Connecting OFF Grid - Anker SOLIX F3800

  Рет қаралды 10,144

N Bundy Electrical

N Bundy Electrical

Ай бұрын

Anker SOLIX F3800 achieve maximum power with minimal effort
It's time to revolutionize. Charging with Anker SOLIX F3800 Home Power system. Begin your Powerful journey at ankerfast.club/7IK7lc
#AnkerSOLIX #LIVEINPOWER #AnkerSOLIXF3800
Join this channel to get access to perks:
/ @nbundyelectrical
This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.

Пікірлер: 36
@mikeselectricstuff
@mikeselectricstuff 28 күн бұрын
Something to be aware of when switching an installation to backup - if you have a central heating boiler, you may need to link the neutral and earth on your backup supply, otherwise the flame failure detection won't work and it shuts the gas off. Probably wise to do anyway otherwise your RCDs won't be effective
@imark7777777
@imark7777777 21 күн бұрын
Didn't know that was a thing in the UK as well. In the US this varies between product manufacturer although a lot of the stuff that's certified for use on construction sites under OSHA requires the ground neutral bond. But then that Causes issues if it's used for a home back up type set up as the Bond is already done in the panel causing current to flow in the CPC grounding conductor. So it's kind of hit or miss whether a gasoline generator will have or not and then the wild world of battery systems I'm sure it's all over the place.
@Harrycowlton
@Harrycowlton 28 күн бұрын
Take a look at the victron multiplus 2. That can forward feed and reverse feed and is an automatic switchover. Easy brilliant system.
@Marks-Garage
@Marks-Garage 27 күн бұрын
I used cheap grid tie limiters for my home battery set up. I then upgraded to a victron multiplus 5000. Amazing bit of kit and although seems expensive compared to competitors it is so flexible and you can customise lots of settings. I use mine as a grid tie limiter to reduce my electric bills and it saves me at least £100 a month at the moment.
@TheStarzGamers
@TheStarzGamers 28 күн бұрын
Hey nick, you can buy a three phase to single phase linking kit which will allow you to still use any of the ways on the board rather than just L1
@JensenPGATourDriven
@JensenPGATourDriven 21 күн бұрын
Great, bit of kit Nick, But I really like the Milwaukee drill and bits you have , it would be cool to do a in-depth on the Milwaukee tools 🧰 you have ⚡️👊
@stefanrobles3485
@stefanrobles3485 27 күн бұрын
I love your work keep up the videos
@CompuWhizz
@CompuWhizz 28 күн бұрын
Hey you got it done!
@phillipgwynne6580
@phillipgwynne6580 28 күн бұрын
I’ve got a couple of Anker usb (A&C) to iPhone lightning cables and also a USB c charger and all of them are by far the best I’ve ever had, the cables I’ve had for over three years and show no signs of breaking, although when plugging lightning plug into iPhone is did struggle to work plugged in one way, so have it a clean with electrical contact cleaner and fine now. I wonder if you could use the smaller add on battery to ‘trickle’ charge the larger main battery especially if your using solar for this reason and you have typical British weather. I’d like to think this will be one of these products where you can forever be trying to think up new ways to make the best use out of it/them. And/or the product(s), become Smarter giving you more options or it automatically works out best usage for you. If energy prices continue rising, I can see this becoming more popular.
@darrenbullen2742
@darrenbullen2742 26 күн бұрын
Fuse box do actually make a change over main switch for a single phase board. Could make a neat install if you wanted to do in your house.
@imark7777777
@imark7777777 21 күн бұрын
Well with only 32 commenting so far I'm surprised nobody else has mentioned the solar input conundrum. 2:40 it sounds like you're going to come down from the solar panels through an inverter from DC to AC then convert back to DC in the anchor. This will have a major/Definitely efficiency loss. You'd be far better going down to an isolator and then going straight to the anchor as that incorporates a solar input with some sort of charge controller and monitoring. Otherwise you're converting twice with an efficiency loss each time.
@lonewolfgeoff
@lonewolfgeoff 28 күн бұрын
nice 😊 id like one of those but id prob never afford it! i think its awesome seeing this done, esp with an anker unit! watch folks asking nick to do this to their homes! 😂😂😂
@supersparks9466
@supersparks9466 28 күн бұрын
I would of put the l1.2 and 3 in a Henley block above the meter and kept all way’s usable
@AGRElectrics
@AGRElectrics 26 күн бұрын
Just put L1 in bottom of iso and use a 3 way buss bar
@anthonybragg
@anthonybragg 28 күн бұрын
I was going to post link out the phases but you beat me to it. You could in theory run your unit when you are there off-grid couldn't you? And if you are allowed to have solar on the roof charge the power bank up from that as well as power your unit when you are not there. I think that's right. Also, you are paying for 3 phase when you only need single.
@stewartrobinson3060
@stewartrobinson3060 28 күн бұрын
You need to disconnect the pme earth whilst on self generation. As any fault current can back feed the grid causing issues to any lines staff working on the system
@mattWallJsy
@mattWallJsy 27 күн бұрын
@corymac what do you think to this?
@Koopris
@Koopris 27 күн бұрын
You need to check if the Anker links N+E when there is no earth from the grid. If it doesn't then a TT system is of heehaw use, there will be no L->E potential.
@persona250
@persona250 28 күн бұрын
Hello Nick . A typical pv inverter or genset would never try find a return path through the supply network. Electricity tries to return to its source which is always the inverter or genset which will have a neutral earth link inside . The earth rod is to return current for anyone receiving a shock to the actual ground .
@protectiongeek
@protectiongeek 28 күн бұрын
Any alternative source of electrical energy such as an inverter with battery or genset is capable of applying lethal voltages to the supply network, hence the requirements for break-before-make changeover switches or similar. Part of the purpose of a measured earth electrode is to facilitate protection against electric shock but serves other purposes, principally the provision of a reference point for system voltages.
@persona250
@persona250 28 күн бұрын
Yes I understand. My comment is aimed at Nick saying if the supply earth is lost the generator would lose its earth path . Reference only required for 3phase generator …
@philiphughes4515
@philiphughes4515 28 күн бұрын
Be careful, some energy suppliers charge commercial 3 x kwh of the highest phase current which means if you run everything on L1 you’ll be triple charged for usage. Best way is to leave stuff over 3 phases then bridge L1.2.3 on the off grid side.
@protectiongeek
@protectiongeek 28 күн бұрын
No, they don’t. Well, not in the U.K. Supply contracts for commercial premises can vary but essentially are based on kVA demand (not kW, so poor power factor is penalised) and units consumed.
@herrtomas6729
@herrtomas6729 27 күн бұрын
You guys started talking about Jackery as small power units, then looked at Bluetti which you talked highly of... Strange that you're on Anker for this (Anker have always been good) and not used the Bluetti that you used to have??
@smithurst18
@smithurst18 28 күн бұрын
Just bridge L1 L2 L3
@therealdojj
@therealdojj 28 күн бұрын
But how far will it go if you put some wheels on it 🤔
@lonewolfgeoff
@lonewolfgeoff 28 күн бұрын
bout 3 foot when you dont put the handbreak on! 😂😂😂 (btw seriously tho, good question!)
@mikewilkinson7802
@mikewilkinson7802 28 күн бұрын
How long does it take to charge once flat!!
@Sparks0001
@Sparks0001 28 күн бұрын
100% Charging: 2.7H
@robintodd3901
@robintodd3901 28 күн бұрын
I don’t see the point in a separate earth. Surely that battery storage works a bit like a shaver point. Completely isolated for making any complete path to earth as in the spiked ground.
@persona250
@persona250 28 күн бұрын
Electricity is returning to its source not the ground . The earth rod is needed if you are stood on the ground and touch the live wire it will return to the source and disconnect the rcd .
@robintodd3901
@robintodd3901 28 күн бұрын
@@persona250 on the battery pack I’d say you could touch live and the actual ground you stand and be fine all day long as the battery pack is separated and has no path via the ground. Hence my reference to similar as a shaver point.
@persona250
@persona250 28 күн бұрын
@@robintodd3901 yes the battery pack is likely 50v dc but unfortunately it transforms through the inverter to 230v ac so needs the earth rod .
@jamesfrederick3107
@jamesfrederick3107 7 күн бұрын
An Anker promoted by a W⚓️! Nice! 😂
£12,000 rewire Price breakdown
16:26
N Bundy Electrical
Рет қаралды 10 М.
Home Power Outage Backup with the Anker Solix F3800
15:14
Minute Man Prep
Рет қаралды 9 М.
Super gymnastics 😍🫣
00:15
Lexa_Merin
Рет қаралды 106 МЛН
Please be kind🙏
00:34
ISSEI / いっせい
Рет қаралды 158 МЛН
Just try to use a cool gadget 😍
00:33
123 GO! SHORTS
Рет қаралды 85 МЛН
I’m just a kid 🥹🥰 LeoNata family #shorts
00:12
LeoNata Family
Рет қаралды 16 МЛН
Crazy Cable - Did I Mess It Up? Full Install
35:05
N Bundy Electrical
Рет қаралды 38 М.
Easiest Grid-Tied Solar On The Market!   Plug-N-Play
11:12
Everyday Solar
Рет қаралды 30 М.
The Truth about EV Battery Life and Charging Best Practice ! | 4K
23:46
Anker C800X - Finally, a REAL Power Station for $499?
11:49
The Solar Lab
Рет қаралды 33 М.
I Made A Rookie Mistake Installing This Fuseboard
14:01
N Bundy Electrical
Рет қаралды 18 М.
FREE Solar Heating & Air Conditioning Is Finally Here...
21:08
The DIY HVAC Guy
Рет қаралды 541 М.
Planning Gets You Nowhere
21:02
N Bundy Electrical
Рет қаралды 16 М.
“Айбек бейтаныс қызбен көлікке мініп кетті”
25:04
QosLike / ҚосЛайк / Косылайық
Рет қаралды 213 М.