Student training aid for the connections required to wire a lighting circuit using the 3 plate loop-in method. Video explains the connection required within the ceiling rose, a consumer unit (fuse box) and in 2 way switches. The circuit is wired in twin and cpc cables (twin and earth cable) and is a wiring diagram for this circuit. This video will show learners how to connect up a ceiling rose and pendant and 2 way light switches.
How to wire up a light and a two way switched lighting circuit. This wiring diagram will help you understand the connection requires in a 2 way lighting circuit.
☑️ Link below is to the images used in this series of videos on lighting wiring diagrams
1drv.ms/b/s!As2jEnZePpD0iXUBd...
🔵 Wiring Diagrams for Lighting and Motor Circuits • Wiring Diagrams for Li...
== 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 - Wiring diagram 2 way switching
00:46 - 2 way switching demonstration
01:05 - Looking back at 1 way switching of a light wiring diagram
01:18 - Connections in a 1 gang 2 way switch : common, L1 and L2
01:52 - Connection in a ceiling rose or batten lamp holder
02:26 - Cables for 2 way switching of a light twin and CPC (twin and earth) and 3 core and CPC
03:47 - Cable from the consumer unit to the lighting point
06:28 - Cable from the light to the first 2 way switch
08:25 - Cable from the first 2 way switch to the second 2 way switch
11:25 - Circuit connections is the light on or off
12:50 - Extending the lighting circuit into another room
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram and Twitter lookout for "GSH Electrical.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
#GSHElectrical #Electricaltrainingvideos #wiringdiagram

Пікірлер: 154
@robertallen2151
@robertallen2151 2 жыл бұрын
I’ve learned more in 15 minute from this video than I have the entire month since I started my course. Massive Props for explaining things properly considering my tutor is only arsed about telling bad jokes😂
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Robert massive thanks for watching and the support 👍🏻. Gaz
@jmohammad3762
@jmohammad3762 3 жыл бұрын
Simply the best tutorial from big Gaz. Saved this video to my saved list. Thanks GSH electrical.👍👍👍. Pleasure watching you guys and learning.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks 🦾
@faheeminengland
@faheeminengland 3 жыл бұрын
Hi, Gaz, Sincerely I cannot thank you enough and how as a beginner, I got rid off my misconceptions about slewing on different colour cables of two way switching by watching this video. Keep up the good work😊👏🏻👍🏻
@terencekelly477
@terencekelly477 Жыл бұрын
Thanks very much Gary you are good instructor and put alot of effort into your videos they are enjoyable and a very good learning experience.
@jdrelectricaltelford8896
@jdrelectricaltelford8896 3 жыл бұрын
Really wish your videos were around whilst I was doing my apprenticeship back in 2002....great teacher 👍🏼 even though I know this it was still interesting to watch
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks Jay for the great comment 🦾. Gaz
@javed3006
@javed3006 3 жыл бұрын
Very good video and the way you explained with colour marker and step by step is brilliant 👍top star
@darrensmith7129
@darrensmith7129 2 ай бұрын
Great video, your videos have helped me understand the practical and theory behind it really well. Thanks 👍🏻
@GSHElectrical
@GSHElectrical 2 ай бұрын
Thanks for the great comment and watching 👍🏻
@Electronzap
@Electronzap 3 жыл бұрын
Good explanation :) Very cool circuit even though it is simple.
@MK2CLIOOWNERSUK
@MK2CLIOOWNERSUK Жыл бұрын
I cant wait to know half as much as you know...!!!
@andrewlewton1331
@andrewlewton1331 8 ай бұрын
Brilliant video, very clear and helpful instructions
@GSHElectrical
@GSHElectrical 8 ай бұрын
Thanks 👍🏻
@richardbattersby4274
@richardbattersby4274 6 ай бұрын
Thank you saved me a lot of hassle.
@GSHElectrical
@GSHElectrical 6 ай бұрын
Thanks for commenting and watching 👍🏻
@bradmace6144
@bradmace6144 2 жыл бұрын
Thank you. I have been able to master this at my own pace :)
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for commenting and watching 👍🏻
@HexhamFoodCo
@HexhamFoodCo Жыл бұрын
Fantastic, clear and informed
@GSHElectrical
@GSHElectrical Жыл бұрын
Massive thanks 👍🏻
@jasonturvey360
@jasonturvey360 2 жыл бұрын
Really enjoy watching them, very informative and breaks down a lot of book work in simple video's. Always use them when studying the relevant sections.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for the great feedback Jason 👍🏻
@poubarlenvydelingum6302
@poubarlenvydelingum6302 Жыл бұрын
Holle see?!!!!!!!
@poubarlenvydelingum6302
@poubarlenvydelingum6302 Жыл бұрын
See ?!!!!
@harrisonhoulden6752
@harrisonhoulden6752 6 ай бұрын
Thanks mate u just got me through a test at college 😂😂
@hugebartlett1884
@hugebartlett1884 3 жыл бұрын
Cleared up some mysteries for me!
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Glad it helped 👍
@josephqueen1878
@josephqueen1878 5 ай бұрын
Gary, An interesting method of wiring those switches. Here in the states we do it a bit differently. The strappers or travelers as we call them go to what you refer to as L1 & L2 the permanent line would go to the common of one switch and the switched line would connect to the common of the remaining switch to the light fixture. Both work equally well, but like a lot of things between the states and the UK they are done differently. Keep up the great work, I enjoy learning new things . Merry Christmas.
@GSHElectrical
@GSHElectrical 5 ай бұрын
Thanks for the detailed comment and watching Merry Christmas Gaz 🦾💕🦾
@kevinwright195
@kevinwright195 2 ай бұрын
Used your way quite often in the uk depended on job used a lot on conduit jobs.
@kevinfoley1198
@kevinfoley1198 3 жыл бұрын
Really well explained
@rayc1503
@rayc1503 3 жыл бұрын
Always a pleasure watching. I like the fact that you explain easy and simple enough for us to digest. Thanks 😊
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Massive thanks for the wonderful comment. Gaz 🦾
@landsendsolo
@landsendsolo 3 жыл бұрын
Excellent video and well explained.
@r7915
@r7915 3 жыл бұрын
Excellent presentation 👍🏻 look forward to the next one.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Wiring Diagram 2 Way & Intermediate Switching of a Lighting Circuit 3 Plate Method Connections kzfaq.info/get/bejne/gdBzobujsrLanac.html
@OfficeBoyBuilder
@OfficeBoyBuilder 3 жыл бұрын
This is a great video, thanks for taking the time to make it clear and easy to follow. Quick question; is it much different when you're wiring in LED's which don't seem to have a traditional looking ceiling rose? Or would you just wire them with Wagos instead?
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Taking the Feed (Supply) to the Light Switch the 2 Plate Method kzfaq.info/sun/PL2Ea5r9gxUUevU9gv8lizD53aYvwiJ5qr This playlist should help. Thanks for the great comment 🦾. Gaz
@OfficeBoyBuilder
@OfficeBoyBuilder 3 жыл бұрын
@@GSHElectrical awesome, thanks Gaz. I'd already seen one of those videos, but hadn't realised it was part of a series somehow! Thanks for the work you put in here mate.
@michealplater9007
@michealplater9007 3 жыл бұрын
Hi Gaz, as a electrician in Austraila, it is interesting to see how things are done in other countries. I take active,neutral and earth (cpc), to each light switch, then active to the common terminal at one switch, then join terminal one and two at each light switch using straps, then the second switch common terminal to the light. Two reasons for this way, most connections are done at the switch, on the floor and only one cable at the light fitting. In austraila the cpc has been insulated for about 25 years.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Taking the Feed (Supply) to the Light Switch the 2 Plate Method kzfaq.info/sun/PL2Ea5r9gxUUevU9gv8lizD53aYvwiJ5qr Like this?
@michealplater9007
@michealplater9007 3 жыл бұрын
Yes
@formbyjim
@formbyjim 4 ай бұрын
Very clear, thanks.
@GSHElectrical
@GSHElectrical 4 ай бұрын
Thanks for watching 👍🏻
@ashleystirland
@ashleystirland 8 ай бұрын
thanks great video
@Rashidali-xx5tt
@Rashidali-xx5tt Жыл бұрын
Explained very well thanks
@GSHElectrical
@GSHElectrical Жыл бұрын
Thanks 👍🏻
@aamrs7863
@aamrs7863 3 жыл бұрын
Finally I get it, thx to your explanation
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks
@bencruddos5503
@bencruddos5503 3 жыл бұрын
Thanks a lot. This really helped me :)
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks 👍
@enriquetuza375
@enriquetuza375 3 жыл бұрын
Gracias 🙏
@jashanveersingh6351
@jashanveersingh6351 5 ай бұрын
Good job
@GSHElectrical
@GSHElectrical 5 ай бұрын
Thanks
@cag9284
@cag9284 11 ай бұрын
Have you a video of the same, but when the feed is to the switch? Great video
@DjGiluk
@DjGiluk 2 жыл бұрын
Very informative thank you
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for watching 👍🏻
@rahatzafar
@rahatzafar 3 жыл бұрын
thanks you sir
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Your welcome 👍
@markaust2736
@markaust2736 3 жыл бұрын
Should you add a fused spur to a bathroom lighting circuit and fan before the isolator
@garymurphy1157
@garymurphy1157 2 жыл бұрын
Really good video.. Great teaching 👍
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Massive thanks for the support 👍🏻
@user-kj9qh4mh6c
@user-kj9qh4mh6c 3 жыл бұрын
Thanks a lot
@johncoppock3823
@johncoppock3823 3 жыл бұрын
Great video. Students prob find that style of drawing simplest to understand, but you could draw some sections of wires on the 45deg to avoid drawing wires through the middle of the switch plates. Do you ever cover doing a 2 way switch system using just T&E (but 2 cables) if no 3core plus earth avail? (Is that allowed in the regs)
@user-yw6qb9tt7t
@user-yw6qb9tt7t 2 жыл бұрын
They used to use 2 core and earth 40 years ago but you still need to run a third conductor as a single so effectively you have 3 core and earth but a single running alongside as the common.
@syedbukhari9703
@syedbukhari9703 3 жыл бұрын
Thank you
@sankyeat
@sankyeat 11 ай бұрын
Brilliant. I wish you were my teacher lol
@GSHElectrical
@GSHElectrical 11 ай бұрын
Thanks for watching 👍🏻
@arvindvanga
@arvindvanga 3 ай бұрын
Thanks for sharing your knowledge sir. Based on your video I propose to replace one of the two way switch with a smart switch. But I am confused as my comm is brown , L1 is Black and L2 is Grey. As you know for smart switch no neutral is required. Please can you help.
@DeanW-1990
@DeanW-1990 8 ай бұрын
Thank you for this but I have a question I have 4 separate lights that all go to a 4 way switch then a 2 cor cable going from the 4 way switch to the consumer unit I want to add another 4 way switch is this just a case of running a 3 cor from switch to switch ? Does this all sound ok ?
@cryptowardogs
@cryptowardogs 7 ай бұрын
Am I right in assuming I can’t take a feed for say a new wall light in the next room from the permanent live at switch 1? Is this because there is no permanent neutral at switch 1? I always have to come from the ceiling rose to install lights in other rooms?
@lawrencer25
@lawrencer25 Жыл бұрын
Fabulous video 👍👍👍
@GSHElectrical
@GSHElectrical Жыл бұрын
Thanks again. Gaz 👍🏻
@davidwood639
@davidwood639 3 жыл бұрын
Great instruction video. I am looking to change a pair of 2 gang 2 way light switches. Have you any wiring diagrams for this please?
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Take a picture on your phone and replace like for like 👍
@sekyanzinathan7521
@sekyanzinathan7521 2 жыл бұрын
Thanks so much. But I would like to help me, how can I control a number of light using the same switch and when each has its own switch to control it.(wiring diagram)
@miladmeah1792
@miladmeah1792 2 жыл бұрын
Hi Gary hope you're all well. Just wanted to give a big thank you, your videos have helped me with my course A LOT. One thing I am confused about and would like to ask you is; If I wanted to add an extra bulb to the existing circuit so both the lights turn on at the same time via the Two 1 Gang 2-Way switches, how would I do this. I have my practical exam coming up and would appreciate if you could help me out? Many thanks
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for commenting this maybe helpful Wiring Diagram Adding a Light But WHY Use 3 Core and CPC Cable Connections Explained kzfaq.info/get/bejne/nMdjlptpqd6mZas.html
@callumsimpson7483
@callumsimpson7483 2 жыл бұрын
If you want another light to be added you would have to put another T&E in the SW part of ceiling rose and connect to the nuetral and cpc.
@jaypowell9786
@jaypowell9786 3 жыл бұрын
Any chance you could do a video on 2 way lighting when the switches are fed please please? 👍🏼
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Wiring Diagram Lighting Circuit 2 Plate Method Taking the Feed to the Switch - 1 Way Switches& Light kzfaq.info/get/bejne/d5dphqaSm6y5o6c.html It will be next 🦾
@paolomarini6755
@paolomarini6755 3 жыл бұрын
Great video, thank you! Question: What kind of wiring method would it be one where both 2-way switches have L1=Blue (no sleeve), L2=Red, Common=Yellow BUT there is always only a SINGLE wire going into each switch connector? On the ceiling rose only a black and red appear on the opposite blocks (clearly neutral and switched line). Can’t figure out how this was wired (but it works).
@user-yw6qb9tt7t
@user-yw6qb9tt7t 2 жыл бұрын
That is classic 40 years ago 2 way wiring . 3 core and earth did not seem to be around then. Those colours which you identify at one switch run to another switch which also operates the same light. Rhis is known as the strapper. The colours at the ceiling rose will come from one of those two switches as it will be the switch cable.
@ianstanley5157
@ianstanley5157 2 жыл бұрын
I was watching Tom's video and wondering why you guys confuse 2 way switching ... it is such a simple task confused by the way you guys do it.
@matjones1557
@matjones1557 2 жыл бұрын
Amazing videos, how would this change using down lights? Without the loop?
@GSHElectrical
@GSHElectrical 2 жыл бұрын
You would need to put the connections into a joint box and wire from the to the downlights 👍🏻. Thanks for the support Gaz
@RC-oi1gg
@RC-oi1gg 8 ай бұрын
How do you identify the live cable coming in from the CU, line in, into the ceiling rose? Example if someone has used another Com terminal within the trio.
@sullyyehblud2045
@sullyyehblud2045 2 жыл бұрын
Really wish the wires could bend like that when I’m doing this😂
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Me 2 🤦🏻‍♂️👍🏻
@marktran5076
@marktran5076 2 жыл бұрын
Hi. Could you able to help me? I connected a 8 led batten lights in to a 4 gang switches (2 light per switch). The lights are sometimes dim and sometimes bright. Do you know what is a probable cause? I searched on the internet and it’s says loose wiring connections but I’m not sure. Thank you in advance.
@maxformosa3601
@maxformosa3601 3 жыл бұрын
How comes for the 1way switch the permanent line goes into common but for 2way it either goes in l1 or l2 ?
@scottspeig
@scottspeig Жыл бұрын
If I connect two switches up in a light switch as per this video (cable and switches already installed), but it trips the breaker switch, what might be the cause (all the wires from the switch are hidden, but appears someone disconnected one of the switches... Moved in recently...)
@SeanyyBoy_
@SeanyyBoy_ 7 ай бұрын
Does it matter if the strappers go L1 to L1 & L2 to L2 rather than in your example?
@user-yp9bx9tj3r
@user-yp9bx9tj3r 3 жыл бұрын
This days we can use wireless light switches which is easy to install and will save a lot of materials and time !!!
@paolofriel
@paolofriel 2 жыл бұрын
Hey there, do you have a video to explain 2 gang 2 way switching where all cables are going through a junction box in the loft to control the two separate lights?
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Have a look in this playlist 👍🏻 Wiring Diagrams for Lighting and Motor Circuits kzfaq.info/sun/PL2Ea5r9gxUUfm4SACOSOZigCeSxxC5xaO
@GSHElectrical
@GSHElectrical 2 жыл бұрын
It has 2 gang switches but no joint boxes 👍🏻
@paolofriel
@paolofriel 2 жыл бұрын
@@GSHElectrical thanks for the swift response.
@bilner86
@bilner86 3 жыл бұрын
I have a question, I keep getting told the new 18th edition regs say you should feed the light switch on lighting circuits. Is this true?
@GSHElectrical
@GSHElectrical 3 жыл бұрын
No but it’s often use see the link below. Thanks for commenting. Gaz kzfaq.info/get/bejne/Z61kmbpjqcvVgHU.html
@amphimrca
@amphimrca 3 жыл бұрын
Man you are my last hope.. Question: staircase two way sw. If DB is next to bottom switch and lamp next to top switch ..if 3 core cabe used ,can I use third core as Neutral..?thank you very much👍
@Hiccup77
@Hiccup77 3 жыл бұрын
Isn't this the old way of wiring? My AM2 the preferred method was to come from the CU to the 1st switch, thus introducing a neutral at the switch for those 'smart' switches. and you don't have a permanent live at the rose?
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Taking the Feed (Supply) to the Light Switch the 2 Plate Method kzfaq.info/sun/PL2Ea5r9gxUUevU9gv8lizD53aYvwiJ5qr YES 🦾
@Hiccup77
@Hiccup77 3 жыл бұрын
Just watching the '2 plate' now. I must say, I wish EVERY spark was as methodical and exacting as you guys are. I'm forever telling younger younger people to watch and subscribe to your vids. Keep up the great work Gaz and team.
@ianstanley5157
@ianstanley5157 2 жыл бұрын
What we do is take a live from the circuit breaker to the common of switch 1 ... then we run 2 wires the same colour from switch 1 "L1" to "L1" of switch 2 and the same with "L2" from switch to "L2" of switch 2 ... then from the common of switch to the light fitting.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
That’s the method we use when wiring in pvc singles in conduit 👍🏻
@andysims4906
@andysims4906 3 жыл бұрын
With the common wire going back to the old colours we was always taught that red was common and blue and yellow was the straps..moving on to the new colours We use brown for common and black and gray for the straps. In practice I find about 50% of other electricians do the same and about 50% use the black for common. I have even seen the grey used for common.
@JasperJanssen
@JasperJanssen 2 жыл бұрын
In the Netherlands, we use black for all switched lines - so both strappers and the common and the wire to the light fitting ould be black.
@thomashuscroft2524
@thomashuscroft2524 3 жыл бұрын
I thought it was live to common on first switch L1 - L1, L2-L2 and then common on the second switch goes to ceiling rose. Is this wrong or just a differnet method?
@NoDissasemble
@NoDissasemble 3 жыл бұрын
I've always used that method too. It seems far simpler to follow. Advantage I see in Gary's method is you always have perm live on the same terminal in both switches. Bit easier to supply powered smart switches you could run a separate neutral, or use 3+E and 4+E drops with a neutral core instead. With the common live 1st switch method the live swaps between L1 and L2 at the second switch so would have to take into account.
@leem270
@leem270 2 жыл бұрын
Done this task 2-3 times in college and they have never explained why it works how you have explained haha, Starting to get worried I’m not being taught properly 🤦‍♂️
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for watching and commenting good luck with your training 👍🏻 Gaz
@neil6438
@neil6438 3 жыл бұрын
Or just take a 3 core & cpc from each switch to light, common to loop in terminal in light, other common to sw line in light and join each set of strappers in a terminal block.
@johnoregan1738
@johnoregan1738 Жыл бұрын
Does it matter between switches if you go L1 to L2 with the strappers does it have to be L1 to L2 and L2 to L1 or can it be L1 to L1 etc
@GSHElectrical
@GSHElectrical Жыл бұрын
No 👍🏻
@paulcurtis1901
@paulcurtis1901 3 жыл бұрын
How would you add a smart switch to this ??
@ab-zo4kw
@ab-zo4kw 3 жыл бұрын
a bulb went off and now the entire circuit behind it stoped working (lights only), other lights around the house work fine. my main unit has only one switch for all the lights. none of the light switches have fuses. how can i troubleshoot this ?
@Candisa
@Candisa 3 жыл бұрын
Watching this from Belgium, I can see how it works but it makes no sense to me why it would be done this way (it also wouldn't work on two-way dimmers since those require permanent line on the COM). This is how we do it (leaving out earth in this description): Two-way 1: Cable to light: blue with a brown sleeve to COM as switched line, brown as permanent line to a Wago behind the switch. Cable to next switch: brown in that same wago (permanent line), black and grey in L1 and L2 (we call them what translates as "changeover wires"). Two-way 2: brown to COM, black and grey in L1 and L2. In this situation Two-way 2 can be replaced by a two-way dimmer since it has the permanent line already going to COM. By switching brown and brown-sleeved blue it is also possible to put a dimmer in place of the first switch instead. It is also becoming more and more standard in new installs here (apart from many people now installing teleruptor systems instead of two-way switching) to use quintuple wiring in 2.5mm² (green and yellow, blue, brown, grey, black) instead, which futureproofs the installation by bringing neutrals in the backboxes (we then use the black or grey wire as the switched line between the light and first switch). Bringing neutrals to the switches allows one of them to later be replaced by a wireless switch-receiver without the need for batteries or stored kinetic energy, and using 2.5mm² allows the lighting circuit to be converted later to a mixed circuit by simply installing a larger backbox and (an) extra socket(s) at any switch location. Sockets at switch-level in new installations are being fased out because of aesthetic reasons, but many people still like to add them in later to plug in the vacuum cleaner or a battery/phone charger without bending down to the low-level sockets.
@bradreeve6233
@bradreeve6233 3 жыл бұрын
Find it so much easier to feed every switch first with switch lines to light with 3 core between switches on 2 way
@bradreeve6233
@bradreeve6233 3 жыл бұрын
@Brian Gower crazy really hope to work out there in future
@gw6056
@gw6056 Ай бұрын
So if you have plastic switches with no earth connection I can use 3 core wire Instead of this 4 wire cable....colouring them appropriately of course...there all live anyway to the 2nd switch ..
@mango3586
@mango3586 3 жыл бұрын
you should be a teacher only joking nice video
@cman9219
@cman9219 Жыл бұрын
Is therr somewhere to download them sheets i would love to draw them out for practice
@GSHElectrical
@GSHElectrical Жыл бұрын
The link is in the description 👍🏻
@GSHElectrical
@GSHElectrical Жыл бұрын
☑️ Link below is to the images used in this series of videos on lighting wiring diagrams 1drv.ms/b/s!As2jEnZePpD0iXUBdgpj18aZMvY8?e=VLolVV
@shingkwongkwan5700
@shingkwongkwan5700 2 жыл бұрын
Very good. Thank you.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Massive thanks for watching 👍🏻
@olivkakry1533
@olivkakry1533 2 жыл бұрын
Hello how you connect this
@Sudds1888
@Sudds1888 3 жыл бұрын
Why not use twin brown in this instance?
@GSHElectrical
@GSHElectrical 3 жыл бұрын
We do at Tresham College - however contractors and many other colleges do not hence the using of brown and blue 👍. Thanks for commenting Gaz
@burnie497
@burnie497 Жыл бұрын
And what do I do if three wires are red and an earth wire
@effervescence5664
@effervescence5664 3 жыл бұрын
So strange looking at the 3 plate method, never ever use it. Always end up taking 2 core to a switch for live and neutral and 3 core between then 2 core back up. Just because of smart switches or other accessories that people quite often want to add later.
@oldbutstillcurious3615
@oldbutstillcurious3615 2 жыл бұрын
Thanks for the idea.? Do you mean loop between switches with a 3-core, then just 2-core from switch to light? Just thinking that a 3-core between switch and a light (ceiling rose) would allow the fitting an additional item that will need a permanent live eg.timed fan.
@m101ist
@m101ist 2 жыл бұрын
I ⚠️ it's easy to remember that the strappers is a three core + the CPC cable that goes in between the two two-way switches. 😳
@khorasanarmy1
@khorasanarmy1 3 жыл бұрын
Why not bring the Line to the common and connect the strappers to L1 & L2?
@piratedprivacy9052
@piratedprivacy9052 3 жыл бұрын
That other format of wiring will require the S/L in the 1st switch plate, needing a wire-joint somewhat, with the COM(S/L) from the 2nd switch plate. Its also widely used in certain BS based countries... But the demo in the video is rather practical as all wires is terminated directly into the switch terminals themselves, thus eliminating extra wire joints behind the switches.
@Candisa
@Candisa 3 жыл бұрын
This is how we do it in Belgium, probably most of Europe. However I hope this discussion about two-way (+intermediate) switching can become a part of history in favor of (imho far superior) teleruptor systems.
@jaypowell9786
@jaypowell9786 3 жыл бұрын
Yes i can’t seem to get my head around it, why don’t you take your brown (line) to common??? Also can you do a video on 2 way lighting when the switches are fed would be a massive help please👍🏼
@cjhification
@cjhification 3 жыл бұрын
I thought grey was always common, and black and brown were used as the "brown" wires, as brown is brown, and black is old brown, not to say the black shouldn't be sheathed brown, but it just seemed sensible logic to me.
@memylastname9972
@memylastname9972 3 жыл бұрын
Black is the old blue not the old brown.
@cjhification
@cjhification 3 жыл бұрын
@@memylastname9972 you right, red was the old brown, what was I thinking.
@jacksoncroyce6063
@jacksoncroyce6063 Жыл бұрын
The common on a one way switch is permanent live but when a 2 way switch is used the common becomes secondary live and either L1 or L2 becomes the permanent live, Why is this, why wouldn't common be used as permanent live at all times even if it means just renaming the terminals? Seems odd to change the meaning.
@busman2000
@busman2000 3 жыл бұрын
I do wish you would teach taking the service to the switch and not the ceiling rose, then you aren't phaffing about in hot roof spaces.
@jaypowell9786
@jaypowell9786 3 жыл бұрын
Also why don’t you just take the brown (line) to the common keeps it much more simple why do you need a permanent at a switching terminal (L1)??!!????
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Brown to brown black to common 🦾
@stevensmith4449
@stevensmith4449 3 жыл бұрын
I guess intermediates next?
@stupot_64
@stupot_64 3 жыл бұрын
Same circuit, just with an intermediate switch on the brown and grey conductors. An intermediate switch just goes from === to =x= when switched.
@stevensmith4449
@stevensmith4449 3 жыл бұрын
So what do you do with the common! I do know!
@stupot_64
@stupot_64 3 жыл бұрын
@@stevensmith4449 It just gets crimped through.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Yes it is. Thanks for watching 🦾
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Wiring Diagram 2 Way & Intermediate Switching of a Lighting Circuit 3 Plate Method Connections kzfaq.info/get/bejne/gdBzobujsrLanac.html
@yulimust8931
@yulimust8931 2 жыл бұрын
really good explanation, thank you
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks
🍕Пиццерия FNAF в реальной жизни #shorts
00:41
Backstage 🤫 tutorial #elsarca #tiktok
00:13
Elsa Arca
Рет қаралды 43 МЛН
The Noodle Picture Secret 😱 #shorts
00:35
Mr DegrEE
Рет қаралды 29 МЛН
Two Way Switching Explained - How to wire 2 way light switch
7:05
The Engineering Mindset
Рет қаралды 8 МЛН
The Best 3 Way Switch Explanation Ever!
11:49
Terry Peterman
Рет қаралды 4,1 МЛН
Two way light switching explained
7:03
Ultimate Handyman
Рет қаралды 832 М.
🍕Пиццерия FNAF в реальной жизни #shorts
00:41