484A sensor.
@georgeveropoulos2489
@georgeveropoulos2489 Жыл бұрын
hi very nice! i want to ask you in any new meauser the power meter must calibrate ?
@tgsoapbox
@tgsoapbox Жыл бұрын
If the meter is new, then typically all you need to do is to confirm that it passes the operator check (assuming that the manufacturer has included a calibration step in its production). If you want to be very sure or the meter is second hand, then you'd run it through its performance checks. If you've done any work on it, then you should run it through the adjustments process before use.
@w8biatvrepeater638
@w8biatvrepeater638 3 жыл бұрын
I am wondering why, when you started, you did not initiate the fine zero switch as the meter movement was starting below zero?
@tgsoapbox
@tgsoapbox 3 жыл бұрын
I must have missed doing that as you're supposed to when using the 432A.
@tgsoapbox
@tgsoapbox 3 жыл бұрын
Actually, just looked at the video - Are you talking about the zeroing at the start of the video around 2:24? If that is what you're referring to then this action isn't part of the test when using the 8477A calibrator - Using the zero knob on the calibrator takes care of that operation. Fine Zero is an automatic control that helps keep the bridge balanced when RF power isn't applied.
@TheDefpom
@TheDefpom 5 жыл бұрын
Noticed the needle is twitching around a little on the first test, I wonder if one of the controls are a bit dirty? Probably the calibrator output, due to the voltmeter jumping around a bit too.
@tgsoapbox
@tgsoapbox 5 жыл бұрын
I think it is my radio mic - I noticed the needle not moving when I was quiet.
@danishnative9555
@danishnative9555 5 жыл бұрын
You have been conspicuously absent lately. Must be playing rugby with the schnauzers.
RTO2000 Oscilloscope Repair DRAM Diagnostics
4:09
jjoonathan
Рет қаралды 507
Bench testing an Agilent E3620A and E3610A power supply.
12:56
Craig Petersen
Рет қаралды 430
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 13 МЛН
A little girl was shy at her first ballet lesson #shorts
00:35
Fabiosa Animated
Рет қаралды 10 МЛН
RTO2014 Repair Part 1
23:31
jjoonathan
Рет қаралды 1,3 М.
OPENING MY BALUN WAS NOT EXPECTING THIS INSIDE
11:08
IZ0MTW
Рет қаралды 421
Advanced Energy Cesar 136 RF Power Generator (A# 80666)
0:46
Bridge Tronic Global, Inc
Рет қаралды 60
Agilent E 4433 B ESG D Series Signal Generator (A# 68853)
4:55
Bridge Tronic Global, Inc
Рет қаралды 89
Agilent 81640 A Tunable Laser Source Module (A# 68267)
0:45
Bridge Tronic Global, Inc
Рет қаралды 18
July New Arrivals
0:55
Alltest Instruments
Рет қаралды 136
TRAP ROTATABLE DIPOLE VS END FED RANDOM WIRE
0:55
IZ0MTW
Рет қаралды 190
Я обещал подарить ему самокат!
1:00
Vlad Samokatchik
Рет қаралды 1,6 МЛН
Todos os modelos de smartphone
0:20
Spider Slack
Рет қаралды 62 МЛН
Сколько реально стоит ПК Величайшего?
0:37
S24 Ultra and IPhone 14 Pro Max telephoto shooting comparison #shorts
0:15
Photographer Army
Рет қаралды 9 МЛН
iPhone, Galaxy или Pixel? 😎
0:16
serg1us
Рет қаралды 1,3 МЛН