Low pressure fault on a baxi combi boiler Do not attempt to work on a gas appliance unless competent or qualified to do so
Пікірлер: 26
@macpatel78105 ай бұрын
Love the 60 second fault finding clips. No faffing about. Concise and to the point. Great to see you back again PB. Hope you're well.
@mcfly101465 ай бұрын
If you put the boiler name in the title, it might attract more searches, love your work PB
@user-li8gr8ur8l5 ай бұрын
Brilliant clip mate signs of engineering at its best
@pasgas12safe585 ай бұрын
Great quick tip Pete, glad to see you back brother!!👍
@Adam-tn7yk5 ай бұрын
Love it. I've gained so much watching pb and the other gas vloggers. Thanks
@cianpapazian5 ай бұрын
Thanks Pete. I’m fresh into gas so these videos help me out massively
@cerealkiller42485 ай бұрын
Can I add a little tip for everyone out there. I carry a few pieces of cable with crimps on each end, one with 2 male spade connectors, one with 2 female spade connectors and one with a male spade connector one end, and a female spade connector on the other. This has allowed me to get a 💯 secure connection when I’m by-passing switches to prove faults. Please remember to remove them though guys, you’re not helping the customer by leaving them in whilst you order a replacement. Years ago I got called to a nursing home. An electrician had gone there on a call out in the middle of the night 2 days before. He’d by-passed the surge protection and hadn’t gone back. They had a power surge and blew it blew everything. Everything with a PCB including the residents video recorders ( yes it was over 20 years ago 😂😂😂 ) got fried. I was there to order new boiler PCB’s. The engineer got slated for it, but I guarantee all he was trying to do was keep the heating on for those residents who feel the cold badly. He probably had more call outs and meant to go back, he just never got the time. For caring his name was dirt.
@mrseb995 ай бұрын
Fantastic tip, great to see you back 👍🏾
@sken12325 ай бұрын
Thanks Pete you legend!!
@mrnsp50135 ай бұрын
Good to have you back Pb
@b1h2u3p45 ай бұрын
Loving the content 👌 more videos please. You are helping out alot of people.
@discobiscuits55645 ай бұрын
Good to see ur bk PB hope ur well dude
@daljitsingh5495 ай бұрын
Brilliant as usual 👏 👌
@jewelahmed61975 ай бұрын
Thank for the tips mate
@Smart_fix5 ай бұрын
Brilliant 👌👍🏼🙂
@ahmedahmed-rn8gb5 ай бұрын
Great stuff
@ununha5 ай бұрын
Love this
@ian11045 ай бұрын
Lovely easy peasy ❤
@salam2385 ай бұрын
Can you bypass hot water thermistor?
@russellthomas93915 ай бұрын
That boiler throws up a fault code for a faulty water thermistor but to answer your question- by passing it won’t work as it’s a resistor and not a switch like the water pressure sensor
@PBPlumber5 ай бұрын
No you can’t bypass a thermistor as it’s looking for a resistance value not a closed or open circuit
@twistandturn025 ай бұрын
Generally, a thermistor is usually around 11,00 ohms at room temp. You can test this with the ohms setting on your multimeter. If you have a spare, you can do the same as PB here and plug it in (not installed) to test without having to drain or isolate anything to see if the boiler fires. It'll probably immediately throw up a different fault because there's no temp increase but it's a quick and dirty way to prove the NTC is the issue.
@daz37455 ай бұрын
Crap in the sensor I'm guessing
@PBPlumber5 ай бұрын
Normally is when they are installed horizontally
@pasgas12safe585 ай бұрын
@@PBPlumber very interesting point👍
@twistandturn025 ай бұрын
@@PBPlumberlike every Vaillant for as long as I can remember, and that's back in the day of the salmon pink ones.