Basic Programming on a Simplex 4010 Panel

  Рет қаралды 55,495

Fire Alarms and Such

Fire Alarms and Such

Күн бұрын

Do not tamper with safety equipment, I am not responsible for your actions.
Thanks for watching and your continued support! Don't forget to subscribe!
Check out my eBay account, where I sell some of my devices featured in my videos! www.ebay.com/s...
Have questions or want to submit your own Wall test idea? firealarmsandsuch@gmail.com
Do not copy or redistribute any video or channel content without express permission from channel owner.
All tests were done in a controlled environment. No actual alarms were initiated unless otherwise stated. All permissions were granted for creation of these videos. These are created for demonstration/education purposes.

Пікірлер: 65
@nursejoy6698
@nursejoy6698 3 жыл бұрын
No one at my building Knew how to disable the trouble after going into program mode. Thanks to your video, I fixed it and look like a genius. Thank you
@ZakWolf
@ZakWolf 4 жыл бұрын
My first elementary school has a Simplex 4010 system. It was installed around the mid-2000s, tied into the school's original Simplex 4208 panel from 1974 (the 4010 was replacing a 4004 installed in 1998, which in turn replaced a Simplex 4002 installed in the late 80s or early 90s for added-on duct detectors.) The 4010 was for main controls, the duct detectors, signal coding and the modular building, while the 4208 was used for the existing pull stations, heat sensors and an old ionization smoke detector. They had Simplex 4051+4050-80 horn/lights, but they used 120-VAC light plates for some reason, and while the NACs on the 4010 would code the signals (Slow March Time), they had to run through the 4208 to provide the AC power for the lights (while the horns were 24-VDC.) But in early 2015, the Simplex 4208 panel started failing (sometimes the signal circuits wouldn't work in a certain zone, or the system would randomly go into alarm), so during the February break they gutted the 4208, wired everything into the 4010, replaced the old 4208 battery cabinet with a couple of EST booster power panels, and replaced all alarm signals with boring SpectrAlert Advance horn/strobes (they even replaced the Wheelock MT-24-LSMs in the modular with Advances!) But at least my city's school district considers faulty/malfunctioning fire alarm systems a top priority on their agendas!
@enamakram1579
@enamakram1579 5 жыл бұрын
And this video was really very very helpful for me. Thank you boss
@nebarodrick977
@nebarodrick977 3 жыл бұрын
This is a wonderful lesson. Thank you!
@senioralarms4068
@senioralarms4068 4 жыл бұрын
Amazing video man
@ncnyxx13
@ncnyxx13 5 жыл бұрын
24vdc will not hurt you...
@thenextgen1able
@thenextgen1able 2 ай бұрын
You could touch both battery terminals with your hand and nothing would happen. 24V isn't enough voltage to break/arc through your skin.
@mohamedsadokboudhraa7964
@mohamedsadokboudhraa7964 2 жыл бұрын
Thank you
@cmace7703
@cmace7703 5 жыл бұрын
Nice video! Can you do a video of just how to wire one of these? I think that would be really cool since there really isnt a video in that on KZfaq
@FireAlarmsandSuch
@FireAlarmsandSuch 5 жыл бұрын
Sure Thing!
@johnjennykalesdaviduk93
@johnjennykalesdaviduk93 4 жыл бұрын
ther is a wire vieo from ser safet
@ryanmanagili5122
@ryanmanagili5122 7 ай бұрын
Good Day sir, I have a question. What is the password to level 4? Please answer i really need to know. Thank You in advance sir. Im from philippines.
@joelschuler1745
@joelschuler1745 3 жыл бұрын
I got one of these panels, but my level 4 code 4000 won't work. Any ideas how to default the panel and restoring the default level 4 code?
@nitrixdev
@nitrixdev 3 жыл бұрын
Try 4444 maybe?
@chrishoffman6537
@chrishoffman6537 2 жыл бұрын
What level is required to make the dialer dial a 10 digit number instead of the 7 digit number it was programmed with
@ulisesocampo632
@ulisesocampo632 6 жыл бұрын
Does anybody knows how to get the account number for the phone lines from this simplex 4010?
@jaredmauriello9522
@jaredmauriello9522 3 жыл бұрын
This is only accessible through the 4010 PC programmer. The PC Programmer requires a security key from Simplex which you only have when you complete the training class.
@naumannizamkhan8902
@naumannizamkhan8902 3 жыл бұрын
Kindly make videos for programing on 4020 control panel simplex....
@chinoak4749
@chinoak4749 Жыл бұрын
Need help deprogramming a smoke detector above the duct system.
@DCC--vq1ng
@DCC--vq1ng 4 жыл бұрын
Hi,I would like to know that would a spectr alert advance connected to simplex panel fry because of different types of current output(FWR or filtered DC)?
@keerthi47kv
@keerthi47kv 3 жыл бұрын
The AC power lamp is turning on and off continuously the system is booting continuously
@frankspliff7037
@frankspliff7037 3 жыл бұрын
Just a question how hard is it to program a audible bypass on the right buttons?
@randomperson36596
@randomperson36596 6 жыл бұрын
Cool!!!
@bhh54
@bhh54 3 жыл бұрын
We are preparing to demo a suite at our business that has 13 smoke detectors, 7 strobes and 2 pull stations. What are your recommendations for disabling the points and listed on our print out of the points list names for these devices.? Post disabling the points, you mentioned the wires are still live. What should we do with the devices during the construction ?
@coastlinecruiser8429
@coastlinecruiser8429 3 жыл бұрын
As a former tech I would recommend taping off the smoke and heat detectors with tape so to not allow dust and debree to enter the "detecting chambers" and just let them hang by their wires out of the way, same with pulls and strobes, just make sure to write with a sharpie on the masking tape on the devices that they are "live". This way you can continue to demo out where needed with a system still online (connected to the monitoring center) until you can get a tech onsite to either relocate the devices, re install after a remodel, or remove them from the system itself (remove from programming and them physically remove the devices) if you are completely doing a full gut down to the studs and need to rip the system out so a fresh one can be installed after the construction is completed, you want to call your monitoring company and cancel the service for that control panel/system that you need removed so that no "trouble calls" come in to the monitoring center due to the phone lines on the panel becoming disconnected and the monitoring center no longer having contact with a system that does not exist anymore.
@baguiomark2294
@baguiomark2294 5 жыл бұрын
How to fix idnet card 3
@caleb0606
@caleb0606 6 жыл бұрын
Thank you so much. Can you add a annunciator to this panel.
@FireAlarmsandSuch
@FireAlarmsandSuch 6 жыл бұрын
I'm trying, but they are kind of pricey.....
@nicodo123
@nicodo123 6 жыл бұрын
Why no access level 2?
@FireAlarmsandSuch
@FireAlarmsandSuch 6 жыл бұрын
Level two is basically the same as level three
@lorirodriguez2388
@lorirodriguez2388 3 жыл бұрын
Sorry I had to lower it I am scared of fire alarms and fire drills
@coltonkowalczyk4028
@coltonkowalczyk4028 4 жыл бұрын
At 6:30 whats the name of that pull station
@FireAlarmsandSuch
@FireAlarmsandSuch 4 жыл бұрын
Mircom MS-501
@coltonkowalczyk4028
@coltonkowalczyk4028 4 жыл бұрын
@@FireAlarmsandSuch thank you
@vintagesimplexfirealarmsof6440
@vintagesimplexfirealarmsof6440 4 жыл бұрын
What about march time and other codings were do that i always wanted to know that i just carrious because i might buy a pannel for my own house and have mechanical horns on it
@FireAlarmsandSuch
@FireAlarmsandSuch 4 жыл бұрын
That is done under Programming> System Options> Audible NAC Operation
@vintagesimplexfirealarmsof6440
@vintagesimplexfirealarmsof6440 2 жыл бұрын
@@FireAlarmsandSuch what level is that
@carlh4279
@carlh4279 2 жыл бұрын
Control/view points. YES you can control points, yes you can disable points
@Fahrenheit4051
@Fahrenheit4051 4 жыл бұрын
5:30 - I guess you can't... recall?
@gaya-gayavlog4597
@gaya-gayavlog4597 4 жыл бұрын
How many nac circuit that kind of control panel?
@FireAlarmsandSuch
@FireAlarmsandSuch 4 жыл бұрын
Four programmable NACs
@enamakram1579
@enamakram1579 5 жыл бұрын
Boss can you make 1 more video for me how to do this same basic programing in simplex 4100
@FireAlarmsandSuch
@FireAlarmsandSuch 5 жыл бұрын
I don't own a 4100 or know how it works fully, sorry.
@djjammindave
@djjammindave 5 жыл бұрын
There is another video from somebody else here in KZfaq.
@saifrehman1649
@saifrehman1649 4 жыл бұрын
CARD 3= ID NET CARD CHANNEL FAILURE. HOW WE CAN REMOVE THIS FAULT.
@ibrahim1saleh166
@ibrahim1saleh166 Жыл бұрын
What's the password access 4 level& 3?
@ryanmanagili5122
@ryanmanagili5122 7 ай бұрын
Yes what is the password? Please tell to us. Thank you in advance brother.
@kevinl4482
@kevinl4482 5 ай бұрын
Level 3 is 3000. Level 4 is 4000 level 2 is 2000
@probashibangladeshi5005
@probashibangladeshi5005 4 жыл бұрын
this addressable or conventional?
@saravanamoorthy6892
@saravanamoorthy6892 4 жыл бұрын
Addressable
@saravanamoorthy6892
@saravanamoorthy6892 4 жыл бұрын
What is default password of simplex 4010... I want to change the date and time
@FireAlarmsandSuch
@FireAlarmsandSuch 4 жыл бұрын
I cannot disclose passwords, sorry
@saravanamoorthy6892
@saravanamoorthy6892 4 жыл бұрын
@@FireAlarmsandSuch thanks for ur reply
@saravanamoorthy6892
@saravanamoorthy6892 4 жыл бұрын
@@FireAlarmsandSuch thanks for ur reply
@safetyzone2962
@safetyzone2962 3 жыл бұрын
Check the manual, they have the passwords for level 2-4
@Nobody2day553
@Nobody2day553 3 жыл бұрын
Judging by the audible tones and knowing it's a 4 digit passcode... it seems he changed the first digit 3 times and then skipped 3 times... so I'd say the level 3 passcode is 3000.
@bijinvj3465
@bijinvj3465 4 жыл бұрын
What is the password??
@DCC--vq1ng
@DCC--vq1ng 4 жыл бұрын
@@kittycat726 333 or 3000
@SuperTaufiq123
@SuperTaufiq123 5 жыл бұрын
How can I get the password?
@FireAlarmsandSuch
@FireAlarmsandSuch 5 жыл бұрын
That is something I cannot give out, you would have to find a Simplex tech
@djjammindave
@djjammindave 5 жыл бұрын
333, 3333, 3000
@mytruenorth5593
@mytruenorth5593 5 жыл бұрын
@@djjammindave you da real MVP.
@akramenam975
@akramenam975 3 жыл бұрын
Very boring
Adding an IDNet Point to a Simplex 4010 Fire Alarm Control Panel
8:18
Fire Alarms and Such
Рет қаралды 7 М.
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 165 МЛН
Алексей Щербаков разнес ВДВшников
00:47
SPILLED CHOCKY MILK PRANK ON BROTHER 😂 #shorts
00:12
Savage Vlogs
Рет қаралды 49 МЛН
UNO!
00:18
БРУНО
Рет қаралды 5 МЛН
Advanced Programming and Operation of the Simplex 4010!
16:28
Ryan Woods
Рет қаралды 1,9 М.
Simplex Fire Alarm Panel Linking Demonstration
11:42
dewpoint8900
Рет қаралды 535
Notifier NFS2 640 Programming Guide
28:30
Roxxofoxxo
Рет қаралды 27 М.
Simplex 4010 Test 32: I'm Back!
14:51
Fire Alarms and Such
Рет қаралды 7 М.
How to wire up the Simplex 4010 addressable fire alarm control panel.
22:52
How To Program A Device In On The Notifier NFS2-3030
6:41
FireTech
Рет қаралды 42 М.
Disable Point 4100U
6:32
FireAlarm Tech
Рет қаралды 28 М.
What is a Fire Alarm System?
11:06
RealPars
Рет қаралды 2,1 МЛН
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 165 МЛН