Water Pouring Out Of Boiler Case & 10K Giveaway Incoming! - A Day In The Life Of A Gas Engineer 111

  Рет қаралды 7,987

CP Utility Solutions

CP Utility Solutions

6 ай бұрын

Typical last job of the day bad luck. Try to open the case and water pours out everywhere! Had a good run of jobs before this one. Love silly season, keeping busy, bouncing from job to job.
#plumbing #heating #boiler
www.unilite.co.uk
Use code UNCLE for an extra 10% off their January sale, then 25% off their retail prices
Powered Now - Job Management Software
www.powerednow.com/cputility-2
towel radiator
vaillant
ufh
underfloor heating
blockage
magnetite
scale
lockshield
radiator valves
electric
boiler
electrical
wiring

Пікірлер: 54
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Thank you for watching! If you enjoyed today's video please don't forget to LIKE & SUBSCRIBE 🙏🏾
@bane8722
@bane8722 6 ай бұрын
Keep up the hard work, we appreciate the time and effort you take to make these videos 👍🏻❤️
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Thank you 🙏🏾
@user-li8gr8ur8l
@user-li8gr8ur8l 6 ай бұрын
Another top quality jobbing video. Thanks Chirag.
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Glad you enjoyed 👍🏾
@user-kq9gq2xq2f
@user-kq9gq2xq2f 6 ай бұрын
That filing loop on the first job would keep me awake at night!
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
😂
@ak0792
@ak0792 6 ай бұрын
Agreed....did you change the actual dial?
@michaelward8180
@michaelward8180 6 ай бұрын
@@ak0792He's referring to the filling loop fitted on the first job where he converted to a pressurised system and presumably its aesthetically pleasing design 🤣
@bluebulldog_uk
@bluebulldog_uk 6 ай бұрын
Used to carry 2 of those diverters back in my BG days as van stock always kept us busy 😅👍
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Defo mate you know it 😂👊🏾
@steveincork3669
@steveincork3669 6 ай бұрын
Prv fitted as part of gas regs in Ireland as a precaution in case of frozen open vent pipes. Very common too on external oil boiler installs operating under gravity open vent design.
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Nice one mate 👍🏾
@daljitsingh549
@daljitsingh549 6 ай бұрын
Another great video, informative and very helpful as usual.
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Nice one 👍🏾
@johnprice4
@johnprice4 6 ай бұрын
Looks to me like the CFOV are plumbed upstairs not near the boiler, PRV probably retrofitted on the boiler as iso valves on pump and magnaclean mean heat source could be isolated from OV. One way to do it 😂
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Good point mate 👍🏾
@effervescence5664
@effervescence5664 6 ай бұрын
It used to be considered good practice to put a prv/temperature relief on open vented if the open vent was across the other side the house and 3 floors up. Was pretty uncommon and only due to the expansion not being able to overcome the resistance of the pipework length.
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Nice one thanks for the info 👍🏾
@mohammedayaz4342
@mohammedayaz4342 6 ай бұрын
Hello brother Allah (God) bless u, I have been watching your work for long time keep the good work up, I love your honesty and skill which we all appreciate
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Thank you 🙏🏾
@willemgijs3803
@willemgijs3803 5 ай бұрын
New sub bro. combi boiler service mechanic in the netherlands here.
@cputilitysolutions
@cputilitysolutions 5 ай бұрын
Thanks and welcome to the channel 👊🏾
@tonymurff5234
@tonymurff5234 6 ай бұрын
Nice busy day that was 😂, Brilliant content as always mate, 👍👍🤜🤠
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Thanks Tony 👊🏾👊🏾
@rscelectrical7091
@rscelectrical7091 6 ай бұрын
Great video buddy and top diagnostic practice as always.
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Thank you 🙏🏾
@rscelectrical7091
@rscelectrical7091 6 ай бұрын
​@@cputilitysolutions: Your welcome, it's always good to watch you fault finding. I can't remember the last time I got involved in the Electrics for a heating system.
@happybunny7490
@happybunny7490 6 ай бұрын
The prv are being used as a drain off I’ve seen it a few times, hey at least it drains to outside but watch out for a dirty wall sometimes
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Yup 👍🏾
@jameswilson2899
@jameswilson2899 6 ай бұрын
Great content mate.
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Thank you mate 👍🏾
@madshepsreef282
@madshepsreef282 6 ай бұрын
Thankyou
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Welcome 👍🏾
@alanmann8066
@alanmann8066 6 ай бұрын
Those vaillant diverter valves can be a right arse to get that locking nut off
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Yup, I prefer the ones where it's inside below the pump
@arcturus475
@arcturus475 6 ай бұрын
Quality content
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Thank you 👍🏾
@kapilsammy
@kapilsammy 6 ай бұрын
Just use your code uncle bought my self slr1450 plus spare battery long waited thanks bro
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Nice one 👍🏾
@sjallsopp7778
@sjallsopp7778 6 ай бұрын
Another interesting video, can you put up a link for the gas solutions book RS Gas as I can’t find it? Thanks
@user-te1le7ck6b
@user-te1le7ck6b 6 ай бұрын
Be good for you to give prices of some common jobs
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
👍🏾
@b1h2u3p4
@b1h2u3p4 6 ай бұрын
Can you just replace the divertor cartridge on vaillant also working out expansion vessel size on first job 18 rads 24 litre what formula you guys used to work this out.
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
You can, but I've not done the cartridge replacement before. I've heard mixed things about it. Regarding the vessel, general rule of thumb is 10% of the volume of water in the system. Without going into in depth calculations with different size rads I take approx 10L per rad (180L) and then go a size bigger on the vessel as you can't go wrong with a bigger vessel but you can have problems if it's undersized
@b1h2u3p4
@b1h2u3p4 6 ай бұрын
@@cputilitysolutions Thanks
@mikeolin2561
@mikeolin2561 6 ай бұрын
wud ad put the nrv on to stop her pitching cause of the position of pump
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
Sorry could you explain what you mean please?
@Zaine22
@Zaine22 6 ай бұрын
Did use patch that flue up, also was that not a dhw vessel
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
That was a heating vessel 👍🏾
@illuminate06
@illuminate06 6 ай бұрын
Which unilite is that and which one do you recommend?
@cputilitysolutions
@cputilitysolutions 6 ай бұрын
My favourite is the IL-925R and the SLR-1000 or the newer SLR-1450 👌🏾
@S.Trades
@S.Trades 6 ай бұрын
Do you not get harassed by the police, as a successful, hardworking, talented, young man? I had them seize and confiscate my completely legal work van. Allegedly.
These Were Still Live! - A Day In The Life Of A Gas Engineer 166
22:03
CP Utility Solutions
Рет қаралды 307
My Luck Is Never This Good - A Day In The Life Of A Gas Engineer 121
19:03
CP Utility Solutions
Рет қаралды 6 М.
Heartwarming Unity at School Event #shorts
00:19
Fabiosa Stories
Рет қаралды 25 МЛН
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 28 МЛН
Пранк пошел не по плану…🥲
00:59
Саша Квашеная
Рет қаралды 6 МЛН
Just when you think it's going to be a good day.....
34:56
Plumb Like Tom
Рет қаралды 10 М.
How to Correctly Fill & Vent Your Central Heating System
6:30
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2,1 МЛН
This Job Went From Bad To Worse!! - A Day In The Life Of A Gas Engineer #22
39:22
Customer Bodged This Himself! - A Day In The Life Of A Gas Engineer 109
24:17
Plumbers from hell left this behind
14:56
Urban Plumbers
Рет қаралды 76 М.
I Had To Walk Away From This One - A Day In The Life Of A Gas Engineer 104
24:20
Is This Heat Pump Better Than Your Gas Boiler?
11:19
Urban Plumbers
Рет қаралды 327 М.
The Previous Installer Got It Wrong - A Day In The Life Of A Gas Engineer 157
16:04