EICR - Signs of Thermal Damage C1 or C2?

  Рет қаралды 4,704

GSH Electrical

GSH Electrical

Күн бұрын

In this video Marcus is on site carrying out an electrical installation condition report EICR. During the inspection he comes across thermal damage on the cable feeding the electric cooker.
What code would you give..?
== 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 - Thermal damage
00:51 - Testing the exposed conductive part
01:19 - Melted insulation
01:28 - It's always the neutral
01:47 - HO7 flex
02:02 - Under or over tightened
02:14 - Twisted connection
02:48 - What code C1 or C2
03:32 - Plastic consumer unit
🔵 EICR's Electrical Installation Condition Reports • EICR's Electrical Inst...
🔔 Subscribe for more free electrical training videos kzfaq.info?s...
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram and Twitter lookout for "GSH Electrical.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
#GSHElectrical #Electricaltrainingvideos #electrical #electricaltesting

Пікірлер: 41
@johnhoward2104
@johnhoward2104 3 ай бұрын
Every publication I've read reserves C1 for access to live parts, so is a shock risk, but that is not the issue re that cooker, given the cover didn't appear to be damaged, so can be no higher than a C2, by their standards. Whether you should be coding it at all is a grey area, given it's probably more to do with In-Service Inspection & Testing, rather than an EICR, given it's arguably not part of the fixed wiring - yes, you can code it if desired but whether you should be is debatable.
@GSHElectrical
@GSHElectrical 3 ай бұрын
Thanks for the detailed response 👍🏻
@jasonwatson9011
@jasonwatson9011 3 ай бұрын
Found that nearly exclusively on that manufactures cookers. It's a bad design. When we fitted them you would tighten the cables, wiggle them and they would fall out. Despite the cord grip pulling out the appliance to clean and push it back repeatedly the terminals would pull out. If you over tighten they bend, under tighten they fall out. To be honest you have less issues over tightening them, if under tightend they usually weld themselves in with a high impedance connecting and continue to melt the connector. The appliance is usually repairable with that part readily available. I would C2 but disconnect it and make safe regardless.
@LeighWinspear
@LeighWinspear 3 ай бұрын
Interesting. In petrochemicals, we used to be involved in root cause analysis. Marcus gave his expert opinion and it got me thinking - if this actually caused a fire , how does it get investigated to determine the fault, post fire? Who or what team of people, are actually telling the insurance/owner/equipment manufacturer/media and fire brigade, what exactly went wrong? There must be a learning video in there perhaps. Luckily Ive never experienced a home fire situation but I know folks who have and It cant be a very nice process..............
@electrician247
@electrician247 3 ай бұрын
I knew I left dinner in the oven to long! So good at cooking I can even burn the appliances 😂
@deBoss1969
@deBoss1969 3 ай бұрын
Nice. As someone who only installs gas/electric cooking I see this regularly and it's always on the line conductor. Never seen the neutral burn out. My employer has dropped the coding from our procedure but c2 all day.
@GSHElectrical
@GSHElectrical 3 ай бұрын
Thanks for watching and taking the time to add your experiences in the comments
@LeighWinspear
@LeighWinspear 3 ай бұрын
Why has the coding been dropped?
@David-td1tf
@David-td1tf 3 ай бұрын
Its burnt out because the resistance at that connection is high probably bigger cable will rectify.. had this problem on storage heater which had plug connection, removed plug and direct wired via fused unit sorted the problem.
@tresslerj1985
@tresslerj1985 3 ай бұрын
C2 with written information to the client and end user about a potentially dangerous situation. Leave it turned off.
@GSHElectrical
@GSHElectrical 3 ай бұрын
Thanks for the great comment 👍🏻
@stephencunningham8850
@stephencunningham8850 3 ай бұрын
Is condition reporting not just for fixed wiring
@lewishumphries2893
@lewishumphries2893 Күн бұрын
C2 . Making it clear to the client of the risk and potentially asking for a signature of acceptance
@blobstrom
@blobstrom 3 ай бұрын
I'm assuming the internal wiring behind is also compromised and therefore cannot be repaired easily. I would be asking should a domestic oven be in a commercial environment, admittedly it has lasted a long time, but the manufacturers warranty often will not cover domestic appliances being used in a commercial premises
@GSHElectrical
@GSHElectrical 3 ай бұрын
Thanks for your thoughts 👍🏻
@robertburrows6612
@robertburrows6612 3 ай бұрын
I test up to the outlet to were the cooker is connected. when I PAT test, then I would check the terminal block on the cooker, and also note on the PAT sheet there is thermal damage and the wrong cable is being used and fault needs to be fixed without delay.
@giubaca
@giubaca Ай бұрын
Isn't this fixed equipment?...
@EdwardBretherton
@EdwardBretherton 4 ай бұрын
W hen taking ovens out it is always the neutral , never come across line melting , well apart from the dual fuel range wired in 2.5 twin💥
@deBoss1969
@deBoss1969 3 ай бұрын
I've seen a DF 100 range on 2.5 flex and a plug top...fml!
@GSHElectrical
@GSHElectrical 3 ай бұрын
Likewise 👍🏻
@EdwardBretherton
@EdwardBretherton 3 ай бұрын
1100 mm df range wired in 1.5 twin and earth and piped in 10mm copper, taken out last week,
@Richardincancale
@Richardincancale 3 ай бұрын
A bit of heat shrink will contract around that without even getting out the heat gun!!
@martinnixon2079
@martinnixon2079 3 ай бұрын
It’s a C1 clearly a danger to use. But good find as most electricians wouldn’t remove a free standing cooker just in case you damaged the flooring. We would either disconnect it or charge to replace the connection unit.
@carvanplace
@carvanplace 3 ай бұрын
C2 is what i said in your shorts video. Shame it takes you a long time to reply back. Good video though..👍
@GSHElectrical
@GSHElectrical 3 ай бұрын
Sorry I have tons of messages across all social media channels GSH & eFIXX
@ChrisTheSparky
@ChrisTheSparky 3 ай бұрын
No earth sleeve that's a DIY job all day long
@GSHElectrical
@GSHElectrical 3 ай бұрын
We were hoping someone would spot that Chris 👏🏼
@sergiofernandez3725
@sergiofernandez3725 2 ай бұрын
C1 Themal damage to cable in connector block Possible damage on the terminal Discolouration around the outside of connector block possible thermal Looks like physical damage to cable about 200mm down from connector block Possibly the wrong cable type used (T&E) need to check MI as it may need H07 flex...Caveat Oven MI vs Cooker plate MI Possibly appliance faulty and may be dangerous to use Is that CPC sleaved? Other things to consider Carbon monoxide alarm present in room and In Date IF there is a Gas burning appliance Heat detector in room and In Date Is that rotary switch isolator directly underneath a deep fat fryer????
@Cardetailingburnley
@Cardetailingburnley 3 ай бұрын
I think looking at this c2
@bankraid2183
@bankraid2183 3 ай бұрын
Make a note on the report
@caphaenaddiction
@caphaenaddiction 3 ай бұрын
I ignore the exposed live parts as the only C1 description and C1 something if it’s an immediate or imminent danger to life. Sue me, I’ll stand in front of the 3 chairs and curly wigs and state my case without any fear.
@CellAmen
@CellAmen 3 ай бұрын
C1
@scotisland
@scotisland 3 ай бұрын
C2 but oven not OK to be in service, new terminal block or new oven.
@Davidhughes9467
@Davidhughes9467 3 ай бұрын
C1 all day that insulation on the line has broken which is exposing the live conductor
@GSHElectrical
@GSHElectrical 3 ай бұрын
Thanks for your thoughts 👍🏻
@Oufg103f
@Oufg103f 3 ай бұрын
Shared 👍 c2 then go down the pub😂
@GSHElectrical
@GSHElectrical 3 ай бұрын
🍻
@user-bj5xr5ju4n
@user-bj5xr5ju4n 2 ай бұрын
3:02 the neutral is connected to a phase slot (3) instead of the neutral slot (N).
@themagpie_1
@themagpie_1 3 ай бұрын
all i can see is no cpc and a snipped haircut.. there is also a nic in the outer insulation approx 300mm down the line
@David-td1tf
@David-td1tf 3 ай бұрын
I spotted that aswell
@tonywatson1412
@tonywatson1412 3 ай бұрын
It seems these days we are so lacking in knowledge and common sense, that numbers and letters must be used .... probably because of litigation etc...all the paperwork and quadruple BS...etc....its like everything must be explained to kids....Makes you wonder...
EICR - Issues with an Immersion Heater C1 or C2?
2:17
GSH Electrical
Рет қаралды 2,8 М.
Can Your Installation Rely on a TT Earth Electrode
7:39
GSH Electrical
Рет қаралды 11 М.
СҰЛТАН СҮЛЕЙМАНДАР | bayGUYS
24:46
bayGUYS
Рет қаралды 657 М.
Perfect Bend in Steel Conduit Every Time
6:12
GSH Electrical
Рет қаралды 2,2 М.
How to Diagnose a Deep Fryer Thermostat
2:40
techtown
Рет қаралды 3,7 М.
How to Connect up your First Socket
8:27
GSH Electrical
Рет қаралды 3,7 М.
4 Tools That Will Help You Train to be an Electrician
7:14
GSH Electrical
Рет қаралды 10 М.
Is this Allowed? Wiring Electrical Circuits in Flex…
10:02
GSH Electrical
Рет қаралды 62 М.
Ring Circuit Fault Finding Plus Green Goo
8:18
GSH Electrical
Рет қаралды 18 М.
EICR Tips & Tricks for Beginners + Free Checklist | Electrician TV
15:09
СҰЛТАН СҮЛЕЙМАНДАР | bayGUYS
24:46
bayGUYS
Рет қаралды 657 М.