The video is talking the problem solution of fiber laser cutting machine, the water chiller for laser cutter. You will find the common alarm happened to the chiller and corresponding solutions.
Hanli Chiller: www.hanlizl.cn/
Our Store/Nuestra Tienda:www.spierlaser.en.alibaba.com
Contact: clara@spierlaser.com +86-13335151833
Hi, I am Clara, last week, I got an inquiry from Canada, he said that there is alarm error on the chiller. The chiller is from Hanli, and the cutting machine is 2000W. Today I will share his problem and solution, if you are facing such similar issue, probably the video will be a guidance for you. Before get into the main chapter, please don’t forget to subscribe to this channel and give me your like, it helps me out a lot, thank you.
Over here, we can see the statement, it is E10 error, which doesn’t show any water pressure. This is an E12 E10 alarm caused by poor water circulation between the chiller and the cutting head. If such an alarm occurs, we need to unplug the outlet and return hoses from the water chiller to dredge. Here we will show you an example of dredging.
The second alarm is the E05, we can see the customer’s statement, he said water flow switch.
For solving this problem, first we need to shut down the chiller and exhaust the air. We can find the position to exhaust air in the video.
But after the step, the problem is still there, we can see the alarm shown in the display screen of the chiller. What should we do now? We need to check the water pressure and clean up the filters. And where is the filters of Hanli chiller? I will show you pictures.
After all those steps, the problem was done, but probably there will be other alarms. Here, I will share some common alarms happened to Hanli chiller, but attention here, it is not the specific solution for all the same problems. Please refer to your supplier or professionals for more help.
E01 stands for low temperature probe failure. For this, we first need to check whether the low temperature connector on the control panel is well connected. We can try to re-plug it, and then restart the water chiller.
E02 stands for low temperature water high temperature alarm. First, we need to try to feel the temperature of the air outlet with our hands. If the temperature is not different from the outside, we need to check whether the power supply is abnormal at this time; if we feel hot air, we need to clean the heat sink next to it.
E04 stands for phase sequence alarm. At this time, we need to check whether the phase sequence warning light is always on; if the light is on, we need to check whether the voltage of the power supply is normal; if the voltage is normal, we need to check the external power supply and replace it accordingly.
E05 stands for low temperature water flow alarm. We need to check whether the water pump is running normally and if there is water flow in the low temperature water pipes.
E07 stands for compressor overload, we need to clear the dust filters on both sides.
E08 stands for low temperature alarm for low temperature water. This alarm will be generated when the low temperature water is lower than 2 degrees Celsius. At this time, we need to add antifreeze.
E11 stands for the low temperature alarm of normal temperature water. At this time, we need to pay attention to whether the normal temperature heating indicator is always on; check whether the yellow line of the normal temperature heating tube has current passing through.
That’s it, if you need me to offer service, no matter it is laser cutting, laser marking, or laser welding, please feel free to write to me. My contact information is over here, or you can also find my contact in the description below, both WhatsApp and mail are super fine. But I need to explain myself, not all services I am capable of are free, like personal checks, it is not free, hoping you can understanding. Thank you for joining me today, I will see you next Tuesday here on my KZfaq channel, see you!Bye!

Пікірлер: 27
@adityapatel1937
@adityapatel1937 2 ай бұрын
Please shoot vedio regarding E10 ALARM IN HANLI WATER CHILLER
@adityapatel1937
@adityapatel1937 3 ай бұрын
Please shoot vedio for E11 ALARM IN HANLI WATER CHILLER
@ClaraChai
@ClaraChai 3 ай бұрын
Planning
@MandaB365
@MandaB365 2 ай бұрын
@@ClaraChai Is this video available yet?
@renjithkrishnan3945
@renjithkrishnan3945 Жыл бұрын
I have E07 alarm in hanli chiller
@bernardohidrosul9710
@bernardohidrosul9710 Жыл бұрын
Hi Clara! Thank you for the video, it's helped me a lot. One question about HanLi Chiller: i have a HL-1000 model with my laser machine, and today we got E05 and E12 alarms. Watching your video and reading the Chiller's manual, I've tried all of the maintenances, but unsucessful. So, when we've checked the Pump, it was very very hot and the fan was stuck. It can be a problem with pump, or the pump is not working for some other reason?
@ClaraChai
@ClaraChai Жыл бұрын
Try to remove the covers of the pump, and listen whether this is a sound , like a bee. Probably the pump is frozen or some what.
@sanilkumarsanal8353
@sanilkumarsanal8353 Жыл бұрын
How to settings chiller p
@owenf777
@owenf777 Жыл бұрын
Nice videos good teaching.! What is the right goggles for laser welding?
@ClaraChai
@ClaraChai Жыл бұрын
It is up to the laser power, what I configured for our customer is OD6+ for 1000W. Visit my Alibaba store, there is protective goggles, www.spierlaser.en.Alibaba.com
@noyakzvlogs1772
@noyakzvlogs1772 Жыл бұрын
Why servo alarm is coming and stop functioning of go home
@omercan8360
@omercan8360 9 сағат бұрын
l have E02 and E010
@moyadezz2638
@moyadezz2638 2 жыл бұрын
i need help please how to make the machine cold the machine laser need 20c in summer dosent worka good how to make machine more colder how to cold it with water or nas
@ClaraChai
@ClaraChai 2 жыл бұрын
I am confused on what you need.
@moyadezz2638
@moyadezz2638 2 жыл бұрын
@@ClaraChai cah i contact u on mail or sth to show u my problem plz!
@ClaraChai
@ClaraChai 2 жыл бұрын
@@moyadezz2638 +8613335151833. clara@spierlaser.com
@YuliusGunawan-wo3pl
@YuliusGunawan-wo3pl Жыл бұрын
hi clara I have problem E12 and already did like your video but still got same alarm, and i already save your number but not show there is whatsapp
@ClaraChai
@ClaraChai Жыл бұрын
+86-13335151833
@Thespecialist.kayyali
@Thespecialist.kayyali Жыл бұрын
We have e12 alarm and i did the dredging but still have the same alarm
@ClaraChai
@ClaraChai Жыл бұрын
Please tell me more, 86-13335151833
@stanbriggs5617
@stanbriggs5617 11 ай бұрын
hi Cara I would like to send you some videos and i would like your opinion on what the problem might . If you could let me know if you want to have alook at them and where to send them .I could use a hand with it
@ClaraChai
@ClaraChai 10 ай бұрын
+86-13335151833
@stanbriggs5617
@stanbriggs5617 6 ай бұрын
i live in Canada and my Hanli chiller will no turn on it dose not matter what buttons i push can you help
@noyakzvlogs1772
@noyakzvlogs1772 Жыл бұрын
What is the cause of Servo alarm?
@ClaraChai
@ClaraChai Жыл бұрын
You need to check the code of alarm.
@timuralibegov7721
@timuralibegov7721 7 ай бұрын
I have e06 alarm
@ClaraChai
@ClaraChai 4 ай бұрын
There is blocking in water hose.
Is the GWeike G2 Fiber Laser Worth the Hype?
13:34
Clough42
Рет қаралды 76 М.
Double Stacked Pizza @Lionfield @ChefRush
00:33
albert_cancook
Рет қаралды 63 МЛН
ОСКАР vs БАДАБУМЧИК БОЙ!  УВЕЗЛИ на СКОРОЙ!
13:45
Бадабумчик
Рет қаралды 6 МЛН
How to Change the Water in Your Chiller for an Aeon Mira 9
2:33
Party With A Laser
Рет қаралды 598
Top 3 Questions about building a DIY Fiber Laser Cutter
13:23
Travis Mitchell
Рет қаралды 23 М.
OMTech 5200 / 5202 - Constant Temp Mode Settings
3:40
Bearded Builds Co
Рет қаралды 21 М.
Are cheap laser cutters safe?
18:11
Maker's Muse
Рет қаралды 337 М.
how to adjust temperature for your Hanlichiller
1:05
Hanlichiller
Рет қаралды 3,4 М.
Samsung laughing on iPhone #techbyakram
0:12
Tech by Akram
Рет қаралды 656 М.
АЙФОН 20 С ФУНКЦИЕЙ ВИДЕНИЯ ОГНЯ
0:59
КиноХост
Рет қаралды 1,1 МЛН
EXEED VX 2024: Не өзгерді?
9:06
Oljas Oqas
Рет қаралды 46 М.
Top 50 Amazon Prime Day 2024 Deals 🤑 (Updated Hourly!!)
12:37
The Deal Guy
Рет қаралды 1,4 МЛН