Victron Energy 3000va Inverter Chargers | MultiPlus

  Рет қаралды 16,233

Unaka Gear Co.

Unaka Gear Co.

4 ай бұрын

In this video, we compare and contrast the ‪@VictronEnergyBV‬ MultiPlus-II 24V and 12V models with the original 3000W 12V MultiPlus.
The Victron Energy MultiPlus range is renowned for its reliability and performance in off-grid and backup power applications. In this video, we break down the differences between these models, helping you choose the right one for your specific needs.
Discover the enhanced features of the MultiPlus II models, including improved efficiency, advanced battery management, and expanded input voltage range. Compare these with the original 3000W 12V MultiPlus, which remains a solid choice for many applications.
Whether you're powering a conversion van, off-grid cabin, or boat, understanding the differences between these models is crucial. Join us as we delve into the specifications and capabilities of each Victron Energy MultiPlus Inverter Charger, empowering you to make an informed decision for your power needs.

Пікірлер: 33
@tjdalyvideo
@tjdalyvideo 5 сағат бұрын
Thank you! Very helpful
@davidpatrick1813
@davidpatrick1813 4 ай бұрын
thanks ... I have the middle unit and very happy with it
@unakagearcompany
@unakagearcompany 4 ай бұрын
Great to hear!
@davidpatrick1813
@davidpatrick1813 4 ай бұрын
by the way, I think a real winner video would be to show how to set up the unit to only charge between or during the time that our local power rates are lowest. There are a million different things it can do .. but If there is sun to power panels, I want the unit to use it, if not ... not turn on shore power and charge except during the low rate hours. If it turns on and charges during the day (which is fine) it want to ... even when sunny until full ... I want the best from all worlds :-) ... later.. @@unakagearcompany
@simon359
@simon359 4 ай бұрын
If you’re off grid with the Quattro, but you’re connected to the main panel, so you can power your house. Using an interconnect switch, when you turn off your inverter and only have it set for charging, can you plug it into your house outlet to charge? I’ve done this and haven’t had any issues - just wondering if this is safe?
@unakagearcompany
@unakagearcompany 4 ай бұрын
Hard to say without seeing or knowing more about your system. Feel free to email us at CSR@unakagearco.com or give us a call and we can talk through it!
@jgpjanssen1924
@jgpjanssen1924 4 ай бұрын
I have 8 panels 450wp, 50v at 10A. When i use 2 panels in serie and 2 paralel (100 V at 20A). I can make 2 sets. Do i use the victron mppt 100 / 30 or the 100/50. Because the output make 50amp? Oh yeah, thx for the video
@davidpatrick1813
@davidpatrick1813 4 ай бұрын
There are some interesting testing but whatever the case always keep it under the 100V or whatever the MPPT controller is. The volt in is key. Some have tested and the charge watts/amps is much more tolerant and also adjustable in the Victron eco system.
@unakagearcompany
@unakagearcompany 4 ай бұрын
Thanks for the question. Typically the 100/30 is good for up to 400watts of solar when charging a 12v battery bank. The 30 in 100/30 tells us that we can charge the battery bank at 30 amps. If we have 30 amps to work with at 12 volts that means we can utilize roughly 360 watts (12v x 30amps = 360watts) of solar. When wiring your solar panels together it is important to note that you want to stay close to 10 amps and you need to stay well within the voltage limit on the charger (100V). When you exceed 10 amps you may need to need to run larger wire to safely handle the current and exceeding the voltage limit will fry your charger pretty quick. Blue Sea Circuit Wizard is your friend in situations like this.
@coppocop7089
@coppocop7089 3 ай бұрын
I have a Victron energy multi plus 24v 3000 70 amp. I’m wanting to connect my phone what do I need also what else would I need for solar panels please?
@unakagearcompany
@unakagearcompany 3 ай бұрын
If you want to see your multiplus on your phone you either need a Cerbo device, or the cheaper option would be to install a VE.Bus Smart Dongle. It connects to your multiplus using a RJ45 cable. I included a link below. To add solar to your system you will need a MPPT charge controller + solar panels. If you email us at csr@unakagearco.com we can answer more questions or make specific recommendations on what charge controller you need based on the amount of solar you are trying to add. unakagearco.com/products/victron-ve-bus-smart-dongle-ass030537010?_pos=1&_sid=c2cde4c30&_ss=r
@mjbastian3677
@mjbastian3677 3 ай бұрын
Is the victron energy multiPlus II 12/3000/120-50 a split phase system?
@unakagearcompany
@unakagearcompany 3 ай бұрын
The Multiplus II 12/3000/120-50 is not a split phase system on its own. You can install two units in parallel to create a split phase system. The MultiPlus-II 2x 120V unit can do split phase output but only if it has split phase input. It can not generate split phase with a single 120V feed, or off of battery power. Feel free to contact us or email us at CSR@unakagearco.com if you need help with your system.
@gab4112
@gab4112 Ай бұрын
Its good sor sump pump back up or its to much ? I have a ½ hp red lion 5.1 amp whit peak of 10amp. I will plug it whit a groupe 31 deep cycle battery
@unakagearcompany
@unakagearcompany Ай бұрын
It should handle the sump pump at the loads you listed.
@Lake2Lake
@Lake2Lake 4 ай бұрын
how successful are these at running a single Air Conditioning unit? I currently have a 30 amp RV travel trailer.
@unakagearcompany
@unakagearcompany 4 ай бұрын
They work well. Your typical RV AC unit will usually require something in the neighborhood of 1500 watts to run and the 3000va inverter can supply that wattage without an issue.
@peeinginthewind
@peeinginthewind 3 ай бұрын
@@unakagearcompanyeven the surge ?
@unakagearcompany
@unakagearcompany 3 ай бұрын
@@peeinginthewind It depends on the Air conditioner but the surge typically is not a problem. If there was any concern or issue, you could always install a soft start or smart start with the AC unit to reduce the in rush or surge.
@Upliftyourbrothers
@Upliftyourbrothers 2 ай бұрын
Some 100ah 48v batteries I have heard have a hard time starting them, something to do with the BMS in the cheapest eg4 lifep04 battery. I’ve not tested, only repeating what others have said. The higher quality eg4 and sok seem to do it no problem.
@STRUTZKOFF
@STRUTZKOFF 4 ай бұрын
ac2 out is programmable it can be used off grid
@unakagearcompany
@unakagearcompany 4 ай бұрын
Thanks for the reply. Please tell us more.
@junkerzn7312
@junkerzn7312 4 ай бұрын
Hopefully Victron will update their line-up. Its a real mess. Their charge controllers are awesome, the pure inverters (the phoenix line) are quite good too. But the DC-to-DC chargers, the DC-to-DC converters, and their inverter-chargers are all just way out of date. The inverter-chargers are solid units for what they do, and the warranty is great, but the technology is just way too old. For example, their 48V multiplus II doesn't even have split-phase output. To be honest, I'd use an EG4 6000XP over a Victron multiplus II for 48V.
@unakagearcompany
@unakagearcompany 4 ай бұрын
Thanks for the input. I suspect you'll see your ideas come to fruition sooner than later. Victron may be late to the game on the single split phase unit but when they get it to the finish line it will be the standard.
@mtbjorng5166
@mtbjorng5166 Ай бұрын
They need to update AC ports its embarassing for the brand
@thanhnguyen-xi8fq
@thanhnguyen-xi8fq Ай бұрын
Save money, go for the Easy Solar version.
@unakagearcompany
@unakagearcompany Ай бұрын
Cheaper doesn't equal better.
@thanhnguyen-xi8fq
@thanhnguyen-xi8fq Ай бұрын
@@unakagearcompany I means saving money, to buy an all in one Victron product (Easy Solar) and don't have to think what to buy to complete your system. It more expensive.
@STRUTZKOFF
@STRUTZKOFF 4 ай бұрын
3000va
@unakagearcompany
@unakagearcompany 4 ай бұрын
Good catch, we changed the name of the video to 3000va. Think we should explain why Victron uses 'va' versus 'watt' in a future video?
@davidmills2266
@davidmills2266 4 ай бұрын
not 3000w....rated for 2400w
@unakagearcompany
@unakagearcompany 4 ай бұрын
You are correct, the 3000 is actual volt amps, not normal operating watts can vary based on temperature!
@mtbjorng5166
@mtbjorng5166 Ай бұрын
Victron brand inverters has by far the worst AC ports in the RV industry. Been Working full Time for 5 years in the industry atm and I wouldn't recommend buying these products. Buy Kisae or even Renogy has better AC ports than Them its a shame.
What Is A Kilowatt?
2:44
Unaka Gear Co.
Рет қаралды 3,5 М.
Victron Made Easy! Design and Communication, Step-by-Step
16:48
DIY Solar Power with Will Prowse
Рет қаралды 877 М.
МАМА И STANDOFF 2 😳 !FAKE GUN! #shorts
00:34
INNA SERG
Рет қаралды 4,4 МЛН
WHO DO I LOVE MOST?
00:22
dednahype
Рет қаралды 80 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 12 МЛН
Every Victron Inverter/Charger COMPARED!
13:52
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 89 М.
The end for Victron? Is this the future for van life power?
14:29
UrbanArkOverland
Рет қаралды 22 М.
Comparing Cheap Inverter vs Victron Multiplus II RV inverter!
13:32
Victron energy  multiplus-2, DO NOT MAKE THIS MISTAKE.
21:20
Amsoil Adam
Рет қаралды 133 М.
Victron Phoenix 1200VA LF Inverter: Extremely Low Standby Consumption and More!
12:13
DIY Solar Power with Will Prowse
Рет қаралды 272 М.
Understanding the Victron Products
20:41
The Off-Grid Shop
Рет қаралды 46 М.
Number plate hider with remote #numberplate #hider #riderlife
0:15
Husqvarna Toy&Husqvarna LC 140 SP@vigosworld
0:14
Vigo's world
Рет қаралды 12 МЛН
Это мои машины😏
0:16
PetrBillion & Father
Рет қаралды 1,6 МЛН
ШТРАФ - БЛОКИРОВКА КОЛЕСА в США🚗
0:33
MEXANIK_CHANNEL
Рет қаралды 3,9 МЛН