Is there any video on how to connect this to PLC Box or Experion sofware?
@jianliang-of8sf5 ай бұрын
How to buy BEST Expert Support Tool Pro License??
@johnpapa8510 ай бұрын
How is it possible to do the same but with ADAM 4000 modules instead of NI DAQ device? (OS: Win 11 and labVIEW 21)
@daelimefive Жыл бұрын
I got a problem to connect a Brooks SLA 5800. The device is powered by the original brooks RS 485 adapter. However I cannot connect the device via the 2.5 mm jack to Rs 232 Adapter. The device cannot be found, even though the USB-RS232 Adapter is shown in the device manager. Which RS232 to USB Adapter is used in the video? I am using a Digitus with a Prolific PL2303 GT chip inside.
@hariprasadh45372 жыл бұрын
Can this be used for SiCl4 gas?
@Brooks4072 жыл бұрын
Yes it can. Here are some of the other critical low-pressure gasses supported: experience.brooksinstrument.com/pressure-based-mass-flow-controller-gp200/segment-b-63FQ-567T2.html
@phamvanvinh13102 жыл бұрын
Please tell me what unit marking on the tube? is it scc/min?
@beungkeunlee3 жыл бұрын
Look good
@robd43613 жыл бұрын
Ok, I will do that. Thanks for your reply!
@robdoyon12033 жыл бұрын
Hi Peter and Mohamed. Can you please tell me how to re-zero my Brooks 150 slpm CO2 MFC? It has a zero pushbutton, but, pressing this button doesn't change the output of the meter. I always have an offset of 1.5 liters. Is there some special sequence to use the pushbutton? Nice video, by the way! Thanks, Rob
@msaleem19653 жыл бұрын
Hi Rob, thank you! Yes, there is a specific sequence to zero the MFC. Please reach out to Applications/Service Department of Brooks Instrument and/or consult the operations manual for the MFC. Since your MFC is 18 years old, I suspect there are going to be limitations on zeroing as electronics age with time.
@abdulbalobaid63613 жыл бұрын
Where is the next video? 😁
@tcaltotalweighingandmeasur77754 жыл бұрын
Please let me know if this MT3809G communicate with EMERSON AMS TREX Communicator device.
@ShenelleDhoray4 жыл бұрын
What is the voltage level required for LOI?
@Brooks4074 жыл бұрын
Hi Shenelle, Thank you for your interest in Brooks! If you don't mind, please email your question to [email protected] and one of our experts will get back to you. Thank you!
@sudheerkumarnakka99076 жыл бұрын
I want to implement a processor software in Labview, when i run that processor software in the system, which will control the MKS (Mass Flow Controller device) , and each and everytime I want to change the velocity in that software when i run it, then i have t to check the response of cross sensitivity of the sensor which is connected to the MKS device. could you please suggest meif anybody has any idea how to implement the software. thanks in advance
@kamrulome9026 Жыл бұрын
Hi Sudheer! Have you been able to figure this out?
@EnriqueGarcia257 жыл бұрын
The only problem I had with this video is the sound. His voice kept fading in and out.