Where do the Acceptance Criteria in Method Validation Come From? - Webinar Recording

  Рет қаралды 10,193

Mourne Training Services Ltd

Mourne Training Services Ltd

Күн бұрын

Пікірлер: 15
@tanvirahmedsohag4086
@tanvirahmedsohag4086 2 жыл бұрын
Thanks for the HPLC calculator I use it a lot
@MTStraining
@MTStraining 2 жыл бұрын
Delighted that you are finding the calculator useful! Thank you for the feedback.
@user-ps9nv2vl7c
@user-ps9nv2vl7c 13 күн бұрын
do you have an references for what you have discussed that I could look up?
@MTStraining
@MTStraining 11 күн бұрын
General textbooks on analytical chemisty may be helpful for a discussion of errror sources, e.g., 'Fundamentals of Analytical Chemistry', by Skoog et al.
@phelanapostol1275
@phelanapostol1275 2 жыл бұрын
Hello, regarding the criteria for the accuracy and precision, what if I am analyzing an analyte with a true concentration of 5000ppm and I quantify it using external calibration with an analytical range of 1ppm to 10ppm, wherein the sample mass was 0.5grams and the total dilution factor of 500 to fit the sample in the calibration curve, what will be my acceptance criteria for accuracy? is it on the level of the analytical range (1-10ppm) or on the level of 5000ppm?
@MTStraining
@MTStraining 2 жыл бұрын
The error that arises as a result of the sample preparation (which includes the dilution step) will relate to the proportion of the component present in the sample, therefore I would advise that you base your acceptance criteria on the actual test material concentration, i.e. 5000ppm
@thehealer8330
@thehealer8330 2 жыл бұрын
this webinar did not provide any information regarding acceptance limit or criteria for validation parameter?? from usp or fda or ich. guideline for acceptance criteria for each parameter of method validation especially accuracy
@MTStraining
@MTStraining 2 жыл бұрын
Hi Muhammad, The simple reason for that is that there are no acceptance criteria provided in the guidelines from ICH and FDA. The purpose of this video is to help you understand the values that people typically use.
@inticorrientes3129
@inticorrientes3129 2 жыл бұрын
what about Horwitz Ratio as a precision acceptance criteria? what should I look in order to know if it is a good criteria for a particular method?
@MTStraining
@MTStraining 2 жыл бұрын
The examples of acceptance criteria for precision that were presented towards the end of the webinar were actually calculated using the Horwitz equation (RSDR = 2^(1 - 0.5logC)) and I do think that it is a good tool for estimating the expected precision for a given sample. It tends to be slightly pessimistic at high concentrations, and more noticeably so at low trace concentrations.
@satnamom4667
@satnamom4667 2 жыл бұрын
Hello mam, I like your webinar very much. I have one query... During precision studies, we carry out 6 replicate analysis. The %rsd of these should be calculated of rounded values or unrounded values?
@MTStraining
@MTStraining 2 жыл бұрын
I would advise that the data is expressed in the same way as when you are following the method for a routine analysis. This would typically involve using data with one more decimal place than the final result. For example, if the method is performed in duplicate it is typical to calculate the mean (reportable value) using the unrounded results for each of the duplicate determinations, and then round.
@satnamom4667
@satnamom4667 2 жыл бұрын
@@MTStraining thank you for your response ma'am. But my concern is during routine analysis, the final rounded figure is declared. So while precision studies during validation, the rsd shoud be calculated of 6 rounded off values.... Do you agree? Can you please share me your email id so that I can share a live case....
@dmahmood1991
@dmahmood1991 2 жыл бұрын
@@satnamom4667 Nooooo, dont round!!! All calculations should be done using 5 s.f. (as a guide) once you have calculated then you can round. A lot of calculations are based on the fact that data is normally distributed... however, if all your data is 2.2, 2.2, 2.2, 2.2, 2.2, 2.2 you would have no standard deviation which is obviously not correct. Therefore you are losing valuable information by rounding.
@shoaibfaraizi
@shoaibfaraizi 2 жыл бұрын
Ad hominem.
Strategies for HPLC Method Development - Webinar Recording
50:51
Mourne Training Services Ltd
Рет қаралды 23 М.
Life of a Test Method: Validation, Verification, and Managing Quality
58:46
Centers for Disease Control and Prevention (CDC)
Рет қаралды 2,2 М.
小丑把天使丢游泳池里#short #angel #clown
00:15
Super Beauty team
Рет қаралды 43 МЛН
UNO!
00:18
БРУНО
Рет қаралды 5 МЛН
SPILLED CHOCKY MILK PRANK ON BROTHER 😂 #shorts
00:12
Savage Vlogs
Рет қаралды 47 МЛН
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 197 МЛН
Practical Tips to Manage Laboratory QC Data
57:49
Labroots
Рет қаралды 6 М.
Analytical Method Development and Validation for Compliant Testing  Webinar
1:01:09
Accuracy of an analytical method
32:05
Pharma Growth Hub
Рет қаралды 7 М.
How to define limit for unknown, known and total impurities
26:07
Pharma Growth Hub
Рет қаралды 54 М.
Method Validation Webinar
31:22
Americans for Safe Access
Рет қаралды 15 М.
ICH Stability Testing and Method Development
44:51
Nelson Labs
Рет қаралды 27 М.
A Brief Guide to HPLC Instruments from Mourne Training Services
8:12
Mourne Training Services Ltd
Рет қаралды 387 М.
What is Method Validation? How to perform Method Validation?
31:27
Pharma Growth Hub
Рет қаралды 42 М.
小丑把天使丢游泳池里#short #angel #clown
00:15
Super Beauty team
Рет қаралды 43 МЛН