CGAM 110 Chiller EXV Comm Loss And Not Cooling | Multiple Issues

  Рет қаралды 4,373

Subcool HVAC

Subcool HVAC

Күн бұрын

Got a work order for CGAM EXV comm loss plus other faults, this one is a Gem. Ugly #hvac #trane #chiller

Пікірлер: 22
@ColeTrain44
@ColeTrain44 10 ай бұрын
Just replaced condenser coils on a RTAA a few months back. Fins were smashed flat from maintenance guys blasting them with the water hose. misters were in full force 😂 that’s when you know it’s bad. Nice video
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
Nice, Thanks for sharing
@topher8634
@topher8634 7 ай бұрын
Maintenance force where I worked is comprised of different crews. I stopped one from using an electric pressure washer on a row of condensers. Then I gave them a comb to straighten their mess out.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 10 ай бұрын
Yeah...the misters are not a favorite of mine either. I've had more issues with Trane harness's than anyone else. Those CGAM's love to eat sensors, eev's and condenser coils. Had some compressor issues, but not as many as other things. I've worked on quite a few of those in my day. Nicely done getting her back up and running.
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
At 10 years these condensers around here are fouled beyond 20% for sure, this one is 13yrs. I’m sure the extra water isn’t helping the harnesses and sensors here. Unfortunately it’s a waiting game on replacement. Thanks for the comment Jason !
@thejnelson88
@thejnelson88 10 ай бұрын
Is that a water mister or a drencher Lol. On the ammonia side we had a company trying to put thermorphin air-cooled condensers in Texas, customer constantly had head pressure issues the "solution" was to put in a custom water "misting" system. The water treatment system failed in the first year. Ended up drenching the coils and the screw compressors. Same issue was eating sensors, motors and everything. Fins covered in calcium build up. Its still a thorn in my side during the change over to standard Frick packages and an EC condenser.
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
Coil soakers more like it, they should have installed gutters while they were going through the effort. I agree, these sensors and cables don’t need help shorting out . Thanks for the comment 👍
@Chillerguy48
@Chillerguy48 5 ай бұрын
I've got some customers that do this also. They are shooting themselves in the foot trying to keep it running. I always recommend water cooled equipment. More expensive and more to keep clean but you can run in the summer.
@subcoolHVAC
@subcoolHVAC 5 ай бұрын
Our smaller sites are mostly air cooled, have water cooled on larger ones. Thanks for the comment 👍
@zekenzy6486
@zekenzy6486 4 ай бұрын
Great Video. Thank you for sharing
@georgebrabec1749
@georgebrabec1749 10 ай бұрын
I guess your customer doesn't believe in annuals or at least quarterly inspections !
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
They do, but these chillers were already supposed to be replaced. That $ part is out of my control . Thanks for watching
@inothome
@inothome 10 ай бұрын
I'm a little confused on the first megger test you did. Did you check winding to winding first? I see the second test was to ground and definitely shorted to ground. But on a three wire motor you can't test winding to winding insulation resistance, since they are wired together internally anyway. And checking coil resistance with the meter set to insulation test doesn't read low enough to measure coil resistance. So what am I missing? But that unit is on borrowed time anyway, not just one step closer.
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
Good catch, I was going back and forth with the ground test, one bad test to ground for sure .,Thanks for watching through 👍
@inothome
@inothome 10 ай бұрын
@@subcoolHVAC Got ya. Thanks for the videos!
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
My pleasure
@ccthepope
@ccthepope 10 ай бұрын
It is surely a mess!
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
Definitely is 👍
@MrJujubean
@MrJujubean 10 ай бұрын
She living on borrowed time
@subcoolHVAC
@subcoolHVAC 10 ай бұрын
Livin on a bunch of Prayers 🤣
@user-dg7ek6zu5k
@user-dg7ek6zu5k 9 ай бұрын
Too not clear
@subcoolHVAC
@subcoolHVAC 9 ай бұрын
👍
Trane Chiller Controller Bad Then Chilled Water Pumps
38:54
HVACTIME
Рет қаралды 26 М.
Troubleshooting A Call Back For Air Handler Down
12:16
Subcool HVAC
Рет қаралды 2,8 М.
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 165 МЛН
Yum 😋 cotton candy 🍭
00:18
Nadir Show
Рет қаралды 7 МЛН
Please Help Barry Choose His Real Son
00:23
Garri Creative
Рет қаралды 23 МЛН
Waterchiller - Trane RTHD B2
1:01
HOS BV
Рет қаралды 11 М.
Trane RTAC Leak Repair + Oil Filter Part 1
19:57
DFW HVAC
Рет қаралды 12 М.
TRANE VOYAGER NOT COOLING
23:21
HVACR VIDEOS
Рет қаралды 119 М.
TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?
10:29
leckyjake
Рет қаралды 185 М.
Startup Issues with Trane Chiller
7:23
HVACTIME
Рет қаралды 7 М.
Troubleshooting a chiller issue today
20:39
Curious HVAC Guy
Рет қаралды 24 М.
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 165 МЛН