COMMERCIAL 3 BASIN RESTAURANT SINK REPLUMB

  Рет қаралды 68,608

PLUMBING WITH TIM

PLUMBING WITH TIM

Күн бұрын

Join me today as we tackle a 3 basin sink in our local sub shop!

Пікірлер: 52
@GonzalesMansion
@GonzalesMansion Жыл бұрын
The clean outs were a great idea. Looks awesome
@shovelhead8
@shovelhead8 3 жыл бұрын
Nice job, Tim. Nice bonus as well. Thank you for letting us watch. Stay safe and stay cool.
@karlzaker6710
@karlzaker6710 10 ай бұрын
Hahaha. TIM; by code, you can’t put drain INTO floor drain. Air gap must be maintained to prevent contamination from flooding drain
@seanmalone7920
@seanmalone7920 Ай бұрын
100% right this isn't done correctly
@recoverygaming4900
@recoverygaming4900 3 жыл бұрын
This is like an everyday job very kool video to show people new to commercial plumbing
@SunnyKumar-hj4iy
@SunnyKumar-hj4iy 2 жыл бұрын
Thanks TIM...awesome vudeo.Great work.So helpful.God bless you man
@yepdodamath
@yepdodamath 3 жыл бұрын
1:35 I was starting to feel for that guy's eyes. Always wear eye gear!
@plumbbuild6517
@plumbbuild6517 3 жыл бұрын
I hear you dude great job and I hope you enjoyed that Jersey Mike's sub and thanks for your videos have a good weekend Tim
@cylentsmoker
@cylentsmoker 10 ай бұрын
Dude awesome. Just got into the same kind of work recently and i enjoy the shit out of it. Your videos are helpful man thank you
@elnicadrums
@elnicadrums 3 жыл бұрын
Nice 👍👍👍👋💪 good job you guys kicked butt 👍👍
@TheHuntermarks
@TheHuntermarks Жыл бұрын
You are one precise PVC measuring fool to line up all 3 and get em all to go in like that! 😂😂
@jpvoodoo5522
@jpvoodoo5522 10 ай бұрын
Yes, how do you figure out the length of each pipe and fixture? Can you recommend a tutorial on that part?
@tomdale1313
@tomdale1313 3 жыл бұрын
three compartment sink...good job
@user-fs6wb5kf1l
@user-fs6wb5kf1l 11 ай бұрын
i would be worried about the gaskets that are pushed out. should have tightened from the top with special tool
@angelloco72
@angelloco72 5 ай бұрын
Nice work 👏
@theartofplumbing
@theartofplumbing 3 жыл бұрын
Nice job Tim
@matthewpowell4845
@matthewpowell4845 3 жыл бұрын
Tim they make a t and a insert / key for those drains. But you seem old school and use channelocks lol
@curt8120
@curt8120 2 жыл бұрын
In any state I Work the code changed you cannot connect the drains together if you have one of the sinks being a clean sink, its a cross connection that is illegal in any restaurant. and the air gap is 2-1/2 times the diameter of the discharge pipe.
@elektroman3187
@elektroman3187 Ай бұрын
5:03 Great job! Only question is how did the dishwasher pull out the grills and filters out of the drain after you placed it so far down into the pit? Did you have to go back and cut it out to let the drains out or are they split grills? Those guys have to pull out the grills and drain filters to clean them at least every few days. Did they just figure they should clean it while it's hanging off the drain pipes? Regardless of my questioning, your work is at least 10 times better than the set up we have at my jobsite...
@michelejann5732
@michelejann5732 Жыл бұрын
For your safety safety glasses a must ❤❤
@antonioantonio7540
@antonioantonio7540 Жыл бұрын
Did you use a smaller pvc to fit in the drain pipe?
@jpardo100855
@jpardo100855 3 жыл бұрын
I'm curious as to whether you used the correct cement for the transition from pvc to abs?
@rojohe
@rojohe 9 ай бұрын
That double sanitary tee fitting is not ABS, it's PVC Schedule 80 (which is also available in PVC Schedule 40.)
@wittelarry1
@wittelarry1 Жыл бұрын
It's always fun cutting those out
@SandwichesRule
@SandwichesRule Жыл бұрын
Tim, I want purchase the new drains for my shop, I see there are 3”& 3.5”, how would I know what to purchase? Is there a measurement that I can take on my existing think? Thank you.
@madcowusa4277
@madcowusa4277 Жыл бұрын
Just a novice interested in plumbing, I thought code doesn't allow sanitary tees on their back like the two outermost sinks? I'm guessing the sinks themselves act as a vent and the pipe into the drain grate is air gapped. Anyway, saw a triple sink setup today with one additional sink draining in from each side of it (5 sinks total) - all done with sanitees like this so I guess this the norm. And all 5 sinks were plumbed in 1.5" ABS which can't possibly be big enough.
@michelejann5732
@michelejann5732 Жыл бұрын
So the 1.5" ABS isn't enough what would be
@scopeside
@scopeside 6 ай бұрын
Hey boss can you help me with something. Is there any codes for these or where you need 3 individual drains 1 per bay and are you allowed to put sani’s on their back ?
@seannappi
@seannappi 3 жыл бұрын
Hey, out here in Cali 😀 we have to air gap indirect drains, do you not have same rules? Thanks for the great videos keep up the hard work!
@graysonsheridan1593
@graysonsheridan1593 2 жыл бұрын
That center downpipe drops right into an open Drain. It is just covered to keep stuff from getting in there.
@dbenterprise3oh2
@dbenterprise3oh2 Жыл бұрын
Yes but it should still be air gapped. Just did a Starbucks in Delaware. Air gap is code.
@paigewagner4857
@paigewagner4857 11 ай бұрын
100% Indirect waste always has to have a 1" air gap no matter where your at
@gabeking2996
@gabeking2996 6 ай бұрын
You are right it has to have a 2" air gap it's international plumbing cod so it's like that everywhere kinda seems more like a handyman and not a plumber !
@gyver471
@gyver471 Жыл бұрын
Can I reduce it down to 1 1/2 instead of 2”?
@bartman22x1
@bartman22x1 Жыл бұрын
We need to do a 3 basin corner sink
@humbleone4227
@humbleone4227 3 ай бұрын
Nice job Whats the average on a job like that thank you
@seanmalone7920
@seanmalone7920 Ай бұрын
It's supposed to be indirect waste which mean ur discharge line should have an air gap at the top plate not Recessed inside the Floor Drain
@Erickhardaway
@Erickhardaway 2 жыл бұрын
What inch pipe did you use on the drain?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 2 жыл бұрын
2”
@thomasrawlings2715
@thomasrawlings2715 Жыл бұрын
If the threads were no good in top of drain, why was it still holding. Forget your key
@__comic
@__comic 3 жыл бұрын
How much did you charge for that job in about to do the same
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 3 жыл бұрын
I think it was between $450 and $500
@vishyandypurandat6208
@vishyandypurandat6208 3 жыл бұрын
Rookie here asking a question. Does it need a vent or is it so close to an entry or drain it doesn't?
@recoverygaming4900
@recoverygaming4900 3 жыл бұрын
It has an air gap so no vent needed
@steventaing1544
@steventaing1544 6 ай бұрын
That is not code it has to drain individually and have to be 1 inch above the in ground drain to avoid cross contamination.
@grubbygringo
@grubbygringo 3 жыл бұрын
No air gap? That's a big no no.
@thomasrawlings2715
@thomasrawlings2715 Жыл бұрын
Air gap is in floor drain under grate
@fredpastuh7518
@fredpastuh7518 3 жыл бұрын
Tee ABS? Why?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 3 жыл бұрын
Only one I could find in our warehouse 😂
@fredpastuh7518
@fredpastuh7518 3 жыл бұрын
@@PLUMBINGWITHTIM need use trans glue?)
@kingokafor6215
@kingokafor6215 Жыл бұрын
I believe in ohio that requires a 4inch air gap
@evanschrisjr
@evanschrisjr 6 ай бұрын
This does not pass code
Commercial Drain Assemblies
9:21
AtsTV
Рет қаралды 68 М.
22 Useful Tips And Tricks That Work Extremely Well
18:05
Anna Home
Рет қаралды 72 М.
路飞太过分了,自己游泳。#海贼王#路飞
00:28
路飞与唐舞桐
Рет қаралды 38 МЛН
3-Compartment Sink
9:16
DuPage County Health Department
Рет қаралды 106 М.
Drain Pros Ep. 5 - Grease Trap at Grocery Store Deli
9:56
Drain Pros
Рет қаралды 182 М.
How To Properly Use Your 3 Bay Sink
5:30
Charlotte Products Ltd.
Рет қаралды 17 М.
Grease interceptor above ground installation
2:17
Champion Plumbing
Рет қаралды 66 М.
Helpful Invention | Smart DIY Idea | Useful Tools
12:16
Alva Welding
Рет қаралды 13 М.
Leaking Pipes. Commercial Sink Repair
2:46
Load Master
Рет қаралды 70 М.
Replacing a krowne  hand sink faucet
3:07
Lou cardoso
Рет қаралды 1,8 М.
P-Trap Installation: Drain Doesn't LINE UP with Bathroom Sink Pipe - 2022
5:21
The Building Expert
Рет қаралды 1,2 МЛН
HOW TO FIX LEAKING COMMERCIAL RESTAURANT FAUCET
10:00
PLUMBING WITH TIM
Рет қаралды 23 М.