Viking Wet Pipe Alarm Check Valve System - System Reset Procedure

  Рет қаралды 82,970

Viking Sprinkler

Viking Sprinkler

Күн бұрын

System reset procedure for the Viking Wet Pipe Alarm Check Valve System. More information available at vikinggroupinc....

Пікірлер: 7
@vikramrio
@vikramrio 10 жыл бұрын
Awesome. Simple and to the point. Thank you.
@jamesredmond7360
@jamesredmond7360 11 жыл бұрын
A main drain test "drain drop" should be performed anytime the control valve has been closed to ensure control valve is fully open and proper flow. Same reason we flow test hydrants to check for obstructions in the water supply. Residual supply pressure should usually not exceed 10 psi drop when 2" main drain is fully open.
@Vikingsprinkler
@Vikingsprinkler 12 жыл бұрын
In the United States an Excess Pressure Pump is not used in the trim, and the gauges will show the same pressure at the time of set-up. If the Water supply is a variable supply, once the pressure increases the top gauge will show the highest pressure that the system has been exposed to, while the lower gauge will show the current pressure.
@ahmednagi8583
@ahmednagi8583 5 жыл бұрын
i need 7 pice please contact number or supplier in saudi arabia
@aymanbiomy4756
@aymanbiomy4756 3 жыл бұрын
Is it mandatory in nfpa? Where is the best position to install is it in pump room or outside it? Is the only propose of it to get alarm sound?
@mechtrotip5034
@mechtrotip5034 4 жыл бұрын
But why is mechanical alarm required When we have detectors connected to alarms
@liminalreality9617
@liminalreality9617 Жыл бұрын
1:05 a WHAT CHAMBER
System Reset: Model F Dry Valve - Dry Pipe Fire Sprinkler System
15:05
Viking Sprinkler
Рет қаралды 28 М.
Know More Risk: Wet System -“ Alarm Check Valve
4:37
Fortunately, Ultraman protects me  #shorts #ultraman #ultramantiga #liveaction
00:10
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 81 МЛН
Incredible Dog Rescues Kittens from Bus - Inspiring Story #shorts
00:18
Fabiosa Best Lifehacks
Рет қаралды 23 МЛН
Viking Double Interlock Preaction System - System Reset Procedure
3:58
Viking Sprinkler
Рет қаралды 94 М.
ITM Wet System Riser, Backflow and Connections
4:08
Northern Illinois Fire Sprinkler Advisory Board
Рет қаралды 32 М.
777X Failure Just Got Worse - Boeing Is Losing Everything
8:14
System Reset: Model F Straight Through Deluge Valve - Double Interlock
7:04
Know More Risk: Wet System -“ Riser Check Valve
3:08
TYCO® DPV-1 Dry Pipe Valve Installation
5:15
Fire Protection Products from Johnson Controls
Рет қаралды 25 М.
Model EX Low Pressure Dry Pipe Valve Reset Procedure
7:19
Reliable Automatic Sprinkler Co., Inc.
Рет қаралды 34 М.
DC Test Procedure
10:09
Viking II Backflow Training
Рет қаралды 20 М.
Fortunately, Ultraman protects me  #shorts #ultraman #ultramantiga #liveaction
00:10