You would think in this day and age Vauxhall would have learned something from the past with there heater fan fires, another good video sandy and co 👍
@matejanosvarga88772 жыл бұрын
Great vid Sandy:) Seems like the world's only car where the heater matrix is easier to replace than the blower fan.
@mrautoservices73542 жыл бұрын
Great diagnosis enjoyed watching
@mikeberry3042 жыл бұрын
Cheaply made connectors , not upto the job Sandy , cant beat soldered wiring , heatshrinked, top job sir 👍👍
@sandyande2 жыл бұрын
Cheers Mike
@stephenjohnson59852 жыл бұрын
Had same on a Peugeot 208 the other day(same plug fault).
@philipscott11282 жыл бұрын
I can see plenty of horror stories emerging from these Stellantis cars, in the future. Wet timing belts being one of them
@the_retired_mechanic2 жыл бұрын
Sandy the motor is breaking down and pulling too much currently intermittently. The weak link is that connector. Put a 25 amp fuse in it to protect the cables and it will blow it in the future. Then new motor time.
@sandyande2 жыл бұрын
Cheers my friend I'll inform the customer, Sandy
@Alanw742 жыл бұрын
Strange the dealer wouldn't just say the fault is with the plug and that's why they stock the new motors. Good diagnosis tho. What autel are you using?
@sandyande2 жыл бұрын
It's an old model Autel ms905
@larrysimon12 жыл бұрын
Jeszooooooooooo 40 amps draw on a blower motor ? Something wrong there mate.