Man, just entering the garage with those CO levels was very stupid. I'm glad you survived.
@basspig18 күн бұрын
Diesel generators and the conundrum of being used as a emergency power source. The thing is the generator needs to be rated to handle big startup loads like water pumps air conditioning but a lot of the time it's running at less than 10% of its capacity so you get the wet stacking problem. My solution was to use the diesel generator to charge batteries which run an inverter that also get charged with solar panels. The generator only runs when there is insufficient solar and foot for several days in a row but the generator runs at near full capacity so it gets up to full temperature and alleviates any problems with wet stacking.
@JohnDoe-l3d20 күн бұрын
I really need your help!!!
@basketballjones678221 күн бұрын
I guess that clears up the question as to whether a tree makes noise when it falls if nobody is around.
@diyanich26 күн бұрын
What paint have you used on your CCK?
@basspig26 күн бұрын
Suggestion put Hardie board on the walls and ceiling. This will give you some fire resistance in case something goes seriously wrong.
@moondogdieselworks388327 күн бұрын
It takes months of running with no load to start wet stacking.
@moondogdieselworks388327 күн бұрын
It takes months of running with no load to start wet stacking.
@Diy-For-LifeАй бұрын
Awsome videos and restoration work! So wondering if you can help answer. What kinds of thd are you getting and also what kind of voltage spike are you getting when a large load is dropped off the generator. How high does the voltage spike?
@f-j-Services2 ай бұрын
I think it would be cool to synchronize them together, if one shuts off, a breaker will trip and full load on the other. Why not lol?
@JoeJennings-ic1jo2 ай бұрын
By chance do you still have a wiring diagram
@mikeprice18162 ай бұрын
Cool man
@user-io1jy8ec7d2 ай бұрын
Where do I get the onan color paint?
@user-io1jy8ec7d3 ай бұрын
Where did you get your paint for the onan?
@larsnordjohansen52004 ай бұрын
I have the dataplat also.
@larsnordjohansen52004 ай бұрын
I have one. Had start on it today.
@rodneyswearingen10204 ай бұрын
Its just condensation like a gas engine makes due to no load.
@RustyShacklefordPocketSand4 ай бұрын
What is that gorgeous green paint called?
@TheSoloAsylum5 ай бұрын
I have a MEP-003A Onan generator and sure would like to know where you are finding engine parts. I've got an oil pump with the gear broke off and can't find one.
@jjjj-uf4bw3 ай бұрын
I find my parts on the internet and through several online vendors such as Onanparts.com.
@DeganH5 ай бұрын
Is this real 😨
@jjjj-uf4bw3 ай бұрын
Maybe 😆
@jeffanthony54345 ай бұрын
Hey Johnny, what kind of transfer switches are you using to alternate between your big gen (djc) and the smaller backup unit? Love your videos (from Nova Scotia)!] Thanks!
@jjjj-uf4bw3 ай бұрын
Hi Jeffanthony5434 - I home brewed "generator switch box" to alternate between the DJC and JB. The main switch is from an Onan OT 70 ATS, but everything else is pieced together. The generator switch can be wirelessly switched up to 100 feet using a key fob. My house is 50 feet away from the generator room.
@jeffanthony54343 ай бұрын
@jjjj-uf4bw thank you! Your garage full of sets makes me jealous every time I see it! I tried to make a deal on a 12 kw djc but it was about 12 hours from here and he sold it just before I got ahold of him.
@clachaine5 ай бұрын
Can you hook up computers or electronics to the power output of the Onan 3.0 DJA ? Thank you. Great channel....
@user-bn2yw8dk4k5 ай бұрын
What part numbers are you using for both the preheated and the glow plug? I have several 12djc units that the plugs and preheated are all fried on and can't find numbers on them
@jbtaiseytransport96596 ай бұрын
I have a jc propane 15kw was running great now won’t start would love some insight the over crank lights up on its own after you reset it and not trying to start at all
@user-rc5bj8jy7r6 ай бұрын
Yo tengo uno igual con el armazon cerrado.es mep003A lo compre sin la bomba inyectora y arranque.me podrias pasar el modelo arranque .aca busque y el modelo prestolite 24 v..y si podes pasar modelo bomba inyectora.quedo muy practico con el carro con ruedas lo practico que pase por las puertas medida promedio .pasar por todos lados sin necesitar pasar por portones.
@JoshKilen7 ай бұрын
nice job, whats your opinion one a onan 6.0DJE vs. cummins onan 7.5HDKAL-1F vs. a 6Kw light plant generator?
@jimsbagels19917 ай бұрын
Confirmed, Johnny C is moving to Nigeria
@jjjj-uf4bw7 ай бұрын
🤣
@bigbillyblue7 ай бұрын
I know this is an old video, but did you ever do a video on the little panel you made up with the amp meters? I'd love to see that in detail, its really awesome!
@jeffanthony54348 ай бұрын
Every time I see your setup and all of the sets you have I get jealous 😊
@RandomMichael8 ай бұрын
80% or more load recommended to prevent wet stacking,
@jimciancio90059 ай бұрын
Nicely Done! I love the air cooled Onan diesels, I own a single cylinder version I restored from being stuck from decades of sitting outside under tarps. Mine is unbelievable on how little fuel they burn but it is a single cylinder, I'm sure the twin is a little more thirsty than the single? But it is definitely much smoother without the 3 dead strokes of the single @1800 rpms. But Onan knew this was a problem with the singles and put a boost cap in the field circuit to increase the output on the 3 dead strokes knowing the rpms would drop off a little bit. They had a particular name for the cap and points system they used for that. But I forget that by now Lol.
@1vester19 ай бұрын
wet stack compression not right valves injectors something not right running at 1800 rpm
@nauticalman22379 ай бұрын
very nice job excellent detail throughout the process
@tylerp98959 ай бұрын
What is one worth?I have one in good running shape for sale on a trailer to boot
@mickwolf10779 ай бұрын
I picked up a 5.5kva genset that hasn't run for 12 years and in its 1000 hours it hardly got loaded. I loaded it up with 3kw and man sparks and junk flew out the exhaust pipe, it glowed bright yellow looking in there and had a flame coming out once it was shut down. That's a bad case of wet stacking where the stuff stacked layer upon layer. Now i gotta run it for several hours loaded to clean it out. I might post up a vid of it.
@1vester19 ай бұрын
wet stack not good something not right low compression fuel not burning clean.
@westentrance9 ай бұрын
Brand new, out of the box mine would not stay running for more than 5 seconds. Fresh gas, fresh oil, tried every trick in the book but after 30-plus attempts I finally called their 1-800 customer service number. Was immediately informed that the units are made in China and that during shipping sometimes sediment can find its way into the carb preventing continuous fuel flow. The way they told me that right away seems to imply that it’s been a common problem. They said I should remove the carb, disassemble and clean it. Yeah right. Option two was to spray carb cleaner then starting fluid into it but that was a long shot for success. Don’t roll the dice on this thing. Spend a few more bucks and hopefully get something better. I took mine back, they can play carborator mechanic with it.
@JoshKilen9 ай бұрын
nice job, whats your opinion on the MEP-003a generators?
@patrickcrow50429 ай бұрын
I’ve got this exact genny. All of a sudden, no start. No spark either.
@slicksnewonenow10 ай бұрын
Your Gens are absolutely beautiful! Do you rebuild them?
@jorgitoamaya110 ай бұрын
Hola me funcionaria con maquinas a 220 ?
@wildman464211 ай бұрын
Should've painted it pink like the Hello Kitty AJ....it would have never burned.
@billmoran381211 ай бұрын
Wet stacking is common on diesel generators and other diesel engines that idle or run unloaded for long periods of time. It is a result of low cylinder pressures that allow lubricant oil to bypass the rings because the rings exert less pressure against the cylinder walls. This is especially a problem on air cooled diesels as they have difficulty getting up to operating temperature without sufficient load. Diesels like to have between 70% and 100% load. That’s where they are most efficient. Long idling and low loads can eventually cause stuck rings and glazed cylinder walls. I used to work on locomotives that spent many hours at idle. As part of normal maintenance several times a year, we cleaned out the soot traps in the exhaust manifold. Usually get a 5 gallon bucket full of heavy oily soot, caused by wet stacking. Ocassionally when running a locomotive hard, all that junk would catch fire in the manifold and we’d have flames out the stack!
@Deveak11 ай бұрын
That sucks, was it hose rot or just manufacturer defect/bad hose?
@jjjj-uf4bw11 ай бұрын
Most likely deterioration of the hose. It was old, made in 1997. I say likely since anything that could burn under the hood was affected by the fire.
@Deveak11 ай бұрын
@@jjjj-uf4bw need to keep an eye on mine. I drive a lot of older vehicles. Time claims everything.
@coopershistorygarage280411 ай бұрын
Holy CRAP Johnny C!! You’ve had that Jeep forever. That and the countless Onans it has helped recover. Thankfully, you had it parked outside so it didn’t pose a threat to your house or garages
@jjjj-uf4bw11 ай бұрын
If I parked in the garage, it would have burned down the garage along with my much newer Highlander and my 1964 Ford Falcon and a Corvette in the attached garage along with thousands in tools.
@jeffanthony54348 ай бұрын
@jjjj-uf4bw very lucky!!!
@JoshKilen11 ай бұрын
nice job, to help prevent wetstacking run between 50-75% of it rated load.
@moondogdieselworks388327 күн бұрын
Awesome comment, that is exactly what happened.
@TechOrdinance11 ай бұрын
ok this time we want to see the painting process !!!
@TechOrdinance11 ай бұрын
not the exact same one but very simialr kzfaq.info/get/bejne/gpN0dpR9y7fQloU.html
@TechOrdinance11 ай бұрын
small engine mechanic on youtube has worked on one of these i belive
@TechOrdinance11 ай бұрын
you have got to post your prep and paint process outside of smokstack ive dun a few but they never look as good as yours!!