IT CAN KILL YOU.... that one shock me! Hahaha 600 volts..
@wizlipskings895813 сағат бұрын
Why not use 48 volts batteries to reduce the number of space is occupying Or tubular batteries dont have 48volts?
@wizlipskings895814 сағат бұрын
I used to 12volts is the lowest inverter and 48volts is the high voltage inverter So you mean 60-100volts is under the low voltage category???
@smilinsunsmilinsun805613 сағат бұрын
You are refereeing to inverter system voltage the video is about PV voltage
@wizlipskings895813 сағат бұрын
@@smilinsunsmilinsun8056 or sorry although I found my answer in your other video and I also question for u Der , thanks
@juventineojiki16 сағат бұрын
What is the difference between voltage and current?
@bashirshittu849917 сағат бұрын
Weldone. You forgot to mention shading; It can affect series connected panels
@smilinsunsmilinsun805616 сағат бұрын
@@bashirshittu8499 Yeah that was a good one, Thanks for sharing
@salembrother91517 сағат бұрын
I'm greatful for all your videos. Quite educative.This is my updating school
@smilinsunsmilinsun805616 сағат бұрын
@@salembrother915 Glad you found it useful
@salembrother91517 сағат бұрын
I'm greatful for all your videos. Quite educative.This is my updating school
@AudufenКүн бұрын
I have a question,some persons buy batteries,let's say 2 batteries, start using it and after some time buy another 2 batteries and add, what can you say sir,is it good? Because I feel the old nd new batteries are no longer on same level
@apphandlerКүн бұрын
Thanks for the video. How do you find how many kilowatts hours it generated. I can’t seem to find it with this felicity charge controller. Other charge controllers I’ve used normally display the amount of energy generated.
@smilinsunsmilinsun8056Күн бұрын
@@apphandler Unfortunately it doesn't have a logging system
@portagepete1Күн бұрын
Same thing China
@ndukaakpatiКүн бұрын
I think you should have uploaded this video in one video.. it's hard getting it
@smilinsunsmilinsun8056Күн бұрын
@@ndukaakpati There is time limit on shorts but go the main KZfaq channel and watch the full video
@Ebi_J2 күн бұрын
I didn't know that Smilinsun is here in Nigeria. I thought you were somewhere abroad. Good to know that I can reach out locally.
@deborahomeke40662 күн бұрын
When you get an error 04 at peak sunlight of the day, what could be wrong and what can be done… It keeps flashing red and the amps and watts turns 0 at intervals. Please I await your response. Thanks
@Audufen3 күн бұрын
How do you check for the right place to mount the panels to get maximum sun rays
@oladapoodunayo81913 күн бұрын
My system has not been supplying sufficient electricity. I have already explained this issue to the installer who installed it for me. He mentioned that it is due to the weather.However, yesterday and today, there has been an abundance of sunlight, yet it still did not provide enough electricity. The frustrating aspect is that it was only installed three weeks ago. I kindly request your assistance, sir.
@igokskelvin56493 күн бұрын
What of felicity But boss wetin dey beep na inverter
@MATHCLINIC013 күн бұрын
Very correct boss
@godknows53 күн бұрын
Nigeria is a now a cruise Nation since the inception content creation. They're now leaving skit making to oviously deceiving some people in the world in the name of content creating. For him to jump into solar content creating which he know nothing about, that's means he's exhausted with content.
@julius-jayboy14 күн бұрын
You mean 6 mm.
@user-zj8sn4xv5p4 күн бұрын
Ignorant na life's F9 o! wrong installation from panel down to batteries he is under going monetary pain, needs counseling.😢
@oladapoodunayo81914 күн бұрын
Hello smilingsun I just installed my solar few week ago but now it shutdown between one hour of using and with almost 8hour of charging I don't know what can caused it
@romeoromeo72674 күн бұрын
Good after Sir, please if i have to choose between Cworth and Marstek 48V lithium batteries?
@EsaintTv4 күн бұрын
How long to keep the equalizer connected
@smilinsunsmilinsun80564 күн бұрын
@@EsaintTv Always on
@EsaintTv4 күн бұрын
@@smilinsunsmilinsun8056what about for three 12v agm batteries in parallel do I keep that connected 24/7 ?
@didiermonga43345 күн бұрын
I think it's a bad installation, the one who did it is not a professional
@linetech26515 күн бұрын
I believe people should save themselves the headache......why not just buy a lithium battery 5kwh minimum, for the money spent in buying those batteries.
@michaelakomolafe92494 күн бұрын
This is not the bone of contention from this video. No matter what you buy, poor installation, poor design, substantial products,... will still land you on the same plane of inefficiency and breakdown.
@smilinsunsmilinsun80562 күн бұрын
Correct
@TheToastPeople5 күн бұрын
Sunsynk is a good brand
@olusegunbabarinde69655 күн бұрын
Am a certified solar engineer but I can still say that I learnt one or two. Kudos👍🏽
@scodevicetech5 күн бұрын
Nawadays, electricians take solar jobs as solar experts. 1. Charge controller is very poor 2. No rack poor connections. 3. No breakers, voltage regulator or Spd. 4. Mixing of batteries is 100% no for me. 5. If a good solar Engr. Goes there, I can tell you, 4 batteries might give the client good satisfaction.
@ohiremenvictor51835 күн бұрын
You said it all mr ikenna....most this guy's do not want to professional to their job for them because they feel is too expensive,so they go for cheaper options....I see this alot because I am into the solar field for some good number of years now...God bless you Mr ikenna
@Ukthorncarver5 күн бұрын
May I know how I can contact you Sir?
@paulcheche67975 күн бұрын
Thanks for this information, definitely have to go for the lithium battery despite the price
@chrismurphy73245 күн бұрын
surge protectors will not protect you from a direct lighting strike , they will only protect from impulse , and most if not all inverters have these built in
@chrismurphy73245 күн бұрын
HF inverters use a transformer operating at 50 hz ,and requires a large iron core transformer . HF inverters are the same and operate at 30000 hz and requires a ferite core transformer but much smaller due to the operating frequency . both types are ISOLATED
@McBee465 күн бұрын
He should first learn to understand the status data being presented by the charge controller or the hybrid inverter in relation to the load to be able to manage his solar system.
@Electronzap5 күн бұрын
Sounds good. I have assorted batteries, so I decided to have separate charge controlers and have each battery limit the total power it can provide to the inverter/DC to DC converter. Will probably get hybrid inverters that you can attach to other hybrid inverters.
@oluwoleodetola16265 күн бұрын
Mr Ikenna should please Google "Edafe Imogu search FM" watch the guy's tribute (he is late).......You sound exactly like him 😂
@andyjesuorobo37015 күн бұрын
You are the best 👍 .
@smilinsunsmilinsun80565 күн бұрын
@@andyjesuorobo3701 Still learning actually
@awakenedblackheterosexual56096 күн бұрын
I live in N. Florida is it worth being grid tied or just paying your utility bills?
@Staenli_6 күн бұрын
First of all employ the services of an engineer he/she should individually check the battery voltage to ensure all are at the same voltage, one, two or more batteries in that setup might be lower in voltage than the rest, let's assume its a 48volts system 12v x 4 batteries = 48v, if for example if one battery is at 10.5v eg: 12+12+10.5+12 =46.5v, you can see it directly affects all the other batteries even if they are brand new and since they are connected in series it can never balance itself out. Secondly these are lead acid batteries, whether tubular or not you're never meant to discharge it below 50% of it's rated capacity, from the video you badly discharged it till it's sitting at 41.6v ÷ 4 = 10.4 per battery, that is a completely dead battery, my guess is that you have been doing that continuously for a very long time & there's a high chance that some of those batteries have sulphated which automatically results in very low performance no matter how well you charge it. One can easily observe from the video that you don't take care of the system at all. Thirdly buy two 2x4 or a 4x2 battery rack & tidy up your installation area it looks awful & a potential fire hazard waiting to happen, & let's not forget those tubular batteries sometimes leaks electrolytes acid which can most times corrode you floor. There are so many other things that i would also like to address like your panel setup how many watts (probably a lower watt panel) & how it's wired, my guess is maybe the initial setup was for 48v system with 4pcs of batteries only maybe along the line you personally decided to buy 4 more batteries to join making it 8pcs as we can see from the video, without considering whether the panels can charge it or not (assuming it's a lower watt panel).. Just employ the service of a professional so they can troubleshoot the system & correct any problems they find.
@oluwoleodetola16266 күн бұрын
50% dod is the issue with led acid battery 😢
@bethelchiboy366 күн бұрын
The guy wasn't even using DC cables lol. Ignorance indeed
@nwankwocollins29586 күн бұрын
This man probably hired a quack to do this installation by mere looking at the arrangement of the batteries. Even the cheapest change over isn't even original. Who knows how the panels are connected.?
@smilinsunsmilinsun80564 күн бұрын
@@nwankwocollins2958 Yes it is
@smilinsunsmilinsun80564 күн бұрын
@@nwankwocollins2958 Yeah
@judeezetteubezue52906 күн бұрын
That looks like a 100amp knife switch, who knows the capacity of the inverter used, those wires on the battery are small for 38amps 12 v battery, not to talk of 220amp 12v batteries
@smilinsunsmilinsun80566 күн бұрын
@@judeezetteubezue5290 Thought so too
@realToby6 күн бұрын
You hit the nail on the head. I also don't see any safety devices like SPD, DC breaker/fuses in the video.
@smilinsunsmilinsun80566 күн бұрын
That is a fantastic Observation my friend
@mikizhero6 күн бұрын
Which DC fuse do you recommend please.
@tamidis55007 күн бұрын
Drink whenever you hear "alright".
@WHAT-DOES-THE-BIBLE-SAY7 күн бұрын
No special information. I was hoping there is a device I can add to my charge controller to boost the little current coming from the solar panels during raining season.. It still boils down to having more panels.
@wizlipskings89587 күн бұрын
Where is and where do we use gel batteries. School or shops??
@smilinsunsmilinsun80567 күн бұрын
@@wizlipskings8958 Not clear
@wizlipskings89587 күн бұрын
@@smilinsunsmilinsun8056 u said tubular is good for places with high energy surge , or when one wants to use things with high capacity like pumping of water , so am asking where is recommended to use gel batteries..? What kind of project are gel batteries good for ?
@EasyyokeFilms7 күн бұрын
The lower your budget, the lower you should learn to keep your load. I am running 24hours, no downtime on a meager 3kwhr battery. I don’t have any downtime even in the raining season. All I did was learn to drastically reduce my load. I swapped out all my regular fans for DC fans. My previous fans were 150w. My current DC fans consumes 28w at the highest(that is about x5 reduction). I switch off my 49inches TV that consumes about 110W, I use my 27inch Monitor that consumes less than 25W. I switch off unnecessary bulbs. Reduce my load drasticalllllllly. I added a standalone LIFEPO4 AC charger that can accept “dirty power” from generator(if worse comes to worse. My battery is fully charged in 3hours with generator and that carries me for the next 24hours again). The generator only works on rainy day. I have not put on the generator in about two weeks now. Get proper information. Any amount of battery will be enough if you know how to reduce your load and you have the right information. Shikena
@smilinsunsmilinsun80567 күн бұрын
@@EasyyokeFilms Thank you so much for sharing this is very informative.
@danielekweo.97707 күн бұрын
Thanks Sir
@omotolaoyeniyi6318 күн бұрын
The large transformer boosts the 24v AC the board supplies to 240v AC. The transformer doesn't convert, it transforms. The LF uses mosfets and Co to first convert DC to low voltage high ampereage AC while the Transformer transform the voltage into a higher voltage and lower amps. As for high frequency inverter, it's way more efficient, it's better to overspec on HF inverter, I normally do that and I have had a lot of success with them