Converting R22 AC Unit to R422B. Plus Leak Search On 2 Units!

  Рет қаралды 14,547

Jeff’s HVAC Adventures

Jeff’s HVAC Adventures

Жыл бұрын

In this video, I leak search a old R22 York package unit. Repair the leak and convert to R422B. Also a leak search and repair on a 410a package unit.
Foam tape:
amzn.to/4bnavVG
Check out these great tools I use on a daily basis! Use the links…SAVE SOME CASH!
WisePro 1000v Insulated Screwdriver set: amzn.to/43nBUV6
Avhrit Electric Pipe Cutter amzn.to/4e6YDKb
Discount code to save 10% : 104H1TFB
TOPTES Combustible Gas Leak Detectors.
4 TO CHOSE FROM!
PT210S
amzn.to/3QSHJEu
Discount Code: GSYQFS4Z
PT299
amzn.to/3R38JlS
Discount Code: 4A3HH88Q
PT199
amzn.to/3M5kTYs
10% off with code: N83SX3Q6
PT520B+ Professional Gas Leak Detector amzn.to/494fISD
10% off with code: R98D8JH8
TOPTES CT-300 CO Detector: amzn.to/499s23E
Discount Code: 953OHRKL
Get yourself a HIK Micro B20 Thermal Imaging Camera. Use this Link!
amzn.to/3KwRw0m
Inficon Gas-Mate Combustible Gas Leak Detector amzn.to/40ifEdL
Tesman TN-213 NCV Tester amzn.to/3rVZY3j
10% off with code: FJDYR4W3
Topdon Thermal Camera for Android amzn.to/46Wldkf
Topdon Thermal Camera for iPhone amzn.to/46Twvpu
WisePro Tradesman Backpack:
amzn.to/4912DYW
If there are any other tools and products I use in my videos that interest you…just ask! I’ll get you a link!
Support the Channel with a Super Thanks or
PayPal: ​⁠@JeffsHVACAdventures
CashApp: $JeffsHVACAdventures
Venmo: @JeffsHVACAdventures
Like and Subscribe!
Questions, comments or to just say Hi, email me
jeffshvacadventures@gmail.com

Пікірлер: 49
@johnsonwayne9279
@johnsonwayne9279 2 ай бұрын
SUPER discussion and execution. You are a master at this work. I wish you were my technician since you just saved me a good amount of money.
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
Appreciate the compliment. 🤙
@B_HVAC
@B_HVAC Жыл бұрын
As always, great work Jeff 🤙.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Thanks man!
@jrh86
@jrh86 Жыл бұрын
Yehhh it is what it is and it's a temporary measure the customer dictates the way forward considering its to get them through and its good business, super video on these two jobs excellent presentation of work. 👍👍👍 always very interesting with a good sense of humour.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Thanks brother!
@johnsonwayne9279
@johnsonwayne9279 2 ай бұрын
I'm just some dufus home owner guy out there. But you are BADASS with your basic technicals and also with your video processing. THANK YOU. My problem, which you are helping with, is my passed fathers home unit. It's a R22 system and at least 30 years old. Major brand, I forget which right now. Over the years I've already repaired - moving the drip conduit from the indoor blocked drain to the exterior; the circuit board (which I got for $40 after waiting awhile) which had the spark igniter failure; the condenser capacitor; the condenser exhaust fan; the handler fan (twice); and other minor maintenance. The unit has been great on heat (after the control board replacement), no CO problems, but the cooling function has gradually declined over 20 years. I recently became aware of the schrader valve thing and this is where I want to compliment you. You are not afraid to share pertinent information. THANK YOU. Your video CONFIRMS the idea of FUCK IT, REPLACE THE SCHRADERS - DO IT - DO IT NOW (The Matrix) I observed your use of valve core removal tools and end hose cutoff valves, all which should be part of any ACmaintenance regimen (THANK YOU). I now have possession of these tools. They are an integral tool for any ac mechanic. They are not "neat" or "cool". They are essential (THANK YOU). I now am "hunting for red october" for a local technician who knows what for on conversion from R22 to R422B. My father left me some R22 but I don't know where it is now. And anything that can reduce my costs to get the old unit running is valuable. Anything you could offer about oil calculations would be nice. THANK YOU Once again - BADASS.
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
I appreciate all the compliments. Thank you very much. If you want to email me jeffshvacadventures@gmail.com for any specific questions, I’ll do my best to answer them for you. 🤙
@DT-jz3wn
@DT-jz3wn 2 ай бұрын
​@@JeffsHVACAdventuresYou're awesome for offering advice. Tough to find ppl like that
@ccthepope
@ccthepope Жыл бұрын
Great video!
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Thanks!
@TedCookHVAC
@TedCookHVAC Жыл бұрын
You're a good tech .... kick that junk off the roof !!
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Lol. Thanks for watching brother!
@supermo26
@supermo26 Жыл бұрын
How do you like that recovery machine? Have you tried the Apion G5 twin?
@eric4467
@eric4467 Жыл бұрын
422b runs low suction with r22 metering device. A larger piston will work or adjust txv open more. If not your saturated suction will stay under freezing.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Good point. I was right around 38° saturation temp when it was fully charged. And it had basically no load in the space. I felt pretty good with it after I finished.
@user-bo2ls5to2j
@user-bo2ls5to2j Жыл бұрын
Jeff, great video. Can you give me an idea what your company charges per lb. for 422B freon ?
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Email me and I’ll let you know. I don’t really like to put pricing out there because what we charge here on the Eastern Shore of MD, might be a lot different what they charge in NY or FL. jeffshvacadventures@gmail.com
@MansoorAlqahtani-ye5xv
@MansoorAlqahtani-ye5xv 17 күн бұрын
Is this an air handling unit with fresh air? In my country i never seen ahu works on R410? It’s either split system or big ahu
@JeffsHVACAdventures
@JeffsHVACAdventures 16 күн бұрын
This unit does have a small amount of fresh air. I believe 10% to meet building occupancy code.
@Balticblue93
@Balticblue93 Жыл бұрын
Just out of curiosity and this is just a question and nothing more. Why use R422B over say MO99(R438B) or one of the others available? I know there are like 10-15 choices. I found R438B or 422B are the two best besides R22 itself. I still have two full R22 jugs for specific systems. But I have also been putting in new compressors and TEV's and using 410A since the coils for R22 are so stout and mostly copper, they work amazing, if you can find 5-ton condensers that are still good, the swap is quite affordable. So far I have done four and they are all pounding away just fine. The newer coils and condensers are so prone to leaking, an old timer asked me why I didn't just swap the compressor, TEV, clean-out the lines and run 410A? I didn't even think about it before that day. I am shocked how well it has worked so far. So I am always curious why some techs use different "drop-ins" It is nice not having to change oils with R422B and R438B, that is why I use those two.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
No specific reason really. I’ve used M099 and didn’t find any issue with it. The 422B is just the most readily available in my area.
@Balticblue93
@Balticblue93 Жыл бұрын
@@JeffsHVACAdventures Thank you for the response! I really enjoy your content and being a tech myself and business owner, getting other’s opinions help me. I have run them both and did not notice much difference either. Denver’s altitude and arid climate makes for an interesting change in pressures and output. We lose about 4% of output capacity for every 1000’ above sea level. I live about 6500’ in the suburbs, so we have to adjust for that. Thanks again and keep up the great content!!
@DT-jz3wn
@DT-jz3wn 2 ай бұрын
I've tried to fill my R22 unit with 422D and thought that it was difficult to get the settings dialed in. There seems to be a huge lack of info for 422D but I'm a diy guy. Does 422B run similar as D? Or are they totally different animals? Thanks so much for any advice
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
I haven’t used 422D. 422B seems to run a little lower suction pressure, but I haven’t had any issues with it.
@boeing757pilot
@boeing757pilot Жыл бұрын
I have a question if you dont mind? My heat pump was changed out to R422B.. I was charged $150 for each pound. That seems very high. I dont mind paying a reasonable markup but that seems excessive. Question: What is considered a reasonable markup. My markup seems to be 500% or more. Is that typical or should I be talking to the company?
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Something to remember, every market is different. What I can buy and sell 422B for might not be what the contractor you used can get it for. Also Different regions have different mark ups. That being said, $150 per lb does seem a little high but if you call the company I’m sure they would be able to explain the mark up to you.
@boeing757pilot
@boeing757pilot Жыл бұрын
@JeffsHVACAdventures Hi Jeff! Thanks for your reply and I understand. I will give them a call. Thanks again!
@erixgar4117
@erixgar4117 10 ай бұрын
for me R22 is 150 per pound. But other that 22 should be toching 100 or less per pound. this is NY@@JeffsHVACAdventures
@ptk7240
@ptk7240 2 ай бұрын
We service close to 2 thousand systems have been topping r22 with r422d for years with no problems pressures close to r22
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
I’ve never had a problem either.
@BLKCFII
@BLKCFII 11 ай бұрын
You must have spent your 8-hour shift on this project. Do you prefer long jobs or several short jobs per shift?
@JeffsHVACAdventures
@JeffsHVACAdventures 11 ай бұрын
I think I had a few different jobs in this same complex that day. It’s been a few months back now.
@Hvac-dude
@Hvac-dude Жыл бұрын
Hey ! What is temp conservation
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Temp compensation? It takes the rise or fall of temperature into consideration when your performing your pressure test and adjusts the delta T of your pressure so it looks like you haven’t dropped any.
@davidherrera2859
@davidherrera2859 Жыл бұрын
407c is the best replacement for r22
@ErickHernandez93
@ErickHernandez93 Жыл бұрын
I would recommend use 407C better buddy, works much better than 422B for air conditioning even pressures are better
@ErickHernandez93
@ErickHernandez93 Жыл бұрын
I live in Maryland as well & have had much better luck with 407C than 422B
@CustomWeldingandFab
@CustomWeldingandFab Жыл бұрын
407c is only compatible with poe oil
@ErickHernandez93
@ErickHernandez93 Жыл бұрын
@@CustomWeldingandFab it still has been able to prove it works better with mineral oil than 422B trust me I have had better lasting compressor with 407c
@phillaird1091
@phillaird1091 Жыл бұрын
Add 20% POE oil into the system on top of the mineral oil. Then use 407c and you’ll rarely ever have make any additional adjustments. But for that POS unit ,any option is a good one.
@kevinstfort
@kevinstfort 27 күн бұрын
@@ErickHernandez93where abouts? I’m looking to fill my R22 with an alternative as I’m being quoted way too much.
@dhood15277
@dhood15277 2 ай бұрын
I was quoted $200 per pound for R422b. So that's why I'm looking at all these videos.
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
That’s a little high for 422B but different locations have higher prices. We charge about half that per lb in Maryland
@kevinstfort
@kevinstfort 27 күн бұрын
Any chance you’d come out to College Park, MD?
@JeffsHVACAdventures
@JeffsHVACAdventures 27 күн бұрын
@@kevinstfort sorry buddy. That’s too far out of my service territory.
@kevinstfort
@kevinstfort 27 күн бұрын
@@JeffsHVACAdventures I understand. Any recommendations for out my way? Would greatly appreciate it.
Charging R-22 into an Air Conditioner that is VERY LOW on Refrigerant!
25:13
AC Service Tech LLC
Рет қаралды 253 М.
No Cooling Service Calls.  Easy Monday Before 4th Of July!
18:11
Jeff’s HVAC Adventures
Рет қаралды 41 М.
Iron Chin ✅ Isaih made this look too easy
00:13
Power Slap
Рет қаралды 36 МЛН
A teacher captured the cutest moment at the nursery #shorts
00:33
Fabiosa Stories
Рет қаралды 54 МЛН
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 4,9 МЛН
Failed Compressors - Don't JUST REPLACE IT
24:59
HVAC School
Рет қаралды 60 М.
R-22 and R-410A Refrigerant Operating Pressures on Air Conditioning Units!
14:56
HVAC 128 Recovery most used but slowest
10:43
Love2HVAC with Ty Branaman
Рет қаралды 76 М.
How to Check AC Freon Level
16:52
Word of Advice TV
Рет қаралды 2,1 МЛН
R22 stand ins are fake imposters !
21:50
Anti DIY HVAC
Рет қаралды 132 М.
Using 407C on An Old R-22 Evaporator Coil Swap
23:22
HVAC GUY
Рет қаралды 22 М.
How To Refill R22 AC With Subcooling Method
14:37
Word of Advice TV
Рет қаралды 366 М.
Where to Find R-22 & R-410A LEAKS on AC Units! Top 10 Spots!
14:46
AC Service Tech LLC
Рет қаралды 196 М.
This Was a TERRIBLE Install….Until Now
16:29
Quality HVACR
Рет қаралды 32 М.
Goodman A/C NOT COOLING!  More Than Just The Obvious!
14:47
Jeff’s HVAC Adventures