What Will Happen if Transformer Neutral Supply Brake

  Рет қаралды 15,230

The Electrical Guy

The Electrical Guy

Жыл бұрын

What Will Happen if Transformer Neutral Supply Brake
In this video, we will discuss what will happen if the neutral supply of the transformer fail near to our home
Watch the complete video to learn more in details
Thank You
Arun Gupta
Electricaltechnician02@gmail.com
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Hindi Channel @Electrical Technician
/ electricaltechnician
2nd Channel @electrical Wiring School
/ electricalwiringschool
Short Video @electrical technician Shorts
/ @electricaltechnician02
TELEGRAM :
telegram.dog/ElectricalTechnic...
FACEBOOK : @electricaltechnical
/ electricaltechnical
INSTAGRAM : @electricaltechnician02
/ electricaltechnician02
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
My gadgets for KZfaq 📺
Camera 📸 For video Recording
amzn.to/3z3W9XM
Mic 🎤 For Sound Recording
amzn.to/3kpUyaK
Tripod Stand
amzn.to/3BajZmn
Overhead Stand For Recording
amzn.to/3z1rzhm
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
You Should watch this videos too
Amp to Watt Calculation in Electrical system
• Amp to Watt Calculatio...
Capacitor Value to Save Electricity Bill
• Capacitor Value to Sav...
Cooling Methods Used for Transformer
• 7 Most Effective Type ...
#transformer #electrical #interview #electrician

Пікірлер: 25
@simonmaina2557
@simonmaina2557 Жыл бұрын
You are so knowledgeable my friend God bless you
@AnasAl-Dhafiri
@AnasAl-Dhafiri Жыл бұрын
Many thanks for your useful videos
@mohamedriyaz4545
@mohamedriyaz4545 Жыл бұрын
Well explained
@kaundabwalya7776
@kaundabwalya7776 Жыл бұрын
Keep them wonderful Videos coming Sir 👍.. & May GOD Bless you 🙏
@patrickmbalame5534
@patrickmbalame5534 Жыл бұрын
Keep up good work sir
@sheeteeshdansena7521
@sheeteeshdansena7521 Жыл бұрын
Very nice
@harshthacker8627
@harshthacker8627 Жыл бұрын
You get new Electrical sub bro... Great explanation...
@noelfaithfulkari2857
@noelfaithfulkari2857 Жыл бұрын
Thank you sir. Could you do a video on transformer sizing for 200homes
@bamideledauda2447
@bamideledauda2447 11 ай бұрын
Pls can you do full detail tutorial on conduit pipe laying for building and distribution of wires to circuit breaker. Thks
@zaacdozaacdo7004
@zaacdozaacdo7004 Жыл бұрын
Very nice bro
@SiyaiDuanyoDavid
@SiyaiDuanyoDavid Ай бұрын
🎉
@purushoth9053
@purushoth9053 Жыл бұрын
Very clear explain for beginner in electrician, my role maintenance electrician so basic troubleshoot methods can you explain please sir.
@johnkiran3306
@johnkiran3306 Ай бұрын
And please explain how the impedance will be different across houses. I mean if yellow house has all devices off at the moment. What will be the impact
@johnkiran3306
@johnkiran3306 Ай бұрын
Please tell the protective measures as well
@DH-tv2yw
@DH-tv2yw 3 ай бұрын
Would the house with low voltage also suffer damage? E.g. motors that labour and overheat?
@2010bolte
@2010bolte 11 ай бұрын
Thank you, but I thought that phase to phase would be 400V at a phase angle of 120 degrees. In stead of 415V.
@temp06j723-pmeighttq
@temp06j723-pmeighttq Ай бұрын
240/415V 230/400V
@pankajsonu3768
@pankajsonu3768 Жыл бұрын
Sir, How can we find resistance of a House
@echenduconfidence4998
@echenduconfidence4998 10 ай бұрын
What if you link ur earth to neutral bar. From TT to t n c s.what will happen
@temp06j723-pmeighttq
@temp06j723-pmeighttq Ай бұрын
It it NOT for you to simply "link" your own TT Earthing to N-bar to make it so called TNCS🚫 TNCS is defined by the Integrity of the PEN Supplied by the Electricity Supplier deemed fit to be used as "Protective Earthing" within Premises.
@temp06j723-pmeighttq
@temp06j723-pmeighttq Ай бұрын
If you are Adding a Supplementary Earthing (by adding Local earthing rods to Strengthen the PME network) to your TNCS supply, that is another different story.
@30mAkills
@30mAkills Ай бұрын
Assume your earth electrode is corroded or no continuity. You don't know this as the linked neutral was acting as earth. One fine day your service neutral floats. Now no neutral no earth. In this scenario all your appliances will not work. But the metal bodies will get energized due to looping. (phase to neutral to earth to metal bodies). You touch your fridge and die! Hope this helps.
@montatharhayder
@montatharhayder 5 ай бұрын
If i have a device in my house works on 3 phases and the neutral break down from the transformer, does this device will damaged too?
@temp06j723-pmeighttq
@temp06j723-pmeighttq Ай бұрын
Depends if the Device/Equipment is tailored for 3Ø supply ? Eg 3Ø ∆ Motor will work fine but if any Control circuitry that runs on Single Phase Eg PSU/contactor will probably get damaged. To consider also if that Equipment all-together is protected by any means of Overvoltage Protection devices.
@30mAkills
@30mAkills Ай бұрын
Broken neutral cannot damage 3 phase devices.
Does Current Flow on the Neutral?
23:03
Electrician U
Рет қаралды 1 МЛН
Её Старший Брат Настоящий Джентельмен ❤️
00:18
Глеб Рандалайнен
Рет қаралды 8 МЛН
Китайка и Пчелка 4 серия😂😆
00:19
KITAYKA
Рет қаралды 3,7 МЛН
Losing or "Dropping" a Neutral on a 120/240V System
10:28
Taking Measure
Рет қаралды 51 М.
Why Varistor Is Used? MOV, Varistor and VDR Explained @TheElectricalGuy
8:19
Why there is no Neutral in Transmission Lines?  Explained | TheElectricalGuy
8:46
Gaurav J - TheElectricalGuy
Рет қаралды 138 М.
What is Ground
19:08
Vocademy - Electronics Technology
Рет қаралды 6 М.
Can we remove Neutral wire? Importance of Neutral wire
7:54
Gaurav J - TheElectricalGuy
Рет қаралды 77 М.
Does Current Flow Through The Neutral Wire?
7:41
eFIXX
Рет қаралды 322 М.
What is the Difference Between Grounding, Bonding and Neutral?
15:15
Open Neutral
11:41
Dave Gordon
Рет қаралды 817 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 4,9 МЛН