Baxi 105e Filling loop removal and replace

  Рет қаралды 27,257

Rahgsa 0509

Rahgsa 0509

7 жыл бұрын

How to remove and replace a filling loop for a Baxi combi boiler 105e.

Пікірлер: 30
@Sugi1971
@Sugi1971 Жыл бұрын
I bought a Potterton Refilling Loop today to replace the leaking refilling loop on Potterton Powermax Heat Engine Condensing Boiler 85 litre. It has been leaking for years and I finally decided to do something about since I am tired of my boiler pressure falling. It is now back to normal at 1.5 pressure gauge as it should be. Thank you very much for sharing this video it was very helpful. I also used my hair dryer to quickly dry the areas where water spilled.
@user-do-it-yourself-help
@user-do-it-yourself-help Жыл бұрын
Great to know that the video was helpful. Thanks for the comment :)
@mob271
@mob271 6 жыл бұрын
Nice video mate very useful indeed.
@user-do-it-yourself-help
@user-do-it-yourself-help 6 жыл бұрын
Thanks for comment, hope it helped.
@Unterred
@Unterred 6 жыл бұрын
Thanks so much for this video, top job, this really helped me! 😄
@user-do-it-yourself-help
@user-do-it-yourself-help 6 жыл бұрын
Here to help, thanks for the comment.
@Listermintsluesh
@Listermintsluesh 4 жыл бұрын
Great video. My filler loops leaking and, the flathead screw valve has worn too so hard to get screwdriver in. So, turn off water from mains and make sure pressure gage is zero bar on boiler, turn off electrical connection. That's it I think. Update......did it. Thanks for instructions !!!!
@user-do-it-yourself-help
@user-do-it-yourself-help 4 жыл бұрын
Great job, Great the video helped you out and thanks for the comment.
@StuWright
@StuWright Жыл бұрын
thanks, this helped
@user-do-it-yourself-help
@user-do-it-yourself-help Жыл бұрын
Glad it helped
@ratchriat1716
@ratchriat1716 5 жыл бұрын
ihave indirect systeme means hot water cilynder expenssion vessel do i have to drain the heating system only or the boiler enjoyed the video
@user-do-it-yourself-help
@user-do-it-yourself-help 5 жыл бұрын
The aim is to empty the boiler of all its water so you can work on it, if you have a water cylinder which supplies the boiler with water then you need to stop that water coming into the boiler, you may need to drain the whole cylinder by turning off the mains and opening a tap until empty, or you may have a isolation valve which will turn the water off to the boiler without the need to drain the entire cylinder.
@paulcroad5248
@paulcroad5248 4 жыл бұрын
Hi there I'm going to do this tomorrow, so all I need to do is turn off water supply and boiler mains then I can work on it
@user-do-it-yourself-help
@user-do-it-yourself-help 4 жыл бұрын
Turn mains water off, switch boiler off then drain boiler of all the water and your good to go.
@alizcool1
@alizcool1 4 жыл бұрын
@@user-do-it-yourself-help that might be handy detail to mention in the video lol
@vim1471
@vim1471 4 жыл бұрын
I only need to change the valve on the water side as its letting by. Would i just turn off the mains water for that and not drain the boiler ?
@user-do-it-yourself-help
@user-do-it-yourself-help 4 жыл бұрын
Drain the boiler.
@johnmarsey3312
@johnmarsey3312 6 жыл бұрын
Do u need to drain the central heating side if you take the check valve off ?
@user-do-it-yourself-help
@user-do-it-yourself-help 6 жыл бұрын
just drain the boiler.
@stuffoflardohfortheloveof
@stuffoflardohfortheloveof 4 жыл бұрын
I’m confused. Two things....firstly you have surely drained down the system prior to this but haven’t shown it....why not? Secondly, why didn’t you turn off the valve on the upper section of the filling loop and remove the bottom connection first? If you did this then you could then put the flexible pipe into the bucket and then turn the upper valve back on, releasing any remaining water straight into the bucket, instead of having it running everywhere and having to mop up? I don’t get it.
@user-do-it-yourself-help
@user-do-it-yourself-help 4 жыл бұрын
Good point. The reason I don't as you suggest is I went to a job once and I turned of the upper section of the loop and opened the bottom valve, what you think happened, well I got very wet. Reason being was that the upper valve to the filler loop was ceased open and the turning valve handle turned into the off position without any issues, not knowing that the handle mechanism was warn out and the valve was open. I got all wet and everything around me, resulting in a lot of cleaning and drying up. let me tell you its easy to turn the handle to close the valve on the top section of the loop but try closing the valve with a flat head screw driver after water is gushing out at pressure on the bottom end of the loop when you least expect it. "Panic Stations" lol. For this reason I never did it that way ever again just to be on the safe side. I know it saves time as you suggest but hope you understand why I do It this way. Thanks for you comment.
@minto7699
@minto7699 2 жыл бұрын
What does the vertical silver valve do ?....I don't see a handle.
@user-do-it-yourself-help
@user-do-it-yourself-help Жыл бұрын
This is an isolation valve which allows water from the mains to fill the boiler with water which needs to be closed after system is full.
@waynethompson3886
@waynethompson3886 6 жыл бұрын
You switched off the water from the stopcock and drained the water through the kitchen taps before you started. And then you switched off the boiler from the mains before you start this job, is this correct? Do I have to do anything else before I replace the filler loop hose?
@secretasassin6147
@secretasassin6147 6 жыл бұрын
Wayne Thompson exactly what I was thinking!!!
@user-do-it-yourself-help
@user-do-it-yourself-help 6 жыл бұрын
Nothing else.
@amoomaamooma
@amoomaamooma 6 жыл бұрын
Hi, I have a combi boiler, do I have to drain the boiler/system to change a filling loop or can I just turn the water and boiler off at the mains? Thanks
@user-do-it-yourself-help
@user-do-it-yourself-help 6 жыл бұрын
Drain the boiler / system. Its the loop that allows the water into the boiler. The loop is connected to your main water supply.
@randhirbundhoo4252
@randhirbundhoo4252 5 жыл бұрын
I'm need to change the filing loop im need to close first what.
@user-do-it-yourself-help
@user-do-it-yourself-help 5 жыл бұрын
Yes, shut off the water coming into the boiler and drain the boiler of all the water.
Potterton combi boiler He 28 loop pipe replace
8:01
Mark Davies
Рет қаралды 13 М.
Baxi Connected self-help: how to repressurise your boiler
5:33
Baxi - sustainable heating and hot water solutions
Рет қаралды 177 М.
Slow motion boy #shorts by Tsuriki Show
00:14
Tsuriki Show
Рет қаралды 9 МЛН
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 3,5 МЛН
All you need to know about filling loops
2:15
Altecnic Limited
Рет қаралды 3,2 М.
potterton promax 28he water pump removal
5:14
Mark Davies
Рет қаралды 16 М.
How to: Filling loop replacement
3:47
Snapgas
Рет қаралды 10 М.
Why Your Boiler is Losing Pressure and How to Fix It
12:25
Proper DIY
Рет қаралды 122 М.
Why Does My Boiler Keep Losing Pressure?
36:37
Skill Builder
Рет қаралды 393 М.
How to connect a filling loop to a combi boiler
6:12
dereton33
Рет қаралды 93 М.
Baxi 105e draining the water from the boiler
3:23
Rahgsa 0509
Рет қаралды 38 М.
Головоломка от дедушки🔥
0:31
FERMACHI
Рет қаралды 18 МЛН
Что делать если забыл ОЧКИ??? #моястихия #swimming #юмор #fun
0:23
МОЯ СТИХИЯ | ПЛАВАНИЕ | МОСКВА
Рет қаралды 3,9 МЛН
Forming of goal foam || A2Z SKLLS
1:00
A2Z SKILLS
Рет қаралды 24 МЛН
Fast and Furious: New Zealand 🚗
0:29
How Ridiculous
Рет қаралды 42 МЛН
Сделала Сюрприз Брату После 3 лет Разлуки ❤️
0:26
Глеб Рандалайнен
Рет қаралды 1,9 МЛН