You did not adjust the charging voltage sir? The problem may just repeat it self in the future
@sultanhussain60513 күн бұрын
For on load test should we required to turn off radar equipment etc ...kindly reply
@randynotarte99436 күн бұрын
Sir paano Yung dalswang g/e nka parallel tapos pag tsnggalen Ang load Ng Isang g/e nag prefential trip
@pogssss505824 күн бұрын
Thank You Sir,
@gichurehmandrew5450Ай бұрын
My experience with Egyptian pilots was bad. From push back it was all the way into airborne - no taxing. Then before landing there was this sharp right corner one would think the runway was there only to continue for another like five kilometres to it. The female hostess was unfriendly. Cairo itself was noisy 24/7 with vehicles scooters and bicycles hooting. Way back the Egyptian airport security was also rough. God forbid i wouldn't want to go back to Cairo.
@marinafrascella7613Ай бұрын
I am sorry you had a bad experience...the flight I took was as smooth as silk,the crew,helpful ,and since I am Roman,I didn t mind the cheerful noisy streets in Cairo...I wish I could go back,right now
@vladimirshandrenko5139Ай бұрын
Thanks a lot
@erabhishekgupta7651Ай бұрын
Hello friend did you do the blackout in ship for installing the main circuit breaker please tell me..
@leckylouieАй бұрын
No, we didnt blackout the ship. the breaker was for ESB and isolated to MSB prior replacement.
@erabhishekgupta7651Ай бұрын
Exide battery performance is good and quality also..
@vladimirshandrenko5139Ай бұрын
Good explanation. Thanks a lot.
@marlonbulgado5021Ай бұрын
thank you sir sa informative information,tanong ko lang yung AC sa control room ayaw lumamig at lagi mataas yung HP side?
@leckylouieАй бұрын
pag mataas na ung high pressure ay may problema na cooling system.. try nyo linisan tapos pwede nyo lagyan ng hangin pra matanggal mga kalawang sa linyada. madalas walang problema sa condenser tube.ang problema ay ung inlet at outlet cooling pipe.
@nvrs.kaba4ok584Ай бұрын
How to lap nozzle hull?
@musicforlife7777Ай бұрын
❤
@suelloasoy2466Ай бұрын
ok lang ba tatanggalin ung mga wire kahit naka ahead ung throttle or mamatay ung command ng throttle sa patongo sa engine?
@Hayatikavak1969Ай бұрын
Good video, thanks Lecky 🙏👏👍🤝
@leckylouieАй бұрын
thank you very much
@muhammetayana95882 ай бұрын
Hello from Türkiye. Your videos are really very informative. Thank you for your efforts.🙏 Your channel will grow up i am sure for it. Have a nice day
@leckylouieАй бұрын
thank you sir. keep watching
@user-ln9rj4pw9m2 ай бұрын
sir good day po! ask ko lang sana yung alborg boiler ko dito, may nag aappear sa touch screen display nya na "comm. error signal" offline 1 parang ganun ang nag aappear sa screen, tapos nilagay ko sa emergency mode pero ayaw mag fire sa emergency mode, ok naman ang oil pressure, sinunod ko naman ang procedure, may ignition naman sya pero ayaw mag fire..hndi umiilaw yung flame scanner indication nya..anything po na maisuggest nyo sa akin sir to solve the problem..thank you.
@leckylouie2 ай бұрын
sir,,paki check mo sa loob ng panel ung controller nya kung may offline 1. try mo muna sir off ung main power ng 5mins then try mo ulit start. check mo isa isa parameters setting sa unisab. sa manual baka meron kayo copy ng parameters setting.minsan kasi nagkaka error ung panel lalo kapag mainit na panahon.
@user-ln9rj4pw9m2 ай бұрын
@@leckylouiecge sir check ko bukas, ang init kasi ng panahon ngayon sir kaya cguro nagloloko ang mga electronics..try ko irestart ang nain power bukas.
@ryanmangubat2 ай бұрын
May video ka sir sa pag charge naman sa air con . Reefer pra sa accomodation
@leckylouie2 ай бұрын
salamat po sa request sir
@bryansayon21522 ай бұрын
paano po sir magkuha ng running hours sa ganyan model?
@leckylouie2 ай бұрын
sir,ung running hours namin ay sa ECR alarm computer po namin kinukuha. naka program na po doon at naka~sync ang mga purifier running hours..
@fatihh71802 ай бұрын
Thanks for sharing your knowledge and experience. Please keep sharing troubleshootings.
@leckylouie2 ай бұрын
thank you sir.keep watching
@fatihh71802 ай бұрын
@@leckylouie Alwaysssss👍
@francisglenndimacuha40302 ай бұрын
Thank you for the impormative video.
@leckylouie2 ай бұрын
keep watching.
@thanhtutaungetr2 ай бұрын
Thanks for your vidoe
@leckylouie2 ай бұрын
thank you.keep watching
@htayhtay84742 ай бұрын
🎉🎉🎉thanks
@htayhtay84742 ай бұрын
🎉🎉🎉thanks
@htayhtay84742 ай бұрын
🎉🎉🎉thanks
@AndreBonDalen3 ай бұрын
Sir gud evening my some questions lang po sana ako regarding sa boiler
@hareshchitroda40193 ай бұрын
Please make video in English language sir or English subtitles
@leckylouie3 ай бұрын
noted sir
@ivanfmartinezm3 ай бұрын
Name of the vessel please
@andrewtierney53963 ай бұрын
Really great video.
@leckylouie3 ай бұрын
thank you sir.. keep watching
@rjcalingasan38613 ай бұрын
Suction side ka ng comressor nagkarga sir?
@javadriahi40143 ай бұрын
Nice👍
@fireflameai75403 ай бұрын
Very good pare. Thanks for education video 👍🏻
@leckylouie3 ай бұрын
Many many thanks
@ricorubillar52083 ай бұрын
Helpfull infirmation boss thanks
@leckylouie3 ай бұрын
Welcome
@pawanravindrasonawane47703 ай бұрын
fantastic work and efforts, please make more videos in such deep details thankyou
@leckylouie3 ай бұрын
thank you sir..
@pawanravindrasonawane47703 ай бұрын
@@leckylouie looking forward to see more machinery working videos and system operations
@hasarallife56843 ай бұрын
It’s fantastic lesson. Really appreciated for your valuable time you for us
@leckylouie3 ай бұрын
thank you sir..keep watching
@anasamery21863 ай бұрын
Thank you. I have a question after I disconnected the supply from the main power in the case of the test.... After the generator starts and supplies the emergency switch board, what will be the fate of the electricity generated during the emergency, because in the case of the examination, the main generator is the one that supplies the power,
@leckylouie3 ай бұрын
Sir, during the test of Emergency Generator, the TIE BREAKER between MSB and ESB will automatically open. then the MSB has still normal power. But the ESB is totally blackout during the test and the back up Emergency generator will start and gives supply to ESB.
@yaduveshkumar69334 ай бұрын
Hello friends in AutoChief® C20 Telegraph showing communication error and my printer doesn't got print. Any idea how to resolve and get print on Telegraph printer
@ferdinandusamuntoda85294 ай бұрын
You too fast
@malakadananjaya20464 ай бұрын
Great vidoe eto
@khal-elbuentino36134 ай бұрын
Sir yung provision plant ko iing ang suction line normal po ba yn ? Malpit na sa compressor
@leckylouie4 ай бұрын
hindi normal yan. baka kulang ng refrigerant or may problema na ung expansion valve. check mo ilan ung suction pressure mo dapat nasa normal limit lage.
@cocusnucipera74194 ай бұрын
Nice one lecky, safe sailing.
@leckylouie4 ай бұрын
thank you sir,, keep.watching
@phyowin52884 ай бұрын
thanks , very clear message
@leckylouie4 ай бұрын
thank you, highly appreciated your comment. keep watching Sir.
@phyowin52884 ай бұрын
thanks so much
@beantjitsingh18304 ай бұрын
Dear Mr. Louie, This is very informative. Would appreciate if you can clear my one doubt regarding emergency power supply to steering control system on the bridge in case of blackout. My question is, Are both the steering controls connected to emergency switchboard or is it only one connected to ESB just like only one steering motor is connected to ESB?
@leckylouie4 ай бұрын
Hi sir, only one steering gear system is connected to ESB. it is enough to steer ng ship when only Emergency Generator is running.
@dilpalsingh11804 ай бұрын
Low lube oil level alarm activation will enable standby motor to start…u haven’t mention that
@leckylouie4 ай бұрын
you are correct sir that stanby pump will automatically start.
@TheDingir4 ай бұрын
Thank you for your job
@user-ln9rj4pw9m4 ай бұрын
sir, yung aalborg ko dito palagi flame failure kpag vlsfo at biofuel ang gamit pero kpag diesel wala nman problema..ano po ba ang tamang air/fuel ratio nya para hndi sya mag flame failure?salamat.
@leckylouie4 ай бұрын
pwede mo check sa boiler commision data na nasa manual kung ano air/fuel ration ng boiler nyo. Pwede mo din i try na. babaan muna yung air ratio during firing sequence. Compare mo din ung oil pressure kapag naka.diesel at pag naka vlsfo. madami kasing factor kung bakit sya mag flame failure.
@arneldemecillo37044 ай бұрын
idol pag rack out need pa i off ang acb
@leckylouie4 ай бұрын
for safety reason much better na naka-Off. pero mag automatic OFF din naman kapag rack-out.
@user-vs5ul8bu7y4 ай бұрын
Boss paano kng dko mapaabot ng -18 pwd ko bng mag dalawang compresor para maabot nia -18 o -19
@leckylouie4 ай бұрын
pwede gamitan ng dalawang compressor pero base sa makers manual ay maximum of 30mins lang pwedeng i-service ng sabay ang compressor.kung kailangan lang habulin ang room temperature lalo pag bagong lagay ng provision. may connection ang dalawang compressor na pang balancing ng pressure na kailangan buksan pag sabay naka service. pero ang design kasi ay kaya lang ng isang compressor,pag dalawa na.meaning may abnornal sa system.