Emergency Generator Batteries
14:12
Main Engine Routine Inspection.
3:08
Lifeboat Batteries
11:00
Жыл бұрын
Fuel Change-over procedure
9:42
Жыл бұрын
Пікірлер
@FirstLast-ue6zu
@FirstLast-ue6zu 2 күн бұрын
You did not adjust the charging voltage sir? The problem may just repeat it self in the future
@sultanhussain6051
@sultanhussain6051 3 күн бұрын
For on load test should we required to turn off radar equipment etc ...kindly reply
@randynotarte9943
@randynotarte9943 6 күн бұрын
Sir paano Yung dalswang g/e nka parallel tapos pag tsnggalen Ang load Ng Isang g/e nag prefential trip
@pogssss5058
@pogssss5058 24 күн бұрын
Thank You Sir,
@gichurehmandrew5450
@gichurehmandrew5450 Ай бұрын
My experience with Egyptian pilots was bad. From push back it was all the way into airborne - no taxing. Then before landing there was this sharp right corner one would think the runway was there only to continue for another like five kilometres to it. The female hostess was unfriendly. Cairo itself was noisy 24/7 with vehicles scooters and bicycles hooting. Way back the Egyptian airport security was also rough. God forbid i wouldn't want to go back to Cairo.
@marinafrascella7613
@marinafrascella7613 Ай бұрын
I am sorry you had a bad experience...the flight I took was as smooth as silk,the crew,helpful ,and since I am Roman,I didn t mind the cheerful noisy streets in Cairo...I wish I could go back,right now
@vladimirshandrenko5139
@vladimirshandrenko5139 Ай бұрын
Thanks a lot
@erabhishekgupta7651
@erabhishekgupta7651 Ай бұрын
Hello friend did you do the blackout in ship for installing the main circuit breaker please tell me..
@leckylouie
@leckylouie Ай бұрын
No, we didnt blackout the ship. the breaker was for ESB and isolated to MSB prior replacement.
@erabhishekgupta7651
@erabhishekgupta7651 Ай бұрын
Exide battery performance is good and quality also..
@vladimirshandrenko5139
@vladimirshandrenko5139 Ай бұрын
Good explanation. Thanks a lot.
@marlonbulgado5021
@marlonbulgado5021 Ай бұрын
thank you sir sa informative information,tanong ko lang yung AC sa control room ayaw lumamig at lagi mataas yung HP side?
@leckylouie
@leckylouie Ай бұрын
pag mataas na ung high pressure ay may problema na cooling system.. try nyo linisan tapos pwede nyo lagyan ng hangin pra matanggal mga kalawang sa linyada. madalas walang problema sa condenser tube.ang problema ay ung inlet at outlet cooling pipe.
@nvrs.kaba4ok584
@nvrs.kaba4ok584 Ай бұрын
How to lap nozzle hull?
@musicforlife7777
@musicforlife7777 Ай бұрын
@suelloasoy2466
@suelloasoy2466 Ай бұрын
ok lang ba tatanggalin ung mga wire kahit naka ahead ung throttle or mamatay ung command ng throttle sa patongo sa engine?
@Hayatikavak1969
@Hayatikavak1969 Ай бұрын
Good video, thanks Lecky 🙏👏👍🤝
@leckylouie
@leckylouie Ай бұрын
thank you very much
@muhammetayana9588
@muhammetayana9588 2 ай бұрын
Hello from Türkiye. Your videos are really very informative. Thank you for your efforts.🙏 Your channel will grow up i am sure for it. Have a nice day
@leckylouie
@leckylouie Ай бұрын
thank you sir. keep watching
@user-ln9rj4pw9m
@user-ln9rj4pw9m 2 ай бұрын
sir good day po! ask ko lang sana yung alborg boiler ko dito, may nag aappear sa touch screen display nya na "comm. error signal" offline 1 parang ganun ang nag aappear sa screen, tapos nilagay ko sa emergency mode pero ayaw mag fire sa emergency mode, ok naman ang oil pressure, sinunod ko naman ang procedure, may ignition naman sya pero ayaw mag fire..hndi umiilaw yung flame scanner indication nya..anything po na maisuggest nyo sa akin sir to solve the problem..thank you.
@leckylouie
@leckylouie 2 ай бұрын
sir,,paki check mo sa loob ng panel ung controller nya kung may offline 1. try mo muna sir off ung main power ng 5mins then try mo ulit start. check mo isa isa parameters setting sa unisab. sa manual baka meron kayo copy ng parameters setting.minsan kasi nagkaka error ung panel lalo kapag mainit na panahon.
@user-ln9rj4pw9m
@user-ln9rj4pw9m 2 ай бұрын
@@leckylouiecge sir check ko bukas, ang init kasi ng panahon ngayon sir kaya cguro nagloloko ang mga electronics..try ko irestart ang nain power bukas.
@ryanmangubat
@ryanmangubat 2 ай бұрын
May video ka sir sa pag charge naman sa air con . Reefer pra sa accomodation
@leckylouie
@leckylouie 2 ай бұрын
salamat po sa request sir
@bryansayon2152
@bryansayon2152 2 ай бұрын
paano po sir magkuha ng running hours sa ganyan model?
@leckylouie
@leckylouie 2 ай бұрын
sir,ung running hours namin ay sa ECR alarm computer po namin kinukuha. naka program na po doon at naka~sync ang mga purifier running hours..
@fatihh7180
@fatihh7180 2 ай бұрын
Thanks for sharing your knowledge and experience. Please keep sharing troubleshootings.
@leckylouie
@leckylouie 2 ай бұрын
thank you sir.keep watching
@fatihh7180
@fatihh7180 2 ай бұрын
@@leckylouie Alwaysssss👍
@francisglenndimacuha4030
@francisglenndimacuha4030 2 ай бұрын
Thank you for the impormative video.
@leckylouie
@leckylouie 2 ай бұрын
keep watching.
@thanhtutaungetr
@thanhtutaungetr 2 ай бұрын
Thanks for your vidoe
@leckylouie
@leckylouie 2 ай бұрын
thank you.keep watching
@htayhtay8474
@htayhtay8474 2 ай бұрын
🎉🎉🎉thanks
@htayhtay8474
@htayhtay8474 2 ай бұрын
🎉🎉🎉thanks
@htayhtay8474
@htayhtay8474 2 ай бұрын
🎉🎉🎉thanks
@AndreBonDalen
@AndreBonDalen 3 ай бұрын
Sir gud evening my some questions lang po sana ako regarding sa boiler
@hareshchitroda4019
@hareshchitroda4019 3 ай бұрын
Please make video in English language sir or English subtitles
@leckylouie
@leckylouie 3 ай бұрын
noted sir
@ivanfmartinezm
@ivanfmartinezm 3 ай бұрын
Name of the vessel please
@andrewtierney5396
@andrewtierney5396 3 ай бұрын
Really great video.
@leckylouie
@leckylouie 3 ай бұрын
thank you sir.. keep watching
@rjcalingasan3861
@rjcalingasan3861 3 ай бұрын
Suction side ka ng comressor nagkarga sir?
@javadriahi4014
@javadriahi4014 3 ай бұрын
Nice👍
@fireflameai7540
@fireflameai7540 3 ай бұрын
Very good pare. Thanks for education video 👍🏻
@leckylouie
@leckylouie 3 ай бұрын
Many many thanks
@ricorubillar5208
@ricorubillar5208 3 ай бұрын
Helpfull infirmation boss thanks
@leckylouie
@leckylouie 3 ай бұрын
Welcome
@pawanravindrasonawane4770
@pawanravindrasonawane4770 3 ай бұрын
fantastic work and efforts, please make more videos in such deep details thankyou
@leckylouie
@leckylouie 3 ай бұрын
thank you sir..
@pawanravindrasonawane4770
@pawanravindrasonawane4770 3 ай бұрын
@@leckylouie looking forward to see more machinery working videos and system operations
@hasarallife5684
@hasarallife5684 3 ай бұрын
It’s fantastic lesson. Really appreciated for your valuable time you for us
@leckylouie
@leckylouie 3 ай бұрын
thank you sir..keep watching
@anasamery2186
@anasamery2186 3 ай бұрын
Thank you. I have a question after I disconnected the supply from the main power in the case of the test.... After the generator starts and supplies the emergency switch board, what will be the fate of the electricity generated during the emergency, because in the case of the examination, the main generator is the one that supplies the power,
@leckylouie
@leckylouie 3 ай бұрын
Sir, during the test of Emergency Generator, the TIE BREAKER between MSB and ESB will automatically open. then the MSB has still normal power. But the ESB is totally blackout during the test and the back up Emergency generator will start and gives supply to ESB.
@yaduveshkumar6933
@yaduveshkumar6933 4 ай бұрын
Hello friends in AutoChief® C20 Telegraph showing communication error and my printer doesn't got print. Any idea how to resolve and get print on Telegraph printer
@ferdinandusamuntoda8529
@ferdinandusamuntoda8529 4 ай бұрын
You too fast
@malakadananjaya2046
@malakadananjaya2046 4 ай бұрын
Great vidoe eto
@khal-elbuentino3613
@khal-elbuentino3613 4 ай бұрын
Sir yung provision plant ko iing ang suction line normal po ba yn ? Malpit na sa compressor
@leckylouie
@leckylouie 4 ай бұрын
hindi normal yan. baka kulang ng refrigerant or may problema na ung expansion valve. check mo ilan ung suction pressure mo dapat nasa normal limit lage.
@cocusnucipera7419
@cocusnucipera7419 4 ай бұрын
Nice one lecky, safe sailing.
@leckylouie
@leckylouie 4 ай бұрын
thank you sir,, keep.watching
@phyowin5288
@phyowin5288 4 ай бұрын
thanks , very clear message
@leckylouie
@leckylouie 4 ай бұрын
thank you, highly appreciated your comment. keep watching Sir.
@phyowin5288
@phyowin5288 4 ай бұрын
thanks so much
@beantjitsingh1830
@beantjitsingh1830 4 ай бұрын
Dear Mr. Louie, This is very informative. Would appreciate if you can clear my one doubt regarding emergency power supply to steering control system on the bridge in case of blackout. My question is, Are both the steering controls connected to emergency switchboard or is it only one connected to ESB just like only one steering motor is connected to ESB?
@leckylouie
@leckylouie 4 ай бұрын
Hi sir, only one steering gear system is connected to ESB. it is enough to steer ng ship when only Emergency Generator is running.
@dilpalsingh1180
@dilpalsingh1180 4 ай бұрын
Low lube oil level alarm activation will enable standby motor to start…u haven’t mention that
@leckylouie
@leckylouie 4 ай бұрын
you are correct sir that stanby pump will automatically start.
@TheDingir
@TheDingir 4 ай бұрын
Thank you for your job
@user-ln9rj4pw9m
@user-ln9rj4pw9m 4 ай бұрын
sir, yung aalborg ko dito palagi flame failure kpag vlsfo at biofuel ang gamit pero kpag diesel wala nman problema..ano po ba ang tamang air/fuel ratio nya para hndi sya mag flame failure?salamat.
@leckylouie
@leckylouie 4 ай бұрын
pwede mo check sa boiler commision data na nasa manual kung ano air/fuel ration ng boiler nyo. Pwede mo din i try na. babaan muna yung air ratio during firing sequence. Compare mo din ung oil pressure kapag naka.diesel at pag naka vlsfo. madami kasing factor kung bakit sya mag flame failure.
@arneldemecillo3704
@arneldemecillo3704 4 ай бұрын
idol pag rack out need pa i off ang acb
@leckylouie
@leckylouie 4 ай бұрын
for safety reason much better na naka-Off. pero mag automatic OFF din naman kapag rack-out.
@user-vs5ul8bu7y
@user-vs5ul8bu7y 4 ай бұрын
Boss paano kng dko mapaabot ng -18 pwd ko bng mag dalawang compresor para maabot nia -18 o -19
@leckylouie
@leckylouie 4 ай бұрын
pwede gamitan ng dalawang compressor pero base sa makers manual ay maximum of 30mins lang pwedeng i-service ng sabay ang compressor.kung kailangan lang habulin ang room temperature lalo pag bagong lagay ng provision. may connection ang dalawang compressor na pang balancing ng pressure na kailangan buksan pag sabay naka service. pero ang design kasi ay kaya lang ng isang compressor,pag dalawa na.meaning may abnornal sa system.
@alexsv9401
@alexsv9401 4 ай бұрын
interesting video. what is the name of this port?
@thutatin3552
@thutatin3552 4 ай бұрын
Thanks